Loading...
HomeMy WebLinkAboutRes Check Report,(gSd',eck- REScheck Software Version 4.7.O Com pl ia nce Cettificate Project DEBOOY RESIDENCE Energy Code: 2015 IECC Location: Glenwood Springs, Colorado Construction Type: Single-family Project Type: New €onstruction Conditioned FloorArea: O ft2 Glazing Area L7o/o Climate Zone: 5 (7313 HDD) Permit Date: Permit Number: Construction Site: 392 RIVER BANK LANE GLENWOOD SPRINGS, CO 81601 Owner/Agent: PETER DEBOOY PETEl 7342002@YAHOO.COM Desig ner/Contractor: BRAD JORDAN JORDAN ARCHITECTURE INC. PO BOX 1031 GLENWOOD SPRINGS, CO 8].602 9706186690 B RADJ ORDANARCH ITECT@GMAI L.C OM \ $ st\Compliance: Passes using UA trade-off Compliance: 8,57o BetterThan Code Maxitnum UA: 551 Your UA: 5o4 The % Better or Worse Than Code lndex reflects how close to compliance the house is based on code trade-off rules. It DOES NOTFrovide an estimate of energy use or cost Felative to a minimum-code home. Envelope Assemblies Ceiling 1: Flat Ceiling or Scissor Truss Wall 1:Wood Frame, 16" o.c. Window 1: Metal Frame with Thermal Break:Double Pane with Low-E Door 1: Solid Wall 2: Wood Frame, 16" o,c, Window 2: Metal Frame with Thermal Break:Double Pane with Low-E Door 2: Glass Wall 3: Wood Frame, 16" o.c. Window 3: Metal Frame with Thermal Break:Double Pane with Low-E Door 3: Glass Wall 4: Wood Frame, 16" o.c. Window 4: Metal Frame with Thermal Break:Double Pane with Low-E Basement Wall L: Wood Frame Wall height: 8.0' Depth below grade: 6.0' lnsulation depth: 8.0' 2,24L 888 52 24 945 234 90 r,220 207 40 1,151 75 718 0.026 0.059 0.280 0.500 0.059 0,280 0.280 0,059 0.280 0.280 0.059 0.280 0.032 58 48 15 12 37 66 25 57 58 11 63 2L 23 49.0 20.0 0.0 0.0 s\ s 20.0 0.0 20.0 0.0 20.0 0.0 10.0 Gross Area or Perimeter Cavity R-Value Cont. R-ValueAssembly U-Factor UA 19.0 Project Title: DEBOOY RESIDENCE Data filename: Untitled.rck Report date: 04lOLl24 Page I of10 Gross Area or Ferimeter Cavity R-Valuo Cont, R-V.rlrroAssembly U-Factor UA Crawl 1: Solid Concrete or Masonry 857 19.0 10.0 0.035 10 Wall height: 6.0' Depth below grade: 6.0' lnsulation depth: 4,0' Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in REScheckVersion 4.7.0 and to complywith the mandatory requirements listed in the RESchecklnspection Checklist. ARCHITECT E"aZ 01 APRTL 2024 Name - Title Date .rl./, ,- .. t (i ,F d" 'j ,i+ { ,'' a Project Title: DEBOOY RESIDENCE Data filename: Untitled,rck Report date: O4loll24 Page 2 of10 REScheck Software Version 4,7,O Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Additional Com ments/Assum ptions : S6dion* & Reo.lD Pre-lnspection/Plan Bevlaw PlanE Verifled Value Fleld Verified IValue I Complles?Comments/Assumptions 103.1, 103.2 lPR1l1 @ I Construction drawings and I documentation demonstrate energy code compliance for the building envelope. Thermal envelope represented on construction documents. Complies nDoes Not nNot Observable nNot Applicable 103,1, 103,2, 403.7 lPR3llg , Construction drawings and i documentation demonstrate 'energy code compliance for rlighting and mechanical systems, , Systems serving multiple :dwelling units must demonstrate compliance with the IECC Commercial Provisions, Complies lDoes Not ot Observable ot Applicable 302.1, 403.7 lPR2l2 @ Heating and cooling equipment is sized per ACCA Manual S based Heating: Btu/hr- Heating: Btu/hr_ Cooling: Btu/hr_ incomplies inoo"t tttot inNot observable ilNot Applicable on loads calculated per ACCA'Manual J or other methods 'approved by the code official, Cooli ngBtu/hr_ 2 Medium I (Tier 2)3 Low lm ct (Tier 3)1 High lmpact (Tier 1) Project Title: DEBOOY RESIDENCE Data filename: Untitled.rck Report date: 04lOLl24 Page 3 ofL0 Sectlon # & Reo.lD Foundnllon lnspqrfion Plane Virlflod Value Compller?c onr Dr6nts/Asg'u n ptl onsFleld Verlfled Value Conditioned basement wall insulation R-value. Where interior insulation is used, verification may need to occur during lnsulation lnspection. Not required in warm-humid locations in Climate Zone 3. nn n tr Complies Does Not Not Observable Not Applicable iSee the Envelope Assemblies table for values. R- R- 402.1.1 IF04]1 & R- R- 303.2 lFo5ll s Conditioned basement wall insulation installed per manufacturer's instructions. !Complies nDoes Not INot Observable nNot Applicable 402.2.9 lFo6lr s Conditioned basement wall insulation depth of burial or distance from top of wall. incomplies i[]ooes ttot inruot observable inNot Applicable ft ft See the Envelope Assemblies table for values. 402.2.rL lFo7l1 @ See the Envelope Assemblies table for values. R-R- R- res Not inNot observable Applicable Unvented crawl space wall insulation R-value. 303,2 lFoSli \g ,Unvented crawl space wall ; insulation installed per i manufacturer's instructions. nComplies nDoes Not nNot Observable [Jtrtot Applicable 402.2.rr lFo9l1 ,s} : Unvented crawl space continuous 'vapor retarder installed over exposed earth, joints overlapped I by 6 in. and sealed, extending at least 6 in. up and attached to the wall. ncomplies nDoes Not nNot Observable nNot Applicable 402.2.tI lFo10l1 ,gr ilcomplies inDoes Not iltrtot observable inNot Applicable See the Envelope Assemblies table for values. tn.tnI Unvented crawl space wall insulation depth of burial or distance from top of wall. 303.2.1 IFO11]2 rg tA protective covering is installed to protect exposed exteriorrinsulation and extends a minimum of 6 in. below grade. nDoes Not nNot Observable flNot Applicable plies 403.9 lFot2l2 @ nComplies nDoes Not nNot Observable nNot Applicable Snow- and ice-melting system controls installed. Additional Comments/Assumptions : 1 High lmpact (Tier I)Low lmpact (Tier 3)2 Medium lmpact (Tier 2)3 Project Title: DEBOOY RESIDENCE Data fi lename: Untitled.rck Report date: O4lOLl24 Page 4 ofL0 Section # & Reo.lD Framing / Rough-ln lnspection Plans Verified Value Field Verified Value Complies?Com ments/Assu m pti ons 402.L.7, 402.3.4 lFRlli ,t| Door U-factor U-U nComplies nDoes Not !Not Observable ENot Applicable See the Envelope Assemblies table for values. 402.L.L, 402.3.L, 402.3.3, 402.5 lFR2ll ,.g/ Glazing U-factor (area-weighted average). U-U !Complies nDoes Not nNot Observable nNot Applicable See the Envelope Assemblies table for values. 303.1.3 lFR4l1 S/ U-factors of fenestration products are determined in accordance with the NFRC test procedure or taken from the default table. nComplies nDoes Not !Not Observable Eruot Applicable 402.4.r.r lFR23lr .u/ Air barrier and thermal barrier installed per manufacturer's instructions. !Complies nDoes Not nNot Observable !Not Applicable 402.4.3 lFR20l1 Sr Fenestration that is not site built is listed and labeled as meeting AAMA /WDMA ICSA tlt lt.s.2 I A44O nComplies EDoes Not ENot Observable ENot Applicableor has infiltration rates per NFRC 400 that do not exceed code limits. 402.4.5 lFR16l2 lC-rated recessed lighting fixtu res nComplies nDoes Not nNot Observable nNot Applicable sealed at housing/interior finish , and labeled to indicate <2.0 cfm : leakage at 75 Pa. 403.3.1 lFRl2li .$, Supply and return ducts in attics insulated >= R-8 where duct is >: 3 inches in diameter and >= R-6 where'< 3 inches. Supply and return ducts in other portions of the building insulated >= R-6 for diameter >= 3 inches and R-4.2 for < 3 inches in diameter. nComplies nDoes Not nNot Observable nNot Applicable 403.3.5 lFR15l3 u,, Building cavities are not used as ducts or plenums. nComplies nDoes Not nNot observable nNot Applicable 403.4 lFR17l2 gr HVAC piping conveying fluids above 105 eF or chilled fluids below 55 oF are insulated to >R- 3. R-R-nComplies nDoes Not nNot Observable ENot Applicable 403.4.r lFR24lr .e' Protection of insulation on HVAC piping. nComplies nDoes Not nNot Observable !Not Applicable 403.5.3 lFR18l2 ,.9, Hot water pipes are insulated to >R-3. R-R-nComplies nDoes Not nNot Observable nNot Applicable 403.6 lFRt 9l2 Automatic or gravity dampers are installed on all outdoor air intakes and exhausts. ncomplies nDoes Not nNot Observable ENot Applicable 3 (Tier 3)Low1ct (Tier 1)Hi hlm 2 Medium (Tier 2) Project Title: DEBOOY RESIDENCE Data filename: Untitled.rck Report date: 04lOIl24 Page 5 of10 Additional Com ments/Assumptions: 1 (Tier 1)Hi hlm 2 Medium I (Tier 2)3 Low lm ct ffier 3) Project Title: DEBOOY RESIDENCE Data filename: Untitled.rck Report date: O4lOIl24 Page 6 of1.0 tes Not Observable cable All installed insulation is labeled or the installed R-values provided. Wall insulation R-value. lf this is a mass wall with at least % of the wall insulation on the wall exterior, the exterior insulation requirement applies (FR10), iENot observable jEruot npplicable See the Envelope Assemblies table forvalues. R.R- nn! Wood Mass Steel Not tes .2.6 ! Wood ! Mass ! Steel 402.L.t, 402.2.5, IN3IT € plies Not Observable Applicable Wall insulation is installed per m anufacturer's i nstructions,llN4l1 Additional Comments/Assu mptions: (Tier 3)Low1hlmer 1)H ffier 2)Medium Project Title: DEBOOY RESIDENCE Data filename: Untitled.rck Report date: O4lOLl24 Page 7 of10 GompllFs?Commenti/Assumptlons 442.1.L, 402.2.L, 402.2.2, 402.2.6 lFt1l1 iEComplies isee the Fnvelope Assemh/ies ilDoes tr.tot ',table for values' iEtrtot observable i iEnot applicable i i Ceiling insulation R-value R-- I Wood n Steel R-_ ! Wood n Steel 303.1.1.1, 303,2 lFt2l1 Ceiling insulation installed per manufacturer's instructions. Blown insulation marked every 300 ft,. nComplies lDoes Not nNot Observable nNot Applicable Vented attics with air permeable ' insulation include baffle adjacentito soffit and eave vents that r extends over insulation. nComplies lDoes Not lNot Observable nNot Applicable 402,2.3 IFt2212 flComplies nDoes Not nNot Observable nNot Applicable R-R-Attic access hatch and door402.2.4 lFt3lr insulation >R-value of the adjacent assembly. Blower door test @ 50 Pa. <=5 I ACH 50 = ach in Climate Zones L-2, and <=3 ach in Climate Zones 3-8. ACH 50 =402.4.L.2 lFt 17 11 nComplies nDoes Not nNot Observable I lNot Applicable ; Duct tightness test result of <=4 cfm/LO0 ft2 across the system or <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in tests, verification may need to nComplies nDoes Not !Not Observable nNot Applicable cfm/l00rt- occur durin Fram 403.3.4 lFt4l1 on. _ cfm/L00 ft2 Ducts are pressure tested to determine air leakage with either: Rough-in test: Total leakage measurEd with a pressure differential of 0,1 inch ,w.9. across the system including the manufacturer's air handler enclosure if installed at time of I test. Postconstruction test: Total ;leakage measured with a :pressure differential of 0.1 inch ,w.9, across the entire system 'including the manufacturer's air I handler enclosure. cfm/100 cfm/100 ft2 ft2 403.3.3 lFtzTlL incomplies jnoo"r ltot nNot Observable nNot Applicable Air handler leakage designated by manufacturer at <=2o/o of design air flow. plies Not 403.3,2.1 lFt24ll Observable Applicable Programmable thermostats installed for control of primary heating and cooling systems and linitially set by manufacturer to code specifications. plies Not 403.1.1 lFt9l2 observable Applicable plies Not 403,L.2 lFt10l2 Heat pump thermostat installed on heat pumps. Observable Applicable I Circulating service hot water lsystems have autorrratic or accessible manual controls. plies Not 403,5.1 lFt1r.12 Observable r Applicable i lmHi erL 2 31Medium I Low 3 Project Title: DEBOOY RESIDENCE Data filename: Untitled.rck Report date: 04lOLl24 Page 8 of10 Section # & Req.lD Final lnspection Provisions Plans Verified Value Field Verified Value Complies?Comments/Assumptions 403.6.1 lFr2sl, All mechanical ventilation system : fans not part of tested and listed HVAC equipment meet efficacY . and air flow limits. nComplies !Does Not !Not observable nNot Applicable 403.2 lFt26l2 Hot water boilers supplying heat through one- or two-pipe heating systems have outdoor setback control to lower boiler water temperature based on outdoor temperature. nComplies nDoes Not !Not Observable nNot Applicable 403.5,1.1 lFt2812 Heated water circulation systems : have a circulation pump. The system return pipe is a dedicated return pipe or a cold water supply nComplies lDoes Not nNot Observable ENot Applicablepipe. Gravity and thermos- syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pumP when water is in circulation looP is at set-point temperature and no demand for hot water exists. 403.5.t.2 lFt2912 Electric heat trace systems comply with IEEE 515.1 or UL 515. Controls automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the . piping. !Complies nDoes Not nNot Observable nNot Applicable 403.5.2 lFt30l, Water distribution systems that have recirculation pumps that pump water from a heated water supply pipe back to the heated water source through a cold water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold !Complies nDoes Not !Not Observefble nNot Applicable water piping to 104sF 403.5.4 IFI3I ]2 Drain water heat recovery units : tested in accordance with CSA 855. 1. Potable water-side pressure loss of drain water heat recovery units < 3 psi for individual units connected to one or two showers. Potable water- side pressure loss of drain water , heat recovery units < 2 psi for ' individual units connected to three or more showers. nComplies nDoes Not nNot Observable nNot Applicable 404.r lFt6l1 75o/o of lamps in permanent : fixtures or 75Yo of permanent : fixtures have high efficacy lamPs. : Does not apply to low-voltage EComplies IDoes Not !Not Observable nNot Applicablelishting 404.t.t lFt23l3 .v,, Fuel gas lighting systems have no continuous pilot light. !Complies nDoes Not ENot Observable nNot Applicable 1 High lmpact (Tier 1)2 Medium lmpact (Tier 2)3 Low lmpact (Tier 3) Project Title: DEBOOY RESIDENCE Data filename: Untitled.rck Report date: 04l0ll24 Page 9 of10 Sectlon # & Reo.lD Flnal lnspectlon Provlslon$Plane Verifled Value Fleld Vcrlfled Value Complies?Comments/Agsumptlong 401.3 lFr7l2 Compliance certificate posted nComplies nDoes Not nNot Observable nNot Applicable 303.3 lFt18l3 i Manufacturer manuals for :mechanical and water heating :systems have been provided. lComplies lDoes Not lNot Observable lNot Applicable Additional Com ments/Assumptions: 1 (Tier 1)Hi ht Medium lmpact ffier 2)3 Low lmpact ffier 3) Project Title: DEBOOY RESIDENCE Data filename: Untitled.rck Report date: O4lOLl24 Page L0 of10 2015 IECC Energy Efficiency Gertificate Above-Grade Wall Below-Grade Wall Floor Ceiling / Roof Ductwork (unconditioned spaces): Window Door Heating System Cooling System Water Name Comments 20.oo 29.OO o.oo 49.OO o.28 o.28 Date: R-Valuelnsulation Rating U-Factor SHGCGlass & Door Rating EfficiencyHeating & Cooling Equipment