Loading...
HomeMy WebLinkAboutOWTS Permit  Garfield County Public Health  2014 Blake Ave.   Glenwood Springs, CO 81601  Phone: (970) 945‐6614 ext. 8150  For inspections, call: 970‐945‐6614 ext. 8150 and call the Design Engineer, if applicable   Project Address: TBD Rodeo Drive, Rifle, CO _      Parcel No.: _217734300375  Owner Name: Mario D Rena      Owner Phone: (970) 355‐0357  Designed By: American GeoServices, LLC   Designer Phone: (888) 276‐4027  Number of Bedrooms: _3_ Minimum Tank Capacity: 1,000‐gallon Minimum Absorption: 563 ft2    OWTS PERMIT   KEEP AVAILABLE AT PROJECT SITE   Permit Number _SEPT‐8459_______________________________  Permit Type X New X Repair X Remodel/addition X Tank only   Issue Date _01/31/2024____________________ Expiration Date_01/31/2025_________________   Permit Conditions:   This OWTS Permit is approved on the condition of compliance with the report and design as  submitted by American GeoServices, LLC. dated October 30, 2023. Changes to the design and permit  must be approved by Garfield County Public Health and the designer prior to construction.     The new OWTS will serve a new three‐bedroom residence. The system will consist of a new, three‐ compartment 1,000‐gallon septic tank with a high‐head effluent pump in the third compartment of  the tank. Effluent will be pumped to a manifold that will distribute effluent to 720 ft2 of STA. The  new STA will consist of two unlined sand filter beds, each bed consisting of two rows of 15 Quick4  chambers placed on 3‐feet of secondary sand material. Distribution laterals are to be 1 ½ inch  Schedule 40 PVC, with 3/16‐inch orifices 3‐feet on center and the laterals ending in flushing valves at  the distal end of the laterals. Laterals are to be hung from the underside of the chambers with  orifices facing upward. Inspection ports shall be installed at each end of each lateral.  Maintain all  setbacks and elevations as designed.    Contact Garfield County Public Health at least 48 hours prior to requesting final inspection of the  installed system prior to backfill. NO OWTS COMPONENT SHALL BE BACKFILLED WITHOUT PRIOR  APPROVAL FROM GARFIELD COUNTY PUBLIC HEALTH AND THE DESIGNER.    Agreement   All installations must comply with all requirements of the Garfield County OWTS regulations  including but not limited to the conditions specified above.   In consideration of the issuance of the permit, the applicant hereby agrees to comply with all  laws and regulations related to the zoning, location, construction, and erection of the proposed  OWTS and associated structures for which this permit is granted. The applicant further agrees  that if the above said regulations are not fully complied with in the zoning, location, erection,  and construction of the above described OWTS and structure, the permit may then be revoked  by notice from the Health Department and immediately become null and void.  The issuance of a permit and specifications of terms and conditions therein will not constitute  assumption of liability, nor create presumption that the local public health agency or its  employees may be liable for the failure or malfunctioning of any system. Permit issuance will  not constitute a certification that the system, the equipment used in the system, or any  component used for system operation will ensure continuous compliance with the provision of  the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.   Permit Approval  Plans and specifications for the proposed OWTS have been reviewed and are considered  satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated  in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from  the date of issuance unless construction on the system has commenced. An "as‐built" drawing  must be submitted and inspection of the system must be completed by GCPH before final  approval of the system will be issued.        01/31/2024  Issued By: Garfield County Environmental Health  Department  Date