HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT
BLRE- 10-23-8377
DEAN BACON
ADDING A NEW SINGLE-FAMILY RESIDENCE TO THE
PREVIOUSLY PERM ITTED BARN/GARAG E
587 COUNTY ROAD 122, CARBONDALE
PARCEL # 2391 04300295
1) THE APPROVED PLANS ARE TO BE ON-SlrE FOR INSPECTIONS
2) SANTTARY FACTLTTTES ARE REOUIRED TO BE PROVTDED FOR WORKERS.
3) A LIST OF REOUIRED INSPECTIONS WILL BE ATTACHED TO THE PLANS. THE STATE
IS TO PERMIT AND APPROVE THE ELECTRICAL WORK.
RMITS
4) ELECTRTCAL CODE COMPLTANCE WILL BE DETERMINED BASED ON FIELD
tNSPECTTONS PERFORMED BY THE STATE ELECTRTCAL TNSPECTOR, (303) 869-3458.
PLEASE HAVE THE INSPECTOR SIGN THE BUILDING CARD OR PROVIDE WRITTEN
DOCUMENTATION OF THE INSPECTIONS.
5) UNDERGROUND UTrLtry LOCATES rS THE RESPONSTBTLTTY OF THE OWNER OR
CONTRACTOR. 811 IS THE COLORADO UTILIry LOCATE HOT LINE.
6) DRAINAGE ACROSS PROPERTY LINES SHALL NOT EXCEED THAT WHICH EXISTED
PRIOR TO GRADING. EXCESS OR CONCENTRATED DRAINAGE SHALL BE
CONTAINED ON SITE OR DIRECTED TO AN APPROVED DRAINAGE FACILIry.
EROSION OF THE GROUND IN THE AREA OF DISCHARGE SHALL BE PREVENTED BY
THE INSTALLATION OF NON-EROSIVE DOWN DRAINS OR OTHER DEVICES.
7) SMOKE DETECTOR LOCATTONS, CO DETECTOR LOCATTONS, HANDRA|L, SAFEry
GLAZING LOCATIONS AND BATH EXHAUST FANS ARE ryPICAL RED-LINES ON
RESIDENTIAL PLANS.
B) A M|N|MUM OF 1/2" GYPSUM REOUIRED UNDER THE STAIRS.
9) A BLOWER DOOR TEST AND POSSIBLY A DUCT BLASTING TEST REPORT IS
REOUIRED PRIOR TO THE FINAL INSPECTION. IT IS YOUR RESPONSIBILITY TO SET
UP THE APPROPRIATE INSPECTIONS WITH A RATER AND SUPPLY THE INSPECTOR
WITH THE REPORT.
1O)ANY EXPOSED FOAM IS TO BE COVERED WITH AN IGNITION BARRIER OR A
THERMAL BARRTER BASED ON LOCATTON. (rRC R316)
1 1)THE HOME rS TO BE SUppLTED WrrH MECHANTCAL VENTTLATTON OF OUTDOOR
AtR. THE MtN|MUM VENTTLATTON RATE tS TO BE CFM = (0.0'1X TOTAL SOUARE
FOOTAGE OF THE HOUSE) + 7.5 X (NUMBER OF BEDROOMS +1)
12) CODE MINIMUM STATES THAT ALL HOT WATER PIPES %" AND LARGER ARE
REOUIRED TO BE INSULATED TO R-3 MINIMUM AND ALL HYDRONIC HEATING
PIPES ARE REOUIRED TO BE INSULATED TO R-3.
13)ALL EXTERTOR LTGHTTNG rS TO BE DOWNCAST AND SHIELDED
14)THE LOCATION OF THE CLOTHES DRYER COULD RESULT IN THE EXHAUST DUCT
BEING OVER THE ALLOWED 25" THEN SUBTRACTING FOR OFFSETS. THE CODE
REOUIRES THE DEVELOPED LENGTH TO BE PERMANENTLY MARKED. IF THE
DEVELOPED LENGTH IS OVER CODE, THEN THE INSTALLATION INSTRUCTIONS
FOR THE SPECIFIC DRYER IS TO BE ON-SITE DURING THE ROUGH-IN INSPECTION.
4r\Tt tr l/^r et ilrr n ra rn Dr rNrar^r r rn ATTr rr rA\/ra T/'\ A irtNil^tt t\i aAil I ln EDl\l\,rJ/ rnEr\-EJnrELt-/rJ t\JDtril\JlALLtrL.,'Al trlEEAVtrJ r\JArvilr\ilVr\Jrvr z.+ \Jr rr\\-,,lvr
THE INSULATED WALLS.
16)TYP|CAL GARAGE FtRE SEPARATTON tS 5/8" GYPSUM ON THE CEtLtNG AND %" ON
THE WALLS. THE DOOR FROM THE GARAGE TO THE HOME IS TO BE 1 3/8" SOLID
CORE OR 20 MINUTE RATED.
17)FLOOR DRATNS rN GARAGES ARE NOT ALLOWED TO BE TrED TO SEWER/SEPTIC
UNLESS ROUTED THRU A SAND/OIL SEPARATOR. OTHERWISE, DAYLIGHT THE
DRAIN OR RUN TO A DRYWELL.
1B)K|TCHEN HOODS OVER 400 CFM REOUTRE MAKE-UP ArR. THE STOVE/OVEN
MA.NUFA.CTURER SPEC!FIES THE CFI\4 REQUIRED.
19)THE DRYER IN A CLOSET WILL REOUIRE 1OO SOUARE INCHES OF MAKE_UP AIR. (IRC
(:1 A10 A\vLaJ t.-l
20)ENGINEER STAMPED TRUSS DRAWINGS ARE REOUIRED TO BE PROVIDED TO THE
INSPECTOR AT FRAMING INSPECTION.
21)ANy MECHANTCAL EOUtpMENT rN THE GARAGE THE SOURCE OF IGNITION lS TO
BE ELEVATED 18" ABOVE THE GARAGE FLOOR AND APPROVED BARRIERS ARE
REOUIRED TO PROTECT EOUIPMENT FROM VEHICLE IMPACT. (IRC M1307.3 AND
M1307.3.1)
22)ALLSHOWER DOORS ARE REOUTRED TO MAINTAIN 22" lN THE CLEAR AND ARE
REOUIRED TO SWING OUT.
23) WTNDOW OpENtNGS THAT ARE OVER 72" ABOVE GRADE AND ARE LESS THAN 24"
ABOVE THE FINISHED FLOOR WILL BE REOUIRED TO HAVE WINDOW OPENING
LIMITING DEVICE SO THE WINDOW CANNOT OPEN MORE THAN 4".