HomeMy WebLinkAboutOWTS Permit Card
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945-6614 ext. 8150
For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: 2225 Midland Ave Glenwood Springs_ Parcel No.: 218516400089_
Owner Name: Eliecer Miramontes Gonzalez Owner Phone: (970) 485-4367
Designed By: Boundaries Unlimited Designer Phone: (970) 945-5252
Number of Bedrooms: _6_ Minimum Tank Capacity: 2,000-gallon Minimum Absorption: 1,115 ft 2
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number _SEPT-8498_______________________________
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date _02/13/2024____________________ Expiration Date_02/13/2025_________________
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the report and design as
submitted by Boundaries Unlimited dated December 22, 2023. Changes to the design and permit
must be approved by Garfield County Public Health and the designer prior to construction.
The new OWTS will serve a new four-bedroom residence and a two-bedroom ADU. The system will
consist of a new, two-compartment 2,000-gallon septic tank set level with access to grade followed
by a 500-gallon single-chamber pump chamber set level with access to grade and a high-head pump
in the pump chamber. Effluent will be pumped to an automatic distributing valve set at the high
point of the system that will distribute effluent to 1,224 ft 2 of STA. The new STA will consist of two
gravelless chamber beds, each bed consisting of three rows of Quik4 chambers with 17 chambers
per trench (102 Quik4 chambers total). Distribution laterals are to be 1 ½ inch Schedule 40 PVC, with
3/16-inch orifices 4-feet on center and the laterals ending in flushing valves at the distal end of the
laterals. The orifices are to be facing upward, except for the first and last orifice (which shall face
downward for drainage purposes). Inspection ports are to be installed at each corner of each bed.
Maintain all setbacks and elevations as designed.
Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final
inspection of the installed system prior to backfill. NO OWTS COMPONENT SHALL BE BACKFILLED
WITHOUT PRIOR APPROVAL FROM GARFIELD COUNTY PUBLIC HEALTH AND THE DESIGNER.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction, and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection,
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as-built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
02/13/2024
Issued By: Garfield County Environmental Health
Department
Date