Compliance Certificate
Project doka
Energy Code:
Location:
Construction Type:
Project Type:
Conditioned Floor Area
Glazing Area
Climate Zone:
Permit Date:
Permit Number:
2018 tECC
Rifle, Colorado
Single-family
New Construction
2,990 rt2
2oo/o
s (6881 HDD)
Compliance: 8.o7o B€tter Than Code Maximum UA: 4L4 Your UA: 381
The % Better or Worse Than Code lndex reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home'
Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade
assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements'
Envelooe Assemblies
Construction Site:
0 county rd 325
Rifle, CO 81650
Ceiling: Raised or Energy Truss
Walls North main Level: Wood Frame, 16" o.c.
Door 2: Glass Door (over 50% glazing)
Window 2: Vinyl Frame
Walls South Main Level: Wood Frame, 16" o.c.
Door 1: Glass Door (over 50% glazing)
Window L: Vinyl Frame
Walls West Main Level: Wood Frame, 16" o.c.
Window 4: Vinyl Frame
Walls East Main Level: Wood Frame, 16" o.c.
Door 3: Solid Door (under 50% glazing)
Window 3: Vinyl Frame
Walls North Upper Level: Wood Frame, 16" o.c
Owner/Agent:
Evan Doka
11740 WTANFORAN PL
MORRISON, CO
720-492-5928
ScHULZEVAN 1@G MAIL.COM
Desig ner/Contractor:
James Martinez
Martinez Construction
580 NORTH MEADOW DRIVE
Rifle, CO 81650
970 319 0919
jmartinez@martinezwestern.com
\
N
\
{q
$.\
*\t
.\
\a
L,334
3r.9
'1,23
36
306
155
t22
1,057
158
425
23
93
348
0.020
0.059
0.270
0.270
0.059
0.270
0.270
0.059
0.270
0.059
0.270
0.270
0.059
0.026
0.060
0.300
0.300
0.060
0.300
0.300
0.060
0.300
0.060
0.300
0.300
0.060
35
10
37
11
2
47
37
54
47
L9
7
2B
2l
49.0
20.0
20.0
20.0
20.0
0.0
0.0
0.0
0.0
0.0
0.0
2
27
9
33
10
42
33
53
43
18
6
25
2t
Compliance: Passes using UA trade-off
Cavity
R-Value
Cont. Prop. Req. Prop.
R-Value U-Factor U-Factor UA
Gross Area
Assembly
Perimeter
ReqorUA
20.o
Project Title: doka
Data filename:
Report date: lll01'l23
Page 1 of10
Cavity
R-Value
Cont.
R-Value
Prop, Req,
U-Factor U-Factor
Req'
UA
Gross Area
orAssembly
Perimeter
Prop.
UA
West Upper Level Walls: Wood Frame, 16" o.c. 335 20.0 0.0 0.059 0'060 20 20
South Upper LEvel Walls: Wood Frame, 16" o.c. 318 2O'0 0'0 0.059 0'060 19 1"9
East Upper Level Wall: Wood Frame, 16" o.c. 337 20.0 0'0 0.059 0'060 20 20
Compliance Statement: The proposed building design described.here.is consistent with the building plans, specifications,.and other
calculations submitted witn tfie permit applica-tion. fhe proposed building has been designed to meet the 2018 IECC requirements in
REscheckVersion : REScheck-deb and to'comply with the mandatory requirements listed in the REScheck lnspection Checklist.
Name - Title Signature Date
Project Title: doka
Data filename:
Report date: lLl11-l23
Page 2 of10
REScheck Software Version REScheck-Web
lnspection Checkl t
Energy Code: 2OLB IECC
Requirements: 0.0% were addressed directly in the REScheck software
Text in the ,'Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is lieing claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Additional Comments/Assumptions I
s
EComplies
nDoes Not
INot Observable
[lNot Applicable
103.L,
r.03.2
lPR1ll3
Construction drawings and
documentation demonstrate
energy code compliance for the
building envelope. Thermal
envelope represented on
construction documents.
nDoes Not
nNot Observable
lNot Applicable
pliesr.03.1,
103.2,
403.7
lPR3l1g
Construction drawings and
documentation demonstrate
energy code compliance for
lighting and mechanical systems.
Systems serving multiPle
dwelling units must demonstrate
compliance with the IECC
Commercia I Provisions.
sized per ACCA Manual S based
on loads calculated perACCA
Manual J or other methods
approved by the code official.
Heating:
Btu/hr_
Cooling:
Btu/hr
Heating:
Btu/hr_
Cooling:
Btu/hr_
itr
in
in
I
Heating and cooling equiPment is plies
Does Not
Not Observable
Not Applicable
LoW I (Tier 3)(Tier 1)H Medium (Tier 2)1
Project Title: doka
Data filename:
Report date: LLlOLl23
Page 3 ofL0
A protective covering is installed to
protect exposed exterior insulation
and extends a minimum of 6 in. below
grade.
iEComplies
Snow- and ice-melting system controls
installed.
plies
Not
!Not Applicable
Not Observable
Additional Comments/Assumptions:
Low I (Tier 3)(Tier 2)Medium1(Tier L)H
Project Title: doka
Data filename:
Report date: l].'l0Ll23
Page 4 of10
the Envelope AssembliesDoor U-factor table for values,
U-u-_
Etrtot
Does Not
iENot observablelFRllr0
1.1,
3.4
402.L.L,
402.3.L,
402.3.3,
402.5
lFR2l1e
See the Envelope Assemblies
table for values.
U-U-Glazing U-factor (area-wei ghted
average).
flNot Observable
ENot Applicable
Complies
Does Not
EComplies
EDoes Not
ENot Observable
!Not Applicable
303.1,.3
lFR4l1
e
U-factors of fenestration products
are determined in accordance
with the NFRC test procedure or
taken from the default table.
EComplies
nDoes Not
ENot Observable
flNot Applicable
402.4.I.1 iAir barrier and thermal barrier
lFR23l1 iinstalled permanufacturer's
O i instructions.
i
plies
Not
Observable
Applicable
402.4.3
lFR20l1
o
Fenestration that is not site built
is listed and labeled as meeting
AAMA A /DMA/CSA L0l./1.s.2/A440
or has infiltration rates per NFRC
400 that do not exceed code
limits.
EComplies
EDoes Not
tlNot Observable
flnot Applicable
lC-rated recessed lighting fixtures
sealed at housing/interior finish
and labeled to indicate <2.0 cfm
leakage at 75 Pa.
Ecomplies
EDoes Not
ENot observable
ENot Applicable
Supply and return ducts in attics
insulated >= R-8 where duct is
>= 3 inches in diameter and >=
R-6 where < 3 inches. Supply and
return ducts in other portions of
the building insulated >= R-6 for
diameter >= 3 inches and R-4.2
for < 3 inches in diameter.
403.3.1
lFR12l1
&
403.3.2
lFRr.3lt
$
Ducts, air handlers and filter
boxes are sealed with
joints/seams compliant with
lnternational Mechanical Code or
lnternational Residential Code, as
a ble.
EDoes Not
Complies
Not Observable
Not Applicable
lDoes Not
!Not Observable
nNot npplicable
CompliesBuilding cavities are not used as
ducts or plenums.
HVAC piping conveying fluids
above 105 sF or chilled fluids
below 55 cF are insulated to >R-
3.
iEComplies
ilooes tttot
iEltot observable
iEruot epplicabte
R-R-
403.4.!
lFR24l1
s
Protection of insulation on HVAC
piping.
lNot Observable
ENot Applicable
Complies
Does Not
!Complies
lDoes Not
ENot Observable
INot Applicable
R-R-Hot water pipes are insulated to
>R-3.
,l i r:
..i. ir
Medium lm (Tier 2)Low I act (Tier 3)1 (Tier 1)H
Project Title: doka
Data filename:
Report date: lU0Ll23
Page 5 ofL0
or gravity dampers are
installed on all outdoor air
intakes and exhausts.
plies
Not
Observable
Applicable
Additional Comments/Assumptions:
1 (Tier L)Medium lmpact (Tier 2)Low lmpact (Tier 3)
Project Title: doka
Data filename:
Report date: LUOL|23
Page 6 ofl0
I installed insulation is labeled
or the installed R-values
provided.
Does Not
Not Observable
plies
bleNot
402.L.L,
402.2.5,
402.2.6
lrN3lrs
Wall insulation R-value. lf this is a
mass wall with at least % of the
wall insulation on the wall
exterior, the exterior insulation
requirement applies (FR10).
R.R-itr
I
ENot Applicable
see the Envelope Assemblies
table for values.I Wood
I Mass
! Steel
! Wood
! Mass
I Steel
Does Not
Not Observable
Does Not
Not Observable
Not Applicable
pliesWall insulation is installed per
manufacturer's instructions.
303.2
ltN4l1
Additional Comments/Assumptions:
Medium ct (Tier 2)(Tier 3)LowLHigh lmpact (Tier L
Project Title: doka
Data filename:
Report date: ILl0Ll23
Page 7 ofL0
402.\.L,
402.2.L,
402.2.2,
402.2.6
lFl].]1
iEComplies
ilDoes wot
iEruot observable
inruot appticabte
iceiting insulation R-value.R-R-
Wood
Steel
See fhe Envelope Assemblies
table for values,Wood
Steel
303.1.1.1,
303.2
lFt2ll
Ceiling insulation installed per
manufacturer's instructions.
Blown insulation marked every
300 ftr.
Vented attics with air permeable
insulation include baffle adjacent
to soffit and eave vents that
extends over insulation.
Does Not
nNot Observable
!Not applicable
Attic access hatch and door
insulation >R-value of the
adjacent assembly.
EComplies
EDoes Not
ENot Observable
ENot Applicable
R-R.402.2.4
lFt3ll
Blower door test @ 50 Pa. <=5
ach in Climate zones 'l'-2, and
<=3 ach in Climate Zones 3-8.
ElDoes Not
ENot observable
ENot Applicable
ACH 50 =ACH 50 =402.4.'J,.2
lFI]_7]1
Ducts are pressure tested to
determine air leakage with
either: Rough-in test: Total
leakage measured with a
pressure differential of 0.1 inch
w.g. across the system including
the manufacturer's air handler
enclosure if installed at time of
test, Postconstruction test: Total
cfm/100 cfm/100
ft2E-Complies403.3,3
lFt2Tlt
ileakage measured with a
ipressure differential of 0.1 inch
;w.g. across the entire system
iincluding the manufacturer's air
ihandler enclosure.
nDoes Not
ENot Observable
ENot Applicable
iDuct tightness test result of <=4
icfm/L00 ft2 across the system or
i<=3 cfm/100 ft2 without air
i handler @ 25 Pa. For rough-in
EComplies
EDoes Not
nNot Observable
nNot Applicable
cfm/100 cfm/100fr2-ftz-
verification toneedtests,may
doccur
403.3.4
lFt4l1
flDoes Not
f]Not Observable
blefltrtot
Air handler leakage designated
by manufacturer at <=2o/o of
design air flow.
403.3.2.t
lFt24l1
EComplies
lDoes Not
E]Not observable
ENot Applicable
Programmable thermostats
installed for control of primary
heating and cooling systems and
initially set by manufacturer to
code specifications.
EComplies
nDoes Not
!Not Observable
!Not Applicable
Heat pump thermostat installed
on heat pumps.
Does Not
flNot Observable
Not Applicable
Circulating service hot water
systems have automatic or
accessible manual controls.
Medium I (Tier 2)(Tier 3)Low1r1)High lmpact
Project Title: doka
Data filename:
Report date: LLlO]-lz3
Page 8 of10
Plans Verified
Value
Field Verified
Value Complies?
Section
#
& Req.lD
Final lnspection Provisions Comments/Assumptions
All mechanical ventilation system i
,fans not part of tested and Iisted ;
HVAC equipment meet efficacy i
tand air flow limits per Table I
R403.6.1.
;nComplies
jnDoes Ltot
LlNot Observable
,nNot npplicable
403.6.1
lFr2 5 t?
Hot water boilers supplying heat ;
through one- or two-pipe heating i
systems have outdoor setback
control to lower boiler water :
temperature based on outdoor
lComplies
nDoes Not
nNot Observable
nNot Applicable
temperature
403.2
lFt2612
:Heated water circulation systems
, have a circulation pump. The
,system return pipe is a dedicated
rreturn pipe or a cold water supply'pipe. Gravity and thermos-
:syphon circulation systems are
not present. Controls for
, circulating hot water system
;pumps start the pump with signal
;for hot water demand within the
403.5.1.1
IFr2812
occupancy. Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
Complies
Does Not
Not Observable
Not Applicable
403.5.1.2 'Electric heat trace systems
lFl29l'? qcomply with IEEE 515.1 or UL
: 5L5. Controls automatically
; adjust the energy input to the
r heat tracing to maintain the
:desired water temperature in
piping.
nComplies
EDoes Not
nNot Observable
nNot Applicable
thel
Demand recirculation water
:systems have controls that
imanage operation of the PumP
, and limit the temperature of the
nDoes Not
nNot Observable
nNot Applicableiwater
plies403.5.2
lFl30l2
entering the cold water
to <= 104sF.
tespl
NotDoes
Drain water heat recovery units
three or more showers.
403.5.4
lFl3112
nNot Observable
[1Not Applicablerecovery units < 3 psi for
individual units connected to one
or two showers. Potable water-
Itested in accordance with CSA
' ASS.t. Potable water-side
I pressure loss of drain water heat
,side pressure loss of drain water
iheat recovery units < 2 psi for
'individual units connected to
es
N ot
90%o or more of permanent
fixtures have high efficacy lamps
404.L
lFt6l1
nNot Observable
nruot npplicable
404.1,1
lFt2 3l3
v,
nComplies
nDoes Not
nNot Observable
nNot Applicable
Fuel gas lighting systems have
no continuous pilot light.
nDoes Not
nNot Observable
nNot Applicable
Compliance certificate posted.omplies401.3
lFtT)2
1 High lmpact (Tier 1)2 Medium lmpact (Tier 2)3 Low lmpact (Tier 3)
Project Title: doka
Data filename:
Report date: ]-]-l0]-123
Page 9 of10
Does Not
Not Observable I
Not cable
Manufacturer manuals for
mechanical and water heating
systems have been provided.
Additional Comments/Assumptions :
(Tier 3)LowMedium lmpact (Tier 21High I l_)
Project Title: doka
Data filename:
Report date: L]..l0]-l23
Page 10 of10
fr 2018 IECC Energy
Effi ciency Certificate
Above-Grade Wall
Below-Grade Wall
Floor
Ceiling / Roof
Ductwork (unconditioned spaces):
Window
Door
Heating System:
Cooling System:
Water Heater:
Name:
Comments
20.00
o.oo
o.oo
49.OO
o.27
o.27
Date:
R-Valuelnsulation Rating
Glass & Door Rating U-Factor SHGC
EfficiencyHeating & Cooling Equipment