Loading...
HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT BLRE-05 -24-8695 LIZ SPANEL & DEREK SILBERNAGEL Attached Garage / Primary suite and Entry Addition/ Renovations 190 Piedmont Rd, GWS Chelyn Acres, f racl2 1) ALL WORK SHALL COMpLy W|TH THE 2015 TNTERNATIONAL RESTDENTIAL CODE (l.R.C.) AND 201B INTERNATIONAL ENERGY CONSERVATION CODE (I.E.C.C.) 2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE ATTACHED "GARFIELD COUNTY BU I LDI NG REOUI REM ENTS". NUMBER REFERENCES NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST. 3) ELECTRTCAL pERMtTTtNG AND TNSpECTtONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY. 4) ALL EXTERIOR LIGHTING TO BE DOWNCAST AND SHIELDED. S) WILDFIRE MITIGATION RECOMMENDATIONS: SHOULD COMPLY WITH WILDFIRE MITIGATION AND DEFENSIBTE SPACE REOUIREMENTS OF THE COLORADO STATE FOREST SERVICE AND LOCAL FIRE DISTRICT. SEE GARFIELD COUNTY COMMUNITY DEVELOPMENT DEPARTMENT WEBSITE FOR FURTHER INFORMATION. 6) OpEN HOLE SOTLS REPORT REOUTRED AT FTRST FOOTING TNSPECTION ,2,000 PSF SOIL BEARING CAPACITY. 7) PRE-ENGTNEERED ROOF TRUSSES. HAVE ENGINEERTNG FOR BUILDING INSPECTOR AT TIME OF FRAME INSPECTION. B) VERIFY NO CONSTRUCTION PARKING / STAGING AREA OVER THE EXISTING SEPTIC TANK AND LEACH FIELD AREA. 9) LOCATTON TMPROVEMENT CERTTFTCATE, SEALED BY A COLORADO LICENSED SURVEYOR, IS TO BE COMPLETED AT TIME OF FOUNDATION INSTALLATION (AND REMITTED TO BUILDING INSPECTOR DURING FRAME INSPECTION)- INCLUDING ROOF OVERHANGS, DECKS AND OTHER PROJECTIONS - SHOWN IN COMPLIANCE WITH GARFIFLD COUNry ZONING SETBACKS. SEE ZONING ATTACHMENTS FOR GUIDANCE. A- 0slf, 6\ €E.-5p N 2. ZONE DISTRICT REGULATIONS.Drvrsro OoND lT /o/7/ 4*mzhna,tf The purpose of this Division is to identify the lot and building restrictions for each zone district' ln addition to these general requirements, all land uses shall comply with the applicable standards set forth in Article 7, Standards' 3-2A1. ZONE DISTRICT DIMENSIONS. Table 3-201 identifies the dimensional standards for each zone district $ * $.t Front Slde Maxlmum Floor Area Ratio Arterlal Local Rear Maximum Lot Coverage (w Mlnimum Lot Areal Zone Dlstrict 10 R:25 NR: 4050.E,at15N/A2 acresRural R 255025.E 105050o/o20,000 s.f.Residential - Suburban RS 255025.E,105050o/o7,500 s.fResidential - Urban RU 25 25 10 25502 acres 50 Residential-M anufactured Home Park MHP 10 405025R: 25 C:7.5 NC:75 C: 85 50%7,500 s.fCommercial - Limited CL 405025R: 25 C: 7.5 10NC:75 C: 85 5Qo/o7,500 s.fCommercial - General CG 4050.R 25 1075N/A21,780 s]flndustrial I 50251E252535 acresPlateau RLP 25 25 50252535 acresEscarpment RLE 25 5025NE.A35 acresTalus Slopes RLTS 10 752525251535 acres R: 2 acres Gentle Slopes RLGS Subject to FAA, FAR Part 77, Airporl Layout Plan, Building Codes, and other applicabte Federal, State, and local standards and regulations Public Airport PA Public Lands PL 1 2 4 pursu evcmni heioht ons.nart from ntral Water Distribution and Wastewater System.Udesa otherwise required by section 7-'1 05, Adequate Ce provided they are reviewed (if required) and approvedTelecommunication Facilities may exceed maximum height ant to Table 3-403, Use Table exceed building height limitations by 4 feet.Parapet walls may non-inhabitable building appurtenances, andtowers, elevator cupolas, towes, and similarStacks, vents, cooling Worshio shall be limitatiof a Place ofcupolas. spires. and belfries constructed as Legend R=Residential NR=Nonresidential C=Commercial NC=Noncommercial Tabfe 3-201: Zone District Dimensions Lot Size Setbacks (feet) Height {fee0 !,4,5 GARFTELD Goururv LAND UsE AND DEVELoPMENT CoDE 3-5 Cot/ptTrol/ 1*a/4/ru/,/ CHELYN ACRES SUBDTVISION FIRST FILINGNAME W1/2 Section 3, T7S, R89W - SE1/4SW1/4 Section 34, T65, R89W - GLENWOOD SPRINGS Single Family ResidentialPrimary Use agl13171Date Approved. NoneResolution No A/R/RDZontng: Individual WellWater ISDSSewer: Gas: 127.7Number Acres Total Lots 29Dwelling Units 32Built Out Electric Service is on Border Between Glenwood Springs and Holy Cross Electrical Service Areas May be additional lot splits based on Assessor's Office Information, Original design showed onty 291ots, additionai splits by exemption and prior to subdivision regulations Chelyn Acres does not have a recorded subdMsion plat and therefore may not be legally a subdivision School Impact Fee is APPlicableSchool Impact: 25'Front 25'Rear 10' SidesSetbacks; NoCovenants NoArch. Review: NoFireplace Res 25',Building Height May,7997Revised: