HomeMy WebLinkAboutOWTS Spec SheetItem #
tilt {o60.2cP
{060 Gallon Two Gompartment
lnflltrator@ Poly Tank
IT'Top
View
TANKTOP
HALF
CONTINUOUS
GASKET
6Ut'.
TANK
INTERIOR SEAM CLIP
(64)
ALIGNMENT
DOWEL (34)TANK BOTTOM
HALF
Mid-Height Seam
Section
24'AOCESSOPEN|]{G\Section
View
Tank lndtda llds
51.7'
I
1T'4',OUTLET
IT'
t
54.7
EXTERIOR
HEIGHTCompliont with CSA ond IAPMO Stondords
PVC risers ovoiloble
Secondory sofety screen ovoiloble with PVC riser
Moximum buriol depth is 48"
Minumum buriol depth is 6"
Tonk is not roted for vehiculor troffic looding
Exterior of monhole cover includes the following
worning: "DANGER DO NOT ENTER: POISON
GASES''
SEAM CLIP
(TYPTcAL)
+
LIFTING STRAP
(rYPrcAL)
End
View
ffir,nnf;g*'
ril.il totsYsElirc.
n
\
\o
o
<-o oc-
o\
\o
E E
f,,
I
Bulkhed
Digging Specs I n vert Dimensions Net
Copocity
Weight
12' Long x 7' Wide lnlet
47"
Outlet
44"
Length
127"
width
62.2"
Height
54.7"1094 gol 320 lbs
Water &
Wactewater
o Systems
o Prcducils
Ine. o SeMce
(719) 3955764 2flXECo Rd' 317
P.O. Bo(@5
Fu: (/lglgg+g|n B'HEVlsla' @81211
Webslb: www.valleyryrccastom
Emll : fionHeek@valleypremtortffiw PRtcAst,
Residential Biotube' Effluent Filters
Applications
Our patented* 4-in. (100-mm) Biotube Effluent Filters, Biotube Jr., Biotube
Insert Filters, and Biotube Base Inlet Filters are ideal for residential septic
tanks and have a lifetime warranty. They prevent large solids from leaving
the tank, dramatically improving wastewater qualiry and extending the life
of residential drainfields.
4-in. (100-mm) Biotube Efluenr Fiber
'.,'
1
4-in. (100-mm) Biotube Jr.
(4-in. Biotube cartridge auail-
able separatef as Insert Fiher)
:
8-in. (200-mm)
Base Inlet Fiber
4-in. (100-mm)
Insert Fiber
$
i
it
Orenco's superior effluentfhers resist clogging better than all other brands. Our stan'
dard, full-sized 4-in. (100-mm) Biotube EfiIuent Filter prouides maximum long-term
protection in a complete package, with housing. Our 4-in' (100-mm) Biotube Jr., at
half the size of our standard model, has more f ltering capacit! than the full-sized f hers
sold by other manufacturers. For tanhs with existing outlet tees, the Biotube Insert Fiber
is ideal. And for low-profle tanks, there's the Base Inlet Fiher.
* Covered by patent nunbers 5,492,635 and 4,439,323
To 0rder
Call your nearest Orenco Systems@, Inc. distributor. For nearest distribu-
tor, call Orenco at 800-348-9843 or go to www.orenco.com and click on
"Distributor Locator. "
APS-FT-1
Bev. 3.4 @ 1lfl0
0renco Systems@, lnc.
Standard Features & Benefits
. Has 5-10 times
more flow area
than other brands,
so lasts many
times longer
between clean-
ings, increasing
homeowner
satisfaction
. lnstalls in min-
utes inside new
or existing tanks;
extendible tee
handle for easy
removal
. Easyto clean by
simply hosing off
whenever the tank
needs pumping
. Removes about
two-thirds of sus-
pended solids, on
average, extending
drainfield life
. Corrosion-proof
construction, to
ensure long life
. Lifetime warranty
0ptional
Features &
Benefits
Biotube
Filtering
Process
. Alarm available, to
signal the need for
cleaning
. Flow modulating
discharge orifices
available to limit
flow rate leaving
tank, mitigat-
ing surges and
increasing
retention time
. Custom and
commercial sizes
available
Effluent from the
relatively clear zone
of the septic tank,
between the scum
and sludge layers,
horizontally enters
the Biotube Effluent
Filter. Effluent then
enters the annular
space between the
housing and the
Biotubes, utilizing
the Biotubes'entire
surface for filtering.
Particles larger than
the Biotube's mesh
are prevented from
leaving the tank.
+-_/
,
Changing tfn Wky tbt
Wo rld il s es \Yb s t€ ut fl N r d
*.
€
Orenco$ystems'"'
lncarparated
v$wnr!{rl€nco.coltt
Nomenclatures
4-in. Biotube Filter {standard)
FT o4 !_
0ptions:
Blank = no optionsM = llow modulation plate installedA = float bracket attached
Cartridge height: 28" and 36" are standard
Housing height:36" and 44" are standard
Filter diameter (inches)
W = fitsType 3034 outlet pipe
S = lits Schedule 40 outlet pipe
Blank = 1/B" filtrationP = 1/16" liltration
Biotube effluent filter series
8-in. Biotube Fifter (base intetmodel)
FTI os 22-148
0ptions:A = float bracket
FS = 2" outlet orilice
FSO = 2" outlet orilice and overflow plate.
Base inlet model
Cartridge height: 1 4" standard
Housing height: 22" standard
Filter diameter (nches)
Blank = 1/S" filtration
P = 1/16" liltration
. Also available with coupling and sleeve as a "kit": FI-0VERFLOWKIT
4-in. Biotub€ Jf. (lnctuoes cartridge and housing)
FT J Ilo+ re
no options
Biotube effluent filter series
Junior series
Biotube effluent filter series
lnsert
= llow modulation plate installed
= lloat bracket attached
-T_I Upttons:
Blank =
IV
A
Blank
P
Cartridge height (inches)
Filter diameter (inches)
W = fits Type 3034 outlet tee
S = fits Schedule 40 outlet tee
= 1/8" filtration
= 1/l6" filtration
4-in. Biotube Fiher lnsert (carrridge onV)
FTi 0418-
For customized options (e,9,, NC
indicates North Carolina regions)
W = fits Type 3034 outlet tee
S = lits Schedule 40 outlet tee
Cartridge height (inches)
Filter diameter (inches)
= 1/S" filtration
= 1/16" filtration
Blank
P
Biotube effluent filter series
Distributed By:
4-in. Biotube
Effluent Fifter
Extendible PVC handle
Stainless steel set screws
Top seal plate
Air vents
Biotube@ filter cartridge
Solid base
Filter housing
4-in. Biotube Jr
Tank wall
Riser
wall
Nomenclatures
4-in. Biotube Fifter (standard)
FT!TO4TT.TTE
Cartridge helght:28" and 36" are standard
Housing height: 36" and 44" are standard
Filter diameter (inches)
W = fits
S = fits
Type 3034 outlet pipe
Schedule 40 outlet pipe
/8" filtration
/1 6" filtration
Biotube effluent filter series
8-in. Biotube Fifter (base intet modet)
FT 08 22- 14 B
Blank
P
--T--
| Options:
Blank = no optionsM = flow modulation plate installedA = float bracket attached
0ptions:A = float bracket
FS = 2" outlet orifice
FSO = 2" outlet orifice and overflow plate-
Base inlet model
Cartridge height: 14" standard
Housing height: 22" standard
Filter diameter (nches)
Biotube effluent filter series
Blank = 1/8" liltrationP = 1/16" filtration
Blank = 1/S" liltrationP = 1/16" filtration
Blank = 1/S" liltrationP = 1/16" filtration
lnsert
---T--
I Options:
Blank = no optionsM = flow modulation plate installedA = float bracket attached
Cartridge height (inches)
Filter diameter (inches)
- Also available with coupling and sleeve as a "kit": FI-OVERFLoWKIT
4-in. Biotub0 Jf. (includes carridge and housing)
FT J IIo+ re E
W = fits Type 3034 outlet tee
S = fits Schedule 40 outlet tee
Junior series
Biotube effluent filter series
4-in. Biotube FiJter lnseft (carrridse only)
FT i !04 18 -I ---T--
I For customized options (e.9., NC
indicates North Carolina regions)
W = fitsType 3034 outlet tee
S = lits Schedule 40 outlet tee
Cartridge height (inches)
Filter diameter (inches)
Biotube effluent filter series
Distributed By:
4-in. Biotube
Effluent Fiher
Extendible PVC handle
Stainless steel set screws
Top seal plate
Air vents
Biotube@ filter cartridge
Solid base
Filter housing
4-in. Biotube Jr,
Tank wall
Riser
wall
Double Walled PVG Riser & Lid Options
Poly Lid
(Static load tested to 5000lbs). Skid resistance surhoe. Available in green. Highest level of UV Probction induded. lncludes a foam gasket fur airtight and
waterti ght appl ications. Includes square drive scr€rrtfs b disounage
unauthorized enfy. lnsulation panels achieve R-10 insulation nating
2'of lnsulation
Standard
Orenco @ DuraFiberm Access Lids (FLD)
Not rccommended fur vehicular haffic
24 and 30'Diamebrso Solid, resin-infused fiberglass constustion. 20,00G1b breaking shength. Standard green or brcwn colorso Available with or without urcthane lid gasket
o Available with carbon filhation. 4 stainless steel flathead socket cap scr€ws & hex
key wrencfto lnsulated lids available - 2'or4'
Double Walled PVC Riser
. Available in 24' and 30" Diamebr. Cut to lengthr Sold in +/- 2'incremenb. Must be cut between ribs
ffi PRtCAS|flrne. oseMce
(719) 3956704 2sxbco Rd317
P.O. Bo(95
Farc (/l9)gffignn BIsE\nsb' @81z.1
Webclb: www.vallelprecastom
Emll : fiondeok@5/deyryrccastom
Water &
Wasteffir
. Systems
o Prcducts
POLYLOK DISTRIBUTION BOX,
RISERS, AND LID
uD.BOX6&UD€OX8
-22.4511
+D.BOX SEAL
(arERYDSXO(IESWrfl
48EAA'
16"SIDE CUT OUT
TO ACCEPT
POLYLOK SEAL
NO.3001 TEAR OUT FOR
4'SDR-35 0R
SCHD4O
NOTTO SCATE
UD.BOX 6'RISER
ROTO-FLOW4'
I
6t'
i
UD.BOX {2'RISER NOT TO SCATE
POLYLOCK EQUATZER
I|.NOTCH'WE'R
1
$IAPE 18
sEFtEVErl{G
RIBS PROVIDE FRICTK)N
F]TFfiAU-f PIPEID
d du
20'covER FoR RISER & DAOX irorT0sc/lt-E
GASKETED SEAL ON
LID & RISER
WSr&
waerewtrr grel3eo5z64 ffigtstz
t System
lrnc.:3HH[ffi,trffiffi81211ffi PRTCASI
Dtu: O7t24t2019
Shoet 1 of 1Ch€*dby: DFH
,'ttr-
INFILTRATOR"
systems inc
INFILTRATOR SYSTEMS INC.
4 Business Park Rd. Old Saybrook, CT 06475
(800) 221-4436
QUICK4 PLUS STANDARD
LOW PROFILE CHAMBER
PRODUCT SPECIFICATION
DffibE EMB
S€lg: ror ro sarr
INFILTRATOR SYSTEMS INC.
QUICK4 PLUS STANDARD
LOW PROFILE CHAMBER
PRODUCT SPECIFICATION
(NOT TO SCALE)
TOP VIEW QUICK4 PLUS ALL.IN.ONE END CAP
1 0.4'' EFFECTIVE LENGTH-
INSPECTION PORT
8"
3.3'' INVERT l-- 1s" -t
1 3.3'' EFFECTIVE LENGTH-
QUICK4 PLUS END CAP
4.5'' EFFECTIVE LENGTH-
8"
53"
3.3'' INVERT l-- 19" --l 6"
SIDE VIEW END VIEW
48"
(EFFECTTVE LENGTH)
8"
34"
-ALL VIEWS = INSTALLED LENGTHS