Loading...
HomeMy WebLinkAboutMechanical Compliance ReportCOMcheck $oftware Version 4,1.5.5 Mechanical Gompl iance Gertificate ' Project lnformation Energy Code: Project Title: Location: Climate Zone: Project Type: Construction Site: 545 Bald Eagle Way Carbondale, CO 81623 2015IECC Aspen Glen Club-Fitness Center Renovation Carbondale, Colorado 5b Addition Owner/Agent: Aspen Glen Club Designer/Contractor: B&H Engineers 511 E John Carpenter Fwy Suite 250 lrving, TX 75062 (2r4) 496-7670 Mechanical Systems List Quantity System Type & Description HVAC System 1 (Single Zone): VRF Condensing Unit, Air Cooled Heat Pump Heating Mode: Capacity = 58 kBtuih, No minimum efficiency requirement applies Cooling Mode: Capacity = 72kBlulh, No minimum efficiency requirement applies Fan System: None HVAC System 2 (Single Zone): Cooling:1 each -VRFZone Fan Unit, Capacity= 12 kBtu/h, No Economizer, Economizerexception: None No minimum efficiency requirement applies Fan System: FAN SYSTEM 1 | FCU-1 , FCU-2, FCU-3 - Compliance (Motor nameplate HP method) : Passes Fans: FAN 1 Supply, Single-Zone VAV, 511 CFM, 0.1 motor nameplate hp, 80.0 fan efficiency grade HVAC System 3 (Single Zone): Cooling: 1 each - VRF Zone Fan Unit, Capacity = 7 kBtu/h, Unknown Economizer No minimum efficiency requirement applies Fan System: FAN SYSTEM 2IFCU-4 - Compliance (Motor nameplate HP method) : Passes Fans: FAN 2 Supply, Single-Zone VAV, 317 CFM, 0.1 motor nameplate hp, 80.0 fan efficiency grade Mechanical Gompliance Statement Compliance Statementj The proposed mechanical design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.5.5 and to comply with any applicable mandatory requirements listed in the lnspection Checklist, Nevena Parsons - Sen. Mechanical Engineer N.Parsons 101272023 me Signature Date 3 Project Title: Data filename Aspen Glen Club-Fitness Center Renovation Report date Z:\Projects\05066 - Club Corp\o5066.65 - Aspen Glen Pool & Fitness Country Club Renovations\ Page ComCheck\Phase 2\Pro Shop\ComCheck-Mechanical-Aspen Glen-Pro shop.cck L0t27 t23 lof 10 COMcfi eck Software Versicn 4,L. 5.5 Inspection Checklist Energy Code: 201-5 IECC Requirements: 0.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to thattable is provided. Additional Comments/Assumptions: Project Title: Aspen Glen Club-Fitness Center Renovation Report date: LOl27 123 Data filename: Z:\Projects\05066 - Club Corp\05066.65 - Aspen Glen Pool & Fitness Country Club Renovations\ Page 2 of I0 ComCheck\Phase 2\Pro Shop\ComCheck-Mechanical-Aspen Glen-Pro shop.cck €omplies?CommentslAssumptions Section # & Req.lD Plan Review Plans, specifications, and/or calculations provide all information with which compliance can be determined for the mechanical systems and equipment and document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and handbooks. c103.2 lPR2l1 ,nComplies :nooes Not ]ENot observable jflNot Applicable Plans, specifications, and/or calculations provide all information with which compliance can be determined for the additional energy res efficien e ons c406 lPR9l1 ;lDoes Not Not Observable Not Applicable ct (Tier 1)H h 2 Medium ct (Tier 2)3 Low lmpact (Tier 3)1 Snow/ice melting system sensors for future connection to controls. Freeze protection systems have automatic controls installed. Does Not Not Observable Not Applicable plies Add itional Comments/Assum ptions : Project Title: Aspen Glen Club-Fitness Center Renovation Report date: L0127123 Data filename: Z:\Projects\05066 - Club Corp\05066.65 - Aspen Glen Pool & Fitness Country Club Renovations\ Page 3 of 10 ComCheck\Phase 2\Pro Shop\ComCheck-Mechanical-Aspen Glen-Pro shop.cck ct (Tier 3)LowL(Tier 1)Hi Medium I (Tier 2) Comments/Assumptions Section # & Reo.lD Plumbing Rough-ln lnspection Complies? C404.5, ,Heated water supply piping conforms C4O4.5.1, .to pipe length and volume C404.5.2 :requirements. Refer to section details :nrtr ln ln Complies Does Not Not Observable Not ApplicablelPL6l3 c404.5, c404.5.1, c404.5.2 lPL6l3 ,Heated water supply plping conforms ,to pipe length and volume :requirements. Refer to section details Complies Does Not Not Observable Not Applicable tn itr c404.5, c404.5.1, c404.5.2 lPL6l3 to pipe length and volume llOoes lrlot requirements. Refer to section details. ENot Observable :ENot Applicable Heated water supply piping conforms Complies Pumps that circulate water between a heater and storage tank have controls that limit operation from startup to <= 5 minutes after end of heating Does Not mpliesc404.6.3 lPL7l3 ;ENot Observable jEruot npplicaole heater and storage that limit operation m ESUrcwaterlateabetweenPumclthatplips nta hk VCa ntrolco s Does Not,E from tostartup otN bseo btrva e:!tihea n5tnmafterutesofend s c bleaotN:!Applcycle c404.6.3 lPL7l3 'Pumps that circulate water between a , heater and storage tank have controls lljtr mplies lDoes Not cycle c404.6.3 lPL7l3 Not Observable Not Applicable ,that limit operation from startup to r<= 5 minutes after end of heating ;Water distribution system that pumps 'water from a heated-water supply : pipe back to the heated-water source ,through a cold-water supply pipe is a : demand recirculation water system. :Pumps within this system have , controls that start the pump upon ,receiving a signal from the action of a .user of a fixture or appliance and ,limits the temperature of the water entering the cold-water piping to :104'F. mpliesc404.7 lPL8l3 lDoes Not nNot Observable ENot Applicable , Water distribution system that pumps ,water from a heated-water supply : pipe back to the heated-water source ,through a cold-water supply pipe is a , demand recirculation water system. ,Pumps within this system have controls that start the pump upon :receiving a signal from the action of a :user of a fixture or appliance and limits the temperature of the water entering the cold-water piping to :104'F. mpliesc404.7 IPL8]3 EDoes Not ENot Observable ENot Applicable 31lm(Tier 1)Hi 2 Medium lmpact (Tier 2)Low I (Tier 3) Project Title: Data filename Aspen Glen Club-Fitness Center Renovation Report datei lll27 123 Z:\Projects\05066 - Club Corp\05066,65 - Aspen Glen Pool & Fitness Country Club Renovations\ Page 4 of 10 ComCheck\Phase 2\Pro Shop\ComCheck-Mechanical-Aspen Glen-Pro shop,cck Water distribution system that pumps water from a heated-water supply pipe back to the heated-water source through a cold-water supply pipe is a demand recirculation water system. Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold-water piping to l-04'F. ;tr t;tr ;tr plies Does Not Not Observable Not Applicable Additional Comments/Assumptions : Medium lm 2)(Tier 3)LowIlmpact (Tier 1)H Project Title: Data filename: Aspen Glen Club-Fitness Center Renovation Report datei IOl27l23 Z:\Projects\05066 - Club Corp\05066.65 - Aspen Glen Pool & Fitness Country Club Renovations\ Page 5 of 10 ComCheck\Phase 2\Pro Shop\ComCheck-Mechanical-Aspen Glen-Pro shop.cck Section s & Reo.lD Mechanical Rough-ln lnspectaon Complies?Cornments/Assumptions Thermally ineffective panel surfaces sensible heating panels have insulation >= R-3.5. EComplies EDoes Not ENot Observable ENot Applicable c402.2.6 lME41l3 C403.2.12 HVAC fan systems at design.l conditions do not exceed allowable [ME65]3 fan system motor nameplate hp or fan See the Mechanical Systems list for values system bhp. lDoes Not Complies lENot Observable; iEtrtot Applicable ,Fans have efficiency grade (FEG) >= ,67. The total efficiency of the fan at :the design point of operation <: l5o/o of maximum total efficiency of the , fan. c403.2.12 .3 lME1L7l2 ,tr ;l :a Complies Does Not Not Observable Not Applicable C403.2.13 Unenclosed spaces that are heated lME7l,l2 use only radiant heat. ;nir ,EComplies ,EDoes Not Not Observable Not Applicable HVAC equipment efficiency verified. :lComplies :See the Mechanicat Systems list for vatues. [Does Not ENot Observable Eruot applicable . c403.2.3 lME55l2 : Demand control ventilation provided ,for spaces >500 ft2 and >25 : people/1000 ft2 occupant density and ,served by systems with air side :economizer, auto modulating outside :air damper control, or design air"flow , >3,000 cfm. :EComplies :lDoes Not .!lVot Observable :nNot Applicable c403.2.6. 1 lME59l1 c403.2.6. 2 lME115l3 , Enclosed parking garage ventilation has automatic contaminant detection and capacity to stage or modulate fans to 5oo/o or less of design capacity nComplies EDoes Not INot observable ENot Applicable : : Exhaust air energy recovery on i systems meeting Table C403.2.7(1) :and C403.2.7(2). EComplies EDoes Not !Not Observable ENot le c403.2.7 lME57l1 Kitchen exhaust systems comply with replacement air and conditioned supply air limitations, and satisfy hood rating requirements and maximum EComplies nDoes Not !Not observable nNot Applicableexhaust rate criteria. c403.2.8 lM€11613 HVAC ducts and plenums insulated. Where ducts or plenums are installed :in or under a slab, verification may need to occur during Foundation lnspection, inNot Observable iEruot applicable EComplies lDoes Not c403.2.9 lME60l2 , Ducts and plenums sealed based on , static pressure and location. Ewot licable resc403,2.9 lME10l2 EDoes Not nNot Observable c403.2.9 1.3 tMc11l3 Ductwork operating >3 in. water column requires air leakage testing. !Complies lDoes Not nNot Observable nruot Rpplicable 1 Hi ct (Tier 1)I 2 Medium lmpact (Tier 2)3 Low lmpact (Tier 3) Project Title: Aspen Glen Club-Fitness Center Renovation Report date: 10127/23 Data filename: Z:\Projects\05066 - Club Corp\05066.65 - Aspen Glen Pool & Fitness Country Club Renovations\ Page 6 of 10 ComCheck\Phase 2\Pro Shop\ComCheck-Mechanical-Aspen Glen-Pro shop.cck CcmmentslAssumptions Section # & Reo.lD I{echanical Rough-ln lnspection Complies? c403.2.9. 1.3 lMf 1113 ,Ductwork operating >3 in. water , column requires air leakage testing Complies Does Not Not Observable Not Applicable 1tr .tr :fl :n c403.2.9- 1.3 lME11l3 ,Ductwork operating >3 in. water ,column requires air leakage testing Complies Does Not Not Observable Not Applicable 'tr isolate the cooling tower from the , heat pump loop, and heat loss is ,controlled by shutting down the :circulation pump on the cooling towe ,Open- or closed circuit cooling towers Complies , have a separate heat exchanger to Does Not lnNot Observable .nruot Rpplicable f: loo c403.4.2. 3.2.2 lMEL2213 , Multiple zone VAV systems with DDC ,of individual zone boxes have static : pressure setpoint reset controls, Complies :see the Mechanical Systems list for values Does Not : Not Observable; c403.4.4. in iltrtot Rpplicaole 6 lME11013 C403.4.4. ,Multiple zone VAV systems with DDC6 of individual zone boxes have static :tr ;tr See the Mechanical Systems list far values. pressure setpoint reset controls. Complies Does Not lME1l"013 :nNot Observable, :ENot Applicable ; c403.4.4. 6 lME11013 Multiple zone VAV systems with DDC ,of individual zone boxes have static : pressure setpoint reset controls. See the Mechanical Systems list for values. ,tr in :!Complies :EDoes Not Not Observable Not Applicable C408.2.2. Air outlets and zone terminal devices1 :have means for air balancing. tME53l3 .rfl :tr ilcomplies iEooes t',tot Not Observable Not Applicable Refrigerated display cases, walk-in coolers or walk-in freezers served by remote compressors and remote condensers not located in a condensing unit, have fan-powered condensers that comply with Sections :EComplies ,f]ooes Not ,!Not Observable :!Not Applicable c403.5, c403.5.1, c403.5.2 lMEt 2313 C403.5.1 and refrigeration compressor systems that comply with C403.5.2.. Additional Comments/Assumptions: Project Title: Aspen Glen Club-Fitness Center Renovation Report dafe: !0127123 Data filename: Z:\Projects\05066 - Club Corp\05066.65 - Aspen Glen Pool & Fitness Country Club Renovations\ Page 7 of 10 ComCheck\Phase 2\Pro Shop\ComCheck-Mechanical-Aspen Glen-Pro shop.cck 3 Low lm (Tier 3)1 (Tier 1)Hi hlm 2 Medium ct (Tier 2) Complies?Comments/Assumptions Section # & Req.lD Final lnspe€tion c303.3, c408.2.5 3 lFt8l3 Furnished O&M manuals for HVAC systems within 90 days of system acceptance. flComplies EDoes Not ENot Observable ENot Applicable HVAC systems and equipment capacity does not exceed calculated loads. EComplies EDoes Not ENot Observable ENot Applicable c403.2.2 lFt2713 Heating and cooling to each zone is controlled by a thermostat control. Minimum one humidity control device per installed h u m idification/deh umidification system. EComplies EDoes Not !Not Observable nNot Applicable c403.2.4. 1 lFt47l3 Heating and cooling to each zone is controlled by a thermostat control. Minimum one humidity control device per installed humidification/dehumidification lDoes Not nNot Observable ENot Applicable pliesc403.2.4. 1 lFt47l3 Heating and cooling to each zone is controlled by a thermostat control. Minimum one humidity control device per installed , humidification/dehumidification EComplies EDoes Not INot Observable INot Applicable c403.2.4. 1 lFr47l3 c403.2.4. 1,1 lFt42l3 :Heat pump controls prevent supplemental electric resistance heat ,from coming on when not needed. EComplies EDoes Not ENot Observable Etrtot ble Thermostatic controls have a 5 'F ,deadband. c403.2.4. L.2 lFt3813 lEcompties iDooes ltot ENot Observable ENot Applicable c403.2.4. 1.3 lFt20l3 : Temperature controls have setpoint overlap restrictions. iEComplies ,EDoes Not nNot Observable !Not Applicable lElComplies inooes trtot inNot observable iEruot Rpplicable c403.2.4. 2 lFt39l3 : Each zone equipped with setback controls using automatic time clock or programmable control system. !Complies nDoes Not ENot Observable Eruot Applicable c443.2.4. 2.1, c403.2.4. 2.2 lFt40l3 :Automatic Controls: Setback to 55'F , (heat) and 85"F (cool); 7-day clock, 2- : hour occupant override, 10-hour , backup . : iEComplies :IDoes Not ;LNot Observable jLruot Applicable c403.2.4 2.3 IF141]3 :Systems include optimum start , controls. ;tr ;tr :tr C403.2.4. .systems include optimum start2.3 ,controls. IFt4].13 :EComplies Does Not Not Observable, Not Applicable . 2 Medium lm ct (Tier 2)3 Low I (Tier 3)1 High lmpact (Tier 1 Project Title: Data filename Aspen Glen Club-Fitness Center Renovation Report date: 10/27 123 Z:\Projects\05066 - Club Corp\05066.65 - Aspen Glen Pool & Fitness Country Club Renovations\ Page I of 10 ComCheck\Phase 2\Pro Shop\ComCheck-Mechanical-Aspen Glen-Pro shop.cck Complies?Ccmments/Assumptions Section # & Req.lD Final lnspection Commissioning plan developed by registered design professional or approved agency. ;nComplies i iEooes ltot : iEtttot observable i iEruot Applicable : c408.2.1 lFt28l1 c408.2.3. 1 lFt31l1 HVAC equipment has been tested to ensure proper operation.itr ;tr iEruot applicable : mplies Does Not Not Observable c408.2.3. 2 lFr10l1 HVAC control systems have been i[Complies : tested to ensure proper operation, :EDoes Not . caribration and adjustment of contrors. ENot observabrel ENot Applicable , ,Preli i com : desi minary commissioning report pleted and certified by registered gn professional or approved iu ,a tn Not Applicable ; agency iEcompliesc408.2.4 lFt29l1 Does Not Not Observable C408.2.5. Furnished HVAC as-built drawings1 submitted within 90 days of system lFl7l3 acceptance, :!Does Not .!Not Observable Etttot Applicable mplies c408.2.5. 3 lFt43l1 An air and/or hydronic syste balancing report is provided systems. EComplies EDoes Not !Not Observable ENot Applicable m for HVAC c408.2.s 4 lFt3oll ,Final commissioning report due to ,building owner within 90 days of : receipt of certificate of occupancy nComplies nDoes Not ENot Observable !wot Rpplicable Additional Comments/Assumptions: 2 Medium lm (Tier 2)3 Low I (Tier 3)1 High lmpact (Tier 1) Project Title: Data filename Aspen Glen Club-Fitness Center Renovation Report date Z:\Projects\05066 - Club Corp\O5066.65 - Aspen Glen Pool & Fitness Country Club Renovations\ Page ComCheck\Phase 2\Pro Shop\ComCheck-Mechanical-Aspen Glen-Pro shop.cck 10127 t23 9of 10 Project Title: Aspen Glen Club-Fitness Center Renovation Report date Data filename: Z:\Projects\05066 - Club Corp\05066.65 - Aspen Glen Pool & Fitness Country Club Renovations\ Page ComCheck\Phase 2\Pro Shop\ComCheck-Mechanical-Aspen Glen-Pro shop.cck L0t27 t23 L0 of 10 COMcheck Software Version 4.1.5.5 lnterior Lighting Gompliance Gertificate Project lnformation Energy Code: Project Title: Project Type: 2015 |ECC ASpen Glen Club-Pro shop Addition Owner/Agent: Aspen Glen Club Construction Site: 545 Bald Eagle Carbondale, CO way 81623 Designer/Contractor: Larry Garrett B&H engineers 511 E John Carpenter Fwy Suite 250 lrving, TX 75062 2L4-496-L670 lgarrett@bandhengi neers.com Allowed lnterior Lighting Power A Area Gategory B Floor Area (ft2) c Allowed Watts /ft2 D Allowed Watts (Bxc) 'l-Country club (Dining: Bar Lounge/Leisure)4478 1.01 4523 Total Allowed Watts = 4523 Proposed Interior Lighting Power A Fixture lD : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ c #of Fixtures D Fixture Watt. E (cxD) Fixture 1-Countrv club (Dinino: Bar Lounoe/Leisure) LED 1: B: 4" downlight: LED A Lamp 25W: LED 2: C: 2" spot light LED A Lamp 13W: LED 3: D: semi flush light LED A Lamp 13W: LED 4: F: semi flush light: LED A Lamp 3.2W: LED 5: H: 8" pendant light LED A Lamp 6W: LED 6: J: wall sconce light LED A Lamp 13W: LED 7: K: wall sconce lighfi LED Linear 33W: LED 8: L: chandelier: LED Linear 33W: LED 9: M: wall sconce light LED Linear 33W: LED 10: N: track light: LED Linear 33W: LED 11: T: tape lineat light: LED Linear 33W: LED 12'. 52: existing wall sconce: LED Linear 33W: 68 26 3 4 4 4 4 3 I 16 194 4 22 13 30 4 6 15 10 210 40 10 4 10 1496 338 90 16 24 60 40 630 360 160 776 40 Total Proposed Watts = 4030 lnterior Lighting Gompliance Statement Compliance Statementj The proposed interior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.5.5 and to comply with any applicable mandatory requirements listed in the lnspection Checklist. Project Title: ASpen Glen Club-Pro shop Data filename: Z:\Projects\05066 - Club Corp\05066.65 - Aspe ComCheck\Phase 2\Pro Shop\ComCheck-Lighti Report datet 06102123 n Glen Pool & Fitness Country Club Renovations\ Page 1 of 9 ng-Aspen Glen-Pro shop.cck lnterior Lighting PASSES: Desig,n 11% be.tter than code Larry Garrett - Electrical Engineer PE 06t0212023 Name - Title Signature Date Project Title: ASpen Glen Club-Pro shop Report date: 06/02123 Data filename: Z:\Projects\05066 - Club Corp\05066,65 - Aspen Glen Pool & Fitness Country Club Renovations\ Page 2 of 9 ComCheck\Phase 2\Pro Shop\ComCheck-Li ghting-Aspen Glen-Pro shop.cck COMcheck Software Version 4.1.5.5 Exterior Lighting Gompliance Certificate Project lnformation Energy Code: Project Title: Project Type: Exterior Lighting Zone Construction Site: 545 Bald Eagle Way Carbondale, CO 81623 Allowed Exterior Lighting Power A Area/Surface Gategory 2015 IECC ASpen Glen Club-Pro shop Addition 1 (Developed rural area (LZ1)) Owner/Agent: Aspen Glen Club Designer/Contractor: Larry Garrett B&H engineers 511 E John Carpenter Fwy Suite 250 lrving, TX 75062 214-496-t670 I garrett@bandhengi neers.com BC Quantity Allowed Watts / Unit E Allowed Watts (BXc) D Tradable Wattage entry to building (Entry canopy) Canopy around bldg. (Plaza area\ 54ft2 1136 ft2 0.25 0.14 Yes Yes 14 159 Total Tradable Watts (a) - 173 Total Allowed Watts = 173 fotal Allowed Supplemental Watts (b) = 500 (a) Wattage tradeoffs are only allowed between tradable areas/surfaces. (b) A supplemental allowance equal to 500 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power A Fixture lD : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture c #oI Fixtures D Fixture Watt. E (cxD) entry to building ( Entry canooy 54 ft2): Tradable Wattage LED 1: B: Pendant mounted: LED PAR 20W: LED 2: T: Tape light: LED MR 4W: LED 3: 52: Ceiling fan: LED A Lamp 6W: Canopy around bldg. ( Plaza area 1 136 ft2): Tradable Wattage 1 1 1 22 88 24 90 22 4 6 6 1 22 4 151LED 4: 32: Ceiling fan: LED A Lamp 6W: Total Tradable Proposed Watts = 224 Exterior Lighting Compliance Statement Compliance Statementj The proposed exterior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed exterior lighting systems have been designed to meet the 20L5 IECC requirements in COMcheck Version 4.1.5.5 and to comply with any applicable mandatory requirements listed in the lnspection Checklist. Project Title: ASpen Glen Club-Pro shop Report date: O6lO2123 Data filename: Z:\Projects\05066 - Club Corp\05066.65 - Aspen Glen Pool & Fitness Country Club Renovations\ Page 3 of 9 ComCheck\Phase 2\Pro Shop\ComCheck-Lighting-Aspen Glen-Pro shop.cck Lighting PASSES: Design 67% better than code Larry Garrett - Electrical Engineer PE 06t02t2023 Name - Title Signature Date Project Title: ASpen Glen Club-Pro shop Report datet 06102123 Data filename: Z:\Projects\05066 - Club Corp\05066.65 - Aspen Glen Pool & Fitness Country Club Renovations\ Page 4 ot 9 ComCheck\Phase 2\Pro Shop\ComCheck-Lighting-Aspen Glen-Pro shop,cck €OMcheck Software Version 4.1,5.5 lnspection Checklist Energy Code: 20L5 IECC Requirements: 0.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Additional Comments/Assumptions: Project Title: ASpen Glen Club-Pro shop Report date: 06/02i23 Data filename: Z:\Projects\05066 - Club Corp\05066.65 - Aspen Glen Pool & Fitness Country Club Renovations\ Page 5 of 9 ComCheck\Phase 2\Pro Shop\ComCheck-Lighting-Aspen GIen-Pro shop.cck Section # & Res.lD Plan Review €omplies? c103.2 lPR4l1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the interior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. lnformation provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices, EComplies flDoes Not !Not Observable !Not Applicable c103.2 lPR8l1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the exterior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. lnformation provided should include exterior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. DComplies [Does Not ENot Observable ENot Applicable c406 lPR9l1 , Plans, specifications, and/or : calculations provide all information :with which compliance can be :determined for the additional energy , efficiency package options. nComplies EDoes Not ENot Observable nNot Applicable , 3 Low lm (Tier 3)1 Hi lmpact (Tier 1)2 Medium lm ct (Tier 2) Section & Reo.lD Rough-ln Electrical lnspection Comp!ies?€osr! ments/Ass umptions Lighting controls installed to uniformly lEComplies reduce the lighting load by at least jEooes Not .tr :l 50o/o. c405.2.1 lELl5l1 Not Observable Not Applicable ,!Complies :!Does ruot .Etttot Observable :nruot Applicable c405.2.L lELlBll Occupancy sensors installed in required spaces. c405.2.1, c4a5.2.2. 3 lEL23l2 , lndependent lighting controls installed per approved lighting plans and all manual controls readily accessible and visible to occupants. EComplies EDoes Not INot Observable nNot Applicable C4A5.2.2. ,Automatic controls to shut off all1 building lighting installed in all lEL2212 , buildings. lComplies lDoes Not nNot Observable ENot Applicable lights independent of general area lighting. EComplies EDoes Not !Not Observable nNot Applicable c405.2.3 lEL16l2 Daylight zones provided with individual controls that control the c405.2.3, c405.2.3. 1, c40s.2.3. 2 lEL20l1 Primary sidelighted areas are equipped with required lighting controls.Not Observable ; Not Applicable : Complies Does Not c405.2.3, c40s.2.3. 1, c40s.2.3. 3 lEL21l1 Enclosed spaces with daylight area under skylights and rooftop monitors are equipped with required lighting controls. itr lEjl i" . Complies Does Not Not Observable Not Applicable c405.2.4 lEL4l1 Separate lighting control devices for specific uses installed per approved lighting plans. .EComplies 'Eooes t"tot ;Etrtot Observable j!ruot npplicable c405.2.4 lEL8l1 Additional interior lighting power allowed for special functions per the approved lighting plans and is automatically controlled and separated from general lighting. 1lComplies . ;Eooes Not ,nNot Observable , :nruot applicable . c405.2.5 lEL251n"tt Automatic lighting controls for exterior lighting installed. Controls will be daylight controlled, set based on business operation time-of-day, or reduce connected lighting > 30%. EComplies lDoes Not ENot Observable DNot Applicable flComplies !Does Not nNot Observable !Not Applicable c405,3 lEL6l1 Exit signs do not exceed 5 watts per face. Additional Comments/Assumptions: 1 lm (Tier 1)Hi 2 Medium lm (Tier 2)3 Low lm (Tier 3) Project Title: Data filename ASpen Glen Club-Pro shop Report date: 06102123 Z:\Projects\05066 - Club Corp\05066.65 - Aspen Glen Pool & Fitness Country Club Renovations\ Page 6 of I ComCheck\Phase 2\Pro Shop\ComCheck-Lighting-Aspen Glen-Pro shop.cck Medium ct Low I (Tier 3LHigh lmpact (Tier L) Project Title: Data filename ASpen Glen Club-Pro shop Report date: 06102123 Z:\Projects\05066 - Club Corp\05066.65 - Aspen Glen Pool & Fitness Country Club Renovations\ Page 7 of 9 ComCheck\Phase 2\Pro Shop\ComCheck-Lighting-Aspen Glen-Pro shop.cck Section # & Reo.lD Final lnspe€tion Complies?Comments/Assumptions c303.3, c408.2.5 2 lFt1713 Furnished O&M instructions for systems and equipment to the building owner or designated representative. EComplies EDoes Not ENot Observable Eruot Applicable c405.4.1 lFtlSli lnterior installed lamp and fixture lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. EComplies EDoes Not !Not Observable Ellot Applicable See the lnterior Lighting fixture schedule for values. Exterior lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. !Complies EDoes Not ENot Observable DNot Applicable See fhe Exterior Lighting fixture schedule for values.c405.5.1 lFt19l1 c408.2.5 1 lFn 613 Furnished as-built drawings for electric power systems within 90 days of system acceptance. nComplies EDoes Not nNot Observable lNot Applicable Lighting systems have been tested to ;EComplies ensure proper calibration, adjustment, :EOoes trtot programming, and operation. ;ENot Observable lENot Rpplicable c408.3 lFI33l1 Additional Com ments/Assum ptions: 1 hlm (Tier 1)H 2 Medium lmpact (Tier 2)3 Low lmpact (Tier 3) Project Title: ASpen Glen Club-Pro shop Data filename: Z:\Projects\05066 - Club Corp\O5066.65 - As ComCheck\Phase 2\Pro Shop\ComCheck-Li g Report date: 06/02123 Glen Pool & Fitness Country Club Renovations\ Page 8 of 9 g-Aspen Glen-Pro shop.cck pen htin Project Title: ASpen Glen Club-Pro shop Report date: 06/02123 Data filename: Z:\Projects\05066 - Club Corp\05066.65 - Aspen Glen Pool & Fitness Country Club Renovations\ Page 9 of 9 ComCheck\Phase 2\Pro Shop\ComCheck-Li ghting-Aspen Glen-Pro shop.cck