HomeMy WebLinkAboutBlower Door TestResidential Air Infiltration Test Report Test date:8/2/2024 Project name:Chuy Chavez Address:195 Boulder Ridge Drive GarCo Code:2018 IECC Conditioned volume:47,310 Cubic Feet Attic:non-vented Crawlspace:conditioned Garage:excluded Measured airflow:677 CFM50 Cubic Feet per Minute at 50 Pascal Temperature; Inside:80 Temperature; Outside:89 Elevation:5,312 Corrected airflow:713 CFM50*Cubic Feet per Minute at 50 Pascal 2015 IECC maximum allowed leakage rate:3.0 ACH50 Air Changes Per Hour at 50 Pascal Tested air leakage rate:0.9 ACH50 Air Changes Per Hour at 50 Pascal Test code compliance:PASS Test notes: Tests were performed by Chris Taylor; Rated Field Inspector, RFIIN #CY5MPL * Test results have been corrected for elevation and air density temperature differential. Passes the 2018 IECC required infiltration test.