Loading...
HomeMy WebLinkAboutOWTS Permit  Garfield County Public Health  2014 Blake Ave.   Glenwood Springs, CO 81601  Phone: (970) 945‐6614 ext. 8150  For inspections, call: 970‐945‐6614 ext. 8150 and call the Design Engineer, if applicable   Project Address: 34 Kings Row Avenue, Carbondale, CO 81623 Parcel No.: _239121301002  Owner Name: Tamara Tormohlen     Owner Phone: 970‐618‐8335  Designed By: CBO      Designer Phone: (970) 309‐5259  Number of Bedrooms: 2 or 3 Minimum Tank Capacity: 1,000‐gallon or 1,250‐gallon Minimum Absorption: 600 ft2 or 900 ft2     OWTS PERMIT   KEEP AVAILABLE AT PROJECT SITE   Permit Number _SEPT‐8394_______________________________  Permit Type X New X Repair X Remodel/addition X Tank only   Issue Date _11/09/2023____________________ Expiration Date_11/09/2024_________________   Permit Conditions:   This OWTS Permit is approved on the condition of compliance with the report and design as  submitted by CBO, Inc. dated October 21, 2023. Changes to the design and permit must be approved  by Garfield County Public Health and the designer prior to construction.     The new OWTS will serve either an existing 2‐bedroom (or an expanded 3‐bedroom) residence. The  new OWTS components will consist of either the existing 1,000‐gallon septic tank or a new, two‐ compartment 1,000‐gallon septic tank set level with access to grade and an effluent filter installed in  the outlet tee of the tank. Effluent will gravity flow to a distribution box set level with access to  grade that will distribute effluent to 612 ft2 or 912 ft2 of STA. The new STA will consist of three (or  four) gravelless chamber trenches consisting of 17 (or 19) Infiltrator Quick4 chambers (51 or 76  chambers total). Inspection ports will be installed at each end of each trench.  Maintain all setbacks  and elevations as designed.    Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final  inspection of the installed system prior to backfill. NO OWTS COMPONENT SHALL BE BACKFILED  WITHOUT PRIOR APPROVAL FROM GARFIELD COUNTY PUBLIC HEALTH AND THE DESIGNER.  Agreement   All installations must comply with all requirements of the Garfield County OWTS regulations  including but not limited to the conditions specified above.   In consideration of the issuance of the permit, the applicant hereby agrees to comply with all  laws and regulations related to the zoning, location, construction, and erection of the proposed  OWTS and associated structures for which this permit is granted. The applicant further agrees  that if the above said regulations are not fully complied with in the zoning, location, erection,  and construction of the above described OWTS and structure, the permit may then be revoked  by notice from the Health Department and immediately become null and void.  The issuance of a permit and specifications of terms and conditions therein will not constitute  assumption of liability, nor create presumption that the local public health agency or its  employees may be liable for the failure or malfunctioning of any system. Permit issuance will  not constitute a certification that the system, the equipment used in the system, or any  component used for system operation will ensure continuous compliance with the provision of  the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.   Permit Approval  Plans and specifications for the proposed OWTS have been reviewed and are considered  satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated  in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from  the date of issuance unless construction on the system has commenced. An "as‐built" drawing  must be submitted and inspection of the system must be completed by GCPH before final  approval of the system will be issued.        11/09/2023  Issued By: Garfield County Environmental Health  Department  Date