HomeMy WebLinkAboutApplicationGarfield County
Community Development Department
108 8th Street, Suite 401
r" i Gtenwood Springs, CO 81601
- (9701945-82t2
l'lAF( 1 ulw{I}?farr,eta-counw.com
,-;,: :..i ; 1,'. -:; i; i;
BUILDING PERMIT
APPLICATION
Commercial/Multi-Family Demolition
Manufactured Home or Tiny Home (Single or Multi-Level)
T Residential (SF, Duplex or Townhomelsr Reroof
Accessorv Dwellins Unit (ADU) - MAXIMUM SIZE OF 1,200 SQUARE FEET
INVOLVED PARTIES
Linda and Brian Gammill
11722 Forest Glen Street, Houston, TX77024
phone:(713 1270-3321
Email Addresr. Brian.Gammill@transwestern.com
Property Owner:
Mailing Address:
310 Market St, Basalt, CO 81621
353-8622Contrastor:Peak3, Ltd - Jetf Claflin Phone:720
Maillng Address:
EmailAddress:jeff@peak3aspen.com
Architect: Artful Dwellings - Ashley Adams
322 Sopris Circle, Basalt, CO 81621
phone: (251 1767-5971
Emait Addresr. ashley@artfuldwellings.com
Mailing Address:
DB Structural Design - Nate Decker 801 529-6481Phone:Englneer:
Mailing Address:1229 Sage Ct, Rifle, CO 81650
EmailAddress:nate@dbsd.com
EmailAddress:
Phone: ( I
Malling Address:
Manufactured Home lnrt"ll"r, N/A
New 2-story S/F dwelling on lot 34 of Aspen Glen PUD with 4,112 SF gross area
Job Address: 567 Saddleback Rd, Carbondale, CO 81623
owney's Valuation of wor r, S 311 , O 5i " Z0 Property size (sq. Ft. or Acresf :
including 546 SF attached garage space.
ru6. Aspen Glen PUD
0.33 Acres
Height:
Describe Work:
Sq. Ft. of Bullding:4,112 SF Gross
Assessol's Parcel Number: 239513407004
24'.-9"# of Floors:2
tot 54 Btock
Class of Work:{New Remodel/Alteration Addition
V
Garage:Detached
PROJECT DETAITS CONTINUED
Septic:Community
Type of Heat:Gas Propane Electric Other
Driveway
Permit:
Permit #:
NOTICE
AuthorlW. This application for a Building Permit must be signed by the Owner of the property, described above,
oranauthorizedagent. lfthesignaturebelowisnotthatoftheOwner,aseparateletterofauthority,signedby
the Owner, must be provided with this Application.
Legal Access. A Building Permit cannot be issued without proof of legal and adequate access to the property for
purposes of inspections by the Building Division.
Other Permits. Multiple separate permits may be required: (1) State Electrical Permit, (2) County OWTS Permit,
(3) another permit required for use on the property identified above, e.g. State or County Highway/ Road Access
or a State Wastewater Discharge Permit.
Void Permit. A Building Permit becomes null and void if the work authorized is not commenced within 180 days
of the date of issuance and if work is suspended or abandoned for a period of 180 days after commencement.
I hereby acknowledge that I have read and understand the Notice and Certification above, as well as, have
provided the required information which is correct and accurate to the best of my knowledge.
s/b /24
Propefi Owner Print and Sign Date
CERTIFICATION
I hereby certify that I have read this Application and that the information contained above is true and correct. I
understand that the Building Division accepts the Application, along with the plans and specifications and other data
submitted by me or on my behalf (submittals), based upon my certification as to accuracy. Assuming completeness
of the submittals and approval of this Application, a Building Permit will be issued granting permission to me, as
Owner, to construct the structure(s) and facilities detailed on the submittals reviewed by the Building Division. ln
consideration of the issuance of the Building Permit, I agree that I and my agents will comply with provisions of any
federal, state, or local law regulating the work and the Garfield County Building Code, OWTS regulations and
applicable land use regulations (County Regulation(s)). All County development requiring a permit, except for
residential uses, are subject to Article 7 of the Land Use and Development Code. I acknowledge that the Building
Permit may be suspended or revoked, upon notice from the County, if the location, construction or use of the
structure(s) and facility(ies), described above, are not in compliance with County Regulation(s) or any other
applicable law.
I hereby grant permission to the Building Division to enter the property, described above, to inspect the work. I
further acknowledge that the issuance of the Building Permit does not prevent the Building Official from: (1) requiring
the correction of errors in the submittals, if any, discovered after issuance; or (2) stopping construction or use of the
structure(s) or facility(ies) if such is in violation of County Regulation(s) or any other applicable law. Review of this
Application, including submittals, and inspections of the work by the Building Division do not constitute an
acceptance of responsibility or liability by the County of errors, omissions, or discrepancies. As the Owner, I
acknowledge that responsibility for compliance with federal, state and local laws and County Regulations rest with
me and my authorized agents, including without limitation my architect designer, engineer and/ or builder.
OFFICIAT USE ONIY \l"t I
speciarconditions:,eee atbarhd e7y2r777A17e
Adiusted Valuation: .-
3 tQ.05?s.za i'aFci++'ey,2"t,75 Manu. Holne Fee:NA Misc. Fees:RIFEB>+z,7't"t'5;5i,2'f?
".{
Fees Paid:
l{,Hb a
Bafance Duei -e2225, l',ffiE-gs"+OWTS No:n+t"to"ffirrvD OCC Group:IBD Const. rrr", /BC 'Ttis
C,r,t/frf/n
Signed Approval
BUTTDTNG / PTANNtNG DTV|STON :-2
Date
@
ENERGY COMPL|ANCE SHEET REQUIREMENTS:
Effective June 30, 2023Please provide details showing how building complies / meets Garfield County's
adopted 2018 IECC and 9!!@!g.,.@!.
Depict and show outline the structure's building thermal envelope. Outline should clearly show portions
of the building to be conditioned inside the envelope (and label or otherwise identiff any areas remaining
unconditioned outside this envelope)
Energy Compliance Plan should further include:
Chosen Energy Compliance Patho Prescriptive: Cross Sections of insulated assemblies including the selected material/ R-Value
and U-Values to comply with IRC Table R402.1.2o U-Factor Alternative: Provide a Rescheck Reporto Total U-Factor Altemative: Provide software generated submiftal design reports and inspection
checklist for any RESNET ERI index or other performance path designs
Air sealing details around openings, pipes, penetrations, joints
Fenestration U-factors
Provide mechanical system design details including proposed efficiency rates, types of equipment, fuel
types, locations
Energy efficient lighting specifications - 90% to be high-efficacy (LED complies)
Manual J Report required for new building structures and new equipment installations.
STRUCTURAL PLANS: Please provide the following information on the structural plans.
o SOILS REPORT - lf the project is located in a subdivision with a final plat requiring site specific
soils investigation report or if Structural plans make a specific reference to a soils report, then a
copy of the soils report is required to submit a building permit application.o Design specifications to include roof and deck snow load, wind and seismic design and frost
depth.. Foundation plan showing complete footing and foundation dimensions.o Footing and foundation details speciffing reinforcement and referenced on plans.
o Framing plans for each floor level and roof. All beams, columns, joists, rafters and trusses
specified. Pre-manufactured structures require the engineers stamp, signature and date.o Framing /connection details, braced wall lines, shear wall schedule, location and hold downs.
NOTEI lf any required information is missing, delays in issuing the permit are to be expected. lf
determined by the Building Official that additional information is necessary to review the application
and/or plans for compliance, the application may be placed on hold until the required information is
provided. Work may not proceed without the issuance of a permit.
The Building Division will collect a Plan Review fee at time of application submittal. The permit fee, as
well as any Road lmpact fees will be collected when the permit is issued.
The permit application must be signed by the owner or by person having written authority from the owner
to act as their representative.
Building cannot be occupied until a Certificate of Occupancy (CO) is issued. Using the building without a
CO will be considered an illegal occupancy and may be grounds for vacating the premises. (Final/CO
inspection requirements will be attached to your approved field set of plans.)
I hereby acknowledge I have read, understand and will abide by the requirements of this
checklist.
Owner Print:Sign:
oN'I BEt+frLr oF Fruftu Qn nrwtu
4
Gurficld CountY
BUILDING DEPARTMENT
l}g Eighth Street, Saite 4Ot, Glenwood Springt CO 87507
Tel: (970) 945-8272
PlA N REVI EW CHE CKLIS T
Permit No: OtRg-,3 -2#8567
Building lssues
Driveway Permit
NA
Surveyed Site Plan
Septic Permit and Setbacks
Grade/ Topography 30%
zt' SuMivisio* Plat Notes
Fire DePartment Review
Engrneered Fot"+*dation
Valuation Determination/ Fees
Red Line Plans/ StamPs/ Sticker
Attach Conditions
Pf anning lZoning lssues
lal-5-(
C 0/l/Prroperry Line setbacks
35 ft. Stream Setbacks
Nr+ Flood Plain
Utlp Buitding Height
Zoning Sign-Off
556A6r
RrFsep:
Descri otion & Sum marv:
ry
Attach Residential Plan Review List U4' Road lmpact Fees (rr ezb$4tos
Grade/ ToPograPhY 40%
Planning lssues
1',- subdivision Plat
//
( l\lD
\11
ApplicationSigned .t /'rnanuoy'-Ts,*hniH
trLs s*(ox 74 68=
fltlgy t8 =
e/a x 5z #
a56 x /g /
/ega, 6ff.z'
/ 08r'6/0, oo
lan r to Sign
ParcellSchedule No.
40# Snowload Letter - Manuf. Homes
Soils Report f
/4qzz
/2 628,o0
/, y'6/,oo
rhdor/e .e7o*
0FEru-hiCILE SSll-$ RF,p0RT
I$ hTEQUIREN AT I:OOTING
t N $FEc'tr! nw €L-Q-*P #'r
709, ou
tzz x /Z
7lfuosE u