HomeMy WebLinkAboutOWTS Permit Card  Garfield County Public Health  2014 Blake Ave.   Glenwood Springs, CO 81601  Phone: (970) 945‐6614 ext. 8150  For inspections, call: 970‐945‐6614 ext. 8150 and call the Design Engineer, if applicable   Project Address: 359 East Vista Drive, Silt, CO 81652  Parcel No.: _217903100015  Owner Name: Mario Santana via Noemi Ramirez    Owner Phone: (970) 404‐7744  Designed By: High Country Engineering, Inc.    Designer Phone: (970) 945‐8876  Number of Bedrooms: _2_ Minimum Tank Capacity: 1,000‐gallon Minimum Absorption: 420 ft2  OWTS PERMIT   KEEP AVAILABLE AT PROJECT SITE   Permit Number _SEPT‐8604_______________________________  Permit Type X New X Repair X Remodel/addition X Tank only   Issue Date _04/15/2024____________________ Expiration Date_04/15/2025_________________   Permit Conditions:   This OWTS Permit is approved on the condition of compliance with the report and design as  submitted by High Country Engineering, Inc. dated April 4, 2024. Changes to the design and permit  must be approved by Garfield County Public Health and the designer prior to construction.     The new OWTS will serve an existing two‐bedroom residence and replace the existing OWTS on the  property. The system will consist of an existing two‐compartment 1,250‐gallon septic tank. An  influent and effluent tee will be installed with an effluent filter in the outlet tee of the tank. Effluent  will gravity flow to a distribution box that will distribute effluent to 432 ft2 of STA. The distribution  box will be installed level with access to grade. The new STA will consist of four gravelless chamber  trenches, each trench consisting of 9 Quick4 chambers per trench (36 Quick4 chambers total).  Inspection ports are to be installed at each end of each trench.  Maintain all setbacks and elevations  as designed.    Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final  inspection of the installed system prior to backfill. NO OWTS COMPONENT SHALL BE BACKFILLED  WITHOUT PRIOR APPROVAL FROM GARFIELD COUNTY PUBLIC HEALTH AND THE DESIGNER.          Agreement   All installations must comply with all requirements of the Garfield County OWTS regulations  including but not limited to the conditions specified above.   In consideration of the issuance of the permit, the applicant hereby agrees to comply with all  laws and regulations related to the zoning, location, construction, and erection of the proposed  OWTS and associated structures for which this permit is granted. The applicant further agrees  that if the above said regulations are not fully complied with in the zoning, location, erection,  and construction of the above described OWTS and structure, the permit may then be revoked  by notice from the Health Department and immediately become null and void.  The issuance of a permit and specifications of terms and conditions therein will not constitute  assumption of liability, nor create presumption that the local public health agency or its  employees may be liable for the failure or malfunctioning of any system. Permit issuance will  not constitute a certification that the system, the equipment used in the system, or any  component used for system operation will ensure continuous compliance with the provision of  the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.   Permit Approval  Plans and specifications for the proposed OWTS have been reviewed and are considered  satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated  in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from  the date of issuance unless construction on the system has commenced. An "as‐built" drawing  must be submitted and inspection of the system must be completed by GCPH before final  approval of the system will be issued.        04/15/2024  Issued By: Garfield County Environmental Health  Department  Date