HomeMy WebLinkAboutConditions of PermitCOND ITIONS OF PERM IT
BLRE-03 -24-857 0
MARIA KOZIOL
New Single-family dwelling w/ attached garage
143 Maroon Dr, GWS
Four Mile Ranch, Lot 30
1 ) ALL WORK SHALL COMPLY WITH THE 2015 INTERNATIONAL RESIDENTIAL CODE (I.R.C.) AND 2018
INTERNATIONAL ENERGY CONSERVATION CODE (I.E.C.C.)
2) PROpOSED TMPROVEMENTS ARE SUBJECT TO ALL APPLTCABLE ITEMS CONTAINED lN THE
ATTACHED "GARFIELD COUNry BUILDING REOUIREMENTS". NUMBER REFERENCES NOTED ON
PLANS REFER TO SPECIFIC ITEMS ON THIS LIST.
3) ELECTRTCAL pERMtTTtNG AND TNSPECTTONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL
ROUGH.IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINALAPPROVAL IS
REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY.
4) ALL EXTERIOR LIGHTING TO BE DOWNCAST AND SHIELDED.
5) WILDFIRE MITIGATION RECOMMENDATIONS: SHOULD COMPLY WITH WILDFIRE MITIGATION AND
DEFENSIBLE SPACE RECOMMENDATIONS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE
DISTRICT. PLEASE REFER TO THE GARFIELD COUNTY COMMUNITY DEVELOPMENTWEBSITE FOR
ADDITIONAL I N FORMATION.
6) OPEN HOLE SOTLS REPORT tS REOUTRED AT FOOTTNG INSPECTION AND PRIOR TO ANY CONCRETE
POUR. PROVIDE COPY OF GEOTECHNICAL ENGINEERS REPORTTO THE BUILDING INSPECTOR.' 2,000 PSF soil bearlng.
7) PRE-ENGTNEERED ROOF TRUSSES. HAVE ENGTNEERING FOR BUILDING INSPECTOR AT TIME OF
FRAME INSPECTION.
8) SHEET A2,2 BASEMENT LEVEL PLAN, STORAGE OO1 IS NOT APPROVED FOR FUTURE HABITABLE
LIVING SPACE. SUBJECT STORAGE SPACE CONTAINS NO NATURAL LIGHT AND VENTILATION AND
NO EMERGENCY ESCAPE OPENING, MUST NOT BE USED FOR FUTURE BEDROOM.
9) cARFIELD COUNTY ADOPTED BUILDING RESOLUTION DEFINES WET BAR: AN AREA OF A ROOM
THAT IS DESIGNED TO BE USED FOR SERVING OF BEVERAGES, THAT MAY ONLY HAVE A SINGLE BAR
SINK AND NO STANDARD SIZE KITCHEN APPLIANCES SUCH AS A STOVE, OVEN, DISHWASHER OR
FULL SIZE REFRIGERATOR. COUNTER SPACE IS LIMITED TO 25 SOUARE FEET. SEE STAMPS ON AO.O
AND 42.2 FOR REFERENCE.
10) BLOWER DOOR TEST tS REOU|RED. MUST SUBMTT BLOWER DOOR TEST REPORT TO GARFIELD
COUNTY COMMUNIry DEVELOPMENT DEPT. OFFICE PRIOR TO SCHEDULING FINAL BUILDING
INSPECTION i C.O. FINAL.
1 1) PRESCR|pTtVE PATH USING 2018 rECC TABLE R402.1.2 HAS BEEN CHOSEN FOR ENERGY
COMPLIANCE OF THIS HOME DESIGN. MANUAL J REPORT ALSO ATTACHED FOR REFERENCE.
ALL NEW HOMES TO HAVE WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM INSTALLED (2015
IRC TABLE m1507.3.3(1)AND (2) SHOWN ON COVER SHEET'