HomeMy WebLinkAboutPlansI CONSULTANT: SYMBOLS LEGEND STRUCTURAL o0 DOOR MARKER GRIDLINE MARKER DETAIL BUBBLE & oo WINDOW MARKER 00 xo.a MARKER A\ REVISION NUMBER 0o ELEVATION xo.o MARKER 00 KEYED NOTE MARKER SECTION wo WALL TYPE MARKER D0 MARKER ------ ACCESSIBLE PATH OF ROOM NAME ROOM NAME & TRAVEL INDICATOR OR MEANS OF EGRESS 00 NUMBER MARKER PATH INDICATOR 000 :ooNT SPOT ,XX.YY > FINISH TRANSITION ELEVATION - 00 EGRESS O.o° oo° MARKER NOTE TO CONTRACTOR CODE PLAN KEY: ROOM NAME O00OCCUPANTLOAD #k# SF ROOM AREA EXISTING 1-HR FIRE RATED WALLASSEMBLY THE CONTRACTOR SHALL VISIT THE JOB SITE, VERIFY ALL EXISTING CONDITIONS, AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES PRIOR TO SUBMITTING A BID AND/OR BEGINNING ANY CONSTRUCTION WORK. CODE INFORMATION BUILDING CODE: 2015 INTERNATIONAL BUILDING CODE PLUMBING CODE: 2015 INTERNATIONAL PLUMBING CODE MECHANICAL CODE: 2015 INTERNATIONAL MECHANICAL CODE FUEL GAS CODE: 2015 INTERNATIONAL FUEL GAS CODE ELECTRICAL CODE: 2017 N.E.C. ENERGY CODE: 2009 INTERNATIONAL ENERGY CONSERVATION CODE FIRE PREVENTION CODE: 2015 INTERNATIONAL FIRE CODE ACCESSIBILITY CODE: 2010 ADA A.) USE & OCCUPANCY CLASSIFICATION: ✓ 12, Group: Occupancy Group o Area: 6,703 SF B.) GENERAL BUILDING HEIGHTS & AREA Existing Building Area: 14,770 SF Proposed Use(s): Occupancy GrouptI Most Restrictive Use: Occupancy Group - Jh Allowable Height: 55'-0" / 2 Stories Allowable Area: 9,500 SF-—' Area Modification: Q� o Frontage Increase:wl� OVERALL AREA DISTANCE: 119'-7 3/8" MIN. EXIT DISTANCE ALLOWED: (overall area distance)(y)= x y=112 w/o sprinkler OR 113 w7 sprinkler (X'-)C') (1/2) = x (119'-7 3/8") (1/2) = 59'-9 5/8" amnca-n/ > 59'-9 5/8" z z 1 t Oe*9 12., to `b C W 60 ' EXTERIOR TRAVEL 11.9" 36 DISTANCE: ' 45'-2" UTILITY UTILITY ,162 SF FREE WEIGHTS -NO i EAERCII UIN74 FSta I MULTIPURPOSE ROOM I 670 SF T rTRAVEL �I i DISTANCE:39'-6" FUNCTIONAL TRAINING ERCIS 1,311 SF ' I JI' � � :50 8 �� t 1,733 SF \ 89 SF MEMBER AREA BUSINESS 272 SF F I 2 k r OAS �Q TENTRA T USINES T�AINE PLAN F_ USINES \ 6 SF BU 51 SF CODE COMPLIANCE PLAN an911 = 1,_n" If = (F/P - 0.25) x W130 If=(484/484-0.25) x3°moo If=.75 ABBREVIATIONS o Areal crease: Aa = (At + (Ns x /U Aa = [9,500 + (9,500 x. 75)] Aa = 16,625 CENTER LINE INSUL. INSULATION Full Building Automatic Fire Sprinkler System: No NonseparatedOccupancies j1, 41- 3A SIW� ex S�AbtKC"s @ AT MANUF. MANUFACTURER C.) TYPES OF CONSTRUCTION: A.C.T. ACOUSTIC CEILING MAX. MAXIMUM Type:ll-B TILE MECH. MECHANICAL Required Fire -Resistive Ratings: A.F.F. ABOVE FINISH MIN. MINIMUM BUILDING ELEMENT RATING FLOOR MISC. MISCELLANEOUS Structural Frame 0 Bearing Walls - Exterior 0 ADJ. ADJACENT MTL. METAL Bearing Walls - Interior 0 APX. APPROXIMATELY Nonbearinq Walls - Exterior Nonbearinq Walls - Interior 0 N.I.C. NOT IN CONTRACT 0 Floor Construction 0 B.O. BOTTOM OF N/A NOT APPLICABLE Roof Construction 0 BD. BOARD NC = Noncombustible BLDG. BUILDING O.C. ON CENTER D.) INTERIOR FINISHES: BLKG. BLOCKING OPNG. OPENING Required Interior Wall & Ceiling Finish Classifications: FINISH CLASSIFICATION C.M.U. CONCRETE PLMBG. PLUMBING TYPE OF&SPACE Rooms Enclosed Spaces C ' MASONRY UNIT PLYWD. PLYWOOD CLG. CEILING A v C' [ny�r I COL. COLUMN REQ'D REQUIRED E.) MEANS OF EGRESS: �MWLI - r` 7 Minimum Number Of Exits Required = 2 Exits CONC. CONCRETE REV. REVERSE Minimum Exit Width Required: 119 x 0.2" = 23.8" CONT CONTINUOUS J9 I271 SF 6O TRAVEL EXTERIOR - DISTANCE:63'-10" 11.9" 72" J 2 I GLJ low z 7� Z " Lu � W FY Z F ¢ o, h, w, �, rA 27eW_ V •� aiv T i iiv�� 7025 Highway 82 Glenwood Springs, Colorado 81601 CONDITIONS TO PERMIT Anytime Fitness YDD LLC BLCO-09-18-5437 I. All Work to Comply with 2015 IBC, IPC, IMC, IFGC, 2009 IFC and IECC. 2. Building is Considered Type IIB Separated Use per Sec 508.3.3 (Unless Fire Sprinkler System is Installed). Tenant Finish is an A-3 Occupancy. 3. All Electrical as per State Electrical Inspector. 4. Building Must be Accessible as per Chapter 11 IBC and ICC A117.1. 5. Local Fire District to Review and Inspect all IFC Requirements. Rough- in Required for Alarms and Sprinklers Prior to County Rough- In Inspections. Final Inspection by Fire District Required Prior to County Final Inspection. 6. Two Hour Fire Rated Fire Barrier Occupancy Separation Required between Existing KTM Tenant and Anytime Fitness. Table 508.4 and Sec 707 IBC. See Section 714 for Penetrations. Provide Approved Fire Assembly Design Prior to Framing Inspection. 7. See Reclined Items for Other Requirements. PROJECT TEAM SHEET INDEX Current CLIENT:Sheet NO. Sheet Name ROARING FORK FITNESS LLC (d/b/a ANYTIME FITNESS) ReVISIOn 0091 RIVER BEND WAY GLENWOOD SPRINGS, CO 81601 PHONE NUMBER: (520) 850-95 IAO.0 Cover Sheet CONTACT: KEVIN GRENIER7�P4 � gj� B1.0 Accessibility Standards LANDLORD: APOPROVED LJ YYD LLC 132 PARK AVE. O i OTP-0 . A2.0 Architectural Floor Plan BASALT, CO 81621 )(�'`.'p�r-G i� 4N& PHONE NUMBER: (970) 927 40 A3.0 Reflected Ceiling Plan CONTACT: CHRIS JUNG Ft�jr t' Ir; A4.0 Interior Plan ARCHITECT: OIL (r���` AJ.O Schedules & Wall Types MICHAEL J. WILKUS, ARCHITE T DATE- 15 NINTH AVENUE NORTH AB.O Interior Elevations HOPKINS, MINNESOTA 55343 A7.0 Details PHONE NUMBER: (952) 843-505 CONTACT: BRITTANYBAUER e,`r t, i i A7,1 Details EMAIL: BMB@WILKUSARCH.C�� ; A7.2 Details €.- -•- - ( A8.0 Specifications DUNHAM ASSOCIATES, INC. 50 SOUTH SIXTH STREET, SUITE 1100 MINNEAPOLIS, MINNESOTA 55402 PHONE NUMBER: (612) 465-7550 CONTACT (ELEC): CULLEN MURTAUGH Maximum Exit Travel Distance Allowed = 200'-01111.1' j n LOCATION MAP n KEY PLAN CONTACT (MECH. & PLMBG.): JACOB BURSOTT Occupant Load Calculations: AREA PER OCC. SHT. SHEET A0 ° NOT TO SCALE FUNCTION OF SPACE AREA OCC. LOAD DIM DIMENSION(S) SIM. SIMILAR A0.0 NOT TO SCALE BUSINESS AREA DWG. DRAWING SPEC. SPECIFICATIONGuest Member Area 272s.f: SQ. FT. SQUARE FEET PREFERRED VENDOR LIST Manager's Office 126 s.f. EA. EACH STD. STANDARD Trainer 85 s.f. ELEC. ELECTRICAL STL. STEEL Tanning 89 s f A ELEV. ELEVATION Changing 65 s.f. STRUCT. STRUCTURAL Changing 65 s.f.S,Iwt� EQ. EQUAL SUSP. SUSPENDED Hall 235 s.f. EXIST. EXISTING Unisex 74 s.f. EXT. EXTERIOR Unisex 75 s.f. T.O. TOP OF Unisex 68 s.f. TYP. TYPICAL TOTAL: 1,425 s.f. 100/OCC. 15 F.O.S. FACE OF STUD F.O.S.F. FACE OF EXERCISE AREA U.N.O. UNLESS NOTED Cardio/ Strength 1,733 s.f. STOREFRONT r �{- OTHERWISE Free Weights 1,402 s.f. ,vr F.O.W. FACE OF WALL Functional Area 1.311 s.f. ` F.R.P. FIBERGLASS Multipurpose Room 670 s.f. V.I.F. VERIFY IN FIELD TOTAL: 5.116 s.f. 50/OCC. 103 REINFORCED PANEL FIN. FINISH V.T.K VIRTUAL TRAINER MECH. EQUIPMENT AREA KIOSK Utility 162 s.f. FLR. FLOOR VERT. VERTICAL TOTAL: 162 s.f. 300/OCC. 1 FT. FEET ANYTIME FITNESS TOTAL: 6,703 s.f. % W/ WITH ANYTIME FITNESS TOTAL OCCUPANT LOAD: 119 G.C. GENERAL WD. WOOD CONTRACTOR F.) PLUMBING FIXTURE REQUIREMENTS: GYP. GYPSUM Male Occupant Load: 60 Female Occupant Load: 60 Plumbing Fixture Count Calculations: H.V.A.C. HEATING, FIXTURE TYPE REQUIRED PROVIDED UNISEX VENTILATION & AIR Water Closet M: 1/1 25= 1 / F: 1 /65= 1 3(Unisex) CONDITIONING Lavatory M:1/200=1 / F: 1/200=1 3 (Unisex) Service Sink 1 1 HGT. HEIGHT Drinking Fountain 1/500=1 1 HORIZ. HORIZONTAL PRODUCT SERVICE VENDOR CONTACT PHONE EMAIL ADDRESS FLOORING/ TILE/ SHAW INTEGRATED ARAMENTAADAMS (800) 338-9479 ANYTIME.FITNESS@SHAWINC.COM 616 DUVALL ROAD STONE SOLUTIONS JUNCKERS SPORT AND (SISSY) CHATSWORTH, GEORGIA 30705 WOOD FLOORING ARAMENTA ADAMS (800) 338-9479 ANYTIME.FITNESS@SHAWINC.COM 616 DUVALL ROAD DANCE FLOOR SYSTEMS ECORE (SISSY) (515) 450-2144 MATT.KOCH@ECOREINTL.COM CHATSWORTH, GEORGIA 30705 RUBBER/ TURF 715 FOUNTAIN AVENUE INTERNATIONAL, INC. (952) 641-9600 JENNYK@4RCHETYPESIGN.COM LANCASTER, PENNSYLVANIA 17601 SIGNAGE INTERIOR ARCHETYPE JENNY KRUSE 9635 GIRARD AVENUE S. GRAPHICS (763) 856-0217 DSCHARBER@GLOBALRETAILENVIRONMENTS.COM MINNEAPOLIS, MINNESOTA 55431 MILLWORK/ WALL GLOBAL RETAIL DENISE SCHARBER P O BOX 2582E 7TH PROTECTION ENVIRONMENTS (314) 633-0567 i JUSTIN.LOWDER@VILLALIGHTING,COM ZIMMERMAN, N, MINNESOTAA 55398 2929 CHOUTEAU AVENUE LIGHTING VILLA LIGHTING JUSTIN LOWDER DAVID FOSS (515) 422-2688 DAVID.FOSS@VlLLALIGHTING.COM (651) 731-7142 BHAEN@TCHCO.COM ST. LOUIS, MISSOURI 63103 723 HADLEY AVENUE N. DOORS, FRAMES, HARDWARE TWIN CITY HARDWARE BOB HAEN OAKDALE, MINNESOTA 55128 ROLLER SHADE ROLL A SHADE RIC BERG (951) 245-5077 x 113 RIC.BERG@ROLLASHADE.COM 12101 MADERA WAY RIVERSIDE CALIFORNIA 92503 A8.1 Specifications P1 Plumbing Riser Diagram & Schedules M1 HVAC Plan M2 HVAC Schedules and Notes M3 HVAC Specifications E1 Electrical Power Plan E1.1 Electrical Notes E2 Electrical Lighting Plan E3 Electrical Riser Diagram & Schedules E4 Electrical Specifications LOW1 Low Voltage Floor Plan LOW2 Low Voltage Plan SEPARATE / DEFERRED SUBMITTALS: SIGNAGE OW MTY'Le WILKUS 15 Ninth Avenue North, Hopkins, MN 55343 Phone: 952.941-86601 ww *Ikusarchxonn CLIENT AA Pi r T i A h I rl 1 IVCS: SELF ESTEEM BRANDS, LLC 111 WEIR DRIVE WOODBURY. MINNESOTA 5512 I PROJECT INFORMATION. O CD Ir— CO N0 co Q Cn Z _L = U) Lo its Np O J 0 °¢ cot n oC>• MICHAEL J. WILKUS, ARCHITECT LICENSE NUMBER: 303890 EXPIRATION DATE: 10-31-2019 2018,08.30 PROJECT NO.: 2018-0797 _ DRAWN BY: LG CHECKED BY: BB - ISSUE: DATE: PERMIT SET 201&08.3 REVISION: � - of Ln ---- C6 - Cn 77 Cn o � � o M - J m � _ cM PROJECT LOCATION: C4 GLENWOOD N SHEET NU TITLE: G AC Cover Sh G to G m GENERAL NOTES CONSULTANT: 1. ALL DIMENSIONS ARE TO FACE OF WALL, FACE OF EXISTING CONSTRUCTION U.N.O. 2. REFER TO SHEET A4.0 FOR ALL WALL & FLOOR FINISHES 3. REFER TO MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION 4. REFER TO THE LATEST ANYTIME FITNESS DESIGN MANUAL FOR ALL REQUIRED FURNITURE AND ACCESSORIES - GENERAL CONTRACTOR TO ASSEMBLE AND INSTALL OWNER SUPPLIED FURNITURE - VERIFY QUANTITIES WITH OWNER ARCHITECTURAL PLAN KEYNOTES OEXIST. STRUCTURAL STEEL COLUMN TO 13 PROVIDE POSITIVE SLOPE TO SHOWER FLOOR REMAIN - PROTECT - PAINT 13 DRAINS - IF SLAB IS EXISTING, REMOVE PORTION OF SLAB AS NEEDED AND REPOUR TO REQ'D SPECIFICATIONS - COORDINATE SLOPES CBEVELED R LOC. - REFER TO EL WG HRESHOLD - 1/2" MAX. RISE W/ SIDES THAT SLOPE 1:2 MAX - E 1/2" SADDLE AT ALL THRESHOLDS UT TILE ORETAIL/ LOGO WALL ASSEMBLY TO EXTEND TO UNDERSIDE OF EXISTING ROOF ASSEMBLY O5 WALL MOUNTED FIRE EXTINGUISHER -VERIFY FINAL LOC. W/ LOCAL FIRE MARSHALL 6 DASHED LINE INDICATES CLG. TRANSITION ABOVE OVIRTUAL TRAINER KIOSK - SYSTEM PROVIDED 7 & INSTALLED BY OWNER - G.C. TO PROVIDE POWER & ROUGH -IN - REFER TO ELEC. DWGS. OSERVICE SINK W/ MIXING VALVE - REFER TO PLMBG. DWGS. OPROVIDE 8'-0" HIGH F.R.P. WAINSCOT 4'-0" BEYOND LIMIT OF SERVICE SINK AT WALLS SURROUNDING SERVICE SINK 10 WATER HEATER - REFER TO PLMBG. DWGS. 11 PROVIDE MIRRORS ALONG F.O.W. AS INDICATED - FROM 2'-0" TO 8'-0" A.F.F. OALFP COMMUNICATION KIT TIMER LOCATION - 12 G.C. TO PROVIDE RECESSED OUTLET - REFER TO ELECTRICAL DRAWINGS WALL TYPES S. W/ FLOORING CONTRACTOR TO ACHIEVE CLEAN, SMOOTH TRANSITION - REFER TO 1/A7.1 14 RESTROOM FLOOR DRAIN - REFER TO 9/A7.2 < 15 24" WIDE FULL-LENGTH MIRROR IN STAINLESS STEEL FRAME & STAINLESS STEEL SHELF VERIFY LOCATION W/ OWNER - REFER TO 18/A7.0 LOCATION OF TV - G.C. TO PROVIDE & INSTALL <\16 ? POWER & DATA - REFER TO ELEC. DWGS. - OWNER TO PROVIDE & INSTALL TV'S & MOUNTS - REFER TO 3/A7.2 FOR BLKG. DETAIL - TYP. 17 ELECTRICAL EQUIPMENT SHOWN FOR REFERENCE - REFER TO ELEC. DWGS. FOR MORE INFORMATION - PROTECTAND MAINTAIN REQUIRED CLEARANCES /18 VERIFY CENTER MULLION - IF ONE DOESN'T \� EXIST, ADJUST STOREFRONT AS REQUIRED TO ALLOW FOR CENTER STRIKE MULLION - REVISE DOOR HARDWARE IF REQUIRED - REFER TO 8/A7.1 NEW STEPPED WALL - REFER TO DETAILS ON �' SHEET A6.0 FOR ADDITIONAL INFORMATION i� GC TO PREPARE EXISTING SLAB AS REQUIRED 0 TO MAKE SURFACE LEVEL TO MEET ALL FLOOR FINISH MANUFACTURER'S INSTALLATION RECOMMENDATIONS. *PROVIDE SOUND BATT INSULATION WITHIN WALL ASSEMBLY- REFER TO FLOOR PLAN FOR LOCATIONS *AT ALL SHOWERS REPLACE MOISTURE RESISTANT GYPSUM BOARD WITH CEMENTITIOUS SHEATHING *PROVIDE BLOCKING/BACKING AS REQUIRED - REFER TO GENERAL NOTES ON SHEET A5.0 *REFER TO SHEET A7.2 FOR ADDITIONAL INFORMATION ALL WALLS REPRESENTED IN PLANS AS FOLLOWS: EXISTING WALL CONSTRUCTION TO REMAIN (EXISTING WALLS TO BE LEVEL 4 FINISH) NEW METAL STUD WALL- EXTEND WALL TO DECK ®� •- LINE INDICATES TOP OF WALL AT 9'-6" A.F.F. SEE F SEE MTL. STUD ANGLE BRACING @ 48" O.C. ALTERNATING SIDES - EXTEND TO DECK EXTEND GYP. BD. TO DECK WHEN THERE IS NO CEILING - REFER TO A3.0 3-5/8" METAL STUDS @ 16" O.C. 5/8" GYP. BD, EACH SIDE MTL. STUD ANGLE BRACING @ 48" O.C. ALTERNATING SIDES - EXTEND TO DECK RCP EXTEND GYP. BD. TO DECK WHEN THERE IS NO CEILING - REFER TO A3.0 5/8" MOISTURE RESISTANT GYP. BD. (PAINT) (2) LAYERS OF 3-5/8" METAL STUDS @ 16" O.C. 1R 518" GYP. BD. INTERIOR PARTITION Y WALL TYPE VARIES - REFER TO ARCHITECTURAL FLOOR PLAN AND DETAILS FOR ADDITIONAL INFORMATION SEE FLOC RESTROOM SIDE MTL. STUD ANGLE BRACING @ 48" O.C. ALTERNATING SIDES - EXTEND TO DECK EXTEND GYP. BD. TO DECK WHEN THERE IS NO CEILING - REFER TO A3.0 5/8" GYP. BD, 3-5/8" METAL STUDS @ 16" O.C. 5/8" MOISTURE RESISTANT GYP. BD. (PAINT) RESTROOM SIDE — MTL. STUD ANGLE BRACING @ 48" O.C. ALTERNATING SIDES - _ CLG. EXTEND TO DECK SEE RCP EXTEND GYP. BD. TO DECK WHEN THERE IS NO CEILING - REFER TO A3.0 5/8" GYP. BD. 6" METAL STUDS @ 16" O.C. 5/8" MOISTURE RESISTANT GYP. BD. FLOOR _ ' (PAINT) W6; INTERIOR PARTITION 1Nfia INTERIOR PARTITION i GYP. BD. 1-SIDE ONLY -9 ` eb1 ` ;*) ?fk (Y rw c� -t i��Q ��iC 1�xri J�4�S Sites k., S tz.to, z S'Q4, 7 oq-K z _ �l �- F/iu AL e 2 IPAIIIIIJILLrL sae / Z10 DO TAegm V � (SO4° 3) �4xJ Duo ee ��-rYo A--3 T. � &'�V.K— OCC WJLKUS 15 Ninth Avenue North, Hopkins, MN 55343 Phone: 952.941.86601 www.wilkusarch.com CLIENT: A& Ift ■W 144, L.11V T 1 11MIC F1 1 IvE» SELF ESTEEM BRANDS, LLC 111 WEIR DRIVE WOODBURY. MINNESOTA 55125 PROJECT INFORMATION: SEAL V_ O V_ OD CV 0 3:Z _ co Lr) 0 CV p O o Z W J -0 X m-3$90 1, • MICHAEL J. WILKUS, ARCHITECT LICENSE NUMBER: 303890 EXPIRATION DATE: 1031-2019 2018.08.30 DATE PROJECT NO.: 2018-0797 DRAWN BY: LG CHECKED BY: BB JISSUE: DATE: PERMIT SET 2018.08.30 __DATE PROJECT LOCATION: GLENWOOD SPRINGS, CO W4 INTERIOR PARTITION ARCHITECTURAL FLOOR PLAN 3/1 H" = 1' U" Am` WR7Q iL. to/o .1, 10 SHE E BER I TITLE: A2.0 Archi Ural Floor Plan I CONSULTANT: ELECTRICAL PERMITTING & INSPECTIONS ARE BY THE COLORADO STATE ELECTRICAL BOARD S? --ttrz ELECTRICAL ROUGH IN APPROVAL IS REQUIRED AT FRAMING INSPECTION ELECTRICAL FINAL APPROVAL IS REQUIRED AT COIFINAL INSPECTION P1-30,32,34,36 P1-38, 40, 42 1-1/4"C. (10) #10 & (1) #10 GND. P1-16,18,20,22 f P1-24,26,28 1-1/4"C. (10) #10 & (1) #10 GND. -13 P1-13 P1-23 I) O P1-7 P1-13 P1-13 1 RTU-3 �P1-29 I I O L _ P1-31,33,35 3/4" C. 3 #8 & 1# 10 GND. P1-15 P1-3 P-21 ELECTRICAL COMPONENTS, EQUIPMENT & SYSTEMS SHALL BE DESIGNED AND CONSTRUCTED PER NFPA 70 - NATIONAL ELECTRIC CODE. MEANS OF EGRESS ILLUMINATION PER SEC. 1008. VERIFY DIRECTIONAL EXITSIGNS & EMERGENCY LIGHTING LOCATIONS PRIOR TO ELECTRICAL ROUGH -IN INSPECTION. —I P-35 I RTU-1 ® I O P1-1,3T L _ P-37,39,41 3/4'C. 3 #8 21 & 1# 10 GND. !! ! ! !!!!! ara a %m m . � a !! !! • O � Ir7 C M C I'7 ct 0 � O CN CN a�� a�a a�a a�a a�a a�a 9 EF-1 Pk 1 P-11 16 � P-20 Pt-15 ri� P-22 P-13 P- 3 O4 PNL P P1-5 P-24 O PNL P1 V 16 7 7 EFEF2 O O P-11 EF-1 IE--1 P-11 I RTU-4 61-29 P1-17 I F O P1-37,39,41 3/4' C. 3 #8 P1-27 & 1# 10 GND. P1-15 P1-17 €� Pi -1 P1-9 1 RTU- i -- I 'P-35 O L— P-38,40,42 3/4'C. 3 #8 & 1# 10 GND. P-15 P-8,10,12 I3/4' C. 3 #8 & 1# 10 GND. P1-17� I P1-1 P-34 P-34 P1-15 !!!! a�a!!ac0 NOON i I aaO mI ammmI —Iaia • Nis 00 00 DDN N I Pt-15NN- ® P -14 P-14 P-25 P1-1 18 P-14 5 P1-11 18 25 10 18 11 5 P-17 P-18 OW 11 NN T �CN O OCN OCV �N 8 1 1 a s a s a P-12 a a_ a s a s O tp-14 P-16 P-14 P-19 i 10' 10' 5' P-14 >� P-17 g P1-2,4,6,8,10,12�2i-6��:7P1-14 P1-12 1 1-1/4"C. (8) #10 91/2"C. (2) , 10 & (1) #10 GND. & (1) #10 . "'k 1 /2"C. (2) #10 & (1) #10 GND. ELECTRICAL POWER PLAN 111Mw 50 South Sixth Street / Suite 1100 Minneapolis, Minnesota 55402-1540 PHONE 612.465,7550 FAX 612.465.7551 WEB dunhameng.com mechanical + electrical consulting engineering CLIENT: UIIU T 1 11V\C R 1 IVC» SELF ESTEEM BRANDS, LLC 111 WEIR DRIVE WOODBURY, MINNESOTA 55125 PHONE: (651) 438-5123 PROJECT INFORMATION: O CO oo N 0 00 �z_ 2 � Lo 0 Np O Q ti LLJ J SEAL: 2018.08.30 DATE PROJECT NO.: 0419740-016 DRAWN BY: Az/CM CHECKED BY: RM/CM ISSUE: DATE: PERMIT SET 2018.08.30 REVISION: DATE: PROJECT LOCATION: GLENWOOD SPRINGS, CO *REFER TO E1.1 FOR NOTES AND DETAILS. 101YAJAV E1 )' I CONSULTANT: T\ s ,I. r�3�t/3ia �♦ P_1 \ P-2 TMV-1 \ P-2 TMV-1 WATER PIPING RISER DIAGRAM TEMPERED WAT WATER HOT PROVIDE AT LAVATORY / HAND SINK. NOTE: SET TEMPERED WATER TEMPERATURE TO 110 DEG F MAX. CHECK VALVE (lYP) RECIRC. PUMP (RCP-1) BALANCING VALVE/FLOW FITTING (2 GPM) DOMESTIC HOT WATER DOMESTIC COLD WATER THERMAL EXPANSION ABSORBER (IF FLOOR -MOUNTED PROVIDE 4" HOUSEKEEPING PAD) DRAIN VALVE THERMAL MIXING VALVE DETAIL NO SCALE (:5 I P-2 ( P-1 ` 1 P- 8 / / •r.� I 3�,a P-1 P 8 I r\ I > I P-4 P-6 I •4 I! F-44 v �4 �s I I _2 P-2 P-8 2 P-3 WASTE AND VENT RISER DIAGRAM NO SCALE -X 2':;A 57 SHUTOFF VALVE (TYPICAL) - BALANCING VALVE F CHECK VALVE (TYPICAL) IN-LINE RECIRCULATING PUMP THERMOMETER (TYPICAL) RECIRCULATING LINI TEMPERATURE/PRESSURE RELIEF VALVE ELECTRIC WATER HEATER PIPE OUTLET TO OS MOP SINK FLOOR 4" CONCRETE BASE 07 ELECTRIC WATER HEATER DETAIL SCALE: 1 /4" = 1'-0" F_. DOMESTIC WATER FLOOR PLAN SCALE: 1 /4" = 1'-O" PLUMBING REQUIREMENTS PER I.B.C., CHAPTER 29 AND IN ACCORDANCE WITH INTERNATIONAL PLUMBING CODE (IPC) PLUMBING ROUGH -IN INSPECTION REQUIRED PRIOR TO FRAMING INSPECTION. NOTE: PRIOR TO CONSTRUCTION/ BID THE CONTRACTOR SHALL VISIT THIS SITE AND FIELD VERIFY THE EXISTING LOCATIONS AND SIZES OF PLUMBING LINES AND FLOW DIRECTION. THE CONTRACTOR SHALL FIELD VERIFY ANY/ CONDITIONS WHICH MAY CONFLICT WITH THE DESIGN SHOWN ON THESE PLANS. NOTIFY ARCHITECT. LEGEND NEW SANITARY WASTE - - - - - - - NEW VENT - - COLD WATER PIPING (CW) - - HOT WATER PIPING (HW) 9 CONNECT EXISTING ELECT. WATER HEATER SCHEDULE EQUIP NO STORAGE CAPACITY GPH RECOVERY TEMP RISE ('F) ELEC. MANUF MODEL N0. REMARKS GAL KW WH-1 50 49 100 12 A.O. SMITH DVE-52-12 APPROVED EQUALS ARE ACCEPTED NOTE: 1. PLUMBING CONTRACTOR SHALL REFER TO ELECTRICAL PLANS AND COORDINATE WITH ELECTRICAL CONTRACTOR FOR PROPER UNIT ELECTRICAL REQUIREMENTS. 2. PROVIDE INSULATED COLD WATER INLET AND HOT WATER OUTLET HEAT TRAPS AT WATER HEATER. WASTE AND VENT FLOOR PLAN SCALE: 1 /47 = 1'-O" FIXTURE UNIT COUNT BASED ON THE 2015 ]PC. ITEM DESCRIPTION QTM TRAP SIZE D.F.0 TOTAL D.F.U. WS.F.0 TOTAL W.S.F.U. P-1 WATER CLOSET TANK TYPE 3 3 4.0 12.0 5.0 15.0 P- LAVATORY 3 1.50 2.0 6.0 2.0 6.0 P-3 MOP SINK 1 S' 11 2.0 2.0 3.0 3.0 P-4 FLOOR DRAIN SHOWER 2 3" 2.0 4.0 - - P-5 SHOWER FAUCET 2 - - - 4.0 8.0 P-6 1DRINKING FOUNTAIN 1 1.50" .5 .5 .5 .5 P-8 IFLOOR DRAIN EMGY 3 3" 0.0 0.0 - - TOTAL FIXTURE UNITS: D.F.U. 24.5 32.F.U. .5 W.S.F.U. 32.5 FU = 24.5 GPM (1-1/4" METER AND WATER SERVICE) D.F.U. SAN 24.5 FU = 4" PIPING HORIZONTAL ® 1/4" PER FOOT SLOPE DRAWING CODED NOTES 1 ROUTE NEW 1-1/4" CW PIPING AND TIE -INTO THE EXISTING LANDLORD PROVIDED 1-1/2" CW STUB -IN WITH SHUT-OFF VALVE FOR TENANT'S CONNECTION. VERIFY SIZE, ROUTING AND STUB -IN LOCATION IN FIELD. 2 CONNECT NEW SANITARY WASTE PIPING TO EXISTING LANDLORD PROVIDED 4" MINIMUM SANITARY WASTE PIPING. VERIFY ROUTING AND LOCATION ON SITE. O PROVIDE 3" VENT THROUGH ROOF, MAINTAIN MIN. 10'-0" FROM ANY OUTDOOR AIR INTAKES. O PROVIDE HOT WATER MIXING VALVE (TMV-1). SET MAX. OUTLET TEMP. AT 110' F. O ROUTE T&P RELIEF TO DRAIN IN MOP SINK. O TRAP PRIMER VALVE (TP-1) EXTEND AND CONNECT 1/2" TRAP PRIMER PIPING TO FLOOR DRAINS (P-8) WITH TRAP PRIMER CONNECTIONS. COORDINATE ROUTING. O CONTRACTOR TO INSTALL NEW EXPANSION TANK AMTROL MODEL ST-12, 4.4 GAL PER LOCAL CODE REQUIREMENTS. PLUMBING FIXTURE SCHEDULE FIXTURE TYPE MANUFACTURER: DIRECT INDIRECT VENT CW HW REMARKS NO MODEL WASTE WASTE P-1 WATER CLOSET AMERICAN STANDARD: CADET RIGHT 2" 1/2" - ADA, 1.6 GPF, PRESSURE ASSISTED FLUSH WITH 5321.110 HEIGHT TOILET 2467.016 EVERCLEAN SEAT P-2 LAVATORY AMERICAN STANDARD: LUCERNE 0355.01 7' - 1 1 2" / 1 2" / 1 2 / ADA PROVIDE AMERICAN STANDARD METERING FAUCET:1340.225 W/ METAL DRAIN & BRASS P-TRAP PROVIDE CHICA 0 FAUCET: 897-RCF, INTEGRAL VACUUM BREAKER - VERIFY P-3 MOP SINK SWANSTONE: MS-2424 BASIN 2" - 1 1 2" / 34" / 3 4" / ACCESSORIES W/ OWNER P-4 SHOWER FLOOR DRAIN ZURN: Z415 (ADJUSTABLE) 3" - 1 1/2" - - 6'0 TYPE 'N' NICKEL BRONZE TOP P-5 SINGLE SHOWER DELTA: T13H152-05 / R10000-UNWS - - - 1/2" 1/2" ADA, AND SHOWER W/ OPTIONAL 36" SLIDE BAR - 1.5 GPM W/ INTEGRAL W/ ROUGH -IN THERMOSTATIC MIXING VALVE AND BACKFLOW PREVENTER. P-6 CLEANOUT ZURN: ZN-1400 (ADJUSTABLE) 4' - - - - NICKEL BRONZE TOP P-7 BI-LEVEL FILTERED ELKAY MODEL LZSTL8WSSK W/ 2" - 1 1/2" 1/2" - FURNISHED AND INSTALLED BY PLUMBING CONTRACTOR PER ADA AND LOCAL CODE DRINKING FOUNTAIN / ACCESSORY APRON LKAPREZL - ADA REQUIREMENTS. ACCESSORY APRON TO BE INSTALLED ON "HIGH"DRINKING FOUNTAIN. BOTTLE FILLING COMPLIANT DRINKING FOUNTAIN APPROVED EQUALS ACCEPTED. STATION P-8 FLOOR DRAIN ZURN: Z415 (ADJUSTABLE) 3" - 1 1/2" - - 6'0 TYPE 'N' NICKEL BRONZE TOP W/ TRAP PRIMER CONNECTION TMV-1 THERMOSTATIC WATTS: LFMMV THERMAL MIXING VALVE. MAX OUTLET TEMP. 110 DEG F. IN ACCORDANCE WITH MIXING VALVE - - - 1/2 1/2 ANSI/ASSE 1017, 1069 & 1070 LISTINGS TP-1 TRAP PRIMER PPP: P1-500 W/ADAPTER _ _ _ 1/2" - INTEGRAL BFP AND VACUUM BREAKER MOUNT ABOVE CEILING H.W. RECIRCULATION SYSTEM - BELL & GOSSET MODEL NBF-25, RCP-1 HOT WATER BELL & GOSSET MODEL NBF-25 - _ _ _ 3/4" SPEED 2, 125 WATTS, 1.10 FLA., 115V.,1 PH., RATED @ 2 GPM, RECIRC.. PUMP 12 FT OF HEAD ; BRONZE IN -LINE. PROVIDE WITH AQUASTAT CONTROL WCO WALL CLEAN OUT ZURN MODEL #ZB-1443 _ _ _ - W/ SQUARE POLISHED BRONZE ACCESS COVER AND FRAME. NOTE: ALL FIXTURES MAY BE SUBSTITUTED WITH APPROVED EQUAL. CONTACT OWNER FOR APPROVAL DUNHAM DUNHAM 50 South Sixth Street / Suite 1100 Minneapolis, Minnesota 55402-1540 PHONE 612.465.7550 FAX 612.465.7551 WEB dunhameng.com mechanical + electrical consulting engineering CLIENT: LUM T 1 IIV\C 1�1 1 IVC» SELF ESTEEM BRANDS, LLC 111 WEIR DRIVE WOODBURY, MINNESOTA 55125 PHONE: (651) 438-5123 1 PROJECT INFORMATION: I SEAL C:> Cfl 00 CV 0 �(D _0 n _ U) Lo r-) c\1 0 00 W -J �pOQ L (op M Sr n : Q 45OT6 ? : ,. om.: zaie.ae.aa iz:sz:aaasna• 2018.08.30 DATE PROJECT NO.: 0419740-016 DRAWN BY: 6N CHECKED BY: es ISSUE: DATE: PERMIT SET 2018.08.30 IREVISION: DATE: I x PROJECT LOCPTION: GLENWOOD SPRINGS. CO SHEET CONSULTANT: (7'� MECHANICAL PLAN M1 SCALE: 3/16" = 1'-0" :HANICAL APPLIANCES, EQUIPMENT & SYSTEMS SHALL BE CONSTRUCTED, PALLED & MAINTAINED IN ACCORDANCE WITH INTERNATIONAL MECHANICAL )E (IMC) AND INTERNATIONAL FUEL GAS CODE (IFGC) CHANICAL ROUGH -IN INSPECTION REQUIRED PRIOR TO FRAMING INSPECTION. SEE SCHEDULES ON SHEET M2 FOR ADDITIONAL CONTRACTOR RESPONSIBILITIES. NOTE: ALL EXPOSED SUPPLY AIR DUCTWORK MUST BE SPIRAL. ALL EXPOSED SPIRAL SHALL BE INSTALLED AS HIGH AS POSSIBLE. COORDINATE ROUTING IN FIELD WITH OTHER TRADES PRIOR TO INSTALLATION. CONTACT ARCH. IF THERE ARE ANY FIELD DISCREPANCIES AND CONFLICTS. ,?" zois z.MC DRAWING CODED NOTES I < EXISTING LANDLORD PROVIDED GAS HEAT ROOFTOP UNIT TO BE REUSED — SEE SCHEDULE FOR AIR BALANCE AND REFURBISHING REQUIREMENTS. VERIFY EXISTING R.A. SMOKE DETECTOR, PROVIDE NEW IF REQUIRED. VERIFY EXACT LOCATION ON SITE. O2 RELOCATE EXISTING THERMOSTAT TO LOCATION SHOWN — MOUNTED AT 4'-0" A.F.F. CONFIRM OPERATION OF EXISTING THERMOSTAT PRIOR TO REUSE. PROVIDE NEW AS REQUIRED. O ROUTE FULL SIZE SUPPLY AIR DUCT DROP DOWN FROM EXISTING SUPPLY AIR ROOF CURB OPENING AND TRANSITION INTO DUCTWORK AS SHOWN ON PLAN. VERIFY ROUTING, SIZE AND LOCATION ON SITE. BOTTOM OF SUPPLY AIR AIR DUCT DROP SHALL TERMINATE AS HIGH AS POSSIBLE. 4O ROUTE FULL SIZE RETURN AIR DUCT DROP FROM EXISTING RETURN AIR ROOF CURB OPENING AND PROVIDE 90' ELBOW AND TERMINATE AS HIGH AS POSSIBLE. COVER OPEN END OF RETURN DUCT WITH 1/2" MESH HARDWARE CLOTH IN REMOVABLE METAL FRAME. BOTTOM OF RETURN AIR DUCT DROP SHALL TERMINATE AS HIGH AS POSSIBLE. OROUTE FULL SIZE RETURN AIR AIR DUCT DROP DOWN FROM EXISTING RETURN AIR ROOF CURB OPENING AND O9 MOUNT RETURN AIR TRANSFER GRILLE ON WALL AS HIGH AS POSSIBLE. ROUTE RETURN AIR TRANSFER DUCT FROM WALL MOUNTED GRILLE DN TO 24"x12" CEILING MOUNTED GRILLE. TRANSITION AS REQUIRED. COORDINATE LOCATION OF GRILLE IN FIELD WITH OTHER TRADES PRIOR TO INSTALLATION. TRANSITION INTO DUCTWORK AS SHOWN ON PLAN. VERIFY ROUTING, SIZE AND LOCATION ON SITE. BOTTOM OF RETURN AIR DUCT DROP SHALL TERMINATE AS HIGH AS POSSIBLE. O6 FURNISH AND INSTALL THREE NEW TOILET EXHAUST -FANS EF1. CONNECT WITH 8" RIGID DUCT W/ BACKDRAFT DAMPERS. 7O FURNISH AND INSTALL NEW UTILITY ROOM EXHAUST FAN EF2. SUPPORT FROM STRUCTURE ABOVE. CONNECT WITH 8" RIGID DUCT W/ BACKDRAFT DAMPER. gOROUTE 12" DIA E.A. DUCT UP THRU ROOF AND TERMINATE IN A GOOSENECK W/ BIRD SCREEN 24" ABOVE ROOF. LOCATE A MINIMUM OF 10'—O" FROM O.A. INTAKES. VERIFY ROUTING AND LOCATION ON SITE. <10> FLEX. DUCT 5'-0" MAX. LENGTH. TYPICAL FOR ALL UNLESS NOTED OTHERWISE. 11 VOLUME DAMPER AND SPIN —IN. TYPICAL FOR ALL. 1Q MOUNT RETURN AIR GRILLE ON WALL AS HIGH AS POSSIBLE. TRANSITION DUCTWORK AS REQUIRED. COORDINATE LOCATION OF GRILLE IN FIELD WITH OTHER TRADES PRIOR TO INSTALLATION. 1� ROUTE 14"X12" RETURN AIR DUCT DN WITH VOLUME DAMPER TO 24"x24" RETURN AIR GRILLE. TRANSITION AS REQUIRED. 14 TENANT CONTRACTOR SHALL COORDINATE INSTALLATION OF DUCT DROP TO DIFFUSER LOCATED IN LAY —IN CEILING IN A MANNER TO LIMIT FLEX DUCT TO A MAXIMUM OF 1'-0". FLEX DUCT SHALL NOT BE VISIBLE FROM OPEN AREAS WITHIN TENANT SPACE. DIFFUSER, GRILLE & REGISTER SCHEDULE EQUIP. SERVICE MOUNTING TYPE DESCRIPTION ACCESSORIES FINISH MANUF. MODEL TAG NO. A SUPPLY LAY —IN 24" X 24" OBD SEE TITUS TMS NOTE B SUPPLY DUCT MTD. 12" X 6" OBD SEE TITUS 30ORL NOTE C SUPPLY SURFACE 12" X 12" OBD SEE TITUS TMS NOTE D SUPPLY SURFACE 8" X 8" OBD SEE TITUS 30ORL NOTE E RETURN LAY —IN 24' X 24" — — — SEE TITUS PAR NOTE F RETURN SURFACE 24" X 14" — — — SEE TITUS 350RL NOTE G TRANSFER LAY —IN 24" X 12" --- SEE TITUS PAR NOTE H TRANSFER SURFACE 12" X 12" — — — SEE TITUS 350RL NOTE I TRANSFER SURFACE 8" X 8" — — — SEE TITUS 350RL NOTE J TRANSFER SURFACE 24" X 12" — — — SEE NOTE TITUS 350RL K SUPPLY DUCT MTD. 18" X 8" OBD SEE TITUS 30ORL NOTE NOTE: ALL GRILLES, REGISTERS & DIFFUSERS MUST BE PAINTED TO MATCH CEILING TILE COLOR. VERIFY EXACT COLOR WITH ARCHITECT. EXHAUST FAN — Fv **4sr 'k TAG QTY MANUFACTURER MODEL NO. TYPE CFM S.P. WATTS VOLTAGE ACCESSORIES NOTES EF-1 3 GREENHECK SP—B200 CEILING 150 .25 128 SEE ELEC BACKDRAFT DAMPER 1 EF-2 1 GREENHECK SP—E1200 SUSPENDED 150 .25 128 SEE ELEC BACKDRAFT DAMPER 2 NOTE: 1. TOILET 2. UTILITY EXHAUST FAN SHALL BE EXHAUST FAN SHALL BE INTERLOCKED WITH TOILET ROOM LIGHT INTERLOCKED WITH LIGHT SWITCH. SWITCH. EXISTING ROOFTOP UNIT SCHEDULE (GAS HEAT/ELEC. COOL) ENTERING IITONSR GROSS CASECITY CAPACITY ELECTRICAL UNIT WEIGHT MARK MODEL DISCHARGE .CFM AIRTSIDE CFM EER ACCESSORIES ( LBS) TOTACOOLING NSIBLLEH INPUT OUTPUT VOLT/PH/HZ RTU-1 YORK VERTICAL 4.0 EX. 1600 330 79.8F DB 64.OF WB EXISTING EXISTING EXIST. EXIST. EXIST. EXISTING EXISTING EXISTING D7CGO48 ® 95F AMBIENT RTU-2 YORK VERTICAL 4.0 EX. 1600 330 79.8E DB 64.0E WB EXISTING EXISTING EXIST. EXIST. EXIST. EXISTING EXISTING EXISTING D7CG048 ® 95F AMBIENT RTU-3 YORK VERTICAL 4.0 EX. 1600 330 79.8F DB 64.OF WB EXISTING EXISTING EXIST. EXIST. EXIST. EXISTING EXISTING EXISTING D7CGO48 ® 95F AMBIENT RTU-4 AMER.STD. VERTICAL 1 5.0 EX. 2000 410 79.8F DB 64.OF WB EXISTING EXISTING EXIST. EXIST. EXIST. EXISTING EXISTING EXISTING YSC060 ® 95F AMBIENT NOTE: 1. THE MECHANICAL CONTRACTOR SHALL PERFORM SERVICE AND REPAIR OF THE EXISTING ROOF TOP UNIT AND ITS ACCESSORIES AS FOLLOWS, BUT ARE NOT LIMITED TO: CLEAN ALL COILS, REPLACE THE FILTERS AND BELTS, INSPECT, REPAIR OR REPLACE DRIVES, FAN BEARINGS, MOTORS, CONTROL COMPONENTS, VALVES AND ANY OTHER ITEM NECESSARY FOR A COMPLETE AND PROPER OPERATING SYSTEM. THIS CONTRACTOR SHALL ALSO VISIT THE SITE PRIOR TO BIDDING AND VERIFY ALL EXISTING SITE CONDITIONS. 2. ALL WORK, EQUIPMENT, AND ACCESSORIES TO BRING EXISTING SYSTEM TO GOOD WORKING CONDITION SHALL BE COVERED UNDER CONTRACTOR'S ORIGINAL BID AND AT NO ADDITIONAL EXPENSE. CONTRACTOR SHALL VERIFY ALL ON SITE CONDITIONS PRIOR TO BID. 10 DUNHAM DUNHAM 50 South Sixth Street / Suite 1100 Minneapolis, Minnesota 55402-1540 PHONE 612.465.7550 FAX 612.465.7551 WEB dunhameng.com mechanical + electrical consulting engineering CLIENT: 111V T 1 11V\C rl 1 IVC» SELF ESTEEM BRANDS, LLC 111 WEIR DRIVE WOODBURY, MINNESOTA 55125 PHONE: (651) 438-5123 I PROJECT INFORMATION: SEAL: O 00 N 0 00 3z _0 2 U) Lo 0 N O O O ti W 0 U: p ,a 45076 �Y=�• 60,CN-Gre rql MSteinmetz. 0.ldenTmt ACES UnalNfaled IndNdual, C=US dale: 2018.08 t2:42250500' 2018.08.30 DATE PROJECT NO.: 0419740.016 DRAWN BY: BR CHECKED BY: Gs ISSUE: DATE: PERMIT SET 2018.08.30 DATE: PROJECT LOCATION: GLENWOOD SPRINGS, CO SHEET NUMBER I TITLE: ra coNsuLTNT. SEAL DUCTWORK WATER —TIGHT — GOOSENECK — COUNTER FLASHING BY MECHANICAL CONT.--\ CURB FURNISHED BY MECHANICAL CONT. TO THE GENERAL CONTRACTOR FOR INSTALLATION. —.__ EXHAUST DUCT W/ EXTERNAL INSULATION GOOSENECK VENT THRU ROOF NO SCALE BIRDSCREEN NOTE: MATERIALS AND INSTALLATION SHALL BE PER SMACNA STANDARDS TYPICAL IF 2 SIDEWALL DIFFUSERS ARE USED. SEE PLANS SECURE CABLE TO STRUCTURE PER MANUFACTURES REQUIREMENTS — REFER TO SMACNA FOR f CONNECTION TYPES. SEAL ALL AROUN WITH ELASTOMER GASKET CABLE LOCK. 24 GAUGE, ROUND SINGLE WALL SPIRAL SEAM DUCT. SEE DWG'S. FOR SIZES. SHEET METAL BOOT TO MATCH DUCT — 45' ANGLE SIDEWALL DIFFUSER. FXPOSM SPIRAL DUCT N.T.S. HVAC LEGEND SYMBOL DESCRIPTION ® SUPPLY AIR DIFFUSER DUCT MOUNTED SUPPLY AIR DIFFUSER aRETURN AIR GRILLE Q DUCT SMOKE DETECTOR Q THERMOSTAT DAMPER FLEXIBLE DUCT CONNECT TO EXISTING A-10" 0 DIFFUSER TYPE/NECK SIZE 450 CFM REQUIRED MECHANICAL NOTES 1. ALL EQUIPMENT, INSTALLATION AND MATERIALS SHALL COMPLY WITH ALL APPLICABLE LANDLORD CRITERIA. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING, PRIOR TO FINAL BID, ALL EXISTING STUB —INS, TAPS, ETC. FOR PLUMBING AND MECHANICAL SYSTEMS WITHIN TENANT SPACE. 3. NO FIBERGLASS DUCT BOARD ALLOWED. 4. BRANCH DUCT RUN OUTS TO DIFFUSERS SHALL BE SAME SIZE AS DIFFUSER NECK UNLESS OTHERWISE SPECIFIED. 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FINAL CONNECTIONS TO THE LANDLORD'S BASE SYSTEMS. COORDINATE ALL SYSTEMS IN THE FIELD. 6. VERIFY LOCATION OF ANY PENETRATION OF ROOF WITH LANDLORD. ALL ROOF PENETRATIONS, PATCHING AND FLASHING SHALL BE BY LANDLORD APPROVED ROOFING CONTRACTOR AT TENANT CONTRACTOR'S EXPENSE. 7. PVC PIPING IS PROHIBITED. 8. ALL FIRE PROTECTION AND SPRINKLER WORK SHALL BE PERFORMED BY LANDLORD —APPROVED FIRE PROTECTION CONTRACTOR AT THE TENANT'S EXPENSE. 9. CONTRACTOR SHALL SUBMIT AIR BALANCE REPORT INCLUDING ALL ASSOCIATED AIR TEMPERATURES AND PRESSURES AS APPLICABLE. SEND TWO COPIES TO OWNER FOR APPROVAL. 10. EXPOSED DUCTWORK SHALL BE STANDARD SPIRAL ROUND GALVANIZED SHEET METAL DUCTWORK 24 GAUGE UP TO 30", 22 GAUGE — 32" to 50". ALL EXPOSED SPIRAL DUCTWORK SHALL BE INSTALLED AS HIGH AS POSSIBLE. COORDINATE ROUTING IN FIELD WITH OTHER TRADES PRIOR TO INSTALLATION. CONTACT ARCH. IF THERE ARE ANY FIELD DISCREPANCIES AND CONFLICTS. SPACE LOAD CALCULATIONS DESIGN TEMPS SUMMER O.A.D.B. 95 DEG F O.A.W.B 60 DEG F I.A.D.B. 75 DEG F GAINS SOLAR LOAD 20586 BTUH ROOF LOAD 13380 BTUH GLASS LOAD 4583 BTUH WALL LOAD 3837 BTUH LIGHTS 15328 BTUH PEOPLE (SENS) 19390 BTUH PEOPLE (LAT) 42575 BTUH INFILTRATION (SENS) 2581 BTUH INFILTRATION (LAT) 1764 BTUH MISCELLANEOUS 13500 BTUH VENTILATION (SENS) 20441 BTUH VENTILATION (LAT) 14920 BTUH SUPPLY FAN LOAD 3208 BTUH SENS. LOAD 121243 BTUH TOTAL LOAD 126000 BTUH TOTAL CFM 6800 WINTER O.A.D.B. —3 DEG F I.A.D.B. 70 DEG F LOSS 23542 BTUH 20732 BTUH 5245 BTUH 11872 _BTUH 89898 BTUH —3781 BTUH TOTAL 147507 BTUH VENT. 1400 CFM - OUTSIDE AIR CALCULATION O.A. CALCULATION BASED ON THE 2015 INTERNATIONAL MECHANICAL CODE GUEST/MEMBER LOBBY: LOBBIES OCC.= 10p/1000 sqft= 4 P SQUARE FOOTAGE: 425 SF VENTILATION CALCULATED AT 20 (5 cfm/p) + 25 (.06 cfm/sgft) VENTILATION: 45 CFM CARDIOZSTRENGTH/FUNCTIONAL/FREE WEIGHTS/MULTI—PURPOSE: HEALTH CLUB OCC.= 10p/1000 sqft= 38 P NET SQUARE FOOTAGE:3760 SF VENTILATION CALCULATED AT 760 (20 cfm/p) + 225 (.06 cfm/sqft) VENTILATION: 985 CFM MANAGERS OFFICE: OFFICE SPACES OCC.= 5p/1000 sqft= 1 P SQUARE FOOTAGE: 115 SF VENTILATION CALCULATED AT 5 (5 cfm/p) + 7 (.06 cfm/sgft) VENTILATION: 12 CFM TRAINERS OFFICE: OFFICE SPACES OCC.= 5p/1000 sqft= 1 P SQUARE FOOTAGE: 75 SF VENTILATION CALCULATED AT 5 (5 cfm/p) + 5 (.06 cfm/sqft) VENTILATION: 10 CFM CHANGING ROOMS: OFFICE SPACES OCC.= 5p/1000 sqft= 2 P SQUARE FOOTAGE: 120 SF VENTILATION CALCULATED AT 10 (5 cfm/p) + 7 (.06 cfm/sqft) VENTILATION: 17 CFM TANNING: OFFICE SPACES OCC.= tOp/1000 sqft= 1 P SQUARE FOOTAGE: 80 SF VENTILATION CALCULATED AT 5 (5 cfm/p) + 5 (.06 cfm/sgft) VENTILATION: 10 CFM UTILITY: STORAGE OCC.= N/A 0 P SQUARE FOOTAGE: 145 SF VENTILATION CALCULATED AT 17 (.12 cfm/sgft) VENTILATION: 17 CFM CORRIDOR: HALL OCC.= N/A 0 P SQUARE FOOTAGE: 315 SF VENTILATION CALCULATED AT 19 (.06 cfm/sqft) VENTILATION: 19 CFM TOTAL VENTILATION REQUIRED .80 VENTILATION EFFECTIVENESS TOTAL VENTILATION SUPPLIED 1115 CFM 1393 CFM 1400 CFM w8i 04 1 EMM DUNHAM 50 South Sixth Street / Suite 1100 Minneapolis, Minnesota 55402-1540 PHONE 612,465.7650 FAX 612.465.7551 WEB dunhameng.com mechanical + electrical consulting engineering CLIENT. A& � ■VI L1IV T 1 11MIC 1m1 1 IVC» SELF ESTEEM BRANDS, LLC 111 WEIR DRIVE WOODBURY, MINNESOTA 55125 PHONE: (651) 438-5123 PROJECT INFORMATION: ISEAL: 7— O CO 00 N 0 00 co L N p o0 ti W _J H Ni.1 sj.'•. S.'O¢ n i 45076 n O'05 D...2D1B0 W1242,110Y9 2018.08.30 DATE PROJECT NO.: 0419740.016 DRAWN BY: SR CHECKED BY: Gs ISSUE: DATE: PERMIT SET 2018.08.30 REVISION: DATE: PROJECT LOCATION. GLENWOOD SPRINGS, CO SHEET NUMBER / TI M2 MECH- SCHED. � DETA}tS