HomeMy WebLinkAboutRes Check ReportA*err; ? +at
Generated by RES check-Web Software
Com pl ia nce Certificate
Project 751 County Road 227
Energy Code:
Location:
Construction Type:
Project Type:
Climate Zone:
Permit Date:
Permit Number:
All Electric
ls Renewable
Has Charger
Has Battery:
Has Heat Pump:
2018 IECC
Rifle, Colorado
Single-family
Addition
s (6881 HDD)
false
false
false
false
false
Compliance; 38.O7o Better Than Code Maximum UA: 366 Your Uk 227
The 7o Better or Worse Than Code lndex reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade
assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements.
Envelooe Assemblies
Construction Site:
75L CR227
Rifle, CO 8L650
Ceiling: Steel Joist/Rafter, 24in. o.c.
Wall: Wood Frame, 16" o.c.
Door: Solid Door (under 50olo glazing)
Window 1: Vinyl Frame
Window: Vinyl Frame
Floor: All-Wood Joist/Truss
Owner/Agent:
Francisco Serna
High Country Group
Po box 2003
Eagle, Co 81632
970-987-4256
mark@hi ghcountrybui ldersofco.co
m
Designer/Contractor:
Mark Stieber
High Country Builders
PO BOX 1"107
Eagle, CO 81631
970-987-4256
mark@hi g hcountrybui ldersofco.co
m
2,400
1,900
80
215
2L4
2,100
0.026
0.060
0.300
0.300
0.300
0.033
49.0
27.0
49.0
27.O
0.0r.0
0.020
0.260
0.280
0.280
0.01_6
62
83
24
64
64
69
24
28
2L
60
60
34
mpliance: Passes using UA trade-off
Cavity
R-Value
Cont.
R-Value
Prop. Req.
U-Factor U-Factor
Prop
UA
Req'
UA
Gross Area
Perimeter
orAssembly
30.0 30.0
Project Title: T5L County Road 227
Data filename:
Report date: 04108124
Page 1 of10
compliance statement: The proposed building design described.here is consistent with the building plans, specifications, and other
calculations submitted with the permit uppficalion. fne proposeC building has been d,esigned to me-et the 20L8 IECC re-quirements in
REScheck version r REScheck-web and to .bmprv *itn the ininoatory re[uirements listed in the REscheck lnspection checklist.
Signature DateName - Title
Project Title: 751 CountY Road 227
Data filename:
Report date: O4l0gl24
Page 2 of10
REScheck Software Version : REScheck-Web
lnspection Checklist
Energy Code: 2018 IECC
Requirements: 37.0olo were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Additional Comments/Assumptions:
1 High lmpact (Tier 1)2 Medium lmpact (Tier 2)3 Low lmpact (Tier 3)
Plans Verlfied
Value
Fleld Verlfied
Value Complles?Comments/Assumptlons
Sectlon
#
& Req,lD
Pre-lnspectlon/Plan Revlew
103.1,
LO3.2
lPRlll
u'
Construction drawings and
documentation demonstrate
energy code compliance for the
building envelope. Thermal
envelope represented on
construction documents.
ElComplies
DDoes Not
f]Not Observable
[lNot Applicable
:Requirement will be met.
Location on plans/spec:
Cover Page
Construction drawings and
documentation demonstrate
bnergy code compliance for
lighting and mechanical systems.
Systems serving multiple
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
103.1,
103.2,
403.7
lPR3l1
*!)
ElComplies
lDoes Not
INot Observable
[ruot applicable
Heating and cooling equipment
sized per ACCA Manual S based
on loads calculated per ACCA
Manual J or other methods
approved by the code official.
Heating:Btu/hr_
Cooling:Btu/hr_
:nComplies
lDoes Not
.DNot Observable
iDNot Applicable
302.1,
403.7
lPR2l2
iJ
is Heating:
Btu/hr
Cooling:
Btu/hr
Project Title: 751 County Road227
Data filename:
Report date: 04108124
Page 3 of10
Compllcs?Comments/AssumptlonsSectlon
#
& Reo.lD
Foundatlon lnspectlon
Snow- and ice-melting system controls
installed.
es
Not
9
iltrtot observabte I
;flruot
lFo12l2
€i
303.2.rlFollr
,s
A protective covering is installed to
protect exposed exterior insulation
and extends a minimum of 6 in. below
grade.
es lException: Requirement is not applicable.
iDooes ttot
iENot observable
;Itrtot icable
Additional Com ments/Assum ptions:
1 High lmpact (Tier 1)2 Medium lmpact (Tier 2)3 Low lmpact (Tier 3)
'Project Title: 751 County Road 227
Data filename:
Report date: O4lOBl24
Page 4 of10
4O2.L.1, . Door U-factor
402.3.4 :
U-U-
flDoes Not
:DNot Observable
;flNot Applicable :
plies See the Envelope Assemblles
table for values.
I
Comments/AssumPtlonsFleld Verlfled
Value Complles?Plans Verlfled
Value
Sectlon
#
& Req.lD
Framlng / Rough-ln lnspectlon
402.3.3,
402.5
lFR2l1
s,,
[Does Not
flNot Observable
nNot Applicable
U-U-rea-weighted '.table for values.
see the EnveloPe Assemblies
.L,average)
plies1.1, Glazing U-factor (a
303.1.3
lFR4l1
,liz
U-factors of fenestration products'
are determined in accordance
:with the NFRC test Procedure or
:taken from the default table.
flDoes Not
DNot observabre !::fiHl""Jr:ranespec:
LlNot Applicable
Req uirement will be met.
402.4.1.r
lFR23l1
g)
,Air barrier and thermal barrier
installed per manufacturer's
instructions.
Requirement will be met.
Location on plans/sPec:
Cover Page, Page A3 and see
otNnDoes
ObservableNot
eflttotApplicabl lnsulators sheet.
es
:Fenestration that is not site built
is listed and labeled as meeting
AAMA n/r/D MA/CSA 10L lt.S.2 | A44O
or has infiltration rates Per NFRC
:400 that do not exceed code
limits.
lDoes Not
[]Not Observable
,DNot npplicable
402.4.3
tFR20l1
*))
ies , Requirement will be met
lC-rated recessed lighting fixtures
sealed at housing/interior finish
and labeled to indicate <2.0 cfm
leakage at 75 Pa.
EDoes Not
'[Not Observable
INot Applicable
Requirement will be met.
Location on plans/sPec:
See attached Halo fixture
lFR16l2
.5 tes
sheet.
Supply and return ducts in attics
insulated >: R-8 where duct is
>= 3 inches In diameter and >:
R-6 where < 3 inches. SuPPIY and
return ducts in other Portions of
the building insulated >= R-6 for
diameter >= 3 inches and R-4.2
for < 3 inches in diameter
403.3.1-
lFR12l1
14,
lDoes Not
flNot Observable
[Not Applicable
boxes are sealed with
joints/seams comPliant with
lnternational Mechanical Code or
lnternational Residential Code, as
lDoes Not
[Not Observable i
lNot Applicable
, Ducts,air handlers and filter
icable.
plies403.3.2
lFR13l1
ll)
EDoes Not
flNot Observable
nNot Applicable
e53.5 Building cavities are not used as
, ducts or plenums.lFRL5l3
9.'
I High lmpact (Tier L)2 Medium lmpact (Tier 2)3 Low lmpact (Tier 3)
Project Title: 751 CountY Road 227
Data filename:
Report date: O4lABl24
Page 5 of10
Complles?Comments/Assumptlons
Sectlon
#
& Reo.lD
Framlng / Rough-ln lnspectlon Plans Verlfled
Value
Fleld Verlfled
Value
403.4
lFR1712
t,
HVAC piping conveying fluids
above l-05 sF or chilled fluids
below 55 oF are insulated to =R-3.
tDComplies
lDDoes Not
i[ltot observable
;[ruot applicable
R-R-
403.4.1
lFR24l1
'Sr
DComplies
[Does Not
ilNot Observable
nNot Applicable
Protection of insulation on HVAC
piping.
403.3.7
IFR2813
v;
Ducts declared to be within the
, conditioned space are either 1)
lcompletely within the continuous
air barrier and within the building
thermal envelope, 2) buried
within ceiling insulation in
accordance with Section
:R403.3.6 and the air handler is
,located completely within the
'continuous air barrier and within
the building thermal envelope
and the duct leakage is <: 1.5
cfm / 100 square feet of
conditioned floor area served by
the duct system, or 3) the ceiling
insulation R-value installed
,against and above the insulated
duct >: to the proposed ceiling
insulation R-value, less the R-
:value of the insulation on the
Hot water pipes are insulated to
>R-3.
Automatic or gravity dampers are
installed on all outdoor air
intakes and exhausts.
tes
DDoes Not
DNot Observable
lNot Applicable
[Complies
EDoes Not
rnNot observable
lDNot Applicable
res
DDoes Not
nNot Observable
flt'tot
tRequirement will be met
403.5.3
lFRL8l2
I
403.6
lFR1912
R-R-
Additional Comments/Assumptions:
Medium I (Tier 2)3 Low lmpact (Tier 3)1 High lmpact (Tier 1)2
Project Title: 751 County Road227
Data filename:
Report date: 04logl24
Page 6 of10
All installed insulation is labeled
or the installed R-values
provided.
Requirement will be met.303.1
lrNl3]2
,g
Not
DNot Observable
flttot cable
Complles?Comments/AssumPtlonsFleld Verlfled
Value
Plans Verlfled
Value
Sectlon
#
& Reo.lD
lnsulation lnspectlon
402.1.1. Floorinsulation R-value.
4A2.2.6
ltN1l1
rs,,
I R-_
;I Wood
n steet
lUooes Not
,!lrtot Observable
iENot npplicable
plies ;See the Envelope Assemblies
"table
for values.R-_
fl wood
fl Steel
manufacturer's instructions and
in substantial contact with the
underside of the subfloor, or floor
framing cavity insulation is in
contact with the toP side of
, sheathing, or continuous
, insulation is installed on the
;underside of floor framing and
extends from the bottom to the
top of all perimeter floor framing
members.
EDoes Not
--. . ^. Location on Plans/sPec:LJNot observable :Cover page & page 43
flNot Applicable
rFloor insulation installed Per303.2,
402.2.8
ltN2l1
I
ies Requirement will be met.
402.L.L,
402,2.5,
402.2.6
IlN3l1
s,,
, R-_
:n wooolD Mass
; I Steel
, Wall insulation R-value.
mass wall with at least
lf this is a ; R--
% of the I fl WooO ilDoes Not
les See the Enveloqe Assemblies
table for values.
[Not observable I
[JNot Applicable
wall insulation on the wall
exterior, the exterior insulation
requirement aPPlies (FRl0).
lff Mass
I Steel
,DDoes Not
,flNot Observable ;
DNot Applicable l
plans/spec:
Page 43
Requirement will be met'
Wall insulation is installed Per
manufacturer's instructions.
303.2
llN4ll Location on
Cover Page &
Additional Comments/Assumptions:
1 High lmpact (Tier 1)2 Medium lmpact (Tier 2 )3 Low lmpact (Tier 3)
Project Title: 751 CountY Road 227
Data filename:
Report date: O4lO8l24
Page 7 ofL0
402.L.L, Ceiling insulation R-value.
402.2.L,
402.2.2,
402.2.6
lFrll1
R-_:a wood
I Steel
R-_
I Wood
I Steel
res
,lDoes Not
nNot Observable
;fltrtot Applicable
[Does ttlot
flNot Observable
:nNot Applicable
See fhe Envelope Assemblies
table for values.
403.3.3
lFt2711
Ducts are pressure tested to
determine air leakage with
either: Rough-in test: Total
leakage measured with a
pressure differential of 0.1 inch
w.g. across the sYstem including
the manufacturer's air handler
enclosure if installed at time of
test. Postconstruction test: Total
leakage measured with a
pressure differential of 0.1 inch
w.g. across the entire system
including the manufacturer's air
handler enclosure.
cfm/100 cfm/100@-ftu--
I High lmpact (Tier 1)2 Medium lmpact (Tier 2)3 Low Impact (Tier 3)
Complles?Comments/AssumptlonsFleld Verlfled
Value
Plans Verlfled
Value
Sectlon
#
& Req,lD
Final lnspectlon Provlsions
303.1.1.1, Ceiling insulation installed per
303.2 manufacturer's instructions.
lFl2ll Blown insulation marked every
300 ftr.
ilDoes Not
flNot observable
INot Applicable
Requirement will be met.res
Location on plans/spec:
Cover Page & Page 43
Vented attics with air Permeable
insulation include baffle adjacent
to soffit and eave vents that
extends over insulation.
Not
ies Exception; Requirement is
not applicable.402.2.3
IFt22l2
ilNot Observable
nNot Applicable
Location on plans/sPec:
Vaulted ceilings with HYbrid
spray foam R49 4.5" Foam
with R L9 Batt
R-R-_
Not
Requirement will be met.402.2.4
lFl3l1
Attic access hatch and door
insulation >R-value of the
adjacent assembly.flNot Observable
DNot applicable
Blower door test @ 50 Pa. <=5 : ACH 50 =-
ach in Climate Zones 1-2, and
<=3 ach in Climate Zones 3-8.
Requirement will be met.
Location on plans/sPec:
Minisplit system
ACH 50 =402.4.L.2
lFr17l1
:[Not Observable
!Not Applicable
flcomplies
nDoes Not
Duct tightness test result of <=4
cfm/100 ft2 across the system or
<:3 cfm/100 ft2 without air
handler @ 25 Pa. For rough-in
tests, verification may need to
lDoes Not
:DNot observable:lNot Applicable
cfm/100cfm/100
ft2
occur du Framin lnspection
ft2
403.3.4
lF14l1
Air handler leakage designated
by manufacturer al <:2o/o of
design air flow.
flDoes Not
flNot observable
ENot applicable
403.3.2.L
lFr24l1
Programmable thermostats
installed for control of PrimarY
heating and cooling systems and
initially set by manufacturer to
code specifications.
lComplies
lDoes Not
flNot observable
DNot Rpplicable
403.1.1
lFl912
nDoes Not
flNot Observable
[Not Applicable
res403.L.2
lFr1012
Heat pump thermostat installed
on heat pumps.
Project Title: T5L CountY Road 227
Data filename:
Report date: O4logl24
Page 8 of10
Plans Verlfled
Value
Fleld Verlfled
Value Complles?Comments/Assumptlons
Section
#
& Req.lD
Flnal lnspectlon Provlslons
All mechanical ventilation system
fans not part of tested and listed
HVAC equipment meet efficacy
and air flow limits per Table
R403.6.1.
flComplies
lEDoes Not
DNot Observable
DNot Applicable
403.6.1
lFt2512
Hot water boilers supplying heat
through one- or two-pipe heating
systems have outdoor setback
control to lower boiler water
temperature based on outdoor
temperature.
flComplies
EDoes Not
tnNot Observable
DNot Applicable
403.2
lFl26l2
Heated water circulation systems
have a circulation pump. The
system return pipe is a dedicated
return pipe or a cold water supply'
pipe. Gravity and thermos-
syphon circulation systems are
not present. Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
occupancy. Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
N ot
tes403.5.1.1
lFr28l2
nNot Observable
DNot Applicable
Demand recirculation water
systems have controls that
manage operation of the pump
and limit the temperature of the
water entering the cold water
lDoes Not
[Not Observable
DNot Applicable
res
to <= 104eF
4A3.5.2
lFt3012
Drain water heat recovery units
tested in accordance with CSA
855.1. Potable water-side
pressure loss of drain water heat
. recovery units < 3 psi for
individual units connected to one
or two showers. Potable water-
;side pressure loss of drain water
heat recovery units < 2 psi for
individual units connected to
three or more showers.
403.5.4
lFt3u2
DNot Observable
[Not Applicable ,
9oo/o or more of permanent
fixtures have high efficacy lamps.
[lComplies
[Does Not
.lttot Observable
'Ittot applicable
404.L
lF16l1
404.1.1
lFr23l3
u
[Complies
.[Does Not
[Not observable
ENot Applicable
:Fuel gas lighting systems have
ino continuous pilot light.
403.5.1
lFrL112
Circulating service hot water
systems have automatic or
accessible manual controls.
Electric heat trace systems
comply with IEEE 515.1 or UL
515. Controls automatically
adjust the energy input to the
heat tracing to maintain the
desired water temperature in the
piping.
plies
lDoes Not
DNot Observable
[1Not Applicable
:DComplies
[Does Not
INot Observable
rflNot Applicable
403.5.1.2
lFr29l2
1 (Tier 1)H 2 Medium lmpact (Tier 2)3 (Tier 3)Low
Project Title: 751 County Road 227
Data filename:
Report date: O4logl24
Page 9 of10
Complles?Commentc/A3sumptlongFleld Verlflcd
Valua
Plans Verlfled
Value
Sectlon
#
& Reo,lD
Flnal lnspectlon Provlslone
Manufacturer manuals for
mechanical and water heating
systems have been provided.
303.3
Druot cable
;[Does Not
lIttot Observable
40L.3
lFt712
Compliance certificate posted.
Additional Comments/Assum ptions:
Requirement will be met.
:flNot
lEwot
Not
Observable
Applicable
L High lmpact (Tier 1)z Medium lmpact (Tier 2)3 Low lmpact {Tier 3)
Project Title: 751 County Road 227
Data filename:
Report date: O4lO8l24
Page 10 of10
2018 IECC Energy
Efficiency Certificate
Above-Grade Wall
Below-Grade Wall
Floor
Ceiling / Roof
Ducturork (unconditioned spaces) :
Window
Door
Heating System:
Cooling System:_
Water
Name:
lomments
54.OO
o.oo
60.oo
98.OO
o.28
o.26
Date:
lnsulation Rating R-Value
Glass & Door Rating U-Factor SHGC
Heating & Cooling Equipment Efficiency