RE: Bleecher framing items
Bruce,
The letter is to address a few items from a recent framing inspection.
- The (2)-7 ¼”LVL Header at the entry was designed to be a single span, and the center
column on the permit set is not required.
- The shearwalls have been designed to be where shown on the plans. The shearwall
sheathing above and below door and window openings is not required.
- The 2nd level deck framing may be hung instead of bearing like the permit drawings show
them.
Please let us know if you have any further questions or need anything else.