HomeMy WebLinkAboutComm Check-Envelope ComplianceCOMch eck Software Version COMcheckWeb Envelope Gom pl iance Gertificate Project lnformation Energy Code: Project Title: Location: Climate Zone: Project Type: Vertical Glazing / Wall Area: Construction Site: 252 C.R. t67 GLENWOOD SPRINGS, Colorado 81601 Building Area 2018 tECC 23045 - Schafer and Company Warehouse Glenwood Springs, Colorado 5b Addition 22o/o Owner/Agent: Bucky Schafer Schafer & Company 303-8 19-9706 bucky@scmetals. com Floor Area Desig ner/Contractor: Mark Sorensen AEC PO BOX 8489 Avon, Colorado 81620 970-748-8520 mark@aec-vail.com 1-Offices and Sales (Office) : Nonresidential 2-Apartment (Multifamily) : Residential 2463 992 Envelope Assemblies Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factorr"r Roof: Metal Building, Standing Seam, Liner System with Thermal Blocks (d), IBldg. Use 1 - Offices and Sales] Floor: Unheated Slab-On-Grade Fully insulated (uniform R- value across perimeter + under entire slab), IBldg. Use 1 - Offices and Salesl (c) Floor: Unheated Slab-On-Grade Fully insulated (uniform R- value across perimeter + under entire slab), IBldg. Use 2 - Apartmentl (c) NORTH Ext. Wallr Metal Building Wall, Single Layer Mineral Fiber (in cavity, thermal block at girt), IBldg. Use 1- Offices and Sales] 6046 SL: Vinyl Frame: Operable, Perf, Specs,: Product ID TBD, SHGC 0.38, IBldg. Use 1 - Offices and Sales] (b) 4046 SL: Vinyl Frame: Operable, Perf. 5pecs.: Product lD TBD, SHGC 0.38, IBldg, Use 1 - Offices and Sales] (b) 4050 SL: Vinyl Frame: Operable, Perf. Specs.: Product lD TBD, SHGC 0.38, PF 2.30, IBldg. Use 1- Offices and Sales] (b) I' Garage: Glass (over 50% glazing): Metal Frame, Entrance Door, Perf. Specs.: Product lD TBD, SHGC 0.61, PF 2,30, IBldg, Use I - Offices and Salesl (b) 3070 GL: Glass (over 50% glazing): Metal Frame, Entrance Door, Perf, Specs,: Product lD TBD, SHGC 0.61, PF 2.30, IBldg. Use 1 - Offices and Salesl (b) Basement: Solid Concrete, 8in. Thickness, Normal Density, Furring: Wood, Wall Ht 9.2, Depth B.c. 6.4, [Bldg. Use 1 - Offices and Salesl 2050 105 137 35.0 0.0 15.0 15.0 0.033 0.300 0.300 0.035 0.540 0.540 0.052 0.450 0.450 0.450 0.770 0.770 0.119 719 27 18 20 56 21 0.052 0.450 0.450 0,450 0.630 0.630 0.050 30.0 0.0 13,0 7 .5187 Project Title: 23045 - Schafer and Company Warehouse Data filename: Report date: 04125124 Page 1 of 17 Assembly Gross Area or Perimeter Gavity R-Value Cont, R-Value Proposed U-Factor Budget U- Factorr"r 5050 SL: Vinyl Frame: Operable, Perf. Specs.: Product lD TBD, SHGC 0,38, IBldg. Use 1 - Offices and Sales] (b) Basement: Solid Concrete, 8in. Thickness, Normal Density, Furring: Wood, Wall Ht 9,2, Depth B.G. 6.4, IBldg. Use 2 - Apaftmentl 3068 WOOD: Wood, Swinging, IBldg. Use 2 - Apartment] 4050 SL: Vinyl Frame: Operable, Perf. Specs.: Product lD TBD, SHGC 0.38, [Bldg. Use 2 - Apaftment] (b) EAST Ext, Wall: Metal Building Wall, Single Layer Mineral Fiber (in cavity, thermal block at girt), IBldg. Use 1- Offices and Sales] 3070 GL: GIass (over 50% glazing): Metal Frame, Entrance Door, Perf. Specs.: Product lD TBD, SHcC 0.38, IBldg. Use 1- Offices and Salesl (b) 3646 SL: Vinyl Frame: Operable, Perf, Specs.: Product lD TBD, SHGC 0.38, IBldg. Use 1 - Offices and Sales] (b) 2446 SH: Vinyl Frame: Operable, Perf. Specs.: Product lD TBD, SHGC 0.38, IBldg, Use 1 - Offices and Sales] (b) 2446 SH: Vinyl Frame: Operable, Perf. Specs.: Product lD TBD, SHGC 0.38, IBldg. Use 1 - Offices and Sales] (b) Basement: Solid Concrete, 8in. Thickness, Normal Density, Furring: Wood, Wall Ht 9.2, Depth B.G. 6.4, lBldg. Use 1 - Offices and Salesl 4050 SL: Vinyl Frame: Operable, Perf. 5pecs.: Product lD TBD, SHGC 0.38, IBldg, Use 1 - Offices and Sales] (b) SOUTH Basement: Solid Concrete, 8in. Thickness, Normal Density, Furring: None, Wall Ht 4.8, Depth B.G. 4.8, IBldg. Use 1 - Offices and Salesl Basement: Solid Concrete, 8in. Thickness, Normal Density, Furring: None, Wall Ht 4.8, Depth B.G.4.8, IBldg, Use 2 - Apartmentl WEST Ext. Wall: Metal Building Wall, Single Layer Mineral Fiber (in cavity, thermal block at girt), IBldg. Use 1 - Offices and Sales] 3070 GL: Glass (over 50% glazing): Metal Frame, Entrance Door, Perf, Specs.: Product lD TBD, SHGC 0.38, [Bldg. Use 1- Offices and Salesl (b) 6046 SL: Vinyl Frame: Operable, Perf. Specs.: Product lD TBD, SHGC 0.38, IBIdg, Use 1 - Offices and Sales] (b) 2446 SH: Vinyl Frame: Operable, Perf, Specs.: Product lD TBD, SHGC 0.38, [Bldg. Use 1 - Offices and Sales] (b) 2446 SH: Vinyl Frame: Operable, Perf. Specs.: Product lD TBD, SHGC 0.38, IBldg. Use 1 - Offices and Sales] (b) Basement: Solid Concrete, 8in, Thickness, Normal Density, Furring: Wood, Wall Ht 9.2, Depth B.G. 6,4, [Bldg. Use 2 - Apartmentl 5050 SL: Vinyl Frame: Operable, Perf. Specs.: Product lD TBD, SHGC 0.38, IBldg. Use 2 - Apartment] (b) 5050 SL: Vinyl Frame: Operable, Perf. Specs.: Product lD TBD, SHGC 0.38, IBldg. Use 2 - Apartment] (b) 25 338 20 20 13.0 7 .5 13.0 7 .5 0.370 0.450 0.450 0,050 0.450 0.119 0.370 0.450 0.052 0.770 0.450 0.450 0.450 0.1 19 0.450 0.1 19 0.119 315 21 15 10 10 298 20 0.450 0.450 0.450 0.050 0.052 0.630 0.450 0.113 0,1'13 0.052 0.630 0.450 0.450 0.450 0.050 0.450 0,450 0.030.0 97 175 7.5 7.5 351 21 27 10 10 298 25 25 0.052 0.770 0,450 0.450 0.450 0.119 0.450 0.450 30.0 0.0 13.0 7 .5 (a) Budget U-factors are used for software baseline calculations ONLY, and are not code requirements. (b) Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation (c) Slab-On-Grade proposed and budget U-factors shown in table are F-factors. (d) Thermal spacer block with minimum R-3.5 must be installed above the purlin/batt, and the roof deck secured to the p u rlin s. Project Title: 23045 - Schafer and Company Warehouse Data filename: Report date: 04125124 Page 2 of L7 Envelope PASggS: DesiEn 24olo better than code Envelope Compliance Statement Compliance Statementj The proposed envelope design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed envelope systems have been designed to meet the 2018 IECC requirements in COMcheck Version COMcheckWeb and to comply with any applicable mandatory requirements listed in the lnspection Checklist. / Mark Sorensen, f;lT flJ5* 04125124 Name - Title Signature Date Project Title: 23045 - Schafer and Company Warehouse Data filename: Report dale: Q4125124 Page 3 of 17 COMch eck Software Version CoMcheckWeb Mechanical Compliance Gertificate Project lnformation Energy Code: Project Title: Location: Climate Zone: Project Type: Construction Site: 252 C.R, 167 GLENWOOD SPRINGS, Colorado 81601 2018 |ECC 23045 - Schafer and Company Warehouse Glenwood Springs, Colorado 5b Addition Owner/Agent: Bucky Schafer Schafer & Company 303-8 19-9706 bucky@scmetals.com Desig ner/Contractor: Mark Sorensen AEC PO BOX 8489 Avon, Colorado 81620 970-748-8520 mark@aec-vail.com Mechanical Systems List Quantity System Type & Description 1 HP-1 (Unknown): VRF Condensing Unit, Air Cooled Heat Pump Heating Mode: Capacity : :+ kBtu/h, No minimum efficiency requirement applies Cooling Mode: Capacity = Zg kBtuih, No minimum efficiency requirement applies Fan System: None 1 FC-1 (Single Zone): Cooling: l each -VRF Zone Fan Unit, Capacity = 7 kBtu/h, Unknown Economizer No minimum efficiency requirement applies Fan System: FC-1 | Kitchen/Living - Compliance (Motor nameplate HP and fan efficiency method) : Passes Fa ns: FAN 1 Supply, Single-Zone VAV, 297 CFM, 0,1 motor nameplate hp, 67,0 fan efficiency grade, 0.0 total fan efficiency, 0.0 design fan efficiency, fan exception: Single fan <= 5HP FC-2 (Single Zone): Cooling: l each -VRF Zone Fan Unit, Capacity:5 kBtu/h, Unknown Economizer No minimum efficiency requirement applies Fan System: FC-2 & 3 | Bedroom 1-- Compliance (Motor nameplate HP and fan efficiency method) : Passes Fans: FAN 2 Supply, Single-Zone VAV,237 CFM, 0.1 motor nameplate hp, 67.0 fan efficiency grade, 0,0 total fan efficiency, 0.0 design fan efficiency , fan exception: Single fan <= 5HP FC-3 (Single Zone): Cooling: l each -VRF Zone Fan Unit, Capacity = 5 kBtuih, Unknown Economizer No minimum efficiency requirement applies Fan System: FC-2 & 3 | Bedroom 1-- Compliance (Motor nameplate HP and fan efficiency method) : Passes Fans: FAN 2 Supply, Single-Zone VAV, 237 CFM, 0.1 motor nameplate hp, 67,0 fan efficiency grade, 0.0 total fan efficiency,0,0 design fan efficiency, fan exception: Singlefan <= 5HP F-1 (Single Zone): Heating: 1 each - Central Furnace, Gas, Capacity = 120 kBtu/h Proposed Efficiency = 96.50% Et, Required Efficiency: 80,00 % Et or 80% AFUE Fan System: F-1 | Office - Compliance (Motor nameplate HP and fan efficiency method) : Passes 23045 - Schafer and Company WarehouseProject Title: Data filename Report date: 04125124 Page 4 of L7 Quantity System Type & Description Fa ns: FAN 3 Supply, Constant Volume, 2200 CFM, 1.0 motor nameplate hp, 67.0 fan efficiency grade, 0.0 total fan efficiency, 0.0 design fan efficiency , fan exception: Single fan <= 5HP 1 CU-l (Single Zone): Cooling: 1 each - Split System, Capacity = 57 kBtu/h, Air-Cooled Condenser, No Economizer, Economizer exception Heat Recovery System Proposed Efficiency = 16.00 SEER, Required Efficiency = 13.00 SEER Proposed Paft Load Efficiency = 0.00 , Required Part Load Efficiency = 0.00 Fan System: F-1 I Office -- Compliance (Motor nameplate HP and fan efficiency method) i Passes Fans: FAN 3 Supply, Constant Volume, 2200 CFM, 1,0 motor nameplate hp, 67.0 fan efficiency grade, 0.0 total fan efficiency, 0.0 design fan efficiency , fan exception: Single fan <= 5HP 1 WH-1: Gas Storage Water Heater, Capacity: 50 gallons, lnput Rating: 100 kBtu/h w/ Circulation Pump Proposed Efficiency: 96.00 % Et, Required Efficiency: 80.00 % Et Mechanical Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the 2018 IECC requirements in COMcheck Version COMcheckWeb and to comply with any applicable mandatory requirements listed in the lnspection Checklist, Mark Sorensen, EIT 04125124r[t s* Name - lltle Signatu re Date 23045 - Schafer and Company WarehouseProject Title: Data filename Report datei 04125124 Page 5 of L7 COMcfi eck Software Version COMcheckWeb lnspection Checklist Energy Code: 2018 IECC Requirements; 0.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # & Req.lD Plan Review ;Plans and/or specifications provide all i information with which compliance :can be determined for the building ienvelope and document where .exceptions to the standard are :claimed. c103.2 lPR1l1 ,nNot Observable .!ruot epplicaote Complies Does Not Plans, specifications, and/or calculations provide all information with which compliance can be determined for the mechanical systems and equipment and document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and handbooks. Compliesc103.2 lPR2l1 nDoes Not nNot Observable nruot applicable Plans, specifications, and/or calculations provide all information with which compliance can be determined for the service water heating systems and equipment and document where exceptions to the standard are claimed. Hot water ncomplies lDoes Not nNot Observable nruot npplicable s m sized per manufacturer's c103.2 lPR3l1 a rea area <= 30 llCompliesThe vertical fenestration percent of the gross above-grade wall llDoes Not c402.4.7 lPRloll :!Not Observable; .nruot npplicaole . :nDoes Not ,nNot Observable ;nruot applicable The skylight area <= 3 percent of the ;nComplies gross roof area c402.4.r lPR11l1 ln enclosed spaces > 2,500 tt2 directly under a roof with ceiling heights >15 ft. and used as an office, lobby, atrium, concourse, corridor, storage, gymnasium/exercise center, convention center, automotive service, manufacturing, non- refrigerated warehouse, retail store, distribution/sorting area, transportation, or workshop, the following requirements apply: (a) the daylight zone under skylights is >= half the floor area; (b) the skylight area to daylight zone is >: 3 percent with a skylight W >: 0.40; or a minimum skylight effective a perture >= 1 percent. ;!Complies iflDoes trtot ;fltrtot observable inNot Applicable c402.4.2 lPR14l1 1 Hi lm act (Tier 1)2 Medium lm ct (Tier 2)3 Low lmpact (Tier 3) 23045 - Schafer and Company WarehouseProject Title: Data filename Report date: 04125124 Page 6 of 17 ilNot Observable ble:l--lNot c405,5 tPR16l1 Group R-2 dwelling units have separate electrical meters. : Plans, specifications, and/or ; calculations provide all information :with which compliance can be ldetermined for the additional energy r!Not :LlNote options. .flOoes trtot pliesc406 lPRgl1 Observable Applicable Additional Comments/Assumptions : Medium (Tier 2)3 Low I (Tier 3)1 High lmpact (Tier 1) Project Title: 23045 - Schafer and Company Warehouse Data filename: Report date: 04125124 Page 7 of L7 Section # & Req.lD Footlng / Foundation lnspectlon Complles?Comments/Assumptlons c303,2 lF02l, Below-grade wall insulation installed per manufacturer's instructions. :nComplies jnDoes Not ,nNot Observable ;nruot npplicanle c303,2 lF04l, Slab edge insulation installed per manufacturer's instructions. ,nComplies rnDoes Not ;nNot Observable inruot applicable c303.2.1 Exterior insulation protected damage, sunlight, moisture, landscaping and equipment maintenance activities. a gai nst wind, flcomplies nDoes Not !Not Observable flruot applicable IF06]1 c402.r.4 lFo112 Installed below-grade wall insulation type and R-value consistent with insulation specifications reported in plans and COMcheck reports. nComplies nDoes Not nNot Observable See the Envelope Assemblies table for values INot Applicable : c105 lF03l2 lnstalled slab-on-grade insulation type :IComplies and R-value consistent with insulation ,nOoes Not specifications reported in plans and lNot ObservablecoMcheck reports' ,-rrrot appticaure See the Envelope Assemblies table for values c402.2.4 lF07l2 Slab edge insulation depth/length. Slab insulation extending away from building is covered by pavement or >: 10 inches of soil. ncomplies nDoes Not nNot Observable nruot Applicable See the Envelope Assemblies table for values C403.12.2 Snow/ice melting system and freeze , protection systems have sensors and C403.12.3 controls configured to limit service for IF09]3 pavement temperature and outdoor temperature. future connection to :controls. ncomplies lDoes Not nNot Observable nNot Applicable Additional Comments/Assumptions: 1 hlm ct (Tier 1)H 2 Medium I (Tier 2)3 Low I t (Tier 3) 23045 - Schafer and Company WarehouseProject Title: Data filename Report date: 04125124 Page 8 of 17 Section # & R€o.lD Framlng / Rough-ln lnspectlon Complles?Comments/Assumptlons tnComplies jlooes l,tot ilNot observable :[Not Applicable c303.1.3 lFR12l2 Fenestration products rated in accordance with NFRC. c303.1.3 ,Fenestration products are certified as ,lComplies lFR13l1 :to performance labels or certificates ,nDoes Not;provided. ;!Not Observable ;!ruot aPPlicable C402.4.3 :Vertical fenestration SHGC value lFR10l1 :, :nComplies ,see the Envelope Assemblies table for values j[ooes Not : :It',lot Observable : :nruot npplicable . c402.4.3, c402.4.3. 4 lFRBll ;lnstalled vertical fenestration U-factor,nComplies , and SHGC consistent with label ,nDoes trtot ,specifications.and as reported in plans nloitnseru.ot":and coMcheck reports. tEruoi nppri..or" rSee the Envelope Assemblies table for values ;The building envelope contains a icontinuous air barrier that is sealed in ;an approved manner and either , constructed or tested in an approved imanner. Air barrier penetrations are :sealed in an approved manner. :[Ooes trtot :Itt'tot Observable :INot Applicable Compliesc402.5.1 lFR1611 c402.5.2, c402.5.4 lFR18l3 Factory-built fenestration and doors are labeled as meeting air leakage requirements. !Does Not INot Observable !ruot applicable .nComplies ;!Complies ilooes ruot rnNot Observable :nNot Applicable ,Vestibules are installed on all building entrances. Doors have self-closing devices. c402.5.7 lFR17l3 Additional Comments/Assumptions: 1 Hi lm ct (Tier I 2 Medium Im ct (Tier 2)3 Low lmpact (Tier 3) Project Title: 23045 - Schafer and Company Warehouse Data filename: Report dale: 04125124 Page I of 17 Section # & Rea.lD Plumblng Rough-ln lnspection Complles?Com []entslAssumptlons c404.5, c404,5.1, c404.5.2 lPL6l3 to pipe length and volume ,nOoes Not requirements. Refer to section details. lNot Observable 1!Not Applicable Heated water supply piping conforms nComplies c404.6.t, c404.6.2 lPL3l1 :Automatic time switches installed to :lComplies iautomatically switch off the lnDoes ttot rrecirculating hot-water system or heat l[ruot Observable'trace' ;Errroiappri..u" Pumps that circulate water between a inComplies heater and storage tank have controls ilOoes trlot : that limit operation from startup to ,-^,-, ^, ' <= 5 minutes after end "il;;ti"; :nNot observable' cycle. - 'LlNot APPlicable : c404.6.3 lPL7l3 : Demand recirculation water systems have controls that start the pump'upon receiving a signal from the. action of a user of a fixture or appliance and limits the temperature of the water entering the cold-water ,piping to 104'F. ;nComplies '!Ooes tr,tot ,nNot Observable i[ruot applicabte c404.7 lPL8l3 Additional Comments/Assumptions: 1 Hi lmpact er 1)Medium lmpact (Tier 2)3 Low I (Tier 3) 23045 - Schafer and Company WarehouseProject Title: Data filename Report date: 04125/24 Page 10 of 17 Section # & Reo.lD Mechanical Rough-ln lnspectlon Complles?Comments/Assumptlons Thermally ineffective pa sensible heating panels insulation >= R-3.5. nel surfaces of .nComplies ihave nDoes Not !Not Observable nNot Applicable c402.2.6 lME4113 c402.5.5, c403.2.4. 3 lME313 Stair and elevator shaft vents have lnComplies motorized dampers that automatically jnOoes Not close. Refernece section C4O3,7.7 for ,aruot Observableoperational details' ,irrroi appri.rnr" outdoor air and exhaust systems have:nComplies . motorized dampers that automatically .nDoes Not l shut when not in use and meet maximum leakage rutur. Ol"ii flNot observable: gravity damperiwhere allowed. L-Jruot npplicable ' [eference section language for '. : operational deta ils. c403.7.1 lME58l3 ncomplies nDoes Not nNot Observable nNot Applicable C403.11.3 HVAC piping insulation insulated in [ME61]'? accordance with Table C403.11.3. lnsulation exposed to weather is protected from damage and is provided with shielding from solar radiation. HVAC fan systems at design conditions do not exceed allowable fan system motor nameplate hp or fan system bhp, see the Mechanical Systems list for values. ,tr :n c403.8.1 IME65]3 flcomplies :nDoes Not Not Observable Not Applicable Fans have efficiency grade (FEG) >= 67. The total efficiency of the fan at the design point of operation <: ISVo of maximum total efficiency of the fan. c403.8.3 lME117i2 EComplies lDoes Not !Not Observable Iruot Rpplicable nComplies nDoes Not INot Observable ,!ruot Rpplicable Motors for fans that are not less than IlI2 hp and less than t hp are electronically commutated motors or have a minimum motor efficiency of 70 percent, These motors have the means to adjust motor speed. c403.8.4 lME14212 and chiller water/evaporative cooling ,nDoes Not system with fans > 1/4 hp are designed to vary ffre inoJoiran airflow nNot observable as aJunction of load and comply with LlNot Applicable deta iled uirements of this section. Each DX cooling system > 65 kBtu pliesc403.8.5 lME143l' C403.12,1 Systems that heat outside the building ,ncomplies lME71l'? envelope are radiant heat systems ,nOoes Not controlled by an occupancy sensing device or timer switch. 'nNot observable lnNot Applicable nComplies nDoes Not INot Observable nNot Applicable lNatural or mechanical ventilation is ' provided in accordance with lnternational Mechanical Code , Chapter 4. Mechanical ventilation has :capability to reduce outdoor air supply , :to minimum IMC Cha 4 c403.2.2 lME59l1 ,nComplies ,nooes Not ,nruot Observable :nruot Rpplicable , Demand control ventilation provided'for spaces >500 ft2 and >25 people/1000 ft2 occupant density and , served by systems with air side , economizer, auto modulating outside :air damper control, or design airflow ,>3,000 cfm. c403.7.1 lME59l1 1 High lm ct (Tier 1)2 Medium (Tier 2)3 Low (Tier 3) 23045 - Schafer and Company WarehouseProject Title: Data filename Report date: Q4125124 Page 11 of 17 Section # & Req.lD Mechanical Rough-ln lnspectlon Complles?Comments/Assumptions Enclosed parking garage ventilation has automatic contaminant detection and capacity to stage or modulate fans to 50Vo or less of design capacity rnComplies :nooes Not ,ENot Observable :nNot Rpplicable c403.7.2 lME115l3 HVAC systems serving guestrooms in croup R-1 buildings with > 50 guestrooms: Each guestroom is provided with controls that automatically mana ge temperature setpoint and ventilation (see sections C403.7.6.1 and C403.7.6,2). ,nComplies nDoes trlot nNot Observable ,flNot Applicable c403.7.6 lME14113 C4O3,1 ,4 rExhaust air energy recovery on [ME57]1 ,systems meeting Table C403.7.4(1) :and C4O3.7.4(2). tncomplies jnooes Not iINot observable :nruot applicable Kitchen exhaust systems comply with replacement air and conditioned supply air limitations, and satisfy hood rating requirements and maximum exhaust rate criteria. flComplies !Does Not nNot Observable nNot Applicable c403.7.5 lM E 11613 C403,11.1 HVAC ducts and plenums insulated in , accordance with C403,11.1 and C403.11.2 constructed in accordance with lME60l2 C4o3.II.2, verification may need to occur during Foundation lnspection. lDoes Not INot Observable [lNot Applicable Complies Closed-circuit cooling tower within heat pump loop have either automatic bypass valve or lower leakage positive closure dampers. Open-circuit tower'within heat pump loop have automatic valve to bypass all heat pump water flow around the tower. Open- or closed-circuit cooling towers used in , conjunction with a separate heat exchanger have heat loss by shutting down the circulation pump on the cooling tower loop, Open- or closed circuit cooling towers have a separate heat exchanger to isolate the cooling tower from the heat pump loop, and , heat loss is controlled by shutting down the circulation pump on the cooli tower loo Compliesc403,4.3 3.2 lME121l3 nDoes Not nNot Observable flNot Applicable with integral heating include automatic controls that shut off the heating system when outdoor air temperatures > 45F. Vestibule heating and cooling systems controlled by a thermostat in the vestibule with heating setpoint <= Heating for vestibules and air curtains omplies int >= BOF60F and coolin c403.4.1 4 lME6312 nOoes t',tot ,!Not Observable ,nNot Applicable C403.3.3 rHot gas bypass limited to: <=240 lME35l1 , kBtu/h - 50Vo >240 kBtu/h - 25o/o nNot Observable INot npplicable Complies Does Not 1 High lmpact (Tier 1)2 Medium lm (Tier 2)3 Low I (Tier 3) 23045 - Schafer and Company WarehouseProject Title: Data filename Report date: 04125124 Page 12 of 17 & Reo.lD Section #Mechanical Rough-ln lnspectlon Complles?Comments/Assumptlons Gas-fired water-heating equipment installed in new buildings: where a 'singular piece of water-heating equipment >= 1,000 kBtu/h serves ,the entire building, thermal efficiency>: 90 Et. Where multiple pieces of , water-heating equipment serve the 'building with combined rating >= :1,000 kBtu/h, the combined input- ' capacity-weighted-average thermal efficiency >: 90 Et, Exclude input rating of equipment in individual , dwelling units and equipment <= 100 ,kBtuih. c404,2.1 lMEl1112 ,!Complies :nooes Not nNot Observable nruot npplicable c408.2.2 1 lME5313 Air outlets and zone terminal devices have means for air balancing.Does Not flruot icable tes nNot Observable Refrigerated display cases, walk-in coolers or walk-in freezers served by remote compressors and remote condensers not located in a , condensing unit, have fan-powered:condensers that comply with Sections ncomplies nDoes Not !Not Observable !ruot npplicable ation compressor with C403.5.2.. .5.c403 a1 dn er th at c403,5, c403.5,1, c403.5.2 lME12313 Additional Comments/Assumptions: 1 hlm ct (Tier 1)H 2 Medium lm ct (Tier 2)3 Low lmpact (Tier 3) Project Title: 23045 - Schafer and Company Warehouse Data filename: Report date: 04125124 Page 13 of 17 Complles?Comments/Assumptlons Section # & Req.lD Rough-ln Electrlcal lnsp€ctlon Low-voltage dry-type distribution electric transformers meet the minimum efficiency requirements of Table C405.6. ,EComplies i jnooes Not l .nruot Observable , ;nruot Rpplicable . c405,6 lEL26l' Electric motors meet the minimum efficiency requirements of Tables C40s.7(1) through C4os.7 (4). Efficiency verified through ceftification under an approved certification program or the equipment efficiency ratings shall be provided by motor manufacturer (where certification proqrams do not exist). ,ncomplies rnDoes Not :nNot Observable 'nruot Applicable c405,'l lEL2712 Escalators and moving walks comply with ASME A17,1/CSA 844 and have automatic controls configured to reduce speed to the minimum permitted speed in accordance with ASME A17.I/CSA 844 or applicable local code when not conveying passengers. ,nComplies ,nooes trtot ,nNot Observable ,nNot Applicable c405.8.2, c405.8.2. 1 lEL28l2 Total voltage drop across the combination of feeders and branch circuits <= 5Vo. !Complies nDoes Not INot Observable :flNot Applicable , c405.9 lEL29l, Additional Comments/Assumptions: 1 ct (Tier 1)Hi hlm 2 Medium I (Tier 2)3 Low lm ct (Tier 3) Project Title: 23045 - Schafer and Company Warehouse Data filename: Report date: 04125124 Page 14 of L7 Section # & Req.lD Insulation Inspection Complies?Comments/Assumptions tRoof insulation installed per I manufacturer's instructions. Blown or :poured loose-fill insulation is installed ,only where the roof slope is <:3 in',t2. Complies Does Not Not Observable Not Applicable il ]n c303.1 ltN3l1 'n:n lnsulation installed on a suspended ceiling having ceiling tiles is not bei specified for roor/ceili ng assemblies Nes otng:noo onruot bservablContUntnsouslatioUbnrdoanstalednruotcableApplior2oremwithntslayersedgJo betweenoffset tesc402.2.r ltN 2011 Building envelope insulation is labeled wlth R-value or insulation certificate providing R-value and other relevant data. ;nComplies , lnDoes tlot : ]nruot observabte i .nruot npplicable : c303.1 llN 1012 Above-grade wall insulation installed per manufacturer's instructions. ,ncomplies i :nooes Not ' :[Not Observable: nNot Applicable : c303.2 ilN711 lnstalled above-grade wall insulation type and R-value consistent with insulation specifications reported in plans and COMcheck reports. ,nComplies .See the Envelope Assemblies tabte for values. lDoes Not rnruot Observable: ,nruot Applicable ; c105 ltN6l1 lnstalled floor insulation type and R- value consistent with insulation specifications reported in plans and COMcheck reports, ,ncomplies 'EDoes trtot ,LJNot Observable ;nNot Applicable See the Envelope Assemblies table for values,c402.2.3 lrN8l, Radiant panels and associated components, designed for heat transfer from the panel surfaces to the occupants or indoor space are insulated with a minimum of R-3.5. nComplies nDoes Not !Not Observable nNot Applicable c402.2.6 ltN 1813 ,lnstalled roof insulation type and R- ;value consistent with insulation specifications reported in plans and COMcheck reports. For some ceiling ,systems, verification may need to nDoes Not INot Observable nNot Applicable c105 See the Envelope Assemblies table for values. il N211 occur du Fra ln Complies iflding lked or wrapped permeable Com tesAIofsourcesateaenhpkag bui h rme a VCen seare ledlope D Noes ot cau hweat e strigasketed pped otN rvaObse ebtiflmwitholreuVA bca eotN.n App p Iwramaateri topping m mnt tze ea ka c402.5.1 1 llN 111 Additiona I Comments/Assumptions 1 High lmpact (Tier 1)2 Medium lm ct (Tier 2)3 Low lmpact (Tier 3) 23045 - Schafer and Company WarehouseProject Title: Data filename Report date: 04125124 Page 15 of 17 Section # & Reo.lD Flnal lnspectlon Complles?Comments/Assumptions c303.3, c408.2.5 3 lFt8l3 :EComplies :nDoes trtot ;nruot Observable lnruot npplicable Furnished O&M manuals for HVAC systems within 90 days of system accepta nce. ;Weatherseals installed on all Ioading , dock cargo door openings and provide 'direct contact along the top and sides .of vehicles parked in the doorway.:nN :nrrr c402.5.6 lFI37l1 ;nComplies ,IOoes trtot ot Observable ot Applicable nComplies nDoes Not nNot Observable nNot Applicable Recessed luminaires in thermal envelope to limit infiltration and be lC rated and labeled. Seal between interior finish and luminaire housing, c402.5.8 lFl26l3 nComplies , nDoes Not I nNot Observable , flt'lot npplicable : HVAC systems and equipment capacity does not exceed calculated loads. c403.2,2 lFt2713 Heating and cooling to each zone is controlled by a thermostat control. Minimum one humidity control device per installed hum idif ication/dehu midif ication system. c403.2.4. 1 lFt47l3 ,nComplies ,[Does Not nNot Observable flNot Applicable c403.2.4 1.1 lFt4213 Heat pump controls prevent ;[Complles i supplemental electric resistance heat ;!Does Not from coming on when not needed. :INot Observable, flNot Applicable c403.4.1 2 lFt3813 nComplies ,lnDoes Not , LlNot Observable : ,nNot Applicable ' Thermostatlc controls have a 5 'F deadband. c403,2,4 1.3 lFr20l3 ;flComplies :flooes t'lot ,!Not Observable :[ruot Rpplicable Temperature controls have setpoint overlap restrictions. c403,2.4. 2 lFt39l3 Each zone equipped with setback controls using automatic time clock or programmable control system. :Dcomplies l :lDoes Not : L lNot Observable :nruot npplicable : C403,2.4. Automatic Controls: Setback to 55'F2.L, (heat) and 85'F (cool); 7-day clock, 2- C403,2.4. hour occupant override, lO-hour2.2 backup lFt4013 nComplies nDoes Not ;!Not Observable .nNot Rpplicable ,Icomplies lDoes Not nNot Observable .!ruot applicable C403.2,4, Systems include optimum staft2.3 controls. lFt4113 lncomplies ,lDoes Not ,nNot Observable Heat traps installed on supply and discharge piping of non-circulating systems. nruot licable c404.3 lFt11l3 1 High lmpact (Tier 1)2 Medium lmpact (Tier 2)3 Low lmpact (Tier 3) 23045 - Schafer and Company WarehouseProject Title: Data filename Report date: 04125124 Page 16 of 17 Section # & Reo.lD Final lnspection Complles?Comments/Assumptlons g insulated in accordance with :!Complies details and Table C403.11,3, rnDoes Not ;!Not Observable :Dtrtot Applicable c404.4 lFr2sl, All pipin section Controls are installed that limit the lComplies operation of a recirculation pump :lOoes ruot installed to maintain temperature of a --. ^. storage tank. system *t,Lil ilp" ii a* ;!Not observable dedicited return pipe or a cold vv31sp ILJNot Applicable supply pipe. c404.6.1 lFt 12 13 Building operations and maintenance documents will be provided to the owner. Documents will cover manufacturers' information, specifications, programmi ng procedures and means of illustrating to owner how building, equipment and systems are intended to be installed, maintained, and rated ,n c408.1.1 lFt57l1 nNot Observable !Not Applicable Complies Does Not C408,2.1 tCommissioning plan developed by lFl28l1 lregistered design professional or , approved agency.INot Observable nNot npplicable Complies Does Not c408.2.3 1 lFt31l1 HVAC equipment has been tested to ensure proper operation. nComplies DDoes Not nNot Observable , nruot npplicable : c408.2.3 2 IFt1o]1 , HVAC control systems have been ,tested to ensure proper operation, :calibration and adjustment of controls. !Complies lDoes Not nNot Observable nNot Applicable :Preliminary commissioning report ,nComplies :'completed and certified by registered ,nDoes Not design professional or approved [Not Observable , ' agency' ;-not Rpplicante , c408.2.4 IFt29]1 Furnished HVAC as-built drawings submitted within 90 days of system accepta nce. c408.2.5 1 lFt 7 l3 lnComplies innoes tlot lnNot observable nNot Applicable An air and/or hydronic system ,nComplies balancing report is provided for HVAC :nOoes trtotsystems' lNot observable nNot Applicable c408.2.5 3 lFt4311 ,!Complies rnDoes Not : LlNot observable: tnruot applicable , c408.2.5 4 lFt30ll Final commissioning report due to :building owner within 90 days of r receipt of certificate of occupancy Additional Comments/Assumptions: 1 (Tier 1)Hi hlm 2 Medium ct (Tier 2)3 Low lmpact (Tier 3) 23045 - Schafer and Company WarehouseProject Title: Data filename Report date: 04125124 Page 17 of 17