Loading...
HomeMy WebLinkAboutOWTS Permit Revised 11.09.2023  Garfield County Public Health  2014 Blake Ave.   Glenwood Springs, CO 81601  Phone: (970) 945‐6614 ext. 8150  For inspections, call: 970‐945‐6614 ext. 8150 and call the Design Engineer, if applicable   Project Address: 364 Storm King Road New Castle, CO 81647 Parcel No.: _218306100057  Owner Name: Nutrient Holdings LLC     Owner Phone: (970) 366‐2478  Designed By: SGM      Designer Phone: (970) 945‐1004  Number of Bedrooms: _0_ Minimum Tank Capacity: 1,500‐gallon Minimum Absorption: 1,831 ft2  OWTS PERMIT   KEEP AVAILABLE AT PROJECT SITE   Permit Number _SEPT‐7966_& SEPT‐8152 Revised  Permit Type X New X Repair X Remodel/addition X Tank only   Issue Date _11/09/2023____________________ Expiration Date_11/09/2024_________________   Permit Conditions:   This OWTS Permit is approved on the condition of compliance with the report and design as  submitted by SGM dated October 3, 2023. Changes to the design and permit must be approved by  Garfield County Public Health and the designer prior to construction. Condition of Permit: The  designer shall review the subsoil in the STA excavation for potential signs of compaction and  provide a report to GCPH indicating if compaction was observed or not.    The new OWTS will serve three mobile offices, a food truck restaurant, a farm store, and a  greenhouse. The system will consist of a new, two‐compartment 1,500‐gallon septic tank set level  with access to grade and a high‐head pump in the second chamber. A grease interceptor tank will be  installed between the food truck restaurant and the septic tank. Effluent will be pumped to an  automatic distributing valve set at the high point of the system that will distribute effluent to 1,872  ft2 of STA. The new STA will consist of six gravelless chamber trenches, each trench consisting of 26  chambers per trench (126 chambers total) on top of a 2‐foot‐deep unlined sand filter. Distribution  laterals are to be 1 ½ inch Schedule 40 PVC with 5/32‐inch orifices 4‐feet on center and the laterals  ending in flushing valves at the distal end of the laterals. Laterals are to be hung from the underside  of the chambers with zip‐ties. The orifices are to be facing upward, except for the first and last  orifice (which shall face downward for drainage purposes). Inspection ports are to be installed at  each end of each trench.  Maintain all setbacks and elevations as designed.    Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final  inspection of the installed system prior to backfill. NO OWTS COMPONENT SHALL BE BACKFILLED  WITHOUT PRIOR APPROVAL FROM GARFIELD COUNTY PUBLIC HEALTH AND THE DESIGNER.  Agreement   All installations must comply with all requirements of the Garfield County OWTS regulations  including but not limited to the conditions specified above.   In consideration of the issuance of the permit, the applicant hereby agrees to comply with all  laws and regulations related to the zoning, location, construction, and erection of the proposed  OWTS and associated structures for which this permit is granted. The applicant further agrees  that if the above said regulations are not fully complied with in the zoning, location, erection,  and construction of the above described OWTS and structure, the permit may then be revoked  by notice from the Health Department and immediately become null and void.  The issuance of a permit and specifications of terms and conditions therein will not constitute  assumption of liability, nor create presumption that the local public health agency or its  employees may be liable for the failure or malfunctioning of any system. Permit issuance will  not constitute a certification that the system, the equipment used in the system, or any  component used for system operation will ensure continuous compliance with the provision of  the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.   Permit Approval  Plans and specifications for the proposed OWTS have been reviewed and are considered  satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated  in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from  the date of issuance unless construction on the system has commenced. An "as‐built" drawing  must be submitted and inspection of the system must be completed by GCPH before final  approval of the system will be issued.        11/09/2023  Issued By: Garfield County Environmental Health  Department  Date