HomeMy WebLinkAbout1.09 Middle Colorado Ag Collaborative - Ryden No. 2 (Project 2)_Part311% 30% 10%10% 30% 5% DIVERSION CREST WIDTH 53.80' LOW FLOW CHANNEL TOP WIDTH 18.15' REVEGETATION AREA LOW FLOW CHANNEL DEPTH 1.70' PROPOSED CONCRETE WALL, SEE SHEET XS01 BOULDERS STREAM SUBSTRATE (D50 = 8") MATCH EXISTING GRADE 3H:1V3H:1 V EXISTING GRADE 2.0' MINIMUM VOID-FILLED RIPRAP (D50 = 12", 2' THICK (AS APPLICABLE) PROPOSED GRADE 17.5' WATER DEPTH IN POOL APPROX. 2.0' 5.0' 24-INCH PARSHALL FLUME 1 H : 1 V ( M A X . ) 1H : 1 V (M A X . ) EXISTING GRADE MATCH EXISTING GRADE MATCH EXISTING GRADE VOID-FILLED RIPRAP (D50 = 12", 2' THICK (AS APPLICABLE) 5.0' 21.6' REVEGETATION AREA REVEGETATION AREA PROPOSED GRADE 1% (MIN.) 3H:1V (MAX.) 1H : 1 V (M A X . ) 1 H : 1 V 1H: 1 V EXISTING GRADE PROPOSED GRADE 2.00' 6.00' 2.00' VOID-FILLED RIPRAP (D50 = 12", 2' THICK (AS APPLICABLE) MATCH EXISTING GRADE MATCH EXISTING GRADE 1% (MIN.) 3H:1V (MAX.)2H:1V (MAX. ) 1 H : 1 V 1H: 1 V EXISTING GRADE VOID-FILLED RIPRAP (D50 = 12"), 2' THICK (AS APPLICABLE) PROPOSED GRADE MATCH EXISTING GRADE MATCH EXISTING GRADE 2.00' 6.00' 2.00' 1% (MIN.) 1 H : 1 V 1H: 1 V EXISTING GRADE VOID-FILLED RIPRAP (D50 = 12"), 2' THICK (AS APPLICABLE) PROPOSED GRADE MATCH EXISTING GRADE 2.00' 6.00' 2.00' MATCH EXISTING GRADE 3H:1V (MAX.) JBH/DTL JBH/DTL SDS 4/26/2024 SHOWN MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 3-BUSINESS DAYS IN ADVANCE CENTER OF COLORADO OR CALL UTILITY NOTIFICATION 1-800-922-1987 811 CALL COLORADO NO.BY DATE COMMENTS SCALE DETAIL CHECK DESIGN Pl o t D a t e / T i m e : 0 4 / 2 5 / 2 0 2 4 , 0 8 : 2 7 : 2 8 P M ; G : \ W W E \ 2 1 1 - 0 2 0 \ 0 2 0 \ C A D \ 0 2 _ D W G S \ T S X X - T Y P I C A L S E C T I O N S . D W G - T S 0 1 - P R O J 2 SHEET NO. JOB NO. REVISION NO. DATE DESCRIPTIONWRIGHT WATER ENGINEERS, INC. GLENWOOD SPRINGS, CO 81602 (970)945-7755 FAX(970)945-9210 818 COLORADO AVE. P.O. BOX 219 DRAFT NOT FOR CONSTRUCTION BID SET 4/26/2024 4/26/2024 TYPICAL SECTIONS 211-020.020 ---- TS01 COMBINE RYDEN NO. 2 AND BENSON PIERSON NELSON DIVERSIONS NOTES: 1.PLACEMENT OF ALL BOULDERS SHOULD BE REVIEWED AND ACCEPTED BY THE ENGINEER. BOULDERS PLACED WITHOUT ENGINEER APPROVAL ARE SUBJECT TO REMOVAL AND REPLACEMENT. 2.CONTRACTOR SHALL WORK IN CLOSE COORDINATION WITH ENGINEER ON IMPLEMENTATION OF PROPOSED CREST ELEVATION. CONTRACTOR SHALL VERIFY CREST ELEVATION ONLY BE MODIFIED SLIGHTLY BUT TOP OF CREST ELEVATION SHALL BE ACHIEVED WITH BOULDERS AT THE TOP (I.E. NOT STREAM SUBSTRATE). 3.CONTRACTOR SHALL LIMIT WORK TO AREA NEEDED TO LIMIT DISTURBANCE. 4.STREAM SUBSTRATE SHALL BE USED AS BASE FOR BOULDERS AND TO FILL ANNULAR SPACES TO ACHIEVE GRADE AT TOP OF BOULDER OR BEDDING. CONTRACTOR TO COORDINATE WITH ENGINEER AS NEEDED. 5.ALL VOIDS BETWEEN BOULDERS SHALL BE BACKFILLED WITH STREAM SUBSTRATE. ROCK SHALL BE COMPACTED WITH EXCAVATOR BUCKET OR EQUIVALENT AND WASHED IN TO CREATE AN INTERLOCKING MASS OF BOULDERS AND STREAM SUBSTRATE. SECTION F DIVERSION CREST SECTION SECTION A DEPOSITIONAL AREA LONGITUDINAL SECTION SECTION B DEPOSITIONAL AREA HORIZONTAL SECTION SECTION C RYDEN NO. 2 TYPICAL COMBINED FLOW DITCH SECTION SECTION D RYDEN NO. 2 TYPICAL DITCH SECTION DOWNSTREAM OF FLOW SPLIT SECTION F BENSON PIERSON NELSON TYPICAL DITCH SECTION DOWNSTREAM OF FLOW SPLIT EXISTING GRADE REVEGETATION AREA: UPLAND SEED HEIGHT VARIES OFFLINE DIVERSION CHANNEL, WIDTH VARIES PROPOSED CONCRETE WALL, SEE SHEET XS01 BOULDERS MATCH EXISTING GRADE STREAM SUBSTRATE (D50 = 18") PROPOSED GRADE CONCRETE WALL FOOTERS, SEE STRUCTURAL PLANS (TYP.) PROPOSED GRADE COMPACT SUBGRADE EXISTING GRADE REVEGETATION AREA: UPLAND SEED HEIGHT VARIES OFFLINE DIVERSION CHANNEL, WIDTH VARIES REVEGETATION AREA: WILLOW STAKES PROPOSED CONCRETE WALL, SEE SHEET XS01 BOULDERS MATCH EXISTING GRADE STREAM SUBSTRATE (D50 = 18") PROPOSED GRADE CONCRETE WALL FOOTERS, SEE STRUCTURAL PLANS (TYP.) MATCH EXISTING GRADE COMPACT SUBGRADE w w w w w w w w w w w ww w wwwwwww w JBH/DTL JBH/DTL SDS 4/26/2024 SHOWN MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 3-BUSINESS DAYS IN ADVANCE CENTER OF COLORADO OR CALL UTILITY NOTIFICATION 1-800-922-1987 811 CALL COLORADO NO.BY DATE COMMENTS SCALE DETAIL CHECK DESIGN Pl o t D a t e / T i m e : 0 4 / 2 5 / 2 0 2 4 , 0 8 : 2 7 : 4 5 P M ; G : \ W W E \ 2 1 1 - 0 2 0 \ 0 2 0 \ C A D \ 0 2 _ D W G S \ T S X X - T Y P I C A L S E C T I O N S . D W G - T S 0 2 - P R O J 2 SHEET NO. JOB NO. REVISION NO. DATE DESCRIPTIONWRIGHT WATER ENGINEERS, INC. GLENWOOD SPRINGS, CO 81602 (970)945-7755 FAX(970)945-9210 818 COLORADO AVE. P.O. BOX 219 DRAFT NOT FOR CONSTRUCTION BID SET 4/26/2024 4/26/2024 TYPICAL SECTIONS 211-020.020 ---- TS02 COMBINE RYDEN NO. 2 AND BENSON PIERSON NELSON DIVERSIONS SECTION A - OFFLINE DIVERSION CHANNEL SECTION B - OFFLINE DIVERSION CHANNEL NOTES: 1.CONTRACTOR SHALL USE GEI STRUCTURAL DRAWINGS FOR CONCRETE STRUCTURES. 2.PLACEMENT OF ALL BOULDERS SHOULD BE REVIEWED AND ACCEPTED BY THE ENGINEER. BOULDERS PLACED WITHOUT ENGINEER APPROVAL ARE SUBJECT TO REMOVAL AND REPLACEMENT. 3.CONTRACTOR SHALL WORK IN CLOSE COORDINATION WITH ENGINEER ON IMPLEMENTATION OF PROPOSED CREST ELEVATION. CONTRACTOR SHALL VERIFY CREST ELEVATION ONLY BE MODIFIED SLIGHTLY BUT TOP OF CREST ELEVATION SHALL BE ACHIEVED WITH BOULDERS AT THE TOP (I.E. NOT STREAM SUBSTRATE). 4.CONTRACTOR SHALL LIMIT WORK TO AREA NEEDED TO LIMIT DISTURBANCE. 5.STREAM SUBSTRATE SHALL BE USED AS BASE FOR BOULDERS AND TO FILL ANNULAR SPACES TO ACHIEVE GRADE AT TOP OF BOULDER OR BEDDING. CONTRACTOR TO COORDINATE WITH ENGINEER AS NEEDED. 6.ALL VOIDS BETWEEN BOULDERS SHALL BE BACKFILLED WITH STREAM SUBSTRATE. ROCK SHALL BE COMPACTED WITH EXCAVATOR BUCKET OR EQUIVALENT AND WASHED IN TO CREATE AN INTERLOCKING MASS OF BOULDERS AND STREAM SUBSTRATE. 10 10 20 FT0 NORTH PLAN A TS02 B TS02 w w w ELK C R E E K RYDEN NO. 2 DITCH FABRICATED HEADGATES WITH ACTUATORS AT FLOW SPLITTER STRUCTURE, SEE NOTES AND EQUIPMENT LIST THIS SHEET FABRICATED HEADGATES WITH ACTUATORS, SEE NOTES AND EQUIPMENT LIST THIS SHEET BENSON PIERSON NELSON DITCH 30-INCH HDPE PIPE 24" FLUME (FLUME 1) WITH RADAR SENSOR ON FLUME FOR FLOW MEASUREMENT, SEE EQUIPMENT LIST THIS SHEET 30" HDPE PIPE 30" HDPE PIPE 24" FLUME (FLUME 2) WITH RADAR SENSOR ON FLUME FOR FLOW MEASUREMENT, SEE NOTES AND EQUIPMENT LIST THIS SHEET D D DITCH HEADGATE AND SLUICE GATE CONTROLLER STATION, SEE EQUIPMENT LIST THIS SHEET APPROXIMATELY 475 LF DIRECT BURIAL CABLE, SEE NOTES 24" FLUME (FLUME 3) WITH RADAR SENSOR, RADIO, AND POWER SUPPLY ON FLUME FOR FLOW MEASUREMENT, SEE NOTES AND EQUIPMENT LIST THIS SHEET APPROXIMATELY 570 LF DIRECT BURIAL CABLE, SEE NOTES APPROXIMATELY 50 LF DIRECT BURIAL CABLE, SEE NOTES FLOW SPLITTER STRUCTURE CONTROLLER STATION, SEE NOTES AND EQUIPMENT LIST THIS SHEET ELK C R E E K JBH/DTL JBH/DTL SDS 4/26/2024 SHOWN MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 3-BUSINESS DAYS IN ADVANCE CENTER OF COLORADO OR CALL UTILITY NOTIFICATION 1-800-922-1987 811 CALL COLORADO NO.BY DATE COMMENTS SCALE DETAIL CHECK DESIGN Pl o t D a t e / T i m e : 0 4 / 2 6 / 2 0 2 4 , 0 1 : 4 2 : 1 5 P M ; G : \ W W E \ 2 1 1 - 0 2 0 \ 0 2 0 \ C A D \ 0 2 _ D W G S \ O V X X - H Y D R O L O G I K P R O J E C T O V E R A L L P L A N S . D W G - T E 0 1 - P R O J 2 O V E R A L L SHEET NO. JOB NO. REVISION NO. DATE DESCRIPTIONWRIGHT WATER ENGINEERS, INC. GLENWOOD SPRINGS, CO 81602 (970)945-7755 FAX(970)945-9210 818 COLORADO AVE. P.O. BOX 219 DRAFT NOT FOR CONSTRUCTION BID SET 4/26/2024 4/26/2024 OVERALL TELEMETRY PLAN 211-020.020 ---- TE01 NORTH 40 80 FT400 PLAN COMBINE RYDEN NO. 2 AND BENSON PIERSON NELSON DIVERSIONS TELEMETRY EQUIPMENT LIST ACTUATORS ITEM NO.ITEM QUANTITY 1 WT200 HEADGATE ACTUATOR 4 CONTROLLER STATIONS ITEM NO.ITEM QUANTITY 2 12 VDC SOLAR POWER SUPPLY, STATION SUPPLIES, AND MATERIALS 2 3 CR1000X DATALOGGER/CONTROLLER 2 4 RADIO, RF407, CAMPBELL SCIENTIFICE 2 5 DIRECTIONAL RADIO ANTENNA AND ACCESSORIES 3 6 ENCLOSURE AND INSTALLATION PARTS FOR RADIO STATION AT FLUME 2 1 7 7" HMI DISPLAY, WEINTEK MT SERIES (NEMA 4-X)2 8 FABRICATION AND CONSTRUCTION SUPPLIES FOR MOUNTING ACTUATORS 4 9 CONTROLLER STATION INSTALLATION PARTS AND SUPPLIES 2 10 SYSTEM ASSEMBLY PARTS AND SUPPLIES 2 FLUME RADAR ITEM NO.ITEM QUANTITY 11 RADAR LEVEL SENSOR, VEGA C21 3 12 RADAR SPECIFIC INSTALLATION PARTS AND SUPPLIES 3 13 DIRECT BURIAL CABLE (INSULATED, 16/4C)1000 (LF) NOTES: 1.FLOW MEASUREMENT, TELEMETRY AND ACTUATORS ALL TO BE COORDINATED WITH HYDROLOGIK, INC. 2.ACTUATOR SIZE AND GEARING ARE SUBJECT TO CHANGE. 3.FLUME APPROACH CHANNEL SHOULD BE OPEN FOR A MINIMUM OF 10 TIMES THE FLUME'S THROAT WIDTH, WITH TRANQUIL FLOW CONDITIONS LEADING INTO THE FLUME. FLUMES MAY NEED A 4H:1V ENTRANCE RAMP DEPENDING ON HOW HIGH THE FLUME FLOOR IS SET ABOVE THE DITCH CHANNEL INVERT. 4.CONTRACTOR SHALL EXCAVATE RADAR CABLE TRENCH, HYDROLOGIK, LLC SHALL LAY CONDUIT AND PULL CABLES, AND CONTRACTOR SHALL BACKFILL ONCE HYDROLOGIK'S WORK IS COMPLETE. RADAR CABLE MAY BE LOCATED IN THE SAME TRENCH AS PROPOSED PIPE WHERE APPLICABLE. 5.FABRICATED HEADGATES SHOULD INCLUDE STRIPS OF ULTRA HIGH MOLECULAR DENSITY (UHMD) MATERIAL ADDED ALONG THE GATE'S BLADE-FRAME INTERFACE (SLIDES) TO REDUCE FRICTION AND IMPROVE SEAL FOR LONG TERM RELIABILITY. 6.FULL EQUIPMENT LIST AND LAYOUT FROM HYDROLOGIK AVAILABLE UPON REQUEST. CELLULAR TELEMETRY STATION (NOT SHOWN): PROVIDES TELEMETRY FOR REMOTE MONITORING AND CONTROL OF PROJECT 1 MEASUREMENT & CONTROL INFRASTRUCTURE. TO BE LOCATED ON ADJACENT HILLSLOPE, IN GOOD CELLULAR COVERAGE (2 BARS LTE, OR BETTER), AND HAVE LINE-OF-SIGHT TO PROJECT 1 & PROJECT 2 HEADGATE CONTROLLER STATIONS. IF THE CELLULAR TELEMETRY STATION LOCATION IS NOT ON RANCH PROPERTY, MAY NEED TO ACQUIRE PERMISSION TO INSTALL THIS STATION. *EXACT LOCATION OF CELLULAR TELEMETRY STATION IS TBD AND MUST BE FIELD-VERIFIED FOR CELLULAR COVERAGE AND FOR RADIO CONNECTIVITY TO PROJECT 1 & PROJECT 2 H.G. STATIONS. TRENCH FOR DIRECT-BURY CABLES : ALL FLUMES & THEIR UPSTREAM CONTROLLER STATIONS TO BE HARD-WIRE CONNECTED, AS WELL AS THE BIFURCATION STATION TO THE HEADGATE CONTROLLER STATION. TOTAL PROJECT 1 DIRECT-BURY CABLE LENGTH IS APPROX. 625 FT. *GC TO LAY CONDUIT AND PULL CABLES IN PIPE TRENCH FOR DIRECT-BURY. PROJECT PERSPECTIVE DETAILS 211-020.020 ---- DT01 JBH/DTL JBH/DTL SDS 4/26/2024 SHOWN MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 3-BUSINESS DAYS IN ADVANCE CENTER OF COLORADO OR CALL UTILITY NOTIFICATION 1-800-922-1987 811 CALL COLORADO NO.BY DATE COMMENTS SCALE DETAIL CHECK DESIGN Pl o t D a t e / T i m e : 0 4 / 2 5 / 2 0 2 4 , 0 8 : 3 2 : 5 7 P M ; G : \ W W E \ 2 1 1 - 0 2 0 \ 0 2 0 \ C A D \ 0 2 _ D W G S \ D T X X - T Y P D E T A I L S . D W G - 2 - D T 0 1 T Y P I C A L D E T A I L S SHEET NO. JOB NO. REVISION NO. DATE DESCRIPTIONWRIGHT WATER ENGINEERS, INC. GLENWOOD SPRINGS, CO 81602 (970)945-7755 FAX(970)945-9210 818 COLORADO AVE. P.O. BOX 219 DRAFT NOT FOR CONSTRUCTION BID SET 4/26/2024 4/26/2024 RYDEN NO. 2 PERSPECTIVE COMBINE RYDEN NO. 2 AND BENSON PIERSON NELSON DIVERSIONS EXISTING DIVERSION PIPE TO BE REPLACED PLACE BOULDERS TO CREATE SILL AS DIRECTED BY ENGINEER DURING CONSTRUCTION COORDINATE WITH ENGINEER TO PRESERVE AND/OR CREATE BACKWATER HABITAT LOWER THIS BOULDER 12" NOTES: 1.IMPROVEMENTS INCLUDED IN THESE PLANS INCLUDE INFRASTRUCTURE FOR THE COMBINED DIVERSION FOR THE RYDEN NO. 2 AND BENSON PIERSON NELSON DITCHES AND THE DOWNSTREAM SPLITTER STRUCTURE. PLACEMENT OF ALL BOULDERS SHOULD BE REVIEWED AND ACCEPTED BY THE ENGINEER. BOULDERS PLACED WITHOUT ENGINEER APPROVAL ARE SUBJECT TO REMOVAL AND REPLACEMENT. CONSTRUCTION ACCESS MINOR GRADING AND BOULDER WORK PROPOSED AS DIRECTED BY ENGINEER EXACT ELEVATION AND LOCATION OF SPOT TREATMENT BOULDERS TO BE DIRECTED BY ENGINEER IN THE FIELD ℄ BURY BOULDER (D50 = 36") HALFWAY INTO STREAM SUBSTRATE BOTTOM OF FEATURE BOULDER TO BE BELOW ADJACENT THALWEG SUPPLEMENT EXISTING STREAM SUBSTRATE (D50 = 18") AS NEEDED ELK C R E E K FLO W DEBRIS DEFLECTOR BOULDERS SPOT TREATMENT BOULDERS VOID-FILLED RIPRAP (D50 = 18"), 3' THICK TYPICAL DETAILS 211-020.020 ---- DT02 JBH/DTL JBH/DTL SDS 4/26/2024 SHOWN MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 3-BUSINESS DAYS IN ADVANCE CENTER OF COLORADO OR CALL UTILITY NOTIFICATION 1-800-922-1987 811 CALL COLORADO NO.BY DATE COMMENTS SCALE DETAIL CHECK DESIGN Pl o t D a t e / T i m e : 0 4 / 2 5 / 2 0 2 4 , 0 8 : 3 3 : 1 7 P M ; G : \ W W E \ 2 1 1 - 0 2 0 \ 0 2 0 \ C A D \ 0 2 _ D W G S \ D T X X - T Y P D E T A I L S . D W G - 2 - D T 0 2 T Y P I C A L D E T A I L S SHEET NO. JOB NO. REVISION NO. DATE DESCRIPTIONWRIGHT WATER ENGINEERS, INC. GLENWOOD SPRINGS, CO 81602 (970)945-7755 FAX(970)945-9210 818 COLORADO AVE. P.O. BOX 219 DRAFT NOT FOR CONSTRUCTION BID SET 4/26/2024 4/26/2024 COMBINE RYDEN NO. 2 AND BENSON PIERSON NELSON DIVERSIONS NOMINAL SIZE (D50) = B BOULDER PLACEMENT DETAILS DEBRIS DEFLECTOR BOULDERS AND SPOT TREATMENT BOULDERS SECTION VIEW NTS NOTES: 1.BOULDERS TO BE PLACED IN ACCORDANCE WITH THE DIAGRAM. 2.SALVAGE EXISTING BOULDERS FOR USE WITHIN THE CHANNEL WHERE POSSIBLE. 3.BOULDERS SHOULD BE APPROXIMATELY 1 2 TO 2 3 BURIED INTO STREAMBED MATERIAL AND SET BELOW OR AT TOP OF BANK ELEVATION. 4.BOULDERS SHALL BE OF METAMORPHIC OR IGNEOUS FORMATION (I.E. NO SANDSTONE). 5.UTILIZATION OF ON-SITE BOULDERS MIGHT REQUIRE RESTORATION FROM WHERE ACQUIRED. BOULDER SIZE SPECIFICATIONS NOTES: 1.BOULDER DETAIL IS APPLICABLE FOR PLACEMENT OF DEBRIS DEFLECTOR BOULDERS AND SPOT TREATMENT BOULDERS. INTENT OF VARIOUS BOULDERS IS DIFFERENT BUT PLACEMENT DETAILS ARE SIMILAR. 2.ALL BOULDER PLACEMENT SHALL BE DONE IN COORDINATION WITH ENGINEER. 3.CONTRACTOR SHALL ONLY EXCAVATE WHAT IS NECESSARY TO INSTALL BOULDERS. 4.ALL EXCAVATED AREAS AFTER BOULDER PLACEMENT SHALL BE BACKFILLED AND COMPACTED WITH STREAM SUBSTRATE (D50 = 18"). 5.TOP OF FEATURE BOULDERS SHOULD SLIGHTLY INCLINE IN THE DOWNSTREAM DIRECTION. 6.BOULDERS IN SERIES SHALL BE PLACED AS CLOSELY AS POSSIBLE TO EACH OTHER AND THEN CHINKED WITH STREAM SUBSTRATE. BOULDER CLASSIFICATION NOMINAL SIZE (INCHES) RANGE IN SMALLEST DIMENSION OF INDIVIDUAL ROCK BOULDERS (INCHES) MAXIMUM RATIO OF LARGEST TO SMALLEST ROCK DIMENSION OF INDIVIDUAL BOULDERS 36" BOULDER 36 32 - 40 1.50 48" BOULDER 48 44 - 52 1.50 BOULDER SIZE LOCATION DETAIL NTS LEGEND 36" BOULDER 48" BOULDER RIPRAP SPECIFICATIONS VOID-FILLED RIPRAP NOTES: 1.RIPRAP SHALL BE MIXED WITH THE MATERIALS AND ASSOCIATED PROPORTIONS LISTED IN TABLE ABOVE. 2.MIX PROPORTIONS ARE APPROXIMATE AND ARE SUBJECT TO ADJUSTMENT BY ENGINEER. 3.THE RIPRAP AND VOID FILLED MATERIALS SHALL BE STOCKPILED SEPARATELY AND THOROUGHLY MIXED PRIOR TO PLACEMENT AND SHALL BE INSTALLED AND COMPACTED SO THAT A DENSE INTERLOCKED LAYER OF RIPRAP AND VOID FILL MATERIAL IS PROVIDED WITH RIPRAP VOIDS COMPLETELY FILLED. 4.COMPACTION OF THE ANGULAR VOID-FILLED RIPRAP SHALL BE PERFORMED BY WHEEL ROLLING WITH HEAVY RUBBER-TIRED EQUIPMENT. 5.ALL ANGULAR VOID FILLED RIPRAP THAT IS BURIED WITH TOPSOIL SHALL BE REVIEWED AND APPROVED BY THE ENGINEER BEFORE ANY TOPSOIL PLACEMENT. 6.IN AREAS WHERE ANGULAR VOID FILLED RIPRAP IS BEING PLACED IN COMBINATION WITH EROSION CONTROL BLANKET, ADDITIONAL TOPSOIL SHALL BE MIXED IN TOP 9" OF RIPRAP TO DEVELOP A 50/50 MIX. NOTES: 1.PLACEMENT OF ALL BOULDERS SHOULD BE REVIEWED AND ACCEPTED BY THE ENGINEER. BOULDERS PLACED WITHOUT ENGINEER APPROVAL ARE SUBJECT TO REMOVAL AND REPLACEMENT. 2.CONTRACTOR SHALL WORK IN CLOSE COORDINATION WITH ENGINEER ON IMPLEMENTATION OF PROPOSED CREST ELEVATION. CONTRACTOR SHALL VERIFY CREST ELEVATION WITH ENGINEER PRIOR TO CONSIDERING WORK COMPLETE. 3.CREST ELEVATION ONLY BE MODIFIED SLIGHTLY BUT TOP OF CREST ELEVATION SHALL BE ACHIEVED WITH BOULDERS AT THE TOP (I.E. NOT STREAM SUBSTRATE). 4.CONTRACTOR SHALL LIMIT WORK TO AREA NEEDED TO LIMIT DISTURBANCE. 5.STREAM SUBSTRATE SHALL BE USED AS BASE FOR BOULDERS AND TO FILL ANNULAR SPACES TO ACHIEVE GRADE AT TOP OF BOULDER OR BEDDING. CONTRACTOR TO COORDINATE WITH ENGINEER AS NEEDED. 6.ALL VOIDS BETWEEN BOULDERS SHALL BE BACKFILLED WITH STREAM SUBSTRATE. ROCK SHALL BE COMPACTED WITH AN EXCAVATOR BUCKET OR EQUIVALENT AND WASHED IN TO CREATE AN INTERLOCKING MASS OF BOULDERS AND STREAM SUBSTRATE. 7.ALL BOULDERS ARE DRAWN IN PLAN AND PROFILE VIEW WITH A TYPICAL 36" DIAMETER. CONTRACTOR TO MAKE NECESSARY CALCULATION ADJUSTMENTS TO REFLECT 48" BOULDERS WHERE SPECIFIED IN THIS PLAN. STREAMBED MATERIAL 18" *GRADATION TO INCLUDE FINES ALONG WITH COBBLES GRADATION OF COBBLE FOR STREAMBED MATERIAL % SMALLER THAN GIVEN SIZE BY WEIGHT INTERMEDIATE ROCK DIMENSIONS (INCHES) D50 = 18" 70-100 30 50-70 24 35-50 18 2-10 6 NOTES: 1.STREAMBED MATERIAL SHALL HAVE D50 OF 18". STREAMBED MATERIAL SHALL INCLUDE MAXIMUM 20% FINES. FINES ARE CONSIDERED SMALLER COBBLE, GRAVEL AND SAND THAT CONSTITUTE A TYPICAL STREAM SUBSTRATE. 2.WHERE AVAILABLE, STREAMBED MATERIAL SHALL BE SALVAGED FROM EXISTING CHANNEL AND STOCKPILED ON SITE TO BE INSTALLED WITHIN THE BASEFLOW CHANNEL, AS SHOWN ON THE PLANS. 3.ADDITIONAL STREAMBED MATERIAL TO BE ACQUIRED AT LOCAL QUARRY AS PIT RUN WITH COBBLE AND FINES. 4.OFFSITE MATERIAL WILL BE REQUIRED TO SUPPLEMENT ONSITE STREAMBED MATERIAL. FINAL GRADATION OF STREAMBED MATERIAL SHALL GENERALLY MEET THAT OUTLINED IN THE TABLE SHOWN ON THIS SHEET AND BE APPROVED BY THE ENGINEER PRIOR TO PLACEMENT. 5.AFTER PLACEMENT OF STREAMBED MATERIAL WITHIN THE ACTIVE CHANNEL, CONTRACTOR SHALL WASH IN FINES OF STREAMBED MATERIAL TO CREATE AN INTERLOCKING MASS OF ROCK THAT IS CLEAR OF FINES AT SURFACE FINISHED GRADE. 6.STREAM SUBSTRATE MATERIAL SHALL BE PLACED TO PROVIDE NATURAL SURFACE VARIABILITY AND ROUGHNESS WITHIN THE STREAM CHANNEL. TOE WALL WINGWALL WINGWALL 2-FOOT THICK VOID-FILLED RIPRAP (D50 = 12") OUTLET PROTECTION WINGWALL WINGWALL LENGTH 1.0' WINGWALL WINGWALL 135° TYP. 2-FOOT THICK VOID-FILLED RIPRAP (D50 = 12") OUTLET PROTECTION PARSHALL FLUME PLAN PARSHALL FLUME SECTION FLOW FLOW A 1'1' W THROAT WIDTH 6' E G 5.00'D N Y K C T B HB POINT OF MEASUREMENT POINT OF MEASUREMENT (POM) CUTOFF WALL TO EXTEND 0.5' BELOW EXISTING GRADE 1' SUBGRADE WINGWALL 2' T PARSHALL FLUME MASTER DIMENTIONS SIZE (W)A POM B C D E T G K N X Y 1'-6"4'-9"3'-2"4'-7 7/8"2'-6"3 '- 4 3/8"1'-6"2'-0"3'-0"0'-3"0'-9"0'-2"0'-3" 2'-0"5'-0"3'-4"4'-10 7/8"3'-0"3'-11 1/2"2'-0"2'-0"3'-0"0'-3"0'-9"0'-2"0'-3" 3'-0"5'-6"3'-8"5'-4 3/4"4'-0"5'-1 7/8"3'-0"2'-0"3'-0"0'-3"0'-9"0'-2"0'-3" 4'-0"6'-0"4'5'-10 5/8"5'-0"6'-4 1/4"4'-0"2'-0"3'-0"0'-3"0'-9"0'-2"0'-3" TYPICAL DETAILS 211-020.020 ---- DT03 JBH/DTL JBH/DTL SDS 4/26/2024 SHOWN MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 3-BUSINESS DAYS IN ADVANCE CENTER OF COLORADO OR CALL UTILITY NOTIFICATION 1-800-922-1987 811 CALL COLORADO NO.BY DATE COMMENTS SCALE DETAIL CHECK DESIGN Pl o t D a t e / T i m e : 0 4 / 2 5 / 2 0 2 4 , 0 8 : 3 3 : 2 4 P M ; G : \ W W E \ 2 1 1 - 0 2 0 \ 0 2 0 \ C A D \ 0 2 _ D W G S \ D T X X - T Y P D E T A I L S . D W G - 2 - D T 0 3 T Y P I C A L D E T A I L S SHEET NO. JOB NO. REVISION NO. DATE DESCRIPTIONWRIGHT WATER ENGINEERS, INC. GLENWOOD SPRINGS, CO 81602 (970)945-7755 FAX(970)945-9210 818 COLORADO AVE. P.O. BOX 219 DRAFT NOT FOR CONSTRUCTION BID SET 4/26/2024 4/26/2024 COMBINE RYDEN NO. 2 AND BENSON PIERSON NELSON DIVERSIONS FRESNO SERIES 8200 FABRICATED SLIDE GATES FRONT ISOMETRIC VIEW BACK ISOMETRIC VIEW NOTES: 1.CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR HEADAGTES FOR ENGINEERS REVIEW. 2.HEADGATES TO BE CONSTRUCTED OF ALUMINUM. 3.HEADGATES TO BE FRESNO SERIES 8200. 4.HEADGATES AT DIVERSION STRUCTURE HAVE DIFFERENT INVERTS, BUT SHALL HAVE SAME HANDLE AND TOP OF FRAME ELEVATIONS TO PROVIDE AESTHETIC SYMMETRY. 5.HEADGATES SHALL INCLUDE LOCKING BAR MECHANISM. 6.CONTRACTOR SHALL COORDINATE HEADAGET INSTALLATION WITH HYDRLOGIK, INC AS IT RELATES TO ACTUATORS, TELEMETRY AND WIRING. 7.HEADGATES SHALL BE BOLTED INTO CONCRETE, NOT PIPE. 8.HEADGATES SHALL BE WATER TIGHT. HEADGATE LOCATION AND TYPE: 1.DIVERSION (30" HDPE PIPE): 36" X 36" 2.SEDIMENT SLUICE: 24"X24" 3.SPLITTER STRUCTURE (2 TOTAL): 30"X30" THRUST BLOCKS NOTES: 1.THRUST BLOCKS SHALL BE SIZED AND PLACED IN ACCORDANCE WITH SPECIFICATION SECTION 32 80 00. 2.DETAILS ORIGINATED IN JULY 2021 BY DENVER WATER. PARSHALL FLUME AND CUTOFF WALL DETAIL NTS NOTES: 1.MINOR GRADING MIGHT BE REQUIRED AT INLET AND OUTLET TO PROVIDE TRANSITION INTO AND OUT OF THE FLUME. TYPICAL BURIAL DEPTH BETWEEN 10' & 15'. FOR HEIGHTS GREATER THAN 15' OR WHERE GROUNDWATER WILL BE ENCOUNTERED, PLEASE CONTACT ADS ENGINEERING 12" MIN FROM HP BASIN OUTSIDE WALL 6" MIN BELOW HP BASIN WELDED BOTTOM BEDDING THICKNESS MUST BE SPECIFIED BY DESIGN ENGINEER TO BE ADEQUATE SUPPORT FOR LOADING AND SOIL CONDITIONS, BUT NOT LESS THAN 6" (150MM) VARIES, 6" (150MM) MINIMUM 18" MINIMUM WIDTH OF BACKFILL CLASS I BACKFILL & BEDDING, PER ASTM D2321, MATERIAL SHALL BE WELL PLACED UNIFORMILY AROUND STRUCTURE AND INLET CONNECTIONS AND COMPACTED IN 8" MAX LIFTS 12" - 36" HP PIPE STUB 4" - 10" INSERTA-TEE (NOT SHOWN) SPECIFY DIAMETER, LOCATION & CONNECTION TYPE 48" ADS TRIPLE WALL POLYPROPYLENE RISER MIN. AS SPECIFIED BY OTHERS, BUT NOT LESS THAN 18" (450mm) MIN. AS SPECIFIED BY OTHERS, BUT NOT LESS THAN 8" (200mm) CONCRETE SLAB DIMENSIONS ARE FOR GUIDELINE PURPOSES ONLY. ACTUAL CONCRETE SLAB MUST BE DESIGNED TAKING INTO CONSIDERATION LOCAL SOIL CONDITIONS, TRAFFIC LOADING, & OTHER APPLICABLE DESIGN FACTORS. FRAME AND GRATE (BY OTHERS). RISER OD SHALL BE 32.0" (813mm) ASPHALT OR TURF LID & FRAME SUPPLIED BY ADS FOR LOADS NOT TO EXCEED HL-93; SEE STD-414 FOR FURTHER DETAILS OF FRAME & COVER. ALTERNATE LID & FRAME BY OTHERS AS ALLOWED PER DESIGN ENGINEER. FRAME TO BE SUPPORTED BY CONCRETE COLLAR. CONCRETE FOOTING DIMENSIONS ARE FOR GUIDELINE PURPOSES ONLY. ACTUAL CONCRETE SLAB MUST BE DESIGNED TAKING INTO CONSIDERATION LOCAL SOIL CONDITIONS & OTHER APPLICABLE DESIGN FACTORS. NOTES: 1 - GRATES/SOLID COVER SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05. 2 - FRAMES & REDUCING PLATE SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05. 3 - 48" HP DRAIN BASINS ARE TO BE CUSTOM MANUFACTURED ACCORDING TO PLAN DETAILS. 4 - ADAPTERS CAN BE MOUNTED ON ANGLES 0° TO 359°. TO DETERMINE MINIMUM ANGLE BETWEEN ADAPTERS SEE DRAWING NO. 7009-110-026 5 - FOR BURIAL DEPTHS GREATER THAN 15', OR WHERE GROUND WATER WILL BE ENCOUNTERED, CONTACT ADS ENGINEERING. 6 - AVOID CONSTRUCTION LOADING ON REDUCING PLATE AND STRUCTURE PRIOR TO CONCRETE COLLAR INSTALLATION. BUTYL SEALANT RECOMMENDED 30-INCH HDPE PIPE 30" x 18" DUEL WALL FABRICATED REDUCING TEE WITH WATER TIGHT JOINT PROPOSED GRADE 3.46' NON-PRESSURE PIPE END PLUG WITH GASKETS 1.00' MIN. 2.07'COMPACTED SUBGRADE NOTES: 1.TYPICAL DETAIL DEVELOPED USING ADS PRODUCT CATALOG AND TEES FITTING MANUAL, PRODUCT CODE 1833AA AND 3066AN65N. TYPICAL DETAILS 211-020.020 ---- DT04 JBH/DTL JBH/DTL SDS 4/26/2024 SHOWN MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 3-BUSINESS DAYS IN ADVANCE CENTER OF COLORADO OR CALL UTILITY NOTIFICATION 1-800-922-1987 811 CALL COLORADO NO.BY DATE COMMENTS SCALE DETAIL CHECK DESIGN Pl o t D a t e / T i m e : 0 4 / 2 5 / 2 0 2 4 , 0 8 : 3 3 : 2 8 P M ; G : \ W W E \ 2 1 1 - 0 2 0 \ 0 2 0 \ C A D \ 0 2 _ D W G S \ D T X X - T Y P D E T A I L S . D W G - 2 - D T 0 4 T Y P I C A L D E T A I L S SHEET NO. JOB NO. REVISION NO. DATE DESCRIPTIONWRIGHT WATER ENGINEERS, INC. GLENWOOD SPRINGS, CO 81602 (970)945-7755 FAX(970)945-9210 818 COLORADO AVE. P.O. BOX 219 DRAFT NOT FOR CONSTRUCTION BID SET 4/26/2024 4/26/2024 COMBINE RYDEN NO. 2 AND BENSON PIERSON NELSON DIVERSIONS 48" HP MANHOLE INSTALLATION DETAIL NOTES: 1.TYPICAL DETAIL PROVIDED BY ADS. 2.CONCRETE WILL NOT BE USED ON THE MANHOLE COVER. TRENCH INSTALLATION DETAIL (N-12 PER AASHTO) NOTES: 1.TYPICAL DETAIL PROVIDED BY ADS. 2.BEDDING MAY NOT BE REQUIRED, CONTRACTOR TO COORDINATE WITH ENGINEER. CLEANOUT DETAIL A A SECTION A-A 2.7' 1.44' ADS 48" HP MANHOLE 30-INCH HDPE PIPE 12-INCH HDPE PIPE EXISTING GRADE PROPOSED GRADE FRESNO SERIES 6400 16" SLIDE GATE PROPOSED GRADE FRESNO SERIES 6400 16" SLIDE GATE 2' COVER (MIN.) COUNTY ROAD 243 APPROXIMATE ASPHALT WIDTH 22' 30-INCH HDPE PIPE PROPOSED GRADE PROPOSED GRADE EXISTING GRADE FLARED END SECTION WITH TRASH GUARD CONTRACTOR TO REPLACE EXISTING ASPHALT PER GARFIELD COUNTY STANDARDS TYPICAL DETAILS 211-020.020 ---- DT05 JBH/DTL JBH/DTL SDS 4/26/2024 SHOWN MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 3-BUSINESS DAYS IN ADVANCE CENTER OF COLORADO OR CALL UTILITY NOTIFICATION 1-800-922-1987 811 CALL COLORADO NO.BY DATE COMMENTS SCALE DETAIL CHECK DESIGN Pl o t D a t e / T i m e : 0 4 / 2 5 / 2 0 2 4 , 0 8 : 3 3 : 2 9 P M ; G : \ W W E \ 2 1 1 - 0 2 0 \ 0 2 0 \ C A D \ 0 2 _ D W G S \ D T X X - T Y P D E T A I L S . D W G - 2 - D T 0 5 T Y P I C A L D E T A I L S SHEET NO. JOB NO. REVISION NO. DATE DESCRIPTIONWRIGHT WATER ENGINEERS, INC. GLENWOOD SPRINGS, CO 81602 (970)945-7755 FAX(970)945-9210 818 COLORADO AVE. P.O. BOX 219 DRAFT NOT FOR CONSTRUCTION BID SET 4/26/2024 4/26/2024 COMBINE RYDEN NO. 2 AND BENSON PIERSON NELSON DIVERSIONS TURNOUT DETAIL ROAD CROSSING DETAIL NOTES: 1.SPIGOT BACK WILL BE UTILIZED FOR MOUNTING DIRECTLY TO THE CORRUGATED METAL PIPE. FRESNO 6400 HEADGATE DETAIL NOTES: 1.CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR HEADAGTES FOR ENGINEERS REVIEW. 2.HEADGATES TO BE CONSTRUCTED OF ALUMINUM. 3.HEADGATES TO BE FRESNO SERIES 6400. 4.HEADGATES SHALL INCLUDE LOCKING BAR MECHANISM. 5.CONTRACTOR SHALL COORDINATE HEADAGET INSTALLATION WITH HYDRLOGIK, INC AS IT RELATES TO ACTUATORS, TELEMETRY AND WIRING. 6.HEADGATES SHALL BE BOLTED DIRECTLY TO PIPE. 7.HEADGATES SHALL BE WATER TIGHT. TYPICAL DETAILS 211-020.020 ---- DT06 JBH/DTL JBH/DTL SDS 4/26/2024 SHOWN MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 3-BUSINESS DAYS IN ADVANCE CENTER OF COLORADO OR CALL UTILITY NOTIFICATION 1-800-922-1987 811 CALL COLORADO NO.BY DATE COMMENTS SCALE DETAIL CHECK DESIGN Pl o t D a t e / T i m e : 0 4 / 2 5 / 2 0 2 4 , 0 8 : 3 3 : 3 4 P M ; G : \ W W E \ 2 1 1 - 0 2 0 \ 0 2 0 \ C A D \ 0 2 _ D W G S \ D T X X - T Y P D E T A I L S . D W G - 2 - D T 0 6 T Y P I C A L D E T A I L S SHEET NO. JOB NO. REVISION NO. DATE DESCRIPTIONWRIGHT WATER ENGINEERS, INC. GLENWOOD SPRINGS, CO 81602 (970)945-7755 FAX(970)945-9210 818 COLORADO AVE. P.O. BOX 219 DRAFT NOT FOR CONSTRUCTION BID SET 4/26/2024 4/26/2024 COMBINE RYDEN NO. 2 AND BENSON PIERSON NELSON DIVERSIONS TYPICAL DETAILS 211-020.020 ---- DT07 JBH/DTL JBH/DTL SDS 4/26/2024 SHOWN MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 3-BUSINESS DAYS IN ADVANCE CENTER OF COLORADO OR CALL UTILITY NOTIFICATION 1-800-922-1987 811 CALL COLORADO NO.BY DATE COMMENTS SCALE DETAIL CHECK DESIGN Pl o t D a t e / T i m e : 0 4 / 2 5 / 2 0 2 4 , 0 8 : 3 3 : 4 1 P M ; G : \ W W E \ 2 1 1 - 0 2 0 \ 0 2 0 \ C A D \ 0 2 _ D W G S \ D T X X - T Y P D E T A I L S . D W G - 2 - D T 0 7 T Y P I C A L D E T A I L S SHEET NO. JOB NO. REVISION NO. DATE DESCRIPTIONWRIGHT WATER ENGINEERS, INC. GLENWOOD SPRINGS, CO 81602 (970)945-7755 FAX(970)945-9210 818 COLORADO AVE. P.O. BOX 219 DRAFT NOT FOR CONSTRUCTION BID SET 4/26/2024 4/26/2024 COMBINE RYDEN NO. 2 AND BENSON PIERSON NELSON DIVERSIONS STANDARD END SECTION FOR HDPE PIPES NOTES: 1.TYPICAL DETAIL PROVIDED BY ADS. TRASH GUARDS FOR HDPE END SECTIONS NOTES: 1.TYPICAL DETAIL PROVIDED BY ADS. 2.DETAILS SHOWN ARE INTENT OF TRASH GUARD. CONTRACTOR TO PROVIDE SHOP DRAWINGS OF TRASH GUARD. 3.TRASH GUARD SHALL BE METAL. TRASH GUARD SHALL BE HINGED OR EASILY REMOVABLE. PLACE COIR MAT OVER STRAW, PLACED AT 2000 LB/AC. SEED AREA PRIOR TO PLACING STRAW.CONTINUE BLANKET THROUGH BANKFULL CHANNEL ANCHOR COIR MAT WITH 2"x4" WOODEN STAKES @ 24" O.C. (SEE TRENCH C DETAIL) ANCHOR COIR MAT WITH 2"x4" WOODEN STAKES @ 24" O.C. (SEE TRENCH C DETAIL) EROSION CONTROL BLANKET (AS NOTED), 6.5' OR 13' WIDE ROLL. TRIM AS NECESSARY TO END AT LIMITS SHOWN ON PLAN VIEWS. ANCHOR COIR MAT WITH 2"x4" WOODEN STAKES @ 24" O.C. (SEE TRENCH B DETAIL) 2"x4" STAKE (TYP.) COMPACTED BACKFILL (TYP.) 6" EROSION CONTROL BLANKET, TYP. 12" MIN. 6" MIN. EROSION CONTROL BLANKET INSTALLATION NOTES: 1.ALL DISTURBED AREAS TO BE REVEGETATED TO THEIR NATIVE CONDITION OUTSIDE OF BANKFULL CHANNEL. 2.EROSION CONTROL FABRIC (AS SPECIFIED ON THIS PLAN) SHALL BE PLACED ATOP STRAW UNDERLAYMENT AND SEEDED WITH TOPSOIL. EROSION CONTROL BLANKET PATTERN STAKING SHOULD BE CONSISTENT WITH SUPPLIER RECOMMENDATIONS AND COMPLETED IN A MANNER SUCH THAT THE BLANKET IS FLUSH AGAINST EACH GRADE BREAK. EROSION CONTROL BLANKET MAINTENANCE NOTES 1.INSPECT BMP'S EACH WORKDAY, AND MAINTAIN THEM IN EFFECTIVE OPERATING CONDITION. MAINTENANCE OF BMP'S SHOULD BE PROACTIVE, NOT REACTIVE. INSPECT BMP'S AS SOON AS POSSIBLE (AND ALWAYS WITHIN 24 HOURS) FOLLOWING A STORM THAT CAUSES SURFACE EROSION, AND PERFORM NECESSARY MAINTENANCE. 2.FREQUENT OBSERVATIONS AND MAINTENANCE ARE NECESSARY TO MAINTAIN BMP'S IN EFFECTIVE OPERATING CONDITION. INSPECTIONS AND CORRECTIVE MEASURES SHOULD BE DOCUMENTED THOROUGHLY. 3.WHERE BMP'S HAVE FAILED, REPAIR OR REPLACEMENT SHOULD BE INITIATED UPON DISCOVERY OF THE FAILURE. 4.ECB'S SHALL BE LEFT IN PLACE TO EVENTUALLY BIODEGRADE, UNLESS REQUESTED TO BE REMOVED BY THE LOCAL JURISDICTION. 5.ANY ECB PULLED OUT, TORN, OR OTHERWISE DAMAGED SHALL BE REPAIRED OR REINSTALLED. ANY SUBGRADE AREAS BELOW THE EROSION CONTROL BLANKET THAT HAVE ERODED TO CREATE A VOID UNDER THE BLANKET, OR THAT REMAIN DEVOID OF GRASS SHALL BE REPAIRED, RESEEDED AND MULCHED AND ECB REINSTALLED. EROSION CONTROL BLANKET PLACEMENT DETAIL NOT TO SCALE ANCHOR TRENCH FOR EROSION CONTROL BLANKET NOT TO SCALE ECB REVEGETATION NOTES: 1.ALL DISTURBED AREAS TO BE REVEGETATED IN COORDINATION WITH ENGINEER. 2.ALL REVEGETATED AREA'S TO BE RESEEDED WITHOUT AN EROSION CONTROL BLANKET MUST INCLUDE TOPSOIL, MULCH, AND STRAW CRIMPING. 3.AREAS WITHIN THE RIPARIAN AREA BUT OUTSIDE OF THE ACTIVE CHANNEL WILL BE REVEGETATED WITH TOPSOIL AND AN UPLAND SEED MIX, PASTURE SEED MIX OR RIPARIAN SEED MIX APPLICABLE TO THE AREA AND THEN COVERED WITH EROSION CONTROL BLANKET, IF SPECIFIED, OR ADD MULCHING IN CONJUNCTION WITH STRAW CRIMPING. 4.AREAS OUTSIDE OF THE RIPARIAN AREA, SUCH AS STAGING AND ACCESS AREAS, TO BE REVEGETATED TO ORIGINAL CONDITION. 5.CONTRACTOR SHALL PROVIDE A 2-YEAR, 70% COVER WARRANTY ON ALL REVEGETATION COMPONENTS. MAKE 45° ANGLED CUT AT BUTT-END, PLANT BUTT-END DOWN 1 4 " - 1 2 " DIAMETER STAKE PLACED IN HOLE. WATER TABLE TRIM BRANCHES CLOSE CUT TOP OF STAKE SQUARE PLACE WILLOW STAKES 3' O.C. (1 PER HOLE) BACKFILL WITH A THICK MUD / WATER SLURRY TO PREVENT FORMATION OF AIR POCKETS. EXTEND COBBLE 24" MIN. OUTSIDE OF CHANNEL 2X SUBSTRATE D50 MIN. (TYP.) STAKE 1'-3' O.C. BOULDER SEE PLAN FOR SIZEWATER TABLE EX. SUBGRADE TO REMAIN PLACE ENDS OF WILLOW STAKES 6" MIN. INTO THE SEASONALLY SATURATED ZONE DRIVE OR PLANT WILLOW STAKES THROUGH OPENINGS IN COBBLE STREAM SUBSTRATE JBH/DTL JBH/DTL SDS 4/26/2024 SHOWN MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 3-BUSINESS DAYS IN ADVANCE CENTER OF COLORADO OR CALL UTILITY NOTIFICATION 1-800-922-1987 811 CALL COLORADO NO.BY DATE COMMENTS SCALE DETAIL CHECK DESIGN Pl o t D a t e / T i m e : 0 4 / 2 5 / 2 0 2 4 , 0 8 : 3 4 : 0 6 P M ; G : \ W W E \ 2 1 1 - 0 2 0 \ 0 2 0 \ C A D \ 0 2 _ D W G S \ D T X X - S W M P D E T A I L S . D W G - 2 - D T 0 8 - S W M P SHEET NO. JOB NO. REVISION NO. DATE DESCRIPTIONWRIGHT WATER ENGINEERS, INC. GLENWOOD SPRINGS, CO 81602 (970)945-7755 FAX(970)945-9210 818 COLORADO AVE. P.O. BOX 219 DRAFT NOT FOR CONSTRUCTION BID SET 4/26/2024 4/26/2024 SWMP DETAILS 211-020.020 ---- COMBINE RYDEN NO. 2 AND BENSON PIERSON NELSON DIVERSIONS WILLOW NOTES: 1.INTEGRATE STAKE PLANTING TECHNIQUES DURING ROCK PLACEMENT TO ENSURE CONTACT WITH NATIVE GROUND. 2.PLACE SOIL FILL AROUND CUTTINGS AND 'WATER IN'. 3.2 STAKES PER LINEAR FOOT. 4.CONTRACTOR SHALL WATER IN INITIALLY DURING IMPLEMENTATION. 5.WILLOWS SHALL BE HARVESTED WHILE DORMANT AND STORED IN PROPER CONDITIONS UNTIL PLACEMENT. 6.WILLOWS CAN BE HARVESTED ONSITE IN COORDINATION WITH ENGINEER. WILLOW PLANTING DETAIL TYPICAL STAKE DETAIL NTS WILLOW PLANTING BANK PLACEMENT NTS 6" MIN DT08 STABILIZED CONSTRUCTION ENTRANCE/EXIT INSTALLATION NOTES 1. SEE PLAN VIEW FOR -LOCATION OF CONSTRUCTION ENTRANCE(S)/EXIT(S). -TYPE OF CONSTRUCTION ENTRANCE(S)/EXITS(S) (WITH/WITHOUT WHEEL WASH, CONSTRUCTION MAT OR TRM). 2. CONSTRUCTION MAT OR TRM STABILIZED CONSTRUCTION ENTRANCES ARE ONLY TO BE USED ON SHORT DURATION PROJECTS (TYPICALLY RANGING FROM A WEEK TO A MONTH) WHERE THERE WILL BE LIMITED VEHICULAR ACCESS. 3. A STABILIZED CONSTRUCTION ENTRANCE/EXIT SHALL BE LOCATED AT ALL ACCESS POINTS WHERE VEHICLES ACCESS THE CONSTRUCTION SITE FROM PAVED RIGHT-OF-WAYS. 4. STABILIZED CONSTRUCTION ENTRANCE/EXIT SHALL BE INSTALLED PRIOR TO ANY LAND DISTURBING ACTIVITIES. 5. A NON-WOVEN GEOTEXTILE FABRIC SHALL BE PLACED UNDER THE STABILIZED CONSTRUCTION ENTRANCE/EXIT PRIOR TO THE PLACEMENT OF ROCK. 6. UNLESS OTHERWISE SPECIFIED BY LOCAL JURISDICTION, ROCK SHALL CONSIST OF DOT SECT. #703, AASHTO #3 COARSE AGGREGATE OR 6" (MINUS) ROCK. STABILIZED CONSTRUCTION ENTRANCE/EXIT MAINTENANCE NOTES 1. INSPECT BMPs EACH WORKDAY, AND MAINTAIN THEM IN EFFECTIVE OPERATING CONDITION. MAINTENANCE OF BMPs SHOULD BE PROACTIVE, NOT REACTIVE. INSPECT BMPs AS SOON AS POSSIBLE (AND ALWAYS WITHIN 24 HOURS) FOLLOWING A STORM THAT CAUSES SURFACE EROSION, AND PERFORM NECESSARY MAINTENANCE. 2. FREQUENT OBSERVATIONS AND MAINTENANCE ARE NECESSARY TO MAINTAIN BMPs IN EFFECTIVE OPERATING CONDITION. INSPECTIONS AND CORRECTIVE MEASURES SHOULD BE DOCUMENTED THOROUGHLY. 3. WHERE BMPs HAVE FAILED, REPAIR OR REPLACEMENT SHOULD BE INITIATED UPON DISCOVERY OF THE FAILURE. 4. ROCK SHALL BE REAPPLIED OR REGRADED AS NECESSARY TO THE STABILIZED ENTRANCE/EXIT TO MAINTAIN A CONSISTENT DEPTH. 5. SEDIMENT TRACKED ONTO PAVED ROADS IS TO BE REMOVED THROUGHOUT THE DAY AND AT THE END OF THE DAY BY SHOVELING OR SWEEPING. SEDIMENT MAY NOT BE WASHED DOWN STORM SEWER DRAINS. NOTE: MANY JURISDICTIONS HAVE BMP DETAILS THAT VARY FROM UDFCD STANDARD DETAILS. CONSULT WITH LOCAL JURISDICTIONS AS TO WHICH DETAIL SHOULD BE USED WHEN DIFFERENCES ARE NOTED. (DETAILS ADAPTED FROM CITY OF BROOMFIELD, COLORADO, NOT AVAILABLE IN AUTOCAD) UNLESS OTHERWISE SPECIFIED BY LOCAL JURISDICTION, USE CDOT SECT. #703, AASHTO #3 COARSE AGGREGATE OR 6" MINUS ROCK NON-WOVEN GEOTEXTILE FABRIC BETWEEN SOIL AND ROCK SIDEWALK OR OTHER PAVED SURFACE 50 FOOT (MIN.) 20 FOOT (WIDTH CAN BE LESS IF CONST. VEHICLES ARE PHYSICALLY CONFINED ON BOTH SIDES) UNLESS OTHERWISE SPECIFIED BY LOCAL JURISDICTION, USE CDOT SECT. #703, AASHTO #3 COARSE AGGREGATE OR 6" MINUS ROCK PUBLIC ROADWAY 9" (MIN.) A VTC-1. AGGREGATE VEHICLE TRACKING CONTROL SECTION A INSTALL ROCK FLUSH WITH OR BELOW TOP OF PAVEMENT NON-WOVEN GEOTEXTILE FABRIC COMPACTED SUBGRADE 9" (MIN.) STABILIZED CONSTRUCTION ENTRANCE (SEE DETAILS VTC-1 TO VTC-3) CONSTRUCTION TRAILERS 3" MIN. THICKNESS GRANULAR MATERIAL EXISTING ROADWAY STABILIZED STAGING AREA INSTALLATION NOTES 1. SEE PLAN VIEW FOR -LOCATION OF STAGING AREA(S). -CONTRACTOR MAY ADJUST LOCATION AND SIZE OF STAGING AREA WITH APPROVAL FROM THE LOCAL JURISDICTION. 2. STABILIZED STAGING AREA SHOULD BE APPROPRIATE FOR THE NEEDS OF THE SITE. OVERSIZING RESULTS IN A LARGER AREA TO STABILIZE FOLLOWING CONSTRUCTION. 3. STAGING AREA SHALL BE STABILIZED PRIOR TO OTHER OPERATIONS ON THE SITE. 4. THE STABILIZED STAGING AREA SHALL CONSIST OF A MINIMUM 3" THICK GRANULAR MATERIAL. 5. UNLESS OTHERWISE SPECIFIED BY LOCAL JURISDICTION, ROCK SHALL CONSIST OF DOT SECT. #703, AASHTO #3 COARSE AGGREGATE OR 6" (MINUS) ROCK. 6. ADDITIONAL PERIMETER BMPs MAY BE REQUIRED INCLUDING BUT NOT LIMITED TO SILT FENCE AND CONSTRUCTION FENCING. STABILIZED STAGING AREA MAINTENANCE NOTES 1. INSPECT BMPs EACH WORKDAY, AND MAINTAIN THEM IN EFFECTIVE OPERATING CONDITION. MAINTENANCE OF BMPs SHOULD BE PROACTIVE, NOT REACTIVE. INSPECT BMPs AS SOON AS POSSIBLE (AND ALWAYS WITHIN 24 HOURS) FOLLOWING A STORM THAT CAUSES SURFACE EROSION, AND PERFORM NECESSARY MAINTENANCE. 2. FREQUENT OBSERVATIONS AND MAINTENANCE ARE NECESSARY TO MAINTAIN BMPs IN EFFECTIVE OPERATING CONDITION. INSPECTIONS AND CORRECTIVE MEASURES SHOULD BE DOCUMENTED THOROUGHLY. 3. WHERE BMPs HAVE FAILED, REPAIR OR REPLACEMENT SHOULD BE INITIATED UPON DISCOVERY OF THE FAILURE. 4. ROCK SHALL BE REAPPLIED OR REGRADED AS NECESSARY IF RUTTING OCCURS OR UNDERLYING SUBGRADE BECOMES EXPOSED. CONSTRUCTION SITE ACCESS SSA-1. STABILIZED STAGING AREA STABILIZED STAGING AREA MAINTENANCE NOTES 5. STABILIZED STAGING AREA SHALL BE ENLARGED IF NECESSARY TO CONTAIN PARKING, STORAGE, AND UNLOADING/LOADING OPERATIONS. 6. THE STABILIZED STAGING AREA SHALL BE REMOVED AT THE END OF CONSTRUCTION. THE GRANULAR MATERIAL SHALL BE REMOVED OR, IF APPROVED BY THE LOCAL JURISDICTION, USED ON SITE, AND THE AREA COVERED WITH TOPSOIL, SEEDED AND MULCHED OR OTHERWISE STABILIZED IN A MANNER APPROVED BY LOCAL JURISDICTION. NOTE: MANY MUNICIPALITIES PROHIBIT THE USE OF RECYCLED CONCRETE AS GRANULAR MATERIAL FOR STABILIZED STAGING AREAS DUE TO DIFFICULTIES WITH RE-ESTABLISHMENT OF VEGETATION IN AREAS WHERE RECYCLED CONCRETE WAS PLACED. NOTE: MANY JURISDICTIONS HAVE BMP DETAILS THAT VARY FROM UDFCD STANDARD DETAILS. CONSULT WITH LOCAL JURISDICTIONS AS TO WHICH DETAIL SHOULD BE USED WHEN DIFFERENCES ARE NOTED. (DETAILS ADAPTED FROM DOUGLAS COUNTY, COLORADO, NOT AVAILABLE IN AUTOCAD) SF/CF SF/CF SF/CF SF/CF SF / C F S F / C F SF / C F SILT FENCE OR CONSTRUCTION FENCING AS NEEDED ONSITE CONSTRUCTION VEHICLE PARKING (IF NEEDED) MATERIAL STORAGE AREA LENGTH, L CREST LENGTH, CL SECTION A 1' 6" (MIN) D (1' 6" MIN") CHANNEL GRADE UPSTREAM AND DOWNSTREAM TOP OF CHECK DAM SECTION B (TYP.) A B COMPACTED BACKFILL, (TYP.) 6' 2' 1' 6" MIN. 1' MIN. CHANNEL GRADE EXCAVATION TO NEAT LINE, AVOID OVER-EXCAVATION, (TYP.) 8' 1' MIN. CHANNEL GRADE EXCAVATION TO NEAT LINE, AVOID OVER-EXCAVATION (TYP.) 2 1 D50 = 12" RIPRAP, TYPE M OR TYPE L D50=9" (SEE TABLE MD-7, MAJOR DRAINAGE, VOL. 1 FOR GRADATION) D50 = 12" RIPRAP, TYPE M OR TYPE L D50= 9" (SEE TABLE MD-7, MAJOR DRAINAGE, VOL. 1 FOR GRADATION) FLOW FLOW A B SPACING BETWEEN CHECK DAMS SUCH THAT A AND B ARE EQUAL ELEVATION CHANNEL GRADE CHECK DAM ELEVATION VIEW SECTION A SECTION B CD-1. CHECK DAM PROFILE SSA VTC CD JBH/DTL JBH/DTL SDS 4/26/2024 SHOWN MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 3-BUSINESS DAYS IN ADVANCE CENTER OF COLORADO OR CALL UTILITY NOTIFICATION 1-800-922-1987 811 CALL COLORADO NO.BY DATE COMMENTS SCALE DETAIL CHECK DESIGN Pl o t D a t e / T i m e : 0 4 / 2 5 / 2 0 2 4 , 0 8 : 3 4 : 0 8 P M ; G : \ W W E \ 2 1 1 - 0 2 0 \ 0 2 0 \ C A D \ 0 2 _ D W G S \ D T X X - S W M P D E T A I L S . D W G - 2 - D T 0 9 - S W M P SHEET NO. JOB NO. REVISION NO. DATE DESCRIPTIONWRIGHT WATER ENGINEERS, INC. GLENWOOD SPRINGS, CO 81602 (970)945-7755 FAX(970)945-9210 818 COLORADO AVE. P.O. BOX 219 DRAFT NOT FOR CONSTRUCTION BID SET 4/26/2024 4/26/2024 SWMP DETAILS 211-020.020 ---- DT09 COMBINE RYDEN NO. 2 AND BENSON PIERSON NELSON DIVERSIONS JBH/DTL JBH/DTL SDS 4/26/2024 SHOWN MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 3-BUSINESS DAYS IN ADVANCE CENTER OF COLORADO OR CALL UTILITY NOTIFICATION 1-800-922-1987 811 CALL COLORADO NO.BY DATE COMMENTS SCALE DETAIL CHECK DESIGN Pl o t D a t e / T i m e : 0 4 / 2 5 / 2 0 2 4 , 0 8 : 3 4 : 1 0 P M ; G : \ W W E \ 2 1 1 - 0 2 0 \ 0 2 0 \ C A D \ 0 2 _ D W G S \ D T X X - S W M P D E T A I L S . D W G - 2 - D T 1 0 - S W M P SHEET NO. JOB NO. REVISION NO. DATE DESCRIPTIONWRIGHT WATER ENGINEERS, INC. GLENWOOD SPRINGS, CO 81602 (970)945-7755 FAX(970)945-9210 818 COLORADO AVE. P.O. BOX 219 DRAFT NOT FOR CONSTRUCTION BID SET 4/26/2024 4/26/2024 SWMP DETAILS 211-020.020 ---- DT10 COMBINE RYDEN NO. 2 AND BENSON PIERSON NELSON DIVERSIONS ConsultantsGEI GEI CONSULTANTS, INC. Enter office contact information in the type propterties Attention: If this scale bar does not measure 1" then drawing is not original scale. 0 1" SHEET NO.SHEET NAMEDesigned: Drawn: Checked: Approved: P.E. No: GEI Project 4/ 2 6 / 2 0 2 4 4 : 3 2 : 3 6 P M C : \ U s e r s \ P u b l i c \ D o c u m e n t s \ A u t o d es k \ 2 0 2 4 R e v i t P r o j e c t s \ M C A C P R O J 2 R E V _ b m a r t i n 5 2 Q Y 3 . rv t WRIGHT WATER ENGINEERS 818 COLORADO AVE. GLENWOOD SPRINGS, CO 81602 MCAC FISH PASSAGE DIVERSION GARFIELD COUNTY, COLORADO2303806 S-01 Enter PE No Approver K. DEBELEN Checker K. DEBELEN NOT FOR CONSTRUCTION BID SET STRUCTURAL NOTES (SHEET 1 OF 2) GENERAL STRUCTURAL AND ARCHITECTURAL NOTES 1. EXISTING STRUCTURES 1.A.CONTRACT DOCUMENTS HAVE BEEN PREPARED USING AVAILABLE DRAWINGS AND SITE OBSERVATION AS PERMITTED BY ACCESS RESTRICTIONS DURING DESIGN. 1.B.DURING CONSTRUCTION, THE CONTRACTOR MAY ENCOUNTER EXISTING CONDITIONS THAT ARE NOT NOW KNOWN OR ARE AT VARIANCE WITH PROJECT DOCUMENTATION. CONTRACTOR SHALL NOTIFY THE ENGINEER OF ALL CONDITIONS NOT PER THE CONTRACT DOCUMENTS. EXAMPLES INCLUDE: -SIZES OR DIMENSIONS OTHER THAN THOSE SHOWN. -DAMAGE OR DETERIORATION TO MATERIALS AND COMPONENTS. -CONDITIONS OF INSTABILITY OR LACK OF SUPPORT. 1.C. PREPARE DIMENSIONAL DRAWINGS OF ALL DISCOVERED ITEMS. 1.D.CONTRACTOR SHALL FIELD VERIFY ALL EXISTING STRUCTURAL CONDITIONS PRIOR TO SUBMITTING SHOP DRAWINGS. 1.E.CONTRACTOR SHALL MAKE ALLOWANCE FOR THE RESOLUTION OF SUCH DISCOVERIES IN THE CONSTRUCTION SCHEDULE. 2. USE OF DRAWINGS 2.A.DO NOT SCALE DRAWINGS. 2.B.WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, NOTES, AND SPECIFICATIONS, THE MORE STRINGENT REQUIREMENTS SHALL GOVERN. DETAILS ON DRAWINGS TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. DETAILS NOTED TYPICAL APPLY TO ALL SIMILAR CONDITIONS 3. TEMPORARY CONDITIONS 3.A.THE STRUCTURE IS DESIGNED TO FUNCTION AS A UNIT UPON COMPLETION. THE CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL TEMPORARY BRACING AND/OR SUPPORT THAT MAY BE REQUIRED AS THE RESULT OF THE CONTRACTOR'S CONSTRUCTION METHODS AND/OR SEQUENCES. 3.B.CONTRACTOR'S CONSTRUCTION AND/OR ERECTION SEQUENCES SHALL RECOGNIZE AND CONSIDER THE EFFECTS OF THERMAL MOVEMENTS OF STRUCTURAL ELEMENTS DURING THE CONSTRUCTION PERIOD. 3.C.FOUNDATION WALLS SHALL NOT BE BACKFILLED UNTIL THE SLABS-ON-GRADE ARE IN-PLACE AND REACH FULL STRENGTH UNLESS ADEQUATE BRACING IS PROVIDED. USE ONLY HAND OPERATED TOOLS FOR COMPACTION ADJACENT TO FOUNDATION WALLS. GRADE BEAMS SHALL BE BACKFILLED EVENLY ON BOTHS SIDES. 4. SUBMITTALS: 4.A. SEE SPECIFICATION SECTION 01 33 00 FOR SUBMITTAL REQUIREMENTS. 4.B. SHOP DRAWINGS: -IF THE CONTRACTOR REQUESTS A CHANGE FROM THE DRAWINGS, IT SHALL BE APPROVED BY THE ENGINEER AND DESIGNED BY THE ENGINEER OF RECORD PRIOR TO SUBMITTING SHOP DRAWINGS. VARIATION SHALL BE INDICATED ON THE SHOP DRAWINGS. CONTRACTOR SHALL COMPENSATE GEI CONSULTANTS, INC. FOR MAKING THE CHANGE. -CONSTRUCTION DOCUMENTS SHALL NOT BE REPRODUCED FOR USE IN SUBMITTALS. -ALL SHOP DRAWINGS SHALL REFERENCE THE DRAWING NUMBER AND DETAIL USED TO PREPARE THE SUBMITTAL. 5. SUBSTITUTIONS 5.A. ENGINEER'S APPROVAL SHALL BE SECURED FOR ALL SUBSTITUTIONS. 5.B. NONCONFORMANCE: NOTIFY ENGINEER OF CONDITIONS NOT CONSTRUCTED PER THE CONTRACT DOCUMENTS PRIOR TO PROCEEDING WITH CORRECTIVE WORK. SUBMIT PROPOSED REPAIR TO THE ENGINEER FOR ACCEPTANCE. 6. OSHA STANDARDS 6.A.THE STRUCTURE IS DESIGNED TO FUNCTION AS A UNIT UPON COMPLETION. NOTHING SHOWN ON THE DRAWINGS SHALL BE CONSTRUED AS ELIMINATING THE NEED FOR THE CONTRACTOR TO COMPLY WITH ALL OSHA REQUIREMENTS. 6.B.THE CONTRACTOR SHALL ADD ALL NECESSARY BOLTS, ANCHOR BOLTS, PLATES, STIFFENER PLATES, BRIDGING, BRACING, BEARING SEATS, ETC. AS WELL AS CLOSURES FOR OPENINGS. IN ADDITION, FIELD WELD ANYTHING THAT MAY BE CONSIDERED A TRIP HAZARD. 6.C.WHERE THE STRUCTURAL DRAWINGS APPEAR TO CONFLICT WITH OSHA REQUIREMENTS, THE STRUCTURAL DRAWINGS REPRESENT FINAL CONDITIONS ONLY. THE CONTRACTOR SHALL ADD ALL ERECTION FRAMING NECESSARY TO COMPLY WITH OSHA. 7. CONSTRUCTION ENGINEERING 7.A.THE STRUCTURE DEFINED ON THE CONTRACT DOCUMENTS HAS BEEN DESIGNED ONLY FOR LOADS ANTICIPATED ON THE STRUCTURE DURING ITS SERVICE LIFE. PROVIDE ALL REQUIRED ENGINEERING AND OTHER MEASURES TO ACHIEVE THE MEANS, METHODS, AND SEQUENCES OF WORK. SUCH ENGINEERING MAY INCLUDE, BUT IS NOT LIMITED TO: -LAYOUT, -DESIGN FOR FORMWORK, SHORING, AND RESHORING. -DESIGN OF CONCRETE MIXES. -DESIGN OF TEMPORARY BRACING. -SURVEYING TO VERIFY CONSTRUCTION TOLERANCES. -EVALUATION OF TEMPORARY CONSTRUCTION LOADS ON STRUCTURE DUE TO EQUIPMENT AND MATERIALS. -STRUCTURAL ENGINEERING TO RESIST ANY OTHER LOADS NOT IDENTIFIED ON DESIGN DRAWINGS. 8. COORDINATION 8.A.STRUCTURAL DRAWINGS ARE NOT STAND-ALONE DOCUMENTS AND ARE INTENDED TO BE USED IN CONJUNCTION WITH DRAWINGS FROM OTHER DISCIPLINES. THE CONTRACTOR SHALL COORDINATE ALL REQUIREMENTS OF THE CONTRACT DOCUMENTS INTO SHOP DRAWINGS AND WORK. 9. CONSTRUCTION STAGING 9.A. INSTALL HOLLOW METAL DOOR FRAMES AS SHOWN AND SPECIFIED IN SECTION 08 11 13 AS THE WORK PROGRESSES. DO NOT HANG DOORS AND INSTALL FINISH HARDWARE UNTIL ALL WORK BY ALL CONTRACTORS HAS BEEN COMPLETED IN AN AREA AND THERE IS NO FURTHER CONSTRUCTION ACTIVITIES OR REQUIRED ENTRY BY A CONTRACTOR. DOORS AND FINISHED HARDWARE INSTALLED AND SUBSEQUENTLY DAMAGED IN ANY WAY FOR ANY REASON SHALL BE IMMEDIATELY REPLACED BY GENERAL CONTRACTOR AT NO ADDITIONAL COST TO THE CLIENT. IMMEDIATELY MEANS FROM THE TIME THE DAMAGE IS OBSERVED AND REPORTED TO THE GENERAL CONTRACTOR BY CONSTRUCTION MANAGEMENT TO THE TIME OF REINSTALLED SHALL NOT BE MORE THAN ONE MONTH. 9.B. DOOR FRAMES SHALL BE BOXED OUT IN WOOD TO PREVENT CONSTRUCTION DAMAGE. 9.C.INSTALL TEMPORARY 3/4" PLYWOOD DOORS AND LOCKS. REMOVE WHEN CONSTRUCTION ACCESS AND ACTIVITIES ARE FINISHED IN AN AREA AT THE TIME WHEN STAINLESS STEEL DOORS AND FINISH HARDWARE ARE INSTALLED. DEFERRED SUBMITTAL 1. GENERAL 1.A. THE FOLLOWING PORTIONS OF THE STRUCTURAL DESIGN WILL NOT BE SUBMITTED AT THE TIME OF PERMIT APPLICATION. WHEN RECEIVED AND REVIEWED, THESE DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE BUILDING OFFICIAL BY THE CONTRACTOR: -EXCAVATION SHORING STEEL NOTES 1. GENERAL 1.A. FABRICATION AND ERECTION OF STRUCTURAL STEEL SHALL CONFORM TO CURRENT. AISC MANUAL OF STEEL CONSTRUCTION. 2. BOLTED CONNECTIONS 2.A. ANCHORS AND STRUCTURAL BOLTS SHALL BE STRUCTURAL STEEL, ASTM A325, STRUCTURAL NUTS SHALL BE STRUCTURAL STEEL ASTM A563. ALL BOLTED STRUCTURAL CONNECTIONS SHALL CONFORM TO THE AISC SPECIFICATION FOR STRUCTURAL JOINTS. ALL STRUCTURAL BOLTED CONNECTIONS SHALL BE BEARING-TYPE CONNECTIONS. 3. ANCHOR BOLTS AND EMBEDDED THREADED RODS 3.A.ANCHOR BOLTS AND EMBEDDED THREADED RODS SHALL BE STRUCTURAL STEEL, ASTMF 1554, GRADE 55. 4. WELDING REQUIREMENTS: 4.A. WELDERS: HAVE IN POSSESSION CURRENT EVIDENCE OF PASSING THE APPROPRIATE AWS QUALIFICATION TESTS. 4.B. MINIMUM WELDS: AISC SPECIFICATION, NOT LESS THAN 3/16-INCH FILLET, CONTINUOUS UNLESS OTHERWISE NOTED. 4.C. WELD SIZES AND LENGTHS CALLED FOR ON THE DRAWINGS ARE THE NET EFFECTIVE REQUIRED. INCREASE WELD SIZE IF GAPS EXIST AT THE FAYING SURFACE. 4.D.WELD SIZES SHALL BE AS SHOWN UNLESS A GREATER SIZE IS REQUIRED BY ANSI/AISC 360-05 TABLES J2.3 AND J2.4. 4.E. ALL GROOVE WELDS SHALL BE COMPLETE PENETRATION UNLESS NOTED. 4.F. FIELD WELDING SYMBOLS INDICATE SUGGESTED CONSTRUCTION PROCEDURES. 4.G.WELDING ELECTRODES FOR PLAIN STRUCTURAL STEEL SHALL BE AWS SERIES E-70.WELDING ELECTRODES FOR GALVANIZED STEEL SHALL BE AWS SERIES E6010 OR E6011. 5.STRUCTURAL STEEL INSTALLATION: 5.A. ALL BOLTS USED IN CONNECTIONS SHALL BE INSTALLED SNUG TIGHT AS DEFINED BY AISC. UNLESS NOTED OTHERWISE. NO DATE ISSUE/REVISION APP MINIMUM STEEL REINFORCING COVER REQUIREMENTS CONCRETE SECTION CONCRETE POURED DIRECTLY AGAINST EARTH MINIMUM CLEAR COVER CONCRETE EXPOSED TO EARTH NO. 6 OR GREATER CONCRETE POURED EXPOSED TO EARTH NO. 5 OR SMALLER CONCRETE NOT EXPOSED TO EARTH 3 INCHES 2 INCHES 1 1/2 INCHES 1 1/2 INCHES UNLESS NOTED OTHERWISE LAP SPLICE AND DEVELOPMENT LENGTH SCHEDULE (INCHES) BA R S I Z E ( U S ) BA R DI A M E T E R F'c = 4500 PSI COMP TENSION LC E LC E LC S LD H LT E TO P LT E LT S TO P LT S #3 #4 #5 #6 #7 #8 #9 #10 #11 0.375 0.500 0.625 0.750 0.875 1.000 1.128 1.270 1.410 8 9 11 13 15 18 20 22 25 6 6 8 9 11 13 14 16 18 12 15 18 22 26 30 33 38 42 17 23 29 34 50 58 65 73 82 13 17 22 26 39 44 50 56 63 23 30 38 45 66 76 85 96 107 17 23 29 35 51 58 66 74 82 ConsultantsGEI GEI CONSULTANTS, INC. Enter office contact information in the type propterties Attention: If this scale bar does not measure 1" then drawing is not original scale. 0 1" SHEET NO.SHEET NAMEDesigned: Drawn: Checked: Approved: P.E. No: GEI Project 4/ 2 6 / 2 0 2 4 4 : 3 2 : 3 6 P M C : \ U s e r s \ P u b l i c \ D o c u m e n t s \ A u t o d es k \ 2 0 2 4 R e v i t P r o j e c t s \ M C A C P R O J 2 R E V _ b m a r t i n 5 2 Q Y 3 . rv t WRIGHT WATER ENGINEERS 818 COLORADO AVE. GLENWOOD SPRINGS, CO 81602 MCAC FISH PASSAGE DIVERSION GARFIELD COUNTY, COLORADO2303806 S-02 Enter PE No Approver K. DEBELEN Checker K. DEBELEN NOT FOR CONSTRUCTION BID SET STRUCTURAL NOTES (SHEET 2 OF 2) CONCRETE NOTES 1. GENERAL 1.A. ALL WORK SHALL CONFORM TO ACI 301, LATEST EDITION, UNLESS NOTED OTHERWISE IN DRAWINGS OR PROJECT SPECIFICATIONS. 1.B. DETAILING SHALL FOLLOW THE RECOMMENDATIONS OF ACI 315 UNLESS OTHERWISE NO CHANGES SHALL BE MADE WITHOUT PRIOR APPROVAL. 1.C. DETAIL BARS IN ACCORDANCE WITH THE LATEST EDITIONS OF PUBLICATION SP-66: “ACI DETAILING MANUAL”WITH ADDED REQUIREMENTS OF THE PROJECT SPECIFICATION AND ACI 318: “BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE.” 1.D. BEFORE PLACING CONCRETE, CHECK ALL APPLICABLE DRAWINGS RELEASED AS SUITABLE FOR CONSTRUCTION INCLUDING MANUFACTURER'S DRAWINGS TO VERIFY THE PRESENCE OF ALL EMBEDDED MATERIAL REQUIRED IN THE PLACEMENT. 2. DIMENSIONS 2.A. DIMENSIONS ARE TO THE CENTERLINES OF THE BARS UNLESS OTHERWISE SHOWN. CLEAR COVER DIMENSIONS ARE MARKED “CLR”. ALL DIMENSIONS TO A JOINT ARE TO THE CENTERLINE OF THE JOINT. BEAMS AND WALLS ARE CENTERED ON REFERENCED LINES UNLESS SHOWN OTHERWISE. 2.B. THICKNESSES SHOWN FOR WALLS AND SLABS ADJACENT TO UNDISTURBED SOIL OR ROCK ARE MINIMUM DIMENSIONS. 3. STRUCTURAL CONCRETE MIX REQUIREMENTS 3.A. SEE SPECIFICATIONS SECTION 03 30 00. 4. SLAB-ON-GRADE 4.A. TAKE PRECAUTIONS TO MINIMIZE SLAB CURLING. GRIND SLAB OR USE LEVELING COMPOUND IF FLOOR FLATNESS AND LEVELNESS VALUES ARE NOT ACCEPTABLE TO THE ENGINEER. 4.B.SEE SPECIFICATIONS SECTION 03 30 00 FOR FLOOR FLATNESS AND LEVELNESS REQUIREMENTS. 5. NON-SHRINK GROUT: 5.A. SEE SPECIFICATIONS SECTION 03 62 00. 6. REINFORCING MATERIALS 6.A. TYPICAL REINFORCING SHALL BE ASTM A615, GRADE 60. 6.B. FIELD BENT REINFORCING SHALL BE ASTM A706, GRADE 60. 7. REINFORCING FABRICATION 7.A. SPLICES: -NO SPLICING OF REINFORCEMENT PERMITTED EXCEPT AS NOTED ON DRAWINGS. MAKE BARS CONTINUOUS AROUND CORNERS. WHERE PERMITTED, SPLICES MAY BE MADE BY CONTACT LAPS OR MECHANICAL CONNECTORS. -SPLICES ARE TO BE MADE SO THAT GIVEN CLEAR DISTANCES TO THE FACE OF CONCRETE WILL BE MAINTAINED. -SEE 'LAP SPLICE SCHEDULE' FOR LAP LENGTHS. 7.B.HOOK EMBEDMENT NOTES -SIDE COVER IS 2 1/2 INCHES OR GREATER -COVER BEYOND IS 2 INCHES OR GREATER -IF SIDE COVER IS LESS THAN 2 1/2 INCHES, INCREASE LENGTHS BY 40% 8. PLACING REINFORCEMENT 8.A.PLACE REINFORCEMENT IN ACCORDANCE WITH APPROVED REINFORCEMENT SHOP DRAWINGS. IN THE EVENT OF A CONFLICT BETWEEN THESE DRAWINGS AND THE APPROVED SHOP DRAWINGS, THE APPROVED SHOP DRAWINGS SHALL GOVERN. 8.B.SEE ACI 318-19 26.6 AND ACI 301, SECTION 6.3 FOR REINFORCEMENT PLACING TOLERANCES AND ACI 117 FOR ADDITIONAL REQUIREMENTS. 8.C.THE FIRST AND LAST BARS IN SLABS AND WALLS, AND STIRRUPS IN BEAMS ARE TO START AND END AT A MAXIMUM OF ONE HALF THE ADJACENT BAR SPACING. ALL REINFORCING TO BE EQUALLY SPACED UNLESS OTHERWISE SHOWN ON THE DRAWINGS. 8.D.WHERE POSSIBLE, REINFORCEMENT SHALL BE PLACED TO MAINTAIN A CLEAR DISTANCE OF AT LEAST 1 INCH BETWEEN OTHER REINFORCEMENT, ANCHOR BOLTS, FORM TIES, OR OTHER EMBEDDED METALWORK. REINFORCEMENT PARALLEL TO ANCHOR BOLTS OR OTHER EMBEDDED METAL WORKS SHALL BE PLACED TO MAINTAIN A CLEAR DISTANCE OF AT LEAST 1-1/3 TIMES THE MAXIMUM SIZE AGGREGATE TO BE USED. 8.E.REINFORCEMENT PROTECTION: -SEE 'CONCRETE COVER TABLE' -SEE ACI 318-19 26.6 FOR REINFORCEMENT PLACING TOLERANCES AND ACI 117 FOR ADDITIONAL REQUIREMENTS 8.F.PROVIDE ACCESSORIES NECESSARY TO PROPERLY SUPPORT REINFORCING AT POSITIONS SHOWN ON PLANS. ALL REINFORCING, DOWELS, BOLTS, AND EMBEDDED PLATES SHALL BE SET AND TIED IN PLACE BEFORE THE CONCRETE IS POURED. “STABBING”INTO PREVIOUSLY PLACED CONCRETE IS NOT PERMITTED. 8.G.PROVIDE ADDITIONAL BARS OR STIRRUPS REQUIRED TO SECURE REINFORCING IN PLACE DURING CONCRETE PLACEMENT. 8.H.REINFORCEMENT MAY BE ADJUSTED IN THE FIELD TO CLEAR FORM TIES AND ANCHOR BARS. IN SUCH CASES, RELOCATION OF THE EMBEDDED MATERIALS MUST BE CONSIDERED. IN NO CASE SHOULD BARS BE BENT IN THE FIELD. 9. MISCELLANEOUS REINFORCING REQUIREMENTS: 9.A.MAKE ALL REINFORCING BAR BENDS IN THE FABRICATOR'S SHOP UNLESS NOTED. 9.B.NO WELDING OF REINFORCING PERMITTED UNLESS NOTED ON DRAWINGS. WHERE PERMITTED, PERFORM WELDING IN ACCORDANCE WITH AWS D1.4, LATEST EDITION. 9.C.PROVIDE ADDED REINFORCING TO TRIM ALL OPENINGS, NOTCHES, AND REENTRANT CORNERS AS NOTED IN TYPICAL DETAILS. 10. CONSTRUCTION/CONTROL JOINTS 10.A.SUBMIT DRAWINGS SHOWING CONSTRUCTION AND CONTROL JOINT LOCATIONS ALONG WITH THE SEQUENCE OF PLACEMENTS. CONSTRUCTION JOINT LOCATIONS AND CASTING SEQUENCE SHALL BE ARRANGED TO MINIMIZE THE EFFECTS OF ELASTIC AND LONG-TERM SHORTENING/SHRINKAGE. NO OTHER JOINTS SHALL BE INTRODUCED UNLESS APPROVED BY THE ENGINEER BEFORE CONCRETE IS PLACED. 10.B.CONTROL JOINTS SHALL CONFORM TO DETAILS PROVIDED ON DRAWINGS. IMMEDIATELY BEFORE THE SECOND CONCRETE PLACEMENT, THE PROJECTING HALF OF THE DOWEL SHALL BE GREASED TO PREVENT BOND TO THE CONCRETE. 10.C.CONSTRUCTION JOINTS IN SLABS-ON-GRADE, AND STRUCTURAL SLABS SHALL BE LOCATED TO ACCOMMODATE THE MAXIMUM LENGTH AND AREA THE CONTRACTOR CAN REASONABLY POUR, FINISH, AND JOINT IN THE SAME DAY, BUT SHALL NOT EXCEED A LENGTH OF 150 FEET WITH A MAXIMUM AREA OF 15,000 SQUARE FEET UNLESS APPROVED BY THE ENGINEER. 10.D.SHEAR FRICTION JOINTS: WHERE CONSTRUCTION JOINTS ARE LABELED AS “ROUGHENED”ON THE DRAWINGS, THE ENTIRE JOINT SURFACE SHALL BE MECHANICALLY ROUGHENED TO A 1/4”AMPLITUDE AND THOROUGHLY CLEANED. EXPOSE THE COURSE AGGREGATE IN THE HARDENED CONCRETE AND REMOVE ALL LOOSE MATERIAL 11. FINISHING 11.A.SEE SPECIFICATIONS SECTION 03 30 00. 11.B.UNLESS OTHERWISE INDICATED, CHAMFER EDGES OF ALL PERMANENTLY EXPOSED CONCRETE SURFACES WITH A 45 DEGREE BEVEL, 3/4 INCH X 3/4 INCH. CHAMFER STRIP MAY NOT BE SHOWN ON THE DESIGN DRAWINGS. 12. MEP AND OTHER OPENINGS AND EMBEDMENTS: 12.A.PROVIDE SLEEVES AT OPENINGS (SUCH AS THOSE REQUIRED FOR PLUMBING AND ELECTRICAL PENETRATIONS) BEFORE PLACING CONCRETE. DO NOT CUT REINFORCING WHICH MAY CONFLICT. CORING OF CONCRETE IS NOT PERMITTED. 12.B.REFER TO TYPICAL DETAILS FOR SPACING LIMITS ON SLEEVES AND FOR REQUIREMENTS FOR EMBEDDED CONDUIT AND PIPE. NO DATE ISSUE/REVISION APP S-03 A 38'-10 1/2" 10 ' - 3 1 / 2 " TRASHRACK, TYPE 1 WALL OPENING, TYP 5'-2 1/2 " 1 0'-0 " 5'-3 1/2 " 2 " 1 5'-0 " 3'-0 " S-05 5 S-07 13 8'-2 1/2" 13'-4 1/2" 3 8'-8 1/2" 12'-3 1/2" 3'-0" 20'-0" 1'-0" 2'-7" CJ E L 5 9 0 9'-0" E L 5 9 1 0'-8 1/2" EL 5908'-0"EL 5911'-0" MCNICHOL'S 19-W -4 GALVANIZED GW -150 GRATING (SERRATED) W10X15 (A992) 8' - 9 " 5'-9" 3 S-05 NOTES: 1. TRASHRACK AND FRAMING NOT SHOWN FOR CLARITY. EL 5908'-0"EL 5908'-0" EL 5911'-0" EL 5896'-0" EL 5905'-8 1/2" EL 5906'-1 1/2" 4' - 0 " TRASHRACK OPENING TRASHRACK, TYPE 1 DIVERSION WALL, TYP CJ CJ FISH SCREEN, TYPE 1 GRATING, TYP S-03 A 7'-3" 44'-2" 3 4'-1 0" 4 1'-4 " 18 ' - 9 " 8' - 9 " 13'-5"EL 5896'-0" EL 5905'-8 1/2" EL 5906'-1 1/2" S-08 15 S-08 16WALL CENTERLINE ConsultantsGEI GEI CONSULTANTS, INC. Enter office contact information in the type propterties Attention: If this scale bar does not measure 1" then drawing is not original scale. 0 1" SHEET NO.SHEET NAMEDesigned: Drawn: Checked: Approved: P.E. No: GEI Project 4/ 2 6 / 2 0 2 4 4 : 3 2 : 3 9 P M C : \ U s e r s \ P u b l i c \ D o c u m e n t s \ A u t o d es k \ 2 0 2 4 R e v i t P r o j e c t s \ M C A C P R O J 2 R E V _ b m a r t i n 5 2 Q Y 3 . rv t WRIGHT WATER ENGINEERS 818 COLORADO AVE. GLENWOOD SPRINGS, CO 81602 MCAC FISH PASSAGE DIVERSION GARFIELD COUNTY, COLORADO2303806 S-03 Enter PE No Approver K. DEBELEN Checker K. DEBELEN NOT FOR CONSTRUCTION BID SET PROJECT 2 DIVERSION WALL PLAN SCALE:1/8" = 1'-0" DIVERSION WALL PROJECT 2 PLAN VIEW SECTION S-03 SCALE: 1/8" = 1'-0" A WALL SECTION - PROJECT 2 PROJECT 2 WALL ISOMETRIC NOTES: 1. ALIGNMENT CHANGES ARE TO BE COORDINATED THROUGH CENTER OF WALL. NO DATE ISSUE/REVISION APP PLAN SCALE: 1/8" = 1'-0" DIVERSION WALL PROJECT 2 FOUNDATION PLAN VIEW GRATING NOT SHOWN FOR CLARITY S-04 2 S-04 1 2'-0" 1'-0" 4'-8" 1'-0" 2'-0" 10'-8" 2' - 0 " 1 ' - 0 " 4 ' - 8 " 1 ' - 0 " 2 ' - 0 " 10 ' - 8 " S-04 2 4'-1" 2'-6" 2'-1" 2'-0" 10'-8" 1' - 0 " 6 " 3 ' - 1 0 " 5' - 4 " EL 5897'-9 1/2" EL 5898'-3 1/2" EL 5902'-1" S-04 1 1' - 0 " 6 " 2 ' - 6 " 1 ' - 4 " 5' - 4 " 2'-0" 1'-0" 4'-8" 1'-0" 2'-0" 10'-8" EL 5902'-1" EL 5898'-3 1/2" EL 5897'-9 1/2" ConsultantsGEI GEI CONSULTANTS, INC. Enter office contact information in the type propterties Attention: If this scale bar does not measure 1" then drawing is not original scale. 0 1" SHEET NO.SHEET NAMEDesigned: Drawn: Checked: Approved: P.E. No: GEI Project 4/ 2 6 / 2 0 2 4 4 : 3 2 : 3 9 P M C : \ U s e r s \ P u b l i c \ D o c u m e n t s \ A u t o d es k \ 2 0 2 4 R e v i t P r o j e c t s \ M C A C P R O J 2 R E V _ b m a r t i n 5 2 Q Y 3 . rv t WRIGHT WATER ENGINEERS 818 COLORADO AVE. GLENWOOD SPRINGS, CO 81602 MCAC FISH PASSAGE DIVERSION GARFIELD COUNTY, COLORADO2303806 S-04 Enter PE No Approver K. DEBELEN Checker K. DEBELEN NOT FOR CONSTRUCTION BID SET PROJECT 2 SPLITTER STRUCTURE NO DATE ISSUE/REVISION APP PROJECT 2 SPLITTER ISOMETRICPLAN SCALE:3/8" = 1'-0" SPLITTER STRUCTURE PROJECT 2 - PLAN VIEW DETAIL S-04 SCALE: 3/8" = 1'-0" 1 SPLITTER STRUCTURE PROJECT 2 - SECTION A DETAIL S-04 SCALE: 3/8" = 1'-0" 2 SPLITTER STRUCTURE PROJECT 2 - SECTION B NOTES: PROPOSED SINGLE CHAMBER SPLITTER STRUCTUER SHOWN. FINAL CONFIGURATION TO BE UPDATED TO MATCH STRUCTRE DEVELOPED IN WWE DRAWINGS. NOTE: SPLITTER STRUCTURE STRUCTURAL DETAIL TO BE UPDATED BASED ON OUTCOME OF BIDS. SPLITTER STRUCTURE SHOWN ON THIS PAGE TO BE INCLUDED IN EITHER BASE BID WITH INCLUSION OF ADDITIONAL CELL OR BID ALTERNATE WITH CONCRETE MANHOLE. BID THE QUANTITIES IN THE BID SCHEDULE. HE I G H T V A R I E S #8 @ 12" OC, EF ABOVE FIRST 6' OF WALL 4'-6" 1'-6" 4'-0" 2' - 0 " LT S #8 @ 9" OC, EF FIRST 6' OF WALL #8 @ 12" OC, EF 10'-0" 3" M I N 3" MIN 3" MIN #8 @ 12" OC, EW, EF CJ TYP 2 1/2" 1 1/2" 1 1 / 2 " 1 1 / 2 " 1 1 / 2 " 3" 3"3" 3" 1 1 / 2 " 1 1 / 2 " 1 1 / 2 " NOTE: STANDARD HORIZONTAL SHORT SLOT CONNECTION AT ONE END OF BEAM. 1" MIN L6x4x3/8 6" LONG A36 (2) PER CONNECTION W10x15 A992 1/2" DIA HILTI KBTZ2 4" MIN EMBEDMENT 5" MIN EDGE DISTANCE ASSUME MIN 30000psi NWC 1-3/4"x1-3/4"x1/4" STEEL ANGLE 1/2" DIA THRU BOLTS A325 1/2" DIA HEADED STUD x 6 LONG @ 12" O.C. S-05 4 ConsultantsGEI GEI CONSULTANTS, INC. Enter office contact information in the type propterties Attention: If this scale bar does not measure 1" then drawing is not original scale. 0 1" SHEET NO.SHEET NAMEDesigned: Drawn: Checked: Approved: P.E. No: GEI Project 4/ 2 6 / 2 0 2 4 4 : 3 2 : 4 0 P M C : \ U s e r s \ P u b l i c \ D o c u m e n t s \ A u t o d es k \ 2 0 2 4 R e v i t P r o j e c t s \ M C A C P R O J 2 R E V _ b m a r t i n 5 2 Q Y 3 . rv t WRIGHT WATER ENGINEERS 818 COLORADO AVE. GLENWOOD SPRINGS, CO 81602 MCAC FISH PASSAGE DIVERSION GARFIELD COUNTY, COLORADO2303806 S-05 Enter PE No Approver K. DEBELEN Checker K. DEBELEN NOT FOR CONSTRUCTION BID SET CONCRETE DETAILS (SHEET 1 OF 2) SECTION S-03 SCALE: 3/4" = 1'-0" 5 DIVERSION WALL REINFORCEMENT DETAIL NO DATE ISSUE/REVISION APP DETAIL S-05 SCALE: 3" = 1'-0" 4 GRATING BEAM CONNECTION SECTION DETAIL S-03 SCALE: 1 1/2" = 1'-0" 3 GRATING BEAM CONNECTION 1 1 / 2 " 1 1 / 2 " (2) 1/2" DIA FH SS BOLT CONDITION CW Fy>65ksi 2"2" 4x4x1/4" ALUM ANGL 6061-T6 6" 1 1 / 2 " 1 1/2"1 1/2" (2) 1/2" DIA SS BOLT CONDITION CW Fy>=65ksi SPACE 4" O.C. (2) 3/8" DIA HILTI KH-EZ C 2-1/2" MIN EMBEDMENT 3" MIN EDGE DISTANCE ASSUME 3000psi NW CONCRETE 4x4x1/4" ALUM ANGLE 6061-T6 1" 2 3/4" 1 1 / 2 " 1 1/2"1 1/2" (2) 3/8" DIA HILTI KH-EZ C 2-1/2" MIN EMBEDMENT 3" MIN EDGE DISTANCE ASSUME 3000psi NW CONCRETE 2 3/4" (2) 3/8" DIA FH SS BOLT CONDITION CW Fy>65ksi 2x2x1/4" ALUM ANGL 6061-T6 4" 2" (2) 1/4" DIA HILTI KH-EZ C 2-1/2" MIN EMBEDMENT 3" MIN EDGE DISTANCE ASSUME 3000psi NW CONCRETE 1" 1" 1" 1" 1" 1" 1" 1" 1" (2) 1/4" DIA HILTI KH-EZ C 2-1/2" MIN EMBEDMENT 3" MIN EDGE DISTANCE ASSUME 3000psi NW CONCRETE 2x2x1/4" ALUM ANGLE 6061-T6 1/2" DIA SS BOLT CONDITION CW Fy>=65ksi ConsultantsGEI GEI CONSULTANTS, INC. Enter office contact information in the type propterties Attention: If this scale bar does not measure 1" then drawing is not original scale. 0 1" SHEET NO.SHEET NAMEDesigned: Drawn: Checked: Approved: P.E. No: GEI Project 4/ 2 6 / 2 0 2 4 4 : 3 2 : 4 0 P M C : \ U s e r s \ P u b l i c \ D o c u m e n t s \ A u t o d es k \ 2 0 2 4 R e v i t P r o j e c t s \ M C A C P R O J 2 R E V _ b m a r t i n 5 2 Q Y 3 . rv t WRIGHT WATER ENGINEERS 818 COLORADO AVE. GLENWOOD SPRINGS, CO 81602 MCAC FISH PASSAGE DIVERSION GARFIELD COUNTY, COLORADO2303806 S-06 Enter PE No Approver K. DEBELEN Checker Designer NOT FOR CONSTRUCTION BID SET CONCRETE DETAILS (SHEET 2 OF 2) NO DATE ISSUE/REVISION APP DETAIL S-07 SCALE: 6" = 1'-0" 6 TRASHRACK CORNER CONNECTION DETAIL S-07 SCALE: 6" = 1'-0" 8 BOTTOM TRASHRACK CONNECTION DETAIL S-07 SCALE: 6" = 1'-0" 7 TOP TRASHRACK CONNECTION DETAIL S-08 SCALE: 6" = 1'-0" 9 FISH SCREEN CORNER CONNECTION DETAIL S-08 SCALE: 6" = 1'-0" 10 TOP FISH SCREEN CONNECTION DETAIL S-08 SCALE: 6" = 1'-0" 11 BOTTOM FISH SCREEN CONNECTION RT4x6x1/4" 6061-T6 4x4x1/4" ALUM ANGLE x 6" LONG COPED W10x7.3 6061-T6 AC9x4.98 6061-T6 1-1/2" ALUM BAR 5086-H34 4X4X1/4" Alum Angle 6061-T6 4" 4 ' - 4 3 / 4 " MA X C O P E D I M E N S I O N = 9 " S-07 14 3/ 4 " 4 ' - 8 " 4" 3" 5'-0" 5'-0" 3" 4" 11'-2" 8 S-06 7 S-06 6 S-06 6" MAX, OC 3/16"1-1/2" 3/16" 1-1/2" 5356 TYP AT ALL BAR-TUBE CONNECTIONS 2' - 4 " RT4x6x1/4" 6061-T6 1 1/2" ALUM BAR 5086-H34 ConsultantsGEI GEI CONSULTANTS, INC. Enter office contact information in the type propterties Attention: If this scale bar does not measure 1" then drawing is not original scale. 0 1" SHEET NO.SHEET NAMEDesigned: Drawn: Checked: Approved: P.E. No: GEI Project 4/ 2 6 / 2 0 2 4 4 : 3 2 : 4 2 P M C : \ U s e r s \ P u b l i c \ D o c u m e n t s \ A u t o d es k \ 2 0 2 4 R e v i t P r o j e c t s \ M C A C P R O J 2 R E V _ b m a r t i n 5 2 Q Y 3 . rv t WRIGHT WATER ENGINEERS 818 COLORADO AVE. GLENWOOD SPRINGS, CO 81602 MCAC FISH PASSAGE DIVERSION GARFIELD COUNTY, COLORADO2303806 S-07 Enter PE No Approver K. DEBELEN Checker Designer NOT FOR CONSTRUCTION BID SET TYPE 1 TRASHRACK DETAILS TRASHRACK TYPE 1 ISO DETAIL S-07 SCALE: 1" = 1'-0" 14 TRASHRACK SECTION TYPE 1 DETAIL S-03 SCALE: 1" = 1'-0" 13 TRASHRACK ELEVATION TYPE 1 DETAIL SCALE: 1" = 1'-0" 12 TRASHRACK PANEL ELEVATION TYPE 1 (TYP 4 LOCATIONS) NO DATE ISSUE/REVISION APP CS 2x1.07 2x2x3/8" 6061 T-6 ALUM ANGLE MCNICHOLS PERFORATED METAL FISH SCREEN COPED W F 4x4.76 2x2x1/4" ALUM ANGLE 6061-T6 4'-11" 4' - 0 " 4" 3 ' - 4 " 4 " 2" 5'-2"5'-2" 2" 10'-7" 1" MIN 1" 6" 11 S-06 10 S-06 9 S-06 ConsultantsGEI GEI CONSULTANTS, INC. Enter office contact information in the type propterties Attention: If this scale bar does not measure 1" then drawing is not original scale. 0 1" SHEET NO.SHEET NAMEDesigned: Drawn: Checked: Approved: P.E. No: GEI Project 4/ 2 6 / 2 0 2 4 4 : 3 2 : 4 3 P M C : \ U s e r s \ P u b l i c \ D o c u m e n t s \ A u t o d es k \ 2 0 2 4 R e v i t P r o j e c t s \ M C A C P R O J 2 R E V _ b m a r t i n 5 2 Q Y 3 . rv t WRIGHT WATER ENGINEERS 818 COLORADO AVE. GLENWOOD SPRINGS, CO 81602 MCAC FISH PASSAGE DIVERSION GARFIELD COUNTY, COLORADO2303806 S-08 Enter PE No Approver K. DEBELEN Checker Designer NOT FOR CONSTRUCTION BID SET TYPE 1 FISH SCREEN DETAILS NO DATE ISSUE/REVISION APP FISH SCREEN TYPE 1 ISO DETAIL S-03 SCALE: 1" = 1'-0" 15 FISH SCREEN TYPE 1 PANEL ELEVATION DETAIL S-03 SCALE: 1" = 1'-0" 16 FISH SCREEN TYPE 1 STRUCTURE ELEVATION