Loading...
HomeMy WebLinkAboutPlansCONDITIONS OF PERMIT B LCO-9-13-2982 Nieslanik/Spring Valley Compressor Station Compressor Building Sec.3, T7S, R88W Carbondale, Colorado F7ft220:�7�M 1) ALL WORK MUST COMPLY WITH THE 2009 IBC AND MANUFACTURERS SPECIFICATIONS 2) ALL WORK MUST COMPLY WITH THE CONDITIONS OF THE CURRENT LAND USE PERMIT. 7210 3) ALL WORK SHALL COMPLY WITH STATE AND FEDERAL REGULATIONS. 4) EXCAVATION OBSERVATION REPORT REQUIRED AT FOOTING INSPECTION, 4000 PSF. 5) ALL HIGH STRENGTH BOLTING AND FIELD WELDING REQUIRES SPECIAL INSPECTOR. 7200 ----- PROVIDE APPROVAL REPORT AT FRAME INSPECTION. 6) FIRE DISTRICT FINAL APPROVAL REPORT IS REQUIRED FOR CO/FINAL INSPECTION. r ^_ 7) ELECTRICAL ROUGH IN APPROVAL IS REQUIRED AT FRAME INSPECTION. 7190�_ 8) ELECTRICAL FINAL APPROVAL IS REQUIRED FOR FINAL INSPECTION. --- --- 9) LIGHT AND VENTILATION PER 2009 IBC, CHAPTER 12. ---- ---'-- 10) LOCKS, LATCHES AND LANDINGS PER 2009 IBC, SECTION 1008. — 7180 11) GARFIELD COUNTY FINAL INSPECTION REQUIRED FOR COMPLETION APPROVAL. 7178 S 7178--^- -"'--- - 1 �•-.ROAD^�-��- "L 1 71i/y`e 40'-3" 11`-9' 40'-3" 33'-9" 120'-3" j (NOTE 3) / (NOTE 3) ! S-101 SD SILENCER S-100 STARTING GAS SILEN ER ST-GTUO ENGINE EXHAUST TACK INSTRUMENI 00 1 / AIR RECE0 IVER TRANSCONTROL/MCC j T. -- UTILITY GILDING r G �/GTi E1(ERATOR� NO -POTABLE o ''•TK- ,.J WTR TK a COOLAN 0 ;?7� ill a --- SEPTIC TX RESTROOM as w TK- 0 UO 1 LEACH - r--i - z USED LO v -� TK-1 0 l L IL 7180 I - -_� / + ....H:P. FINISH GRAD' (-- L..-..-..-..-.-_-..-...-.._... ELEV.7180.0' U/G. UTILITY I I CORRIOOR�. TRUCK U/G GAS , , i LL7 — \ TURNAROUND \ AREA I N PUV11 NORTH -- - ` I- 62.4141 - -" -- BLM BOUNDARY �.00, � I D zL .D' sD• I 1 i scale: 1"=20' �LEASE AREA \ \ BOUNDARY i \ N.200' - \\\- S-20/ 8D SILENCER ` S-200 STARTING GAS SILENCER \ _ __00 ENGINE EXHAUST STACK PROPOSED 0.0 I COMPRESSOR STATION PAD AREA (NOTE 4) O j /S�ce yid o�15 o�r I se \ \ 11 ® NA 0 O 0 SLOWDOWN (�Q t I SILENCER / ( / l UfG W SLODOWN LINE (JT 1 ` ESD VALVE; 'c:L, I ///�^^^\\ (NOTE 3� FUEL GA I ` t� STATION D` j SLEEPER RACK (GRAVEL PAO INLET V-zoo F MANUAL \\ l (NOTE 3) SEPARATOR DISCHARGE TK-4 ISOLATION •� 1 ,, I V-100 COALESCER I WASTE TANK. 1 \ ALV _.. _..- 250' DEEP (NOTE 1) ANODE WELL I LVERT _ ` _ --I• — — — 1�RIGATTON CU 71 7150 301� Im 3 CLARIFIED BLM BOUNDARY MJM rvpjs JPW 2 ADDED TRAFFIC BOLLARDS MILI PJS JPW 1 ISSUED FOR CONSTRUCTION SOO PJS JPW 0 FINAL DRAWINGS KLV PJS PW er + + LLJ a 1 DATE PROJECT APPROVAL ISSUED DESCRIPTION PROJ DATE CLIENT DATE 9/9/i3 ISS1JED FOR REVIEW 9/6/1.3 IS9aED 'FR APPROVAL /20/1, • ENGINEERING ti 3/23/13 ISSUED FOR CONSTRUCTION JPW 7/9/13 —.._ SERVICES, LLC 1/20/13 j� REVISED ISSUED FOR CONSTRUCTION PROJECT NO.: CO 180 40 010 1 AFE 1006137 I ° e l l 1 IRRIGATION DIVERTER Sue,►M TO `xCXrMNS&IN GARFEELD COUNTY Blip 1111ITSIG, DEP p4( 1 nt... 2 DY L COPY NO INSPECTION WITHO[ NERAL NOTE THESE PLANS ON SITE: nape of . SNOW STORAGE AREA IS ALONG THE SOUTH SIDE OF SITE. 2. ALL TRUCK LOADING/UNLOADING WILL BE DONE ON SITE. 3. CRANE STAGING AREA DURING CONSTRUCTION. 4. CONSTRUCTION MATERIAL STAGING AREA. 5. SITE LOCATION: NW Y4 NE Y4, SECTION 3, WS, 6TH PM W1116.10m, DWG. NO.: SPV-000-101 GENERAL NOTES.• THE STRUCTURE UNDER THIS CONTRACT HAS BEEN DESIGNED FOR THE LOADS AND CONDITIONS SHOWN ON THESE DRAWINGS. CONSULT B&C STEEL CORP. BEFORE ANY ALTERATION TO THE STRUCTURAL SYSTEM IS DONE OR REMOVAL OF ANY COMPONENT PARTS, OR THE ADDITION OF OTHER CONSTRUCTION MATERIALS OR LOADS. B&C STEEL WILL ASSUME NO RESPONSIBILITY FOR ANY LOADS THAT ARE NOT INDICATED. THIS METAL BUILDING IS DESIGNED IN ACCORDANCE WITH STANDARD PRACTICES WHICH ARE BASED UPON PERTINENT PROCEDURE AND RECOMMENDATIONS OF THE FOLLOWING ORGANIZATIONS & CODES: MATERIAL PROPERTIES OF STEEL PLATE AND SHEET USED IN THE FABRICATION OF PRIMARY RIGID FRAMES AND ALL PRIMARY STRUCTURAL FRAMING MEMBERS (OTHER THAN COLD -FORMED SECTIONS) HAVE A MINIMUM YIELD POINT OF 50 KI.S.1. FOR FLANGE & WEB AS REQ'D. BY DESIGN. MATERIAL PROPERTIES OF HOT -ROLLED MEMBERS (WIDE FLANGE BEAMS, ETC.) SHALL BE MINIMUM 50 K.S.L. MATERIAL PROPERTIES OF COLD -FORMED LIGHT GAGE STEEL MEMBERS CONFORM TO THE REQUIREMENTS OF ASTM A-570, GRADE 55 WITH A MINIMUM YIELD POINT OF 55 K.S.I. STRUCTURAL JOINTS WITH A.S.T.M. A-325 HIGH STRENGTH BOLTS WHERE INDICATED ON THE DRAWINGS SHALL BE ASSEMBLED & THE FASTENERS TIGHTENED IN ACCORDANCE WITH 'TURN -OF -NUT" METHOD AS DESCRIBED IN THE SPECIFICATION FOR STRUCTURAL JOINTS USING A.S.T.M. A-325 OR A-490 BOLTS (11-13-85) UNLESS OTHERWISE NOTED. ALL STEEL MEMBERS EXCEPT BOLTS & FASTENERS SHALL RECEIVE ONE SHOP COAT OF IRON OXIDE CORROSION INHIBITIVE PRIMER (UNLESS SPECIFIED OTHERWISE IN THE CONTRACT DOCUMENTS). PANEL NOTES• FLAT SURFACES MAY DISPLAY SLIGHT WAVINESS. THIS PHENOMENON, KNOWN AS "OIL CANNING" CAN BE CAUSED BY STEEL MILL PRODUCTION TOLERANCES, FABRICATION TOLERANCES AND/OR FRAMING MISALIGNUENT, AND /S NOT A CAUSE FOR REJECT/ON. INSTALLATION OF MATERIAL CONSTITUTES ACCEPTANCE BUILDING LOADS / DESCRIPTION - WIDTH: 50 LENGTH: 120 HEIGHT: 25.5 125.5 (BUILDING DIMENSIONS ARE NOMINAL. REFER TO PLANS). BUILDING LOCATION: GLENWOOD SPRINGS. CO THIS STRUCTURE IS DESIGNED UTILIZING THE LOADS INDICATED AND APPLIED AS REQUIRED BY : IBC 09 THE CONTRACTOR IS TO CONFIRM THAT THESE LOADS COMPLY WITH THE REQUIREMENTS OF THE LOCAL BUILDING DEPARTMENT. ROOF DEAD LOAD: 3 PSF (ROOF PANELS, PURLINS, ETC.) COLLATERAL LOAD: 2 PSF ROOF LIVE LOAD: 20 PSF ROOF SNOW LOAD: 50 -"---,eSF - BASIC WIND SPEED: 90 PH ,EXP: C SEISMIC DESIGN CAT: SEISMIC COEF: 0.560 CRANE INFO (IF APPLICABLE) CRANE TYPE: THE , CAPACITY: 5 TON IMPORTANCE FACTORS: SNOW: 1.00 SEISMIC: 1.25 WIND: 1.15 OTHER DESIGN CONSIDERATIONS: PURCHASER RESPON5/9/L/T/E5.- APPROVAL OF B & C STEEL CORPORATION DRAWINGS INDICATE THAT B & C STEEL CORP. CORRECTLY INTERPRETED AND APPLIED THE REQUIREMENTS OF THE CONTRACT DRAWINGS AND SPECIFICATIONS. WHERE DISCREPANCIES EXIST BETWEEN THE B & C STEEL PLANS AND THE PLANS FOR OTHER TRADES, THE STRUCTURAL STEEL PLANS SHALL GOVERN. (SECT. 4.2.1 AISC CODE OF STANDARD PRACTICE 9TH ED.) DESIGN CONSIDERATIONS OF ANY MATERIALS IN THE STRUCTURE WHICH ARE NOT FURNISHED BY B & C STEEL CORPORATION ARE THE RESPONSIBILITY OF THE CONTRACTORS AND ENGINEERS OTHER THAN B & C STEEL CORPORATION UNLESS SPECIFICALLY INDICATED. BY SIGNING THE APPROVAL DRAWINGS WITH EITHER THE "APPROVED" OR "APPROVED AS NOTED" CHECKED IN THE BOX BELOW, IT IS UNDERSTOOD THAT B&C STEEL CORPORATION WILL PROCEED WITH THE FABRICATION OF THE BUILDING AND IT IS FURTHER UNDERSTOOD THAT THE PURCHASER ACCEPTS THE TERMS AND CONDITIONS OF THE CONTRACT DOCUMENTS AND THE PURCHASER RESPONSIBILITIES LISTED ABOVE. SIDING & ROOFING PANEL STORAGE INSTRUCTIONS. - SIDING & ROOFING PANEL BUNDLES EXPOSED TO MOISTURE SHOULD BE ELEVATED ON ONE END FOR DRAINAGE. BUNDLES EXPOSED TO MOISTURE FOR EXTENDED PERIODS OF TIME SHOULD BE TARPED. COMMON A99Rf-VIA TIONS & PIECE MARKS. 1. EW = ENDWALL) 14. CITY = QUANTITY) 27. G- _ 2. SW = SIDEWALL) 15. QNT = QUANTITY) 28. P- _ 3. SIM. = SIMILAR) 16. EL = ELEVATION) 29. E- _ 4. TYP. = TYPICAL) 17. ELEV = ELEVATION) 30. J- _ 5. BS = BOTH SIDES) 18. F.F. = FINISHED FLOOR) 31. H- _ 6. NS = NEARSIDE) 19. T.O.S. = TOP OF BEAM) 32. DJ- = 7. FS = FARSIDE) 20. DIA. = DIAMETER) 33. DH- = B. SL = STEEL LINE) 21. GA. = GAGE) 34. WJ- = 9. CL = CENTERLINE) 22. EC- = ENDWALL COLUMN) 35. WH- = 10. MF = MAIN FRAME) 23. ER- = ENDWALL RAFTER) 36. LDC = 11. LT = LEAN-TO) 24. RF7-= RIGID FRAME) 37. REQ'D= 12. WF = WIND FRAME) 25, N/A = NOT APPLICABLE) 38. EXIST.= 13. RF = RIGID FRAME) 26. O.C. = ON CENTER) 39. CONC.= 9U/LD/1VG PANEL & COLOR SCHEDULE DESCRIPTION TYPE COLOR GAGE ROOF PANEL B&C "PBR" NEED COLOR 26 WALL PANEL B&C "PBR" NEED COLOR 26 SOFFIT PANEL LINER PANEL PRO -PANEL // White 23% Perforofeo' 26 PARTITION PANEL FACIA FRONT PANEL FACIA BACK PANEL (NOTE-- SOFFIT PANEL COLOR WILL BE WALL PANEL COLOR IF NOT SPEC/F/EDJ 9UILD/NG TRIM COLOR SCHEDULE DESCRIPTION COLOR GABLE / RAKE NEED COLOR EAVE TRIM NEED COLOR GUTTER TRIM NEED COLOR DOWNSPOUTS NEED COLOR CORNER TRIM NEED COLOR FRAMED OPENINGS NEED COLOR INTERIOR TRIM White (NOTE. DOWNSPOUT COLOR WILL BE WALL PANEL COLOR IF NOT SPEC/F/ED/ ACCESSORIES /NCL UDED: QTY: DESCRIPTION: 3 FIELD LOCATED 3o7o 112 GLASS PREP SF WALKDOOR KIT 3 DOOR CLOSER 3 PANIC DEVICE 12 10'-O" CONTINUOUS RIDGE VENTS w/Screens & Dompers PURCHASER: TPI PROJECT: SOURCE GAS - SPRING VALLEY COMPRESSO/' SLOG. JOB NUMBER: 6090 N.U. bUX I UyV - Jl UI I JC3L urr, INLDrV1Jr\,\ uo ju d- i via PH: (308) 632-6188 FAX: (308) 632-7172 REVISIONS: I.D. DESCR/PT/ON DATE NOTE: APPROVAL IS NOT COMPLETE UNLESS THE "NEED UULUK STATEMENTS ARE REPLACED WITH A COLOR. PD 0 L )51 x �s�oNai E� REVIEWED By Richard T Smith at 7:17 pm, Sep 09, 2013 GENERAL NOTES: I. CODES AND STANDARDS IT. PROJECT SHALL CONFORM TO SOURCE GAS PROJECT SPECIFICATIONS AND THE 2009 EDITION OF THE INTERNATIONAL BUILDING CODE (IBC), AND CODES AND STANDARDS CONTAINED THEREIN. ''.DESIGN BASIS - OCCUPANCY CATEGORY III 2.1. GEOTECHNICAL 2.1-I.FORN➢ATION DESIGN IS BASED ON RCCCCMENDATIRNS IN ACCORDANCE WITH GEOTECHNICAL ENGINEERING REPORT NET GS05724-115, DEL THOMPSON, 3/19/2013, AND SUPPLEMENTAL RFl DATED 6/20/2013. SOIL PREPARATION AND CONSTRUCTION DETAILS IN THE REPORT SHALL BE APPLIED AND SUPERSEDE STANDARD PROJECT SPECIFICATIONS. 231.1, MAXIMUM ALLOWABLE SOIL BEARING PRESSURE OF 40OWSF BASED ON MINIMUM 2ri EF MOISTURE TREATED AND COMPACTED STRUCTUPAL FILL. PR PARE SOILS FOR FUTURE COMPRESSOR INERTIA BLOCK 10 MATCH OTHERS. 2.13.2. MINIMUM FROST PROTECTION 36 IN BELOW GRADE 2.1.43. COEFFICIENT OF SLIDING FRICTION 0.33 21.1.4. MAXIMUM ACTIVE SOIL PRESSURE: 50PCF 2.115L MAXIMUM PASSIVE SOIL PRESSURE: 200PCF 2.1.1b. MODULUS CY SUBFRADE REACTION 25OPC1 211.7. SHEAR MODULUS: 2OKS1 2.I3E. POISSONS RATIO. 0.4 21.1.9. SOIL DAMPING RATIO P03 22.EQUIPMENT 2.2.1. EQUIPMENT LOADS USED IN DESIGN ARE AS PROVIDED BY ED'UIPMENT SUPPLIER AND MUST BE VERIFIED PRIOR TO CONSTRUCTION. THE FOLLOWING WEIGHTS ARE USED IN DESIGN 2,211. COMPRESSOR SKID (C-100, C-20W, ISO KIP 22J.2. FUEL GAS SKID (SK-IDO), 55 KIP 22.1.3. SLOWDOWN SILENCCR (S-3003, 2 , KIP 223.4. SLOWDOWN SILENCER (S-101, S-20U, 0.6 KIP Z2.1.5. DISCHARGE COALESCER (V-200), 122 KIP 2216. INLET SEPARATOR (V-100), 152 KIP 22J.7. AIR COMPRESSOR SKID (SK-200), 15 KIP 22:LB. BACKUP GENERATOR SKID (G-IOD, 9.7 KIP 2.21.9. AR RECEIVER (V-3D0), 4.4 KIP Z.2.1.111 ENGINE EXHAUST STACK (ST-CIOq S1-C200), 5.2 .KIP 2ZLIL STARTING GAS SILENCER (S-100, S-201). OS KIP 22.1.12, STORAGE TANK OK-4), 28 KIP z22. SECONDARY CONTAINMCNT 222.1. STORAGE TANK SECONDARY CONTAINMENT SYSTEM SHALL BE DURA LIFE 'DYNAMIC LOADING BY SIWX STEEL CD OR APPROVED EQUIVALENT. INCLUDE FULLY SEALED LINER AND CROSS -DYER STEP ASSEMBLY. 2.3. METAL BUILDING 2.3.1. BUILDING LOADS AND GEOMETRY ARE BASED ON THE FOP -LOWING SUBMITTAL FOR APPROVAL DRAWINGS BY B&C STEEL. SCOTTSBLUFF NEBRASKA, AND MUST RC VERIFIED PRIOR TO CONSTRUCIIUN- 2.11.1. COMPRESSOR BUILDING, 3/1672012. 2.3.12. UTILITY BUILDING, 3/15/2012. 2.113. CONTROL BUILDING, 3/19/2012, 2A.LIVE LEAD 2AL MAT SLABS: 250PSF 2A2, ELEVATED PLATFORMS: 60PSF 2.43. STAIRS, IOOPSF 2.4.4. BRIDGE CRANE: 5 TON 25.WIND DESIGN 2.S.1, BASIC WIND SPEED: 90MPR 2.52, EXPOSURE: C 2.6, SNOW LOAD ._ ROOF SNOW LOAD 50PSF 'iCSMIC PARAMETERS 2.7A SHORT PERIOD RESPONSE, Spy 0.359 2.7.2. SITE CLASS: D 2.7.3 SEISMIC DESIGN CATEGORY. C 2.7.4. RESPONSC MODIFICATION FACTOR, R: 20 2.7.5 OVERSTRENGTH FACTOR, 9,: 2.0 MATERIALS 3.1. STORE, PREPARE AND INSTALL ALL MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND/OR APPLICAB:.E STANDARD 3.2.COCRETE 32.1. DESIGN AND PLACE CONCRETE AND REINFORCEMENT PER AMERICAN CONCRETE INSTITUTE (ACT) 318, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE. 3.22, CONCRETE WORK TO CONFORM 10 ACT 301, SPECIFICATIONS FOR STRUCTURAL COCREIC. COMPLY WITH ACT 305 FOR HOT WEATHER CONCRETING AND ACT 306 FOR COLD WEATHER CONCRETING AS APPROPRIATE. 32.1 MINIMUM ES -DAY CUMPRESSIVE STRENGTH OF CONCRETE SHALL BE 40ODPS1 FOR KAI SLABS, INERTIA BLOCKS, AND SLAB -ON -GRADE, 300OPS1 FOR OTHER. 3.2.4. ALL REINFORCEMENT SHALL BE DEFORMED BARS CONFORMING TO ASTM AGIS 34S MINIMUM YIELD STRENGTH FOR CONCRETE REINFORCING SHALL BE 40 KS] FOR B4 AND SMALLER, AND 60 KSl FOR LARGER BARS. 326. ALL REINFORCING PLACCD BELOW GRACE OR EXPOSED TO EARTH SHALL INCLUDE AN APPROVED GALVANIC CORROSION PROTECTION SYSTEM. 32.7, ALL REINFCRCCNET SHALL BE CONTINUOUS OR WITH MINIMUM CLASS-0 LAP SPLICE UNLESS OTHERWISE NOTED. ALL MAI SLAB REINFORCING SHALL TERMINATE AT SLAB EDGES WIN STANDARD HOOK. 328. ALL REINFORCING SHALL BE COL➢ BENT AND SECURELY TIED IN PLACE USING GALVANIZED OR PLASTIC ACCESSORIES INCLUDING SLAB ON GRADE BAR BOLSTERS. 3.2.9. MINIMUM CONCRETE COVER SHALL BE 1-1/2' FOR 45 AND SMALLER, AND 2' FOR LARGER BAGS WHERE EXPOSED TO EARTH OR WEATHER AND 3' WHERE CAST AGAINST EARTH UNLESS OTHERWISE NOTED 3.2.10. JOINT SEALANT FOR ALL CONCRETE CONTROL, CONSTRUCTION AND ISOLATION .RUNTS SHALL BE SIKAFLEX-IC BY SIKA CORE, OR APPROVED EOUAVALENT. 3.2.17. CHAPTER ALL EXPOSED CORNERS 3/4' UNLESS OTHERWISE NOTED. 3.2.12. COORDINATE ALL PROJECT DRAWINGS FOR EMBEDDED ITEMS (PIPE, CONDUIT, EIC.) AND DLO3(DUTS BEFORE PLACING CCNCROTE, 3.213. VERIFY ALL EQUIPMENT ANCHOR BOLT PLACEMENTS AGAINST THE CERTIFIED BUILDING AND EQUIPMENT DRAWINGS BEFORE PLACING CONCRETE- TOLERANCES FOR ANCHOR BOLT LOCATIONS AND ELEVATIONS SHALL BE AS DEFINED IN THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISG CODE OF STANDARD PRACTICE. 3.2.14, MOIST -CURE ALL CONCRETE FUR A MINIMUM OF 7 DAYS OR CURE BY USE OF AN APPROVED MEMBRANE COMPOUND. 32.15. GROUT STRUCTURAL STEEL COLUMN AND EQUIPMENT BASE PLATES AND ANCHOR SLEEVES WITH MINIMUM DESIGN STRENGTH 6000 PSI PRE -PACKAGED NDN-SHRINK GR1IU7 SUCH AS SIKAGRDUT 329 BY SIKA CORP., OR APPROVED EO)AVALENT. 3.216. PROVIDE LNISORB 1B-500 OR APPROVED EQUIVALENT COTIIUQUS VIBRATION ISOLATION PIT LINER WITH SEALED SEAMS AT INERTIA RLDCK LOCATIONS WITH A DESIGN NATURAL FREQUENCY OF 4-BHZ. 33 STEEL 3.3.1. DESIGN, FABRICATE AND ERECT STRUCTURAL STEEL IN ACCORDANCE WITH THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISG MANUAL AND OSHA STANDARDS. 3.32 PROVIDE TEMPORARY SUPPDRT BRACING AND SAFE LIFTING SCHEMES FOR ALL HIGH STRENGTH BOLTING AND FIELD WELDING REQUIRES SPECIAL INSPECTOR. PROVIDE APPROVAL REPORT AT FRAMING INSPECTION EQUIPMENT AND STEEL AS REQUIRES DURING ALL PHASES OF CONSTRUCTION, EXTEND ALL LONG. REINF. 3.3.3 ALL STRUCTURAL STEEL SHALL BE PRIMED AND PAINTED PER PRJJECF Z -6" MIN. BEYOND JOINT SPECIFICATIONS. ALL ANCHORS EMBED-LD OR POST-1RSTALLED IN CONCRETE SHALL BE GALVANIZED 3.34. ALL ➢OLTEO CONNECTIONS SHALL BE IN CU14FBRMANCE VITH. AISC'S SPECIFICATION FOR STRUCMITTS TS USING NIGH STRENGTH BOLTS. T.O. SLAB 3,3.5 WELDING SHALL CONCURN 10 AMERICAN WELDING SOCIETY (AWS) DLI -� RE: PLAN STRUCTURAL WELDING CODE. ALL WELDING SHALL BE PERFORMED BY CERTIFIED WELDERS QUALIFIED BY THE AVS STANDARD WALIFICAiION PROCEDURE 3.34 SPECIFICATION 32,63. WIDE FLANGE SCANS. ASTM A-992, FY=50(SI 3.3.6.2. CHANNELS, ANGLES, PLATES, GRATING, BARS AST" A-36, FY-36XS1 3.3.61. HIGH STRENGTH BITS: ASTM A325 3.36.4. HEAVY HEX NUTS. ASTM A563 3.365. WASHERS ASTM F436 3.3.66. ANCHOR BOLTS, ASTM F1554 13.6.7. WELDING ELECTRODES: E70xx 336A POST-INSIALLED ANCHORS MILT[ KWIK-BOLT TZ DETAIL 4-SUBMITTALS SCALE 3/4" 4.1. IN ADDITION TO PROJECT AND LOCAL BUILDING DEPARTMENT REQUIREMENTS, CONTRACTOR SHALL PROVIDE THE FOLLOWING SUBMITTALS TO SOURCE GAS PROJECT MANAGER AND PROJECT STRUCTURAL ENGINEER OF RECORD FOR APPROVAL PRIOR 10 CONSiRUCTiO 4.13. CERTIFIED EQUIPMENT AND METAL BUILDING DRAWINGS. 412. CONCRETE MIX DESIGNS 4,L3 CONCRETE REINFORCING SH3P DRAWINGS 4.1.4. STRUCTURAL STEEL SHOP DRAWINGS 4.IS. VIBRATION ISOLATION LINER SPECIFICATIONS AT 6. GALVANIC CORROSION MITIGATION SYSTEM SPECIFICATIONS 4.17. SECONDARY CONTAINMENT SYSTEM SPECIFICATIONS 5. STRUCTURAL TESTS AND SPECIAL INSPECTIONS 5.1, APPROVED AGENCIES SHALL PROVIDE STRUCTURAL TESTS AND SPECIAL INSPEC71DNS WRING CONSTRUCTION IN ACCORDANCE VITH IBC fHAP7CR i7 INCLUDING THE FOLLOWING 5.13. FABRICATION, SECTION 17D4P. OPEN -HOLE SOILS REPOK I 5,12- STEEL CONSTRUCTION, SECTION )7043. 5.1.3, CONCRETE ECINSIRUC TILIN, SECTION 170CC IS REQUIRED AT FOOTING 5AA, FOUNDATION SOILS. SECTION 17047. INSPECTION ���� PSF 5.15, PIPING SYSTEMS, SCCTIGN 1707.7.3. 52 ALL TEST AND INSPECTION REPORTS SHALL BE SUBKIITED TO SOURCE GAS PROJECT MANAGER AND PROJECT STRUCTURAL ENGINEER OF RECORD. 6 STRUCTURAL OBSERVATIONS 6.1.CONTRACTOR SHALL NOTIFY SOURCE GAS PROJECT MANAGER. AND THE PROJECT STRUCTURAL ENGINEER OF RECORD AT LEAST 3 DAYS IN ADVANCE OF POURING FOUNDATION CONCRETE TO SCHEDULE REDO PLACEMENT OBSERVATIONS. SOURCE GAS REPRESENTATIVE AND/OR ENGINEER OF RECORD MUST APPROVE PLACEMENT OF FOUNDATION REINFORCING AND EMDEDKENTS, IN ADDITION 10 DCSIGNAiLD SPECIAL INSPECTION AGENCY, PRIOR TO POURING CONCRETE 62CONTRACTOR SHALL NOTIFY SOURCE GAS PROJECT MANAGER AND THE PROJECT STRUCTURAL ENGINEER [IF RECORD UPON SUBSTANTIAL COMPLETION OF STRUCTURAL STEEL ERECTION AND PIPING AHD EQUIPMENT INSTALLATION TO COORDINATE FINAL VALKOUVN. 7. COORDINATION 7.1 THE CONTRACTOR SHALL REVIEW AND COORDINATE ALL PROJECT DOCUMENTS AND FIELD CONDITIONS. THE CONTRACTOR SHALL NOTIFY SOURCE GAS PROJECT MANAGER AND THE PROJECT STRUCTURAL ENGINEER OF RECORD IMMEDIATELY IF DISCREPANCIES OR MODIFICATIONS ARE REQUIRED TO THE DESIGN o Z NOTE: AQUIRE ENGINEER OF RECORD APPROVAL FOR JOINT LOGS. ABBREVIATIONS SYMBOL DESCRIPTION T.O.C. TOP OF CONCRETE T.O.S. TOP OF STEEL T.O.F. TOP OF FOOTING E.O.P. BOTTOM OF PLATE U.N.O. UNLESS NOTED OTHERWISE E.W. EACH WAY T&B TOP AND BOTTOM E.F. EACH FACE EL ELEVATION K KIP (1.000 LEIS) N.T.S. NOT 70 SCALE LLV LONG LEG VERTICAL CONS. CONTINUOUS PROVIDE IY' X 3Y CONT. KEY W/ Y4" MIN. AMPLITUDE ROUGHENED SURFACE AND BONDING AGENT AT JOINT RE: TYP. MAT SLAB DETAIL FOR CONST. TYP. MAT SLAB CONST. JOINT ANCHOR JADED BOLT ANCHOR BOLT SCHEDULE DIA. GRADE MIN. EMBED. 36 5" " 36 6" 36 B` 1" 36 12" DETAIL - TYP. ANCHOR BOLT 4 SCALE N.T.S. llOO1 BASE BEAU k 4 x O'-4' SPACER W/ %" 0 HOLE -a 2 .2'. 2' PL 3/4-x4x0'-6" CLIP PLATE W/7/8.0 HOLE DETAIL - CLIP ANCHOR r6'� SCALE N.T.S. Q01 NHLTI K61K-BOLT MONOLITHIC SLAB ON COMPACTED STRUCTURAL FILL -� T.O. SLAB RE: PLAN DETAIL - TYP. MAT SLAB T SCALE 3/4 I'-0' OOt NOTE: HOOK MAIN REINFORCEMENT AT END OR PROVIDE CORNER BAR AS SHOWN. Q DETAIL - TYP. CORNER BAR REINFORCING SCALE N.T.S. HEAVY HEX HEM SON ANCHOR SLEEVE OR PROVED EQUIVALENT FULLY GROUTED DETAIL - SLEEVED ANCHOR s SCALE N.T.S. OO � NWIK-COLT. DETAIL - EXPANSION ANCHOR %7 SCALE N.T.S. OD1 REV REVISION DESCRIPTION BY CHK APP DATE REV REVISION DESCRIPTION BY CHK APP DATE 6 w z N`^7Noo ����� � � � 0 a Ir o a a i o N o PROJECT APPROVAL , Sourt Gas SPRING VALLEY COMPRESSOR STATION STRUCTURAL CEN.PRAL �„OTE.0 O&TYPIC„L DETP,II SENGINEER{NG ISSUED DESCRIPTION PROD DATE CLIENT DATE ISSUED FOR REVIEW ISSUED FOR APPROVAL SERVICES, LLC ISSUED FOR CONSTRUCTION 0 ISSUED FOR CONSTRUCTION BSF MTM 8/5/13 REVISED ISSUED FOR CONSTRUCTION PROJECT NO.: CO 180 40 GI AFE: 1006137 DWG. N0.• SPV-300-001 J,