HomeMy WebLinkAboutOWTS Installation Observations 06.15.2023CBO Inc.
129 Cains Lane
Carbondale, CO 81623
970.309.5259
carla.ostberg@gmail.com
June 15, 2023 Project No. C1574
Barbara Dills
Barbara.dills@gmail.com
Onsite Wastewater Treatment System (OWTS) Installation Observations
2078 CR 102
Garfield County, Colorado
OWTS Permit SEPT-6898
Barbara,
CBO Inc. observed the installation of the onsite wastewater treatment system (OWTS) on August 13 &
26, 2021 and June 12, 2023 for the subject property. Savage Excavation installed the system.
The OWTS design is based on 1-bedroom with 3 future bedrooms proposed for a total of 4 bedrooms.
An average daily wastewater flow of 600 GPD was used.
The 4-inch diameter SDR-35 sewer lines exiting the residence and Barn/Office have double-sweep clean
outs and a minimum 2% grade to the septic tank. Plumbing in the Barn/Office are an auxiliary use to the
main house. The sewer line has a clean out at least every 100-feet.
The system installation included a 1500-gallon, two-compartment Valley Precast concrete septic tank
with an effluent filter on the outlet tee. This filter must be cleaned annually, or as needed. Risers must
bring the manhole lids to grade for access.
Effluent will gravity flow to a distribution box, and then to four GeoMat™ trenches. The distribution box
was accessible from grade with flow equalizers installed on each outlet pipe in the distribution box to
assure equal flow to each trench.
Each 36-inches wide trench has a minimum of 6-inches of sand filter material. A gradation of the sand
media is enclosed.
GeoMat™ sheets were placed on top of the sand filter material the entire length of the trench. A 4-inch
diameter perforated pipe was placed down the center of the GeoMat™, under the top layer of fabric.
The STA consists of 4 trenches, each with 60 linear feet of 39-inch wide GeoMat™ for a total of 240
linear feet and 720 square feet.
There was at least 4-feet of undisturbed soil between each trench. Inspection ports were installed at the
beginning and end of each trench. The front inspection port was placed to the side of the GeoMat™ and
the end inspection port was tied onto the end of the lateral. Ports may be cut to grade and placed in
sprinkler boxes for access.
The OWTS was generally installed according to specifications. This observation is not a guarantee of
workmanship and/or parts and materials. CBO Inc. should be notified if changes are made to the OWTS
in the future. Any additional OWTS construction must be according to the county regulations.
LIMITS: Observations are limited to components that are visible at the time of the inspection. The installer must
have documented and demonstrated knowledge of the requirements and regulations of the county in
which they are working. The quality of the installation is dependent on the expertise of the installer, soil
type, and weather conditions.
Please call with questions.
Sincerely,
CBO Inc.
Carla Ostberg, MPH, REHS
Septic tank excavation and bedding Trench excavation
Distribution box
Perf piping down center of GeoMat sheet
Addimb
Garfield Cottnfy]
Public Health
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945-6614 ext. 8150
Permit Number SEPT-6898
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date 06/21/2021 __ Expiration Date 06/21/2022
For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: TBD CR 102, Carbondale, CO 81623 Parcel No.: 239128200112
Owner Name: Barbara P. Dills Owner Phone: (970) 963-5782
Designed By: CBO Septic Consulting, Inc. Designer Phone: (970) 309-5259
Number of Bedrooms: 4 Minimum Tank Capacity: 1,250-gallon Minimum Absorption: 700 ft'
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the report and design as
submitted by CBO Septic Consulting, Inc. dated April 4, 2021. Changes to the design and permit must
be approved by Garfield County Public Health and the designer prior to construction.
The new OWTS will serve a new one -bedroom residence, with a potential three -bedroom expansion.
The system will consist of a new, two -compartment 1,500-gallon septic tank set level with access to
grade with an effluent filter in the outlet tee of the tank. Effluent will gravity flow to a distribution
box set level with access to grade to distribute effluent to 780 ftz of STA. The new STA will consist of
four GeoMat trenches that will be 3 feet wide by 60 feet long. Inspection ports are to be installed at
each end of each trench. Maintain all setbacks and elevations as designed.
Contact the designer and Garfield County Public Health at least 48 hours prior to requesting fir, all
inspection of the installed system prior to backfill.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction, and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection,
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as -built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
J
06/21/2021
Issued By: Garfield County Environmental ' ealth Date
Department
832‐R‐13‐002