HomeMy WebLinkAboutOWTS Permit Card
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945‐6614 ext. 8150
For inspections, call: 970‐945‐6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: 2255 County Road 226 Rifle, CO 81650 Parcel No.: _212702400131
Owner Name: Lee Sedota Owner Phone: (970) 401‐2560
Designed By: K‐Cronk Engineering Designer Phone: (970) 250‐0572
Number of Bedrooms: _5_ Minimum Tank Capacity: 1,500‐gallon Minimum Absorption: 960 ft2
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number _SEPT‐8563_______________________________
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date _03/22/2024____________________ Expiration Date_03/22/2025_________________
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the report and design as
submitted by K‐Cronk Engineering dated February 16, 2024 and updated March 22, 2024. Changes to
the design and permit must be approved by Garfield County Public Health and the designer prior to
construction.
The new OWTS will serve an existing five‐bedroom residence and replace the existing OWTS on the
property. The system will consist of a new, single‐compartment 1,000‐gallon septic tank set level
with access at grade and an effluent filter in the outlet tee of the tank followed by a two‐
compartment 1,000‐gallon septic tank set level with access to grade and a high‐head pump in the
second compartment of the tank. Effluent will be pumped to a level manifold that will distribute
effluent to 960 ft2 of STA. The new STA will consist of four gravelless chamber trenches, each trench
consisting of 20 Quick4 chambers per trench (80 Quick4 chambers total). Distribution laterals are to
be 1 ½ inch Schedule 40 PVC, with 5/32‐inch orifices 4‐feet on center and the laterals ending in 90‐
degree bends and flushing valves at the distal end of the laterals. Laterals are to be hung from the
underside of the chambers with zip‐ties. The orifices are to be facing upward. Inspection ports are to
be installed at each end of each trench. Maintain all setbacks and elevations as designed.
Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final
inspection of the installed system prior to backfill. NO OWTS COMPONENT SHALL BE BACKFILLED
WITHOUT PRIOR APPROVAL FROM GARFIELD COUNTY PUBLIC HEALTH AND THE DESIGNER.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction, and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection,
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as‐built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
03/22/2024
Issued By: Garfield County Environmental Health
Department
Date