Loading...
HomeMy WebLinkAboutPlans BLGD DSheep, Index REVISION Ogte /ER�AN0 REASED SHEETVBI I9/22/76 Tcrms BEW Blank Endwall BSW Blank Sidewall BLDG. Building CNR Corner COL Column CTR. Center DIA. Diameter DBL. Double EPDM Ethylene—Propylens— DTene—Monomer EW Endwall EXT Exterior F.O. Finished Openinc F.M. Field Modify GA. Gauge GALV. Galvanized ALVM. Galvalume I.D. Inside Diameter INT Interior MISC. Miscellaneous MPH Miles Per Hour NOM. Nominal TRACHTE BUILDING SYSTEMS, INC. MINI -STORAGE BUILDING Terms NTS. Not To Scale O.C. On Center OPP. Opposite PART Partition PT Partition PSF Pounds Per Sq. Foot PTD. Painted QTY. Quantity REQ'D. Required R.O. Rough Opening S.D. Self Drilling STR. Starter TYP. Typical WWF Welded Wire Fabric lb —DIGIT NUMBER 50005000 _PART 00 COMPONEN COLOR 1 /4: 12 PITCH LEAN-TO Colors ASGY Ash Gray BWHT Bright White CDRD Cedar Red CLBG Classic Beige CRMB Cream Beige CONB Contl. Brown DTAN Desert Tan EVGN Evergreen GARN Garnet IWHT Iced White ORAN Sunset Orange PLBL Polar Blue ROYB Royal Blue SGRY Slate Gray dart Numbering T NUMBER 2—DIGIT CODE GAGE IDENTIFIES MATERIAL COLOR OR GAGE STRUCTURAL PARTS USE GAGE CODE NON—STRUCTURAL PARTS USE COLOR CODE 4—DIGIT RANDOM NUMBER RANGE FROM 0000 TO 9999 MOST COMPONENTS WILL FOLLOW A LOGICAL SEQUENCE BASED ON HOW OR WHERE THEY ARE USED ON A BUILDING 4—DIGIT COMPONENT CODE THIS IDENTIFIES A CLASS OF PARTS SUCH AS COLUMNS, HEADERS, BASEPLATES ETC. 9—DIGIT NUMBER 33COMPONENT e � FINISH LENGTH Imaginary Decimal Point 5-DIGIT LENGTH FIRST 3-DIGITS = INCHES LAST 2-DIGITS ARE DECIMAL (FRACTION) ALWAYS IMAGINE A DECIMAL POINT BEFORE LAST 2-DIGITS 2-DIGIT CODE IDENTIFIES MATERIAL COLOR OR GAGE STRUCTURAL PARTS USE GAGE CODE NON-STRUCTURAL PARTS USE COLOR CODE 2-DIGIT PROFILE CODE THIS IDENTIFIES A STANDARD PROFILE SUCH AS PANELS, TRIMS, STUDS, ETC. 2—DIGIT 24101r 2—DIGIT 2—DIGIT 2—DIGIT 2—DIGIT GAGE CODES WALL k TRIM DOOR or TRIM DOOR or TRIM S.S. Roof Special pecial 12 = 12—Gaga COLOR CODES COLOR CODES COLOR CODES COLOR CODES COLOR CODES 14 = 14—Gage 60 = Cream Beige 21 = Ash Gray 44 = Conti. Brown 10 = Regal White 11 = Roman Blue 28 = Clay 37 = Sand Stone 16 = 16—Gage a 61 = Slate Gray 26 = Matte Black 45 = Garnet 9 Y 12 = Evergreen 38 = VP Charcoal Black 18 = 18—Gage 62 =Classic Beige 31 =Patriot Red (Door) 46 =Evergreen 13 = Patrician Bronze 39 = VP Patrician Bronze Pat 63 = Iced White 40 = Sunset Orange 47 = Cedar Red 14 = Surrey Beige 49 = Natural Stone 2—DIGIT 27 = Light Stone 41 = Desert Tan 48 = Shale 23 = Regal/Harbor Blue 65 = Uncle Bob's Yellow COLOR CODES 42 = Polar Blue 63 = Iced White 43 = Royal Blue 64 = Bright White (Door) 24 = colonial Red 66 = Silver Metallic 80 = Galvanized 32 = lime Green (Door) 26 =Malls Black 67 =Birch White 82 =Galvalume 82 = Galvalume 6—DIGIT PART NUMBERS ARE ALSO USED. THESE FOLLOW NO SPECIFIC STRUCTURE. THEY ARE COMMONLY USED FOR FASTENERS, SWING DOORS, PEAK BOXES, AND SOME OTHER PARTS. Most of Trachte's standard color codes are shown. Special colors are not shown. Permit plans may not show the correct color of your desired building. The final erection set of drawings may show the correct colors ordered. The colons may not always be shown within the drawing set but the material listing will always show the correct color for the part listed. Glossary Anchor Bolts -- Bolts used to anchor eave/base angles or channels, and base plates to a foundation or other support. Angle, Eave/Base -- An angle or channel used at the base or top of a paneled wall section. Channels are Channel, Eave/Base usually used when the wall section is insulated. Base Plate -- A plate attached to the bottom of a column or jamb which rests on a foundation or other support, usually secured by anchor bolts. Bracing -- Angles or straps used in the plane of the roof and walls to transfer loads, such as wind, seismic and crane thrusts to the foundation. Bridging -- Series of bracing used in the roof framing to stiffen purlins. Clip -- A plate or angle used to fasten two or more members together. Column -- A main member used in a vertical position on a building to transfer loads from main roof rafters, or purlins to the foundation. Eave -- The line along the sidewall formed by the intersection of the planes of the roof and wall. Footing -- A pad or mat, usually of concrete, located under a column, wall or other structural member, that is used to distribute the loads from that member into the supporting soil. Girt -- A horizontal structural member that is attached to sidewall or endwall columns and supports paneling. Gutter -- A light gauge metal member at an eave, valley or parapet designed to carry water from the roof to downspouts or drains. Header -- The horizontal framing member located at the top of a framed opening, (doors). Jamb -- The vertical framing members located at the sides of an opening (doors). Purlin -- A horizontal structural member which supports roof covering. Rafter -- The main beam supporting the roof system. Rake Angle -- Angle fastened to purlins at rake for attachment of endwall or partition panels. Structural Line -- Usually chalk lines laid out on the foundation to aid in placing columns and other structural components of a building floor plan. Accurate placement of these lines is critical to erecting a building. Rake Trim -- A trim designed to close the opening between the roof and endwall panels. Ridge -- The horizontal line formed by opposing sloping sides of a roof running parallel with the building length. Symbols Materials ORevision Indicator <\01 Notation Reference Detail Detail Identification/Reference Page Detail Detail Identification Detail Section Identification/Reference Page Part No. Part Number Identification 12 Rise/Run Identification 4 F _ North Arrow o: O z Concrete �������II Earth I Insulation D•S Down Spout OO PAG" DESCRIPTION Al FLOOR PLAN & ELEVATIONS — BLDG D B1 FOUNDATION PLAN C1 INTERIOR WALL FRAMING DETAILS C2 END WALL ELEVATION DETAILS C3 END WALL ELEVATIONS C4 ROOF FRAMING PLAN E1 SIDEWALL ELEVATION DETAILS E2 SIDEWALL ELEVATIONS E3 SIDEWALL ELEVATIONS E4 STEP PAGE F1 INTERIOR PARTITION WALL DETAILS F2 INTERIOR PARTITION WALL DETAILS F3 EXTERIOR PANEL PAGE F4 EXTERIOR PANEL PAGE G1 STANDING SEAM ROOF J1 GUTTER PAGE Code CODE CONSTRUCTION TYPE USE GROUP GROUND_ SNOW LOAD_ MIN. ROOF SNOWLOAD Summary ' C2015 INTERNATIONAL BUILDING CODE P II B MODERATE HAZARD STORAGE, S-1 40 psf 40 Psi SNOW IMPORTANCE FACTOR 0.8 WIND VELOCITY (V ULT) 105mph WIND VELOCITY (V ASD) 81 mph WIND EXPOSURE CATEGORY C SEISMIC USE GROUP I SPECTRAL RESPONSE ACCELERATION (SS) 0.333 SPECTRAL RESPONSE ACCELERATION (Si) 0.083 SPECTRAL RESPONSE ACCELERATION (SDS) 0.340 SPECTRAL RESPONSE ACCELERATION (SD7) 0.133 SITE CLASS D SEISMIC DESIGN CATEGORY C Structural Fasteners Trachte structural bolts are SAE J429—Grade-2 or ASTM A307A unless specifically noted. These are typically Trachte Part No's 760110 & 764200. All bolt holes shall be aligned to permit insertion of bolts without undue damage to threads. Bolts shall be placed in all holes and nuts threaded to complete assembly. Compacting joint to snug —fit condition shall progress systematically from most rigid part of joint. Snug —tightened condition is tightness attained with a few impacts of impact wrench or full effort of ironworker using ordinary spud wrench to bring connected plies into firm contact. Specification for Structural Joints Using High Strength Bolts, December 31, 2009 Self Drilling Fasteners Use self —drilling screws in the locations, quantities, and methods shown or noted on these drawings. Self —Drilling Fasteners should be used in accordance with SAE J78 specifications for Self —Drilling Screws. WARNING: When installing Self —Drilling screws, take care to minimize exposed screwpoint hazard, by locating screws next to panel bends and near recessed corners of angles. Structural Bracing All structural bracing is an integral part of the structural system and should be installed where noted or shown on the Floor Plans & Roof Framing Plans all connections should be consistent with all details related to installation of bracing components. Removal or alteration of bracing without prior authorization is prohibited. Temporary Bracing Temporary supports or bracing required to erect the building is the responsibility of the erector to determine, furnish, install and remove. Permits It is the responsibility of the Building Owner/ Contractor/ Erector to obtain all appropriate approvals and necessary permits from City, County, State, or other agencies as required. Structural Lines Structural lines are referenced often throughout our drawing details. These relate to the chalk lines that are to be laid out on the foundation. The lines should always be laid out taking into consideration the inherent imperfections commonly associated with foundations. The edge of a foundation is seldom straight enough to use as a base for dimensioning. It Is recommended to begin your layout at 10'-1" from the sidewall edge (refer to "Locating The First Line" in the Trachte Erection Manual). All other lines should be placed accurately from the first line. By Others The design, detailing, and materials for items designated as "By Others" are not the responsibility of Trachte Building Systems, Inc. NOTICE THE SPECIFIC PROJECT INFORMATION PROVIDED TO TRACHTE BUILDING SYSTEMS, INC. WAS USED IN THE DEVELOPMENT OF THE ENGINEERING DRAWINGS, DETAILS, MATERIALS LIST AND PRICING. ANY DISCREPANCIES BETWEEN THIS INFORMATION AND THE ACTUAL JOB CONDITIONS WILL AFFECT THE ACCURACY OF THIS WORE. TRACHTE IS NOT RESPONSIBLE FOR ANY ADDITIONAL MATERIALS OR ANY LAYOUT PROBLEMS CAUSED BY INACCURATE SITE INFORMATION. PLEASE RECHECK THIS INFORMATION CAREFULLY.' ti h p� o� o h^ W o 3 3�= 0 1>21 z .ate C 3 k al <O 3 E- 3 E- to O W �D U >, a E-+ ¢' a 0 Od o � Fo,,,, 8/23/16 by SEW N.T.S. Plan No. Order No. Cover C LEAN-TO 1 F3 2 HIGH SIDE ------�-- STARTER BAY----r—I ----- TYPICAL BAY ---- -- ------ tructural I �ne I structural tructural yj tructural Line ine Line + 504501218 1 504501216 i r r i r i E4 5950011518 ` _ 5950011518 3 4 ORIENTATION IN STARTER BAY HIGH SIDE OF STEP HIGH SIDE OF STEP is 6. S A E2 504501216 r � 5950011518 C� T A F4 14 15 16 17 DLHS DLHS DKHS 5992001318 5992001118 IN 19 2 5991000718 B A F4 C3 DH 5991000318 E E1 504-501216 504501216 "10--o. 504501216 10.-0. 10'-0" 10'-0" 10'-0. 10'-0" 10'-0" 101-0• 10'-0" 10'-0" 10'-0. 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10--0" 10'-0" 101-0" 10'-0" STARTER BAY DS J1 DS DS 6 DSDDSDS DS DS DS 200'-0" E4 F3 $—A" it = 1 I—n„ DOOR SCHEDULE QTY CODE TYPE SIZE ROUGH OPENING (REF.) MANUF. DESCRIPTION COLOR 8 DE ROLL —UP 8'-8" x 7'-0" 8'-8" x 7'—O" TRAC—RITE e . ROLL —UP DOOR COLORED 2 DEDD ROLL —UP 8'-8" x 7'-0" 8'-8" x 7'-0" TRAC—RITE e . NON —OPERATIONAL DOOR COLORED 10 DF ROLL —UP 9'-0" x 7'-0" 9'-0" x 7'-0" TRAC—RITE/eq. ROLL —UP DOOR COLORED 2 DG ROLL —UP 8'-8" x 6'-6" 8'-8" x 6'-6" TRAC—RITE e . ROLL —UP DOOR COLORED 2 DH ROLL —UP 9'-0" x 6'-6" 9'-0" x 6'-6" TRAC—RITE e . ROLL —UP DOOR COLORED 1 DKDH ROLL —UP 8'-8" x 7'-10" 8'-8" x 7'-10" TRAC—RITE e . NON —OPERATIONAL DOOR COLORED 7 DKHS ROLL —UP 8'-8" x 7'-10" 8'-8" x 7'-10" TRAC—RITE e . ROLL —UP DOOR COLORED 8 DLHS ROLL —UP 9 —0 x 7 —10 9 —0 x 7 —10 TRAC—RITE e . ROLL —UP DOOR COLORED 2 DMHS ROLL —UP 8'-8" x 7'-7" 8'-8" x 7'-7.5" TRAC—RITE e . ROLL —UP DOOR COLORED 2 DNHS ROLL —UP 9'-0" x 7'-7" 9'-0" x 7'-7.5" TRAC—RITE eq. ROLL —UP DOOR COLORED 1 DX ROLL —UP 9'-0" x 6'-11" 9'-0" x 6'-11" TRAC—RITE/eq. ROLL —UP DOOR COLORED 2 DY ROLL —UP 8'-8" x W-11" 8'-8" x 6'-11" TRAC—RITE/e . ROLL —UP DOOR COLORED ROLL —UP DOORS MEET ASTM E330 »_ 11-n" roc v�.�ivry Oate C T z N i J Q U t Q 3 to •�,��iaJ� E U1 t w W CL j O_ V' Q N N j UU Z _o��� J a a) d 0] Qh c � E 3 x QD j o 3 U a m E o s\ U 4 Of h O O 0o y, w a w x A O a O � U o o � m y Dote 8/23/16 Drown by SEW Scale 1/8" = 1'-0" Plan No. 47868 Order No. Sheet No Al i Ln — 0 I in 0 I in �L / N U g I 10 20 I in O I in a 0 I in I in GENERAL FOUNDATION NOTES FOUNDATION SPECIFICATIONS 1. FLOOR SLAB SHALL BE (SEE LEGEND) THICK WITH 6 X 6 — W1.4 X W1.4 WELDED WIRE FABRIC. 2. CONCRETE SHALL BE OF A MIXTURE AND DENSITY TO YIELD A 2,500 PSI COMPRESSIVE STRENGTH AT 28 DAYS. NOTE: STRUCTURAL DESIGN IS BASED ON 2,500 PSI. HOWEVER, 3,000 PSI IS PREFERRED. 3. REINFORCING STEEL SHALL CONFORM TO ASTM A-615, GRADE 60 FOR /4 AND LARGER BARS, AND GRADE 40 FOR j3 BARS AND ALL DOWELS AND TIES. STEEL SHALL BE KEPT CLEAN AND FREE OF RUST. LAP ALL REINFORCING A MINIMUM OF 28" AT SPLICES AND AROUND CORNERS. 4. WELDED WIRE FABRIC SHALL CONFORM WITH ASTM A-185, AND SHALL BE LAPPED 8 INCHES MINIMUM AT ALL SIDE AND END LAPS. NOTE: WELDED WIRE FABRIC IS USED IN THE STRUCTURAL DESIGN OF THE FLOOR SLAB. THEREFORE, FIBER REINFORCING CANNOT BE USED AS AN ALTERNATE. 5. VAPOR BARRIER SHALL BE A MINIMUM OF 6 MIL POLYETHYLENE WITH JOINTS LAPPED NOT LESS THAN 6 INCHES. 6. STRUCTURAL ANCHORS SHALL BE POWERS WEDGE BOLT + SCREW ANCHORS TO BE PROVIDED BY TRACHTE BUILDING SYSTEMS. INSTALLATION INSTRUCTIONS ARE SPECIFIED IN NOTE 01 ON THE ERECTION DETAIL PAGES. 7. NON-STRUCTURAL ANCHORS SHALL BE EITHER POWDER ACTUATED ANCHORS OR TAPCON SCREW ANCHORS. THESE ANCHORS ARE NOT SUPPLIED BY TRACHTE BUILDING SYSTEMS. INSTRUCTIONS FOR LOCATING NON-STRUCTURAL ANCHORS ARE SPECIFIED IN NOTE 02 ON THE ERECTION DETAIL PAGES. NON-STRUCTURAL ANCHORS SHALL BE INSTALLED PER MANUFACTURERS SPECIFICATIONS. 8. FREE DRAINING GRANULAR FILL SHALL BE A NON FROST SUSCEPTIBLE FILL MATERIAL CONSISTING OF COURSE SAND, CRUSHED ROCK, OR AN APPROVED EQUIVALENT. FOUNDATION DESIGN NOTES: 1. FOUNDATION PLAN SHOWN IS DESIGNED FOR A PRESUMED 1,500 PSF ALLOWABLE BEARING PRESSURE. 2. PLEASE NOTIFY ENGINEER OF ANY UNUSUAL CONDITIONS. GENERAL FOUNDATION NOTES: 1. NOTCH SHALL BE LEVEL WITH NO PITCH. 2. FOUNDATION MUST BE SQUARE AND LEVEL 3. PROVIDE CONTROL JOINTS AT 15'-0" ON CENTER MAXIMUM SPACING. ALL CONTROL JOINTS SHOULD BE LOCATED AT LEAST 1 FOOT OFF OF THE TRACHTE BUILDING SYSTEMS COLUMN GRID SHOWN ON THE FOUNDATION PLAN. TRACHTE BUILDING SYSTEMS, INC. IS ONLY RESPONSIBLE FOR THE DESIGN OF THE FOUNDATION TO ACCEPT OUR BUILDINGS. THE DESIGN IS BASED ON THE PARAMETERS SPECIFIED IN THE NOTES, AND THE LOADS IMPOSED BY OUR BUILDING SYSTEM. IT IS THE OWNERS RESPONSIBILITY TO NOTIFY TRACHTE'S ENGINEERING DEPARTMENT OF ANY UNUSUAL SITE CONDITIONS OR OF ANY MATERIALS NOT SUPPLIED BY TRACHTE, THAT WILL IMPOSE LOADS ON THE FOUNDATION SYSTEM. ACTUAL CONSTRUCTION OF THE FOUNDATION, INCLUDING LABOR AND MATERIALS FOR PLACING OF REINFORCING STEEL AND CONCRETE IS BY OTHERS AND THEREFORE, NOT THE RESPONSIBILITY OF TRACHTE BUILDING SYSTEMS. 160'-2" 40'-0" L rr 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 B1 1 1B I I i I B1 B 1 A — — — — — — — — — — — — — — — 18 B1 19 20 1 B1 3 I 3 1 3 I �� B1 61L4 81 3 B1 SRP HEIGHT STEP HDGHT SRP HEWT STEP HEIGHT B1 1 17 Bl Bi I I I B 1D'-1" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-1" 200'-2" FOUNDATION PLAN for MINI STORAGE BUILDING D ' FOUNDATION' LEGEND ®PAVING OR FINISHED GRADE FREE DRAINING ,•�•` INORGANIC GRANULAR FILL EARTH SLAB THICKNESS 4" WEDGE BOLT (INTERIOR) 3/8" x 2 1 /2' WEDGE BOLT (EXTERIOR) L3/8" x 2 1 /2' WEDGEBOLT /4 REINFORCING BAR 1" CONTINUOUS WELDED WIRE 9" FABRIC VAPOR BARRIER 4" LAB THICKNESS — (SEE LEGEND) 4" FILL 3" CLEAR - 611=11 11 11= I I I —I I I'`•._k�.�,.:`�`..::'::`:.�a`�� ,. I � 1=1 � 1=1 � 1=1 � 1=1 � I 6" O FLOATING SLAB DETAIL, NOTCHED T FOUNDATION EDGE I DIMENSION VARIES 21"MIN. OPEN -HOLE SOILS REPORT IS REQUIRED AT FOOTING INSPECTION 1� 500 PSF WEDGEBOLT 10" �- 3" CLEAR WELDED WIRE VAPOR BARRIER FABRIC i SLAB THICKNESS (SEE LEGEND) 4" FILL DSLAB, INTERIOR SECTION DIMENSION VARIES 2j'MIN. A WEDGE BOLT LOCATION, CORNER DIMENSION VARIES 5"MIN. r WEDGEBOLT I FOUNDATION EDGE I #4 REINFORCING BAR CONTINUOUS WELDED WARE 9" FABRIC VAPOR BARRIER j LAB THICKNESS LEGEND) Z. ` 4" FILL 7777:r — —I I —III —III 1'-10" III —III —I 1=1 1I— II,;1111_IIIII;IIII1111111, �1 6" � g FLOATING SLAB DETAIL, NOTCHED DIMENSION VARIES 2j"MIN. I. O WEDGE BOLT LOCATION, EXTERIOR #4 REINFORCING BAR CONTINUOUS WELDED WIRE VAPOR BARRIER FABRIC 5" L� CLEAR SLAB THICKNESS (SEE LEGEND) STEP HEIGHT 4" FILL \\ (SEE FOUNDATION PLAN) ICI III ". PAD (S �IC�OKNEss 3"CLEAR = _ ,.:..:: ` 44" FI • F A.a . t1 i Pi III —III—III — I • . \.! :. '•..:. ...i .k'•'�` •I•I III • —11 THE UPPORTING WALL MUST REST 111, I I -1 I I I, - 1=1 ON THE HIGH SIDE OF THE STEP. 8" 8" 3 FLOATING SLAB DETAIL, STEP id 2,j" ine REF. INTERIOR COLUMN rid BASEPLATE ine WEDGEBOLT 2" REF. SEE FLOOR PLAN TO LOCATE & ORIENTATE BASEPLATE & INTERIOR COLUMNS C WEDGE BOLT LOCATION, INTERIOR BASEPLATE WEDGEBOLT FOUNDATION EDGE -i 11=1 11-1 I II WEDGE BOLT ANCHOR TO BE ERECTOR INSTALLED IN LIEU OF CAST —IN —PLACE ANCHOR BOLTS. MINIMUM EMBEDMENT DEPTH = (WEDGE BOLT LENGTH) + I". WEDGE BOLT, SECTION, FOUNDATION EDGE r�r V(J!V/V Date CO s J ro B O i l I Z r d°I ss0..��� V ti C y a1 O q) c 3 � M LLI W } o o a E D ^ 3 N c O O eh m 3 k m j 0 3 V Q) \ o c 4 F A CID �o z a 0 w o x zA z 0 o U m Date 8/23/16 Drawn by SEW Sco/e 1/8" = 1'-0" Plan No. 47868 Order No. — Sheet No. B1