Loading...
HomeMy WebLinkAboutCorrections and Conditions of PermitGurfteld County Community Development Department 0912512023 Owner: Thunder River Business Center 1655 County Road 109 Glenwood Springs, CO 81601 Architect: Cloud Hill Design, LLC Jeffrey H. Woodruff Snowmass, CO 81654 Contractor: Ridge Runner Construction 1655 County Road 109 Glenwood Springs, CO 81601 Re: Corrections and Conditions of Approval Job Address: 6762 Highway 82 BLCO-05 -23-8105: Building A BLCO-O5 -23-8106: Building B Dear Mr. Woodruff, The plans have been reviewed to the currently adopted codes in Garfield County. lf an item is missed during review, it is the applicant's obligation to comply with all adopted codes in Garfield County. The County Building Department has performed the review on the building permit application and plans for the new buildings proposed at the above address. Please provide a response letter addressing each item listed in the "ltems to address prior to issuing a building permit". Response not required for the "Conditions to be addressed during construction" but please address if clarification is needed. 108 Eighth Street, Suite 401 Glenwood Springs, Colorado 81601 (970) e4s-82t2 Please provide 2 complete sets of corrected sheets, with clouded areas reflecting changes, for the resubmittal. Correctiong to address prior to issuinq a building permit: Note, No response necessary for this comment: 4002 - The tenants are depicted as mercantile uses "M Occupancy". This occupancy group is typically for retail establishments. The review is based on the information provided. /4002 - Please add the Type of Construction and allowable square footages based on the Occupancy Groups proposed. The only notes are found on Sheets 4103 and 4104 stating Type lB, which requires quite a bit of fire-resistive structural members. lf that is the Type of Construction desired, please add details for the structural protection. (lBC Chapter 5) ãrcomplete the grading on the east and west sides of the property will require mobilizingY and grading on adiacent prop_erties. Please provide an agreement with the neighbors.€pyr iro6 i> 'Pa.rur.rc @.'o.uJ t^i=sfagg- Å¡tr; *6¡trøÈs ;l Please provide information from the Colorado Division of Water Resources that the existing- well is approved for the change of use to supply 13,2QQ sq. ft. of commercial space. The orientation of Building t has changed during the design. Please coordinate all sheets to reflect the actual location of both buildings, associated utilities, parking, etc. (lBC 107) I sheets are to be stamped by the design professional ble charge of that aspect of the project. A) The Civil Drawings need to be sta stee need to be sta 1 07) ãn"adopted "Appendix J - Grading" states "Drainageacross the property line shall nott exceed that which exrsfed prior to grading. Excess or concentrated drainage shall be contained on sife or directed to an approved drainage facility."With the installation of the new buildings and parking lot, the drainage as shown is not compliant. Please address accordinsty. (tBC Appendix J) ãNCr. tf}rt+ g6f( øt F¡<¿elftib ¿]* A103/4104 - Please add the vertical grab bar to the ADA Bathroom Requirements. (ANSI 4117.1) S Please show all the parking spots associated for these two buildings. The spaces are to account for the future tenants. For retail or offices 1 space is required for every 250 square feet of floor area. 13,200 sq. ft. total - 576 sq. ft. restrooms = 12,624 leasable space/250 for retail = 51 parking spaces. (LUDC 7-302) ,{Off-street loading is required. Please show loading on the plans where applicable. (LUDC 7- 302) P Show location and details for handicap parking spaces. The space and loading area are to be a hard surface with an accessible route into each building. (lBC 1 106) ¡Þt Please provide a Special lnspection Statement. (lBC 1704.2-3) -,)Z'Please provide details for supporting the gypsum on the ceiling. The purlins appear to be' approximately 40" on center. 108 Eighth Strcct, Suitc 401 Glenwood Springs, Colorado 81601 (e70)e4s-82r2 ftd 13 This permit was submitted prior to July 1't 2023, when the County still had the 2009 lnternational Energy Conservation Code adopted. The R1 roof reference is indicating R-38 with little detail. Silvercote is being referenced as the insulation supplier. The Silvercote details for metal roofs do not match the detail on the plans' https://www.silvercote.com/products-and-svstems/metal-buildinq-insulation/new- coñstruction/ The Code requires an R-3.5 to R-5 thermal blocks based on different versions of insulation details. 2009 IECC Tables 502.2(1) and 502.2(2). Please provide details to indicate code compliance. lf the thermal blocks are eliminated the Prescriptive Method cannot be used. The U-Factor Alternative is the other option allowed in the code. Provide a Comcheck Envelope Report or detail the required thermal blocks. Conditions to be addressed durinq construction: Building Permits are required for each of the Tenant Finishes The approved plans are to be on-site for inspections' Sanitary facilities are required to be provided for workers. A list of required inspections will be attached to the plans. The State is to permit and approve the electrical work. https://www.colorado.qov/pacific/dora/DPO Electrical Plumbino Permits Underground utility locates is the responsibility of the owner or contractor. 811 is the Colorado Utility Locate Hot Line. Drainage across property lines shall not exceed that which existed prior to grading. Excess or concentrated drainage shall be contained on site or directed to an approved drainage facility. Erosion of the ground in the area of discharge shall be prevented by installation of non-erosive down drains or other devices. All backflow preventers are required to be tested and certified by a licensed backflow specialist after installation and prior to issuance of the Certificate of Occupancy. Separate Sign Permits are required for any external signs. Please contact the County Planner for the application. Electrical Code compliance will be determined based on field inspections performed by the State Electrical lnspector, (303) 869-3458. Please have the inspector sign the building card or provide written documentation of the inspections. Please provide special inspections reports to the Building Department as specified within the General Notes of the structural drawings. Geotechnical observation is required when the excavation is complete and written verification be supplied at footing inspection, 2000psf. The recommendations e-mailed from the Geotech Engineer were not based on a specific soils study for this lot. The excavation observation report is required. 108 Eighth Street, Suite 401 Glenwood Springs, Colorado 81601 (970) 94s-8212 Safety glazing is not designated on the plans. Safety glazing will be checked during the framing and final inspection. (lBC 2406.4) Any membrane and through penetrations of the fire resistive construction will be required to be fire-stopped with listed fire stopping assemblies. The contractor is to provide a cut sheet for the assemblies at the framing inspection. (lBC 713) A Knox Box is required to be mounted adjacent to the front door. Please contact the Local Fire District for exact location. The walls surrounding the toilets are to be non-absorbent for a height of 48" and 2' past on each side of the toilet. All accessible door hardware shall have a shape that is easy to grip, including pocket and sliding doors. (ANSI A117.1 - 404.2.6) Abide by all rule for the abandonment of the existing septic system and installation of the new system thru the Environmental Heath permitting process. The water closets in Building 1 will require right hand flush models. Alltenant spaces are provided with garage doors where vehicles can be parked inside. All sources of ignition are to be a minimum 18" above the floor. Combustible materials are limited in Type I and Type ll Construction. See IBC 603 for allowed combustible materials. Sincerely, I"n" fLane John Plano Building Official CC: Ridge Runner Construction 108 Eighth Street, Suite 401 Glenwood Springs, Colorado 81601 (970) 94s-8212