HomeMy WebLinkAboutRes Check ReportA*err; ? +at Generated by RES check-Web Software Com pl ia nce Certificate Project 751 County Road 227 Energy Code: Location: Construction Type: Project Type: Climate Zone: Permit Date: Permit Number: All Electric ls Renewable Has Charger Has Battery: Has Heat Pump: 2018 IECC Rifle, Colorado Single-family Addition s (6881 HDD) false false false false false Compliance; 38.O7o Better Than Code Maximum UA: 366 Your Uk 227 The 7o Better or Worse Than Code lndex reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements. Envelooe Assemblies Construction Site: 75L CR227 Rifle, CO 8L650 Ceiling: Steel Joist/Rafter, 24in. o.c. Wall: Wood Frame, 16" o.c. Door: Solid Door (under 50olo glazing) Window 1: Vinyl Frame Window: Vinyl Frame Floor: All-Wood Joist/Truss Owner/Agent: Francisco Serna High Country Group Po box 2003 Eagle, Co 81632 970-987-4256 mark@hi ghcountrybui ldersofco.co m Designer/Contractor: Mark Stieber High Country Builders PO BOX 1"107 Eagle, CO 81631 970-987-4256 mark@hi g hcountrybui ldersofco.co m 2,400 1,900 80 215 2L4 2,100 0.026 0.060 0.300 0.300 0.300 0.033 49.0 27.0 49.0 27.O 0.0r.0 0.020 0.260 0.280 0.280 0.01_6 62 83 24 64 64 69 24 28 2L 60 60 34 mpliance: Passes using UA trade-off Cavity R-Value Cont. R-Value Prop. Req. U-Factor U-Factor Prop UA Req' UA Gross Area Perimeter orAssembly 30.0 30.0 Project Title: T5L County Road 227 Data filename: Report date: 04108124 Page 1 of10 compliance statement: The proposed building design described.here is consistent with the building plans, specifications, and other calculations submitted with the permit uppficalion. fne proposeC building has been d,esigned to me-et the 20L8 IECC re-quirements in REScheck version r REScheck-web and to .bmprv *itn the ininoatory re[uirements listed in the REscheck lnspection checklist. Signature DateName - Title Project Title: 751 CountY Road 227 Data filename: Report date: O4l0gl24 Page 2 of10 REScheck Software Version : REScheck-Web lnspection Checklist Energy Code: 2018 IECC Requirements: 37.0olo were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Additional Comments/Assumptions: 1 High lmpact (Tier 1)2 Medium lmpact (Tier 2)3 Low lmpact (Tier 3) Plans Verlfied Value Fleld Verlfied Value Complles?Comments/Assumptlons Sectlon # & Req,lD Pre-lnspectlon/Plan Revlew 103.1, LO3.2 lPRlll u' Construction drawings and documentation demonstrate energy code compliance for the building envelope. Thermal envelope represented on construction documents. ElComplies DDoes Not f]Not Observable [lNot Applicable :Requirement will be met. Location on plans/spec: Cover Page Construction drawings and documentation demonstrate bnergy code compliance for lighting and mechanical systems. Systems serving multiple dwelling units must demonstrate compliance with the IECC Commercial Provisions. 103.1, 103.2, 403.7 lPR3l1 *!) ElComplies lDoes Not INot Observable [ruot applicable Heating and cooling equipment sized per ACCA Manual S based on loads calculated per ACCA Manual J or other methods approved by the code official. Heating:Btu/hr_ Cooling:Btu/hr_ :nComplies lDoes Not .DNot Observable iDNot Applicable 302.1, 403.7 lPR2l2 iJ is Heating: Btu/hr Cooling: Btu/hr Project Title: 751 County Road227 Data filename: Report date: 04108124 Page 3 of10 Compllcs?Comments/AssumptlonsSectlon # & Reo.lD Foundatlon lnspectlon Snow- and ice-melting system controls installed. es Not 9 iltrtot observabte I ;flruot lFo12l2 €i 303.2.rlFollr ,s A protective covering is installed to protect exposed exterior insulation and extends a minimum of 6 in. below grade. es lException: Requirement is not applicable. iDooes ttot iENot observable ;Itrtot icable Additional Com ments/Assum ptions: 1 High lmpact (Tier 1)2 Medium lmpact (Tier 2)3 Low lmpact (Tier 3) 'Project Title: 751 County Road 227 Data filename: Report date: O4lOBl24 Page 4 of10 4O2.L.1, . Door U-factor 402.3.4 : U-U- flDoes Not :DNot Observable ;flNot Applicable : plies See the Envelope Assemblles table for values. I Comments/AssumPtlonsFleld Verlfled Value Complles?Plans Verlfled Value Sectlon # & Req.lD Framlng / Rough-ln lnspectlon 402.3.3, 402.5 lFR2l1 s,, [Does Not flNot Observable nNot Applicable U-U-rea-weighted '.table for values. see the EnveloPe Assemblies .L,average) plies1.1, Glazing U-factor (a 303.1.3 lFR4l1 ,liz U-factors of fenestration products' are determined in accordance :with the NFRC test Procedure or :taken from the default table. flDoes Not DNot observabre !::fiHl""Jr:ranespec: LlNot Applicable Req uirement will be met. 402.4.1.r lFR23l1 g) ,Air barrier and thermal barrier installed per manufacturer's instructions. Requirement will be met. Location on plans/sPec: Cover Page, Page A3 and see otNnDoes ObservableNot eflttotApplicabl lnsulators sheet. es :Fenestration that is not site built is listed and labeled as meeting AAMA n/r/D MA/CSA 10L lt.S.2 | A44O or has infiltration rates Per NFRC :400 that do not exceed code limits. lDoes Not []Not Observable ,DNot npplicable 402.4.3 tFR20l1 *)) ies , Requirement will be met lC-rated recessed lighting fixtures sealed at housing/interior finish and labeled to indicate <2.0 cfm leakage at 75 Pa. EDoes Not '[Not Observable INot Applicable Requirement will be met. Location on plans/sPec: See attached Halo fixture lFR16l2 .5 tes sheet. Supply and return ducts in attics insulated >: R-8 where duct is >= 3 inches In diameter and >: R-6 where < 3 inches. SuPPIY and return ducts in other Portions of the building insulated >= R-6 for diameter >= 3 inches and R-4.2 for < 3 inches in diameter 403.3.1- lFR12l1 14, lDoes Not flNot Observable [Not Applicable boxes are sealed with joints/seams comPliant with lnternational Mechanical Code or lnternational Residential Code, as lDoes Not [Not Observable i lNot Applicable , Ducts,air handlers and filter icable. plies403.3.2 lFR13l1 ll) EDoes Not flNot Observable nNot Applicable e53.5 Building cavities are not used as , ducts or plenums.lFRL5l3 9.' I High lmpact (Tier L)2 Medium lmpact (Tier 2)3 Low lmpact (Tier 3) Project Title: 751 CountY Road 227 Data filename: Report date: O4lABl24 Page 5 of10 Complles?Comments/Assumptlons Sectlon # & Reo.lD Framlng / Rough-ln lnspectlon Plans Verlfled Value Fleld Verlfled Value 403.4 lFR1712 t, HVAC piping conveying fluids above l-05 sF or chilled fluids below 55 oF are insulated to =R-3. tDComplies lDDoes Not i[ltot observable ;[ruot applicable R-R- 403.4.1 lFR24l1 'Sr DComplies [Does Not ilNot Observable nNot Applicable Protection of insulation on HVAC piping. 403.3.7 IFR2813 v; Ducts declared to be within the , conditioned space are either 1) lcompletely within the continuous air barrier and within the building thermal envelope, 2) buried within ceiling insulation in accordance with Section :R403.3.6 and the air handler is ,located completely within the 'continuous air barrier and within the building thermal envelope and the duct leakage is <: 1.5 cfm / 100 square feet of conditioned floor area served by the duct system, or 3) the ceiling insulation R-value installed ,against and above the insulated duct >: to the proposed ceiling insulation R-value, less the R- :value of the insulation on the Hot water pipes are insulated to >R-3. Automatic or gravity dampers are installed on all outdoor air intakes and exhausts. tes DDoes Not DNot Observable lNot Applicable [Complies EDoes Not rnNot observable lDNot Applicable res DDoes Not nNot Observable flt'tot tRequirement will be met 403.5.3 lFRL8l2 I 403.6 lFR1912 R-R- Additional Comments/Assumptions: Medium I (Tier 2)3 Low lmpact (Tier 3)1 High lmpact (Tier 1)2 Project Title: 751 County Road227 Data filename: Report date: 04logl24 Page 6 of10 All installed insulation is labeled or the installed R-values provided. Requirement will be met.303.1 lrNl3]2 ,g Not DNot Observable flttot cable Complles?Comments/AssumPtlonsFleld Verlfled Value Plans Verlfled Value Sectlon # & Reo.lD lnsulation lnspectlon 402.1.1. Floorinsulation R-value. 4A2.2.6 ltN1l1 rs,, I R-_ ;I Wood n steet lUooes Not ,!lrtot Observable iENot npplicable plies ;See the Envelope Assemblies "table for values.R-_ fl wood fl Steel manufacturer's instructions and in substantial contact with the underside of the subfloor, or floor framing cavity insulation is in contact with the toP side of , sheathing, or continuous , insulation is installed on the ;underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. EDoes Not --. . ^. Location on Plans/sPec:LJNot observable :Cover page & page 43 flNot Applicable rFloor insulation installed Per303.2, 402.2.8 ltN2l1 I ies Requirement will be met. 402.L.L, 402,2.5, 402.2.6 IlN3l1 s,, , R-_ :n wooolD Mass ; I Steel , Wall insulation R-value. mass wall with at least lf this is a ; R-- % of the I fl WooO ilDoes Not les See the Enveloqe Assemblies table for values. [Not observable I [JNot Applicable wall insulation on the wall exterior, the exterior insulation requirement aPPlies (FRl0). lff Mass I Steel ,DDoes Not ,flNot Observable ; DNot Applicable l plans/spec: Page 43 Requirement will be met' Wall insulation is installed Per manufacturer's instructions. 303.2 llN4ll Location on Cover Page & Additional Comments/Assumptions: 1 High lmpact (Tier 1)2 Medium lmpact (Tier 2 )3 Low lmpact (Tier 3) Project Title: 751 CountY Road 227 Data filename: Report date: O4lO8l24 Page 7 ofL0 402.L.L, Ceiling insulation R-value. 402.2.L, 402.2.2, 402.2.6 lFrll1 R-_:a wood I Steel R-_ I Wood I Steel res ,lDoes Not nNot Observable ;fltrtot Applicable [Does ttlot flNot Observable :nNot Applicable See fhe Envelope Assemblies table for values. 403.3.3 lFt2711 Ducts are pressure tested to determine air leakage with either: Rough-in test: Total leakage measured with a pressure differential of 0.1 inch w.g. across the sYstem including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test: Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. cfm/100 cfm/100@-ftu-- I High lmpact (Tier 1)2 Medium lmpact (Tier 2)3 Low Impact (Tier 3) Complles?Comments/AssumptlonsFleld Verlfled Value Plans Verlfled Value Sectlon # & Req,lD Final lnspectlon Provlsions 303.1.1.1, Ceiling insulation installed per 303.2 manufacturer's instructions. lFl2ll Blown insulation marked every 300 ftr. ilDoes Not flNot observable INot Applicable Requirement will be met.res Location on plans/spec: Cover Page & Page 43 Vented attics with air Permeable insulation include baffle adjacent to soffit and eave vents that extends over insulation. Not ies Exception; Requirement is not applicable.402.2.3 IFt22l2 ilNot Observable nNot Applicable Location on plans/sPec: Vaulted ceilings with HYbrid spray foam R49 4.5" Foam with R L9 Batt R-R-_ Not Requirement will be met.402.2.4 lFl3l1 Attic access hatch and door insulation >R-value of the adjacent assembly.flNot Observable DNot applicable Blower door test @ 50 Pa. <=5 : ACH 50 =- ach in Climate Zones 1-2, and <=3 ach in Climate Zones 3-8. Requirement will be met. Location on plans/sPec: Minisplit system ACH 50 =402.4.L.2 lFr17l1 :[Not Observable !Not Applicable flcomplies nDoes Not Duct tightness test result of <=4 cfm/100 ft2 across the system or <:3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in tests, verification may need to lDoes Not :DNot observable:lNot Applicable cfm/100cfm/100 ft2 occur du Framin lnspection ft2 403.3.4 lF14l1 Air handler leakage designated by manufacturer al <:2o/o of design air flow. flDoes Not flNot observable ENot applicable 403.3.2.L lFr24l1 Programmable thermostats installed for control of PrimarY heating and cooling systems and initially set by manufacturer to code specifications. lComplies lDoes Not flNot observable DNot Rpplicable 403.1.1 lFl912 nDoes Not flNot Observable [Not Applicable res403.L.2 lFr1012 Heat pump thermostat installed on heat pumps. Project Title: T5L CountY Road 227 Data filename: Report date: O4logl24 Page 8 of10 Plans Verlfled Value Fleld Verlfled Value Complles?Comments/Assumptlons Section # & Req.lD Flnal lnspectlon Provlslons All mechanical ventilation system fans not part of tested and listed HVAC equipment meet efficacy and air flow limits per Table R403.6.1. flComplies lEDoes Not DNot Observable DNot Applicable 403.6.1 lFt2512 Hot water boilers supplying heat through one- or two-pipe heating systems have outdoor setback control to lower boiler water temperature based on outdoor temperature. flComplies EDoes Not tnNot Observable DNot Applicable 403.2 lFl26l2 Heated water circulation systems have a circulation pump. The system return pipe is a dedicated return pipe or a cold water supply' pipe. Gravity and thermos- syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. N ot tes403.5.1.1 lFr28l2 nNot Observable DNot Applicable Demand recirculation water systems have controls that manage operation of the pump and limit the temperature of the water entering the cold water lDoes Not [Not Observable DNot Applicable res to <= 104eF 4A3.5.2 lFt3012 Drain water heat recovery units tested in accordance with CSA 855.1. Potable water-side pressure loss of drain water heat . recovery units < 3 psi for individual units connected to one or two showers. Potable water- ;side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. 403.5.4 lFt3u2 DNot Observable [Not Applicable , 9oo/o or more of permanent fixtures have high efficacy lamps. [lComplies [Does Not .lttot Observable 'Ittot applicable 404.L lF16l1 404.1.1 lFr23l3 u [Complies .[Does Not [Not observable ENot Applicable :Fuel gas lighting systems have ino continuous pilot light. 403.5.1 lFrL112 Circulating service hot water systems have automatic or accessible manual controls. Electric heat trace systems comply with IEEE 515.1 or UL 515. Controls automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping. plies lDoes Not DNot Observable [1Not Applicable :DComplies [Does Not INot Observable rflNot Applicable 403.5.1.2 lFr29l2 1 (Tier 1)H 2 Medium lmpact (Tier 2)3 (Tier 3)Low Project Title: 751 County Road 227 Data filename: Report date: O4logl24 Page 9 of10 Complles?Commentc/A3sumptlongFleld Verlflcd Valua Plans Verlfled Value Sectlon # & Reo,lD Flnal lnspectlon Provlslone Manufacturer manuals for mechanical and water heating systems have been provided. 303.3 Druot cable ;[Does Not lIttot Observable 40L.3 lFt712 Compliance certificate posted. Additional Comments/Assum ptions: Requirement will be met. :flNot lEwot Not Observable Applicable L High lmpact (Tier 1)z Medium lmpact (Tier 2)3 Low lmpact {Tier 3) Project Title: 751 County Road 227 Data filename: Report date: O4lO8l24 Page 10 of10 2018 IECC Energy Efficiency Certificate Above-Grade Wall Below-Grade Wall Floor Ceiling / Roof Ducturork (unconditioned spaces) : Window Door Heating System: Cooling System:_ Water Name: lomments 54.OO o.oo 60.oo 98.OO o.28 o.26 Date: lnsulation Rating R-Value Glass & Door Rating U-Factor SHGC Heating & Cooling Equipment Efficiency