Loading...
HomeMy WebLinkAbout1.11 Middle Colorado Ag Collaborative - Roseman (Project 4)_Part2DocuSign Envelope ID: 46674887-F14F-4F6F-9C1F-E4E6C5C66633 x x x xx ^ ^ ^ ^ ^ ^ ^ ^ ^ ^^^ ^ ^ ^^ ^ ^ ^ ^ ^ ^ ^ ^^^ w w w w w w w w w w w w w w w w www w w w w w w w w 5689 5687 5689 5691 5693 5695 5 6 9 6 5 6 9 3 5690 5691 5692 5693 5694 5695 569 9 570 0 570 1 56 9 5 57 0 2 57 0 3 57 0 4 57 0 5 57 0 6 5707 5692 5691 5693 5694 56 9 5 56 9 5 5694 5689 5690 5690 5689 5695 5696 5 6 9 5 5696 5697 569 8 569 0 5691 5692 5691 5692 5690 56 9 1 569 0 569 1 569 2 569 3 5 6 9 3 56 9 4 56 9 3 56 9 2 56 9 1 5 6 9 2 5 6 9 3 5 6 9 4 56 9 3 5 6 9 4 56 9 6 5 6 9 0 5 6 9 0 56 9 5 56 9 6 56 9 7 56 9 8 569 4 5695 5696 56 9 5 56 9 4 56 9 6 569 8 1+00 2+ 0 0 2+3 0 2+91 1+00 2+00 2+10 1+00 2+ 0 0 1+ 0 0 1+ 8 5 C1 C2 C3 C4 C5 C6 C7 C8 L1 L2 L3 L4 L 5 L6 L 7 L8 L9 L 1 0 L12 L1 1 L14 L15 L16 L1 7 L18 L1 9 L20 L2 1 L2 2 L2 3 L24 L2 5 L2 6 BEGIN ROSEMAN - FISH PASSAGE ALIGNMENT STA: 1+00.00 N: 1648912.99 E: 2416511.06 END ROSEMAN - FISH PASSAGE ALIGNMENT STA: 2+91.30 N: 1649019.29 E: 2416415.10 BEGIN ROSEMAN - DIVERSION ALIGNMENT STA: 1+00.00 N: 1648888.86 E: 2416452.92 END ROSEMAN - DIVERSION ALIGNMENT STA: 2+30.42 N: 1649017.33 E: 2416450.91 BEGIN ROSEMAN - SEDIMENT SLUICE ALIGNMENT STA: 1+00.00 N: 1648967.10 E: 2416497.77 END ROSEMAN - SEDIMENT SLUICE ALIGNMENT STA: 2+10.39 N: 1649019.29 E: 2416415.10 BEGIN ROSEMAN - OVERFLOW CHANNEL ALIGNMENT STA: 1+00.00 N: 1648936.78 E: 2416428.56 END ROSEMAN - OVERFLOW CHANNEL ALIGNMENT STA: 1+85.00 N: 1648943.61 E: 2416513.28 1+0 0 2 + 0 0 2 + 1 6 2+02 1+00 2+ 0 0 L27 L2 8 L29 L 3 0 L31 L3 2 L3 3 L34 L 3 5 L3 6 BEGIN ROSEMAN - DIVERSION CREST AND CONCRETE WALL SECTION ALIGNMENT STA: 1+08.82 N: 1648999.24 E: 2416407.98 END ROSEMAN - DIVERSION CREST AND CONCRETE WALL SECTION ALIGNMENT STA: 2+15.59 N: 1649057.37 E: 2416492.02 BEGIN ROSEMAN - DIVERSION AND SEDIMENT SLUICE WALL ALIGNMENT STA: 1+00.00 N: 1648963.44 E: 2416486.14 BEGIN ROSEMAN - DIVERSION AND SEDIMENT SLUICE WALL ALIGNMENT STA: 2+02.48 N: 1648999.83 E: 2416410.00 FISH PASSAGE ALIGNMENT DIVERSION ALIGNMENT SEDIMENT SLUICE ALIGNMENT OVERFLOW CHANNEL LINE DATA LINE # L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12 LENGTH 13.66' 9.20' 16.82' 3.29' 3.15' 2.75' 4.31' 0.12' 2.38' 5.20' 4.48' 1.00' DIRECTION N19°03'30"W N7°40'52"W N3°20'44"E N49°20'41"W N34°57'39"E N56°22'49"W N30°21'37"E N80°11'22"W N52°56'18"W S46°01'48"W N79°33'36"W N79°33'36"W START STATION 1+00.00 1+13.66 1+22.86 1+49.42 1+63.14 1+76.37 1+89.71 2+07.29 2+13.25 2+28.44 2+43.02 2+47.50 END STATION 1+13.66 1+22.86 1+39.68 1+52.71 1+66.29 1+79.11 1+94.02 2+07.41 2+15.63 2+33.64 2+47.50 2+48.50 CURVE DATA CURVE # C1 C2 C3 C4 C5 C6 C7 C8 RADIUS 10.59' 7.09' 6.32' 7.00' 6.88' 12.28' 9.06' 9.88' LENGTH 9.74' 10.43' 10.08' 10.60' 13.27' 5.84' 12.81' 9.38' CHORD DIRECTION N22°59'59"W N7°11'31"W N10°42'35"W N13°00'36"W N24°54'52"W N66°33'50"W S86°32'45"W S73°14'06"W START STATION 1+39.68 1+52.71 1+66.29 1+79.11 1+94.02 2+07.41 2+15.63 2+33.64 END STATION 1+49.42 1+63.14 1+76.37 1+89.71 2+07.29 2+13.25 2+28.44 2+43.02 LINE DATA LINE # L14 L15 L16 L17 L18 LENGTH 28.24' 36.20' 30.56' 10.42' 25.00' DIRECTION N13°48'09"W N8°09'25"W N7°14'58"E N11°21'08"E N9°06'19"E START STATION 1+00.00 1+28.24 1+64.44 1+94.99 2+05.42 END STATION 1+28.24 1+64.44 1+94.99 2+05.42 2+30.42 LINE DATA LINE # L19 L20 L21 L22 L23 L24 L25 LENGTH 12.46' 30.13' 10.38' 9.11' 12.48' 6.12' 29.70' DIRECTION N78°08'30"W N23°55'17"W N77°38'11"W N79°29'30"W N78°57'56"W N10°37'45"E N70°43'41"W START STATION 1+00.00 1+12.46 1+42.59 1+52.97 1+62.08 1+74.57 1+80.69 END STATION 1+12.46 1+42.59 1+52.97 1+62.08 1+74.57 1+80.69 2+10.39 LINE DATA LINE # L26 LENGTH 85.00' DIRECTION N85°23'19"E START STATION 1+00.00 END STATION 1+85.00 LINE DATA LINE # L27 L28 L29 L30 LENGTH 20.00' 25.71' 28.79' 41.09' DIRECTION N9°20'45"E S80°50'19"E N10°26'24"E N50°26'24"E START STATION 1+00.00 1+20.00 1+45.71 1+74.50 END STATION 1+20.00 1+45.71 1+74.50 2+15.59 LINE DATA LINE # L31 L32 L33 L34 L35 L36 LENGTH 35.00' 10.00' 8.00' 1.84' 6.05' 41.59' DIRECTION N23°55'17"W N80°06'52"W N79°59'31"W S8°43'09"W S31°42'07"W N78°33'24"W START STATION 1+00.00 1+35.00 1+45.00 1+52.99 1+54.83 1+60.88 END STATION 1+35.00 1+45.00 1+52.99 1+54.83 1+60.88 2+02.48 DIVERSION CREST AND CONCRETE WALL DIVERSION AND SEDIMENT SLUICE WALL ALIGNMENT ALIGNMENT JBH/DTL JBH/DTL SDS 4/26/2024 SHOWN MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 3-BUSINESS DAYS IN ADVANCE CENTER OF COLORADO OR CALL UTILITY NOTIFICATION 1-800-922-1987 811 CALL COLORADO NO.BY DATE COMMENTS SCALE DETAIL CHECK DESIGN Pl o t D a t e / T i m e : 0 4 / 2 5 / 2 0 2 4 , 0 8 : 2 3 : 0 3 P M ; G : \ W W E \ 2 1 1 - 0 2 0 \ 0 2 0 \ C A D \ 0 2 _ D W G S \ H Z X X - P R O J E C T 4 H O R I Z O N T A L C O N T R O L . D W G - H Z 0 1 H O R I Z O N T A L C O N T R O L P L A N SHEET NO. JOB NO. REVISION NO. DATE DESCRIPTIONWRIGHT WATER ENGINEERS, INC. GLENWOOD SPRINGS, CO 81602 (970)945-7755 FAX(970)945-9210 818 COLORADO AVE. P.O. BOX 219 DRAFT NOT FOR CONSTRUCTION BID SET 4/26/2024 4/26/2024 10 10 20 FT0 NORTH PLAN HORIZONTAL CONTROL PLAN 211-020.020 ---- HZ01 ROSEMAN DIVERSION ALIGNMENT TABLE ALIGNMENT NAME SHEET NUMBER FISH PASSAGE PP01 DIVERSION PP02 SEDIMENT SLUICE PP03 OVERFLOW CHANNEL PP04 DIVERSION CREST AND CONCRETE WALL XS01 DIVERSION STRUCTURE CREST XS01 DIVERSION AND SEDIMENT SLUICE WALL XS02 x x ^ ^ ^ ^ ^ ^ ^ ^ ^ ^^ ^ ^ ^ ^^ ^ ^ ^ ^ ^ ^ ^ ^^ ^ ^ w w w w w w w w w w w w w w w w w ww w w w w 5690 5691 5692 5689 5688 5687 568 9 569 1 569 3 5695 5 6 9 6 5 6 9 5 5 6 9 3 5690 5691 5692 5693 5694 5695 5691 5692 569 9 5700 5701 56 9 5 57 0 2 57 0 3 57 0 4 57 0 5 57 0 6 STREAM SUBSTRATE (D50 = 18"), 3' THICK BOULDERS REVEGETATION: WILLOW STAKES DIVERSION DAM STRUCTURE CONCRETE WALL ELK C R E E K FLOW FLOW ROSEMAN - FISH PASSAGE, SEE PROFILE BELOW 5' WIDE LOW FLOW NOTCH, REMOVE EXISTING WINGWALL IN FRONT OF PROPOSED LOW FLOW CHANNEL EXISTING CONCRETE SEDIMENT SLUICE STRUCTURE TO REMAIN. INSTALL FABRICATED HEADGATE, TELEMETRY, AND ACTUATOR PROPOSED CONCRETE STRUCTURE WITH REMOVABLE TRASH RACK AND FISH SCREEN ROCK VANE ELK CREEK OVERFLOW CHANNEL, SEE SHEET PP04 5692 5691 5693 5694 56 9 5 56 9 5 5694 5689 5690 5690 5689 5695 5696 5 6 9 5 569 6 569 7 56 9 8 569 0 569 1 569 2 5691 5692 5690 56 9 1 5 6 8 9 569 0 569 1 5692 569 3 5 6 9 3 56 9 4 56 9 3 569 2 56 9 1 56 9 2 56 9 3 5 6 9 4 56 9 3 56 9 6 5693 5 6 9 0 5 6 9 0 56 9 5 56 9 6 56 9 7 56 9 8 56 9 4 5695 5696 56 9 5 56 9 4 56 9 6 56 9 8 56 9 4 56 9 5 569 5 569 3 5694 5696 569 7 5699 569 8 POOLS TO BE DEVELOPED BETWEEN BOULDER SILLS FEATURE BOULDER 2+9 1 1+00 2+00 56 9 5 56 9 7 56 9 8 5692 5693 EL E V A T I O N , ( F T ) STA. (FT) ROSEMAN - FISH PASSAGE PROFILE 5675 5680 5685 5690 5695 5700 5705 5675 5680 5685 5690 5695 5700 5705 1+00 2+00 3+00 EXISTING GRADE SCOUR POOL AVERAGE FISH PASSAGE SLOPE = 4.1%, SEE SHEETS DT04 AND DT05 2.0'2.0'2.0'2.0'2.0' 2.0' 2.0' PROJECTED CONCRETE STRUCTURE, SEE PLAN VIEW MATCH EXISTING GRADE STA: 1+37.06 EL: 5690.16 LOW FLOW CHANNEL CREST INVERT STA: 2+47.50 EL: 5694.65 DIVERSION DAM CREST ELEVATION STA: 2+47.50 EL: 5695.15 MATCH EXISTING GRADE STA: 2+86.47 EL: 5693.48 BOULDER SILL CREST STA: 1+51.07 EL: 5690.39 BOULDER SILL CREST STA: 1+64.71 EL: 5690.66 BOULDER SILL CREST STA: 1+77.90 EL: 5691.29 BOULDER SILL CREST STA: 1+91.83 EL: 5691.97 BOULDER SILL CREST STA: 2+10.24 EL: 5692.85 BOULDER SILL CREST STA: 2+31.27 EL: 5693.87 PROPOSED GRADE STREAM SUBSTRATE (D50 = 18"), 3' THICK STREAM SUBSTRATE MIXED WITH ON-SITE MATERIAL WHERE ADDITIONAL FILL IS REQUIRED BEYOND BOULDERS AND STREAM SUBSTRATE PLACE BOULDERS IN FRONT OF LOW FLOW CHANNEL, SEE NOTE 1 DIVERSION DAM STRUCTUREPOOL, SEE PHOTO 1 JBH/DTL JBH/DTL SDS 4/26/2024 SHOWN MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 3-BUSINESS DAYS IN ADVANCE CENTER OF COLORADO OR CALL UTILITY NOTIFICATION 1-800-922-1987 811 CALL COLORADO NO.BY DATE COMMENTS SCALE DETAIL CHECK DESIGN Pl o t D a t e / T i m e : 0 4 / 2 5 / 2 0 2 4 , 0 8 : 2 5 : 2 5 P M ; G : \ W W E \ 2 1 1 - 0 2 0 \ 0 2 0 \ C A D \ 0 2 _ D W G S \ P P X X - D I V E R S I O N A N D F I S H P A S S A G E P & P . D W G - P P 0 4 - 1 - R O S E M A N F I S H P A S S A G E P & P SHEET NO. JOB NO. REVISION NO. DATE DESCRIPTIONWRIGHT WATER ENGINEERS, INC. GLENWOOD SPRINGS, CO 81602 (970)945-7755 FAX(970)945-9210 818 COLORADO AVE. P.O. BOX 219 DRAFT NOT FOR CONSTRUCTION BID SET 4/26/2024 4/26/2024 10 10 20 FT0 0 1010 0 55 VERTICALHORIZONTAL 20 FT 10 FT NORTH PLAN PROFILE FISH PASSAGE PLAN & PROFILE 211-020.020 ---- PP01 ROSEMAN DIVERSION NOTES: 1.BOULDERS ALONG DIVERSION DAM TO BE INSTALLED IN COORDINATION WITH ENGINEER. 2.THE INTENT OF THE PROPOSED ROCK FILL DOWNSTREAM OF THE RAMP IS TO CREATE A SERIES OF POOLS TO PROMOTE FISH PASSAGE AND PROVIDE AREAS OF REFUGIA. 3.PLACEMENT OF ALL BOULDERS SHOULD BE REVIEWED AND ACCEPTED BY THE ENGINEER. BOULDERS PLACED WITHOUT ENGINEER APPROVAL ARE SUBJECT TO REMOVAL AND REPLACEMENT. PHOTO 1 EXAMPLE CONSTRUCTED STEP POOL SYSTEM x x x xx ^ ^ ^^ ^ ^ ^ ^^ ^ ^ ^ ^ ^^ ^ ^ ^ ^ w w w w w w w w w w w w w w w 56985697 5696 5695 5694 5693 5694 5696 5698 5695 5697 5699 569 5 56 9 4 5 6 9 6 5 7 0 0 5 6 9 9 57 0 1 57 0 2 57 0 3 5 7 0 4 5 7 0 5 5 7 0 6 5 7 0 7 5 7 0 8 57 0 0 57 0 5 571 0 571 5 56 9 9 56 9 8 56 9 7 56 9 6 56 9 5 56 9 4 5 6 9 9 PROTECT EXISTING 48-INCH CONCRETE FLUME IN PLACE AND ADD FLOW MEASUREMENT TELEMETRY REVEGETATION AREA (TYP.) PROPOSED CONCRETE STRUCTURE WITH CONCRETE FLOOR AND REMOVABLE TRASH RACK AND FISH SCREEN DIVERSION DAM SHEET PILE WITH CONCRETE CAP CONCRETE WALL ROSEMAN - DIVERSION ROCK VANE ELK C R E E K FLO W 3' X 3' CONCRETE PAD FOR DAVIT CRANE INSTALL RAILING ON CONCRETE WALL, SEE SHEET XS01 PROPOSED GRATE BOULDERS 5694 5695 5696 569 6 569 5 569 4 5693 5694 5695 5696 5693 5694 5695 OVERFLOW CHANNEL, SEE SHEET PP04 5694 5 6 9 5 56 9 5 5694 5693 5692 5695 5696 5697 5698 5692 56 9 3 5691 56 9 5 5 6 9 6 56 9 4 56 9 3 56 9 2 56 9 1 5 6 9 2 5 6 9 3 5694 5 6 9 5 VOID-FILLED RIPRAP, (D50 = 18"), 3' THICK VOID-FILLED RIPRAP, (D50 = 18"), 3' THICK 4H:1V CONCRETE ENTRANCE RAMP AT FLUME 56 9 3 5 6 9 4 569 4 56 9 5 5696 56 9 7 569 9 57 0 0 1+00 2+00 2+30 5693 56935692 STA. (FT) ROSEMAN - DIVERSION PROFILE 5680 5685 5690 5695 5700 5705 5710 5680 5685 5690 5695 5700 5705 5710 1+00 2+00 2+60 EXISTING GRADE 1.0%4.0 : 1 REGRADE DITCH DOWNSTREAM OF DIVERSION TO PROPOSED FLUME EXISTING CONCRETE DIVERSION STRUCTURE TO REMAIN 5' WIDE, 6" DEEP LOW FLOW CHANNEL INV EL: 5694.65 (SUPERIMPOSED) RAISE EXISTING CONCRETE WALL 4.0', SEE SHEET XS02 PROPOSED DIVERSION AT EXISTING INVERT ELEVATION INV EL: 5692.91 PROPOSED SEDIMENT SLUICE AT EXISTING INVERT ELEVATION INV EL: 5691.51 PROPOSED DIVERSION BOX FLOOR EL: 5691.18 STA: 1+23.75 EL: 5692.77 STA: 1+27.75 EL: 5691.77 STA: 1+93.04 EL: 5692.87 STA: 1+91.15 EL: 5692.40 PROTECT EXISTING 48-INCH CONCRETE FLUME IN PLACE AND ADD FLOW MEASUREMENT TELEMETRY PROPOSED GRADE EXISTING FOOTER, SEE NOTE 1 SHEET PILE DIVERSION DAM WITH CONCRETE CAP BENCH EL: 5695.15 (SUPERIMPOSED) FRESNO 54" X 54" SERIES 8200 FABRICATED SLIDE GATE RAISE EXISTING CONCRETE WALL, SEE SHEET XS02 REMOVABLE TRASH RACK AND FISH SCREEN, SEE NOTES GRATE VOID-FILLED RIPRAP (D50 = 18"), 3' THICK FRESNO 30" X 30" SERIES 8200 FABRICATED SLIDE GATE CONCRETE ENTRANCE RAMP AT FLUME, MATCH EXISTING CONCRETE THICKNESS JBH/DTL JBH/DTL SDS 4/26/2024 SHOWN MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 3-BUSINESS DAYS IN ADVANCE CENTER OF COLORADO OR CALL UTILITY NOTIFICATION 1-800-922-1987 811 CALL COLORADO NO.BY DATE COMMENTS SCALE DETAIL CHECK DESIGN Pl o t D a t e / T i m e : 0 4 / 2 5 / 2 0 2 4 , 1 0 : 0 5 : 3 4 P M ; G : \ W W E \ 2 1 1 - 0 2 0 \ 0 2 0 \ C A D \ 0 2 _ D W G S \ P P X X - D I V E R S I O N A N D F I S H P A S S A G E P & P . D W G - P P 0 4 - 2 - R O S E M A N D I V E R S I O N P & P SHEET NO. JOB NO. REVISION NO. DATE DESCRIPTIONWRIGHT WATER ENGINEERS, INC. GLENWOOD SPRINGS, CO 81602 (970)945-7755 FAX(970)945-9210 818 COLORADO AVE. P.O. BOX 219 DRAFT NOT FOR CONSTRUCTION BID SET 4/26/2024 4/26/2024 DIVERSION PLAN & PROFILE 211-020.020 ---- PP02 10 10 20 FT0 0 1010 0 55 VERTICALHORIZONTAL 20 FT 10 FT NORTH PLAN PROFILE NOTES: 1.FOOTER LOCATION SHOWN CONCEPTUALLY ONLY. CONTRACTOR TO LOCATE AND PROTECT FOOTER IN PLACE. 2.REMOVABLE TRASH RACK AND FISH SCREEN STRUCTURE DESIGN TO BE COORDINATED WITH DIVERSION COMPANY. 3.CONTRACTOR TO EVALUATE UNDERCUT SEDIMENT SLUICE IN DRY CONDITIONS WITH ENGINEER PRIOR TO CONSTRUCTING SEDIMENT SLUICE TO DETERMINE BEST APPROACH TO STABILIZING UNDERCUT. CONTRACTOR TO ASSUME PLACEMENT OF STREAM SUBSTRATE BENEATH EXISTING STRUCTURE. 4.BOULDERS ALONG DIVERSION DAM TO BE INSTALLED IN COORDINATION WITH ENGINEER. 5.PLACEMENT OF ALL BOULDERS SHOULD BE REVIEWED AND ACCEPTED BY THE ENGINEER. BOULDERS PLACED WITHOUT ENGINEER APPROVAL ARE SUBJECT TO REMOVAL AND REPLACEMENT. ROSEMAN DIVERSION A SECTION A (NTS) PROPOSED GRADE EXISTING GRADE VOID-FILLED RIPRAP (D50 = 18"), 3' THICK MIX TOP 6" OF VOID-FILLED RIPRAP WITH ON-SITE SOIL AND REVEGETATE WITHIN OVERFLOW CHANNEL MATCH EXISTING GRADE 4' 1H: 1 V (M A X . ) 1H:1V (MAX . ) x x ^ ^ ^ ^ ^ ^ ^ ^ ^ ^^ ^ ^ ^ ^^ ^ ^ ^ ^ ^ ^ ^ ^^ ^ ^ w w w w w w w w w w w w w w w w w ww w w w w 5690 5691 5692 5689 5688 5687 568 9 569 1 569 3 5695 5 6 9 6 5 6 9 5 5 6 9 3 5690 5691 5692 5693 5694 5695 5691 5692 569 9 5700 5701 56 9 5 57 0 2 57 0 3 57 0 4 57 0 5 57 0 6 STREAM SUBSTRATE (D50 = 18"), 3' THICK BOULDERS REVEGETATION: WILLOW STAKES DIVERSION DAM STRUCTURE CONCRETE WALL ELK C R E E K FLOW FLOW 5' WIDE LOW FLOW NOTCH, REMOVE EXISTING WINGWALL IN FRONT OF PROPOSED LOW FLOW CHANNEL EXISTING CONCRETE SEDIMENT SLUICE STRUCTURE TO REMAIN. INSTALL FABRICATED HEADGATE, TELEMETRY, AND ACTUATOR PROPOSED CONCRETE STRUCTURE WITH REMOVABLE TRASH RACK AND FISH SCREEN ROCK VANE ELK CREEK OVERFLOW CHANNEL, SEE SHEET PP04 5692 5691 5693 5694 56 9 5 56 9 5 5694 5689 5690 5690 5689 5695 5696 5 6 9 5 569 6 569 7 56 9 8 569 0 569 1 569 2 5691 5692 5690 56 9 1 5 6 8 9 569 0 569 1 5692 569 3 5 6 9 3 56 9 4 56 9 3 569 2 56 9 1 56 9 2 56 9 3 5 6 9 4 56 9 3 56 9 6 5693 5 6 9 0 5 6 9 0 56 9 5 56 9 6 56 9 7 56 9 8 56 9 4 5695 5696 56 9 5 56 9 4 56 9 6 56 9 8 56 9 4 56 9 5 569 5 569 3 5694 5696 569 7 5699 569 8 POOLS TO BE DEVELOPED BETWEEN BOULDER SILLS FEATURE BOULDER 2+1 0 1+00 2+0 0 56 9 5 56 9 7 56 9 8 5692 5693 EL E V A T I O N , ( F T ) STA. (FT) ROSEMAN - SEDIMENT SLUICE PROFILE 5680 5685 5690 5695 5700 5705 5710 5680 5685 5690 5695 5700 5705 5710 0+75 1+00 2+00 2+50 2.60'7.28' 4.30' EXISTING GRADE 0.9% PROPOSED SEDIMENT SLUICE EXTENSION EXISTING SEDIMENT SLUICE STRUCTURE MATCH EXISTING GRADE STA: 2+03.76 EL: 5693.48 PROPOSED SEDIMENT SLUICE AT EXISTING INVERT ELEVATION INV EL: 5691.51 PROPOSED DIVERSION AT EXISTING INVERT ELEVATION INV EL: 5692.91 STA: 1+12.46 EL: 5693.60 MATCH EXISTING SEDIMENT SLIUICE CONCRETE ELEVATION STA: 1+53.08 EL: 5698.65 STA: 1+12.46 EL: 5691.00 MATCH EXISTING SEDIMENT SLUICE INVERT STA: 1+53.08 EL: 5691.37 STA: 1+77.69 INV. EL: 5692.90 CONCRETE WALL PROPOSED GRADE EXISTING FOOTER, SEE NOTE 1 BOULDERS CONCRETE FOOTER, SEE NOTES REMOVABLE TRASH RACK AND FISH SCREEN, SEE NOTES RAISE EXISTING CONCRETE WALL, SEE SHEET XS02 FRESNO 54" X 54" SERIES 8200 FABRICATED SLIDE GATE STREAM SUBSTRATE (D50 = 18"), 3' THICK BACKFILL WITH STREAM SUBSTRATE UNDERNEATH EXISTING SEDIMENT SLUICE AS FEASIBLE BOULDER WALL SHOWN SUPERIMPOSED BOULDER WALL SHOWN SUPERIMPOSED FRESNO 30" X 30" SERIES 8200 FABRICATED SLIDE GATE CONTRACTOR TO COORDINATE WITH STRUCTURAL ENGINEER ON BEDDING BENEATH SEDIMENT SLUICE JBH/DTL JBH/DTL SDS 4/26/2024 SHOWN MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 3-BUSINESS DAYS IN ADVANCE CENTER OF COLORADO OR CALL UTILITY NOTIFICATION 1-800-922-1987 811 CALL COLORADO NO.BY DATE COMMENTS SCALE DETAIL CHECK DESIGN Pl o t D a t e / T i m e : 0 4 / 2 5 / 2 0 2 4 , 0 8 : 2 5 : 5 0 P M ; G : \ W W E \ 2 1 1 - 0 2 0 \ 0 2 0 \ C A D \ 0 2 _ D W G S \ P P X X - D I V E R S I O N A N D F I S H P A S S A G E P & P . D W G - P P 0 4 - 3 - R O S E M A N R E T U R N F L O W P & P SHEET NO. JOB NO. REVISION NO. DATE DESCRIPTIONWRIGHT WATER ENGINEERS, INC. GLENWOOD SPRINGS, CO 81602 (970)945-7755 FAX(970)945-9210 818 COLORADO AVE. P.O. BOX 219 DRAFT NOT FOR CONSTRUCTION BID SET 4/26/2024 4/26/2024 RETURN FLOW PLAN & PROFILE 211-020.020 ---- PP03 10 10 20 FT0 0 1010 0 55 VERTICALHORIZONTAL 20 FT 10 FT NORTH PLAN PROFILE NOTES: 1.EXISTING FOOTER LOCATIONS TO BE FIELD VERIFIED. CONTRACTOR TO COORDINATE ANY DISCREPANCIES FROM WHAT IS SHOWN ON THESE PLANS WITH ENGINEER. 2.REMOVABLE TRASH RACK AND FISH SCREEN STRUCTURE DESIGN TO BE COORDINATED WITH DIVERSION COMPANY. 3.BOULDERS ALONG DIVERSION DAM TO BE INSTALLED IN COORDINATION WITH ENGINEER. 4.THE INTENT OF THE PROPOSED ROCK FILL DOWNSTREAM OF THE RAMP IS TO CREATE A SERIES OF POOLS TO PROMOTE FISH PASSAGE AND PROVIDE AREAS OF REFUGIA. 5.PLACEMENT OF ALL BOULDERS SHOULD BE REVIEWED AND ACCEPTED BY THE ENGINEER. BOULDERS PLACED WITHOUT ENGINEER APPROVAL ARE SUBJECT TO REMOVAL AND REPLACEMENT. 6.SEE STRUCTURAL PLANS FOR DESIGN OF ALL CONCRETE STRUCTURES. CONTRACTOR SHALL COORDINATE WITH STRUCTURAL ENGINEER ON BEDDING BENEATH CONCRETE STRUCTURES. ROSEMAN DIVERSION x x x x x ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ w w w w w w w w w w w VOID-FILLED RIPRAP (D50=18"), 3' THICK. MIX TOP 6" WITH ONSITE SOIL AND REVEGETATE REVEGETATION: UPLAND SEED EXISTING ROSEMAN DITCH CENTERLINE ROSEMAN - OVERFLOW CHANNEL, SEE PROFILE BELOW5 6 9 9 5 6 9 8 5 6 9 7 5 6 9 6 5 6 9 5 5 6 9 4 5 6 9 9 5 6 9 7 5 6 9 6 5 6 9 6 5 6 9 4 5 6 9 5 56 9 9 56 9 8 56 9 7 56 9 6 56 9 5 56 9 4 56 9 5 5 6 9 7 569 6 5 6 9 5 5 6 9 4 5 6 9 3 5 6 9 2 5 6 9 1 5 6 9 0 5690 56 9 0 56 8 9 5688 5 6 9 4 5695 5696 5695 5 6 9 5 56 9 4 5 6 9 3 5 6 9 2 56 9 1 56 9 0 5 6 8 9 569 1 5 6 9 0 5 6 8 9 569 1 5 6 9 0 5 6 9 1 56 9 2 56 9 1 56 9 0 569 2 1+00 1+85 EXISTING FLUME TO REMAIN, 27.6 CFS IS APROXIMATELY 1.6' OF DEPTH 30.0' WIDE OVERFLOW CHANNEL56 9 4 EL E V A T I O N , ( F T ) STA. (FT) ROSEMAN - OVERFLOW CHANNEL PROFILE 5680 5685 5690 5695 5700 5705 5710 5680 5685 5690 5695 5700 5705 5710 0+85 1+00 2+00 EXISTING GRADE 4:1 0.24% 1.00' VOID-FILLED RIPRAP (D50 = 18"), 3' THICK. MIX TOP 6" WITH ONSITE SOIL AND REVEGETATE PROPOSED GRADE PROPOSED TOP OF OVERFLOW CHANNEL ROSEMAN DITCH CL STA: 1+14.54 EL: 5692.00 MATCH EXISTING GRADE STA: 1+08.67 EL: 5693.94 STA: 1+22.53 INV. EL: 5694.24 STA: 1+51.44 INV. EL: 5694.17 MATCH EXISTING GRADE STA: 1+62.92 EL: 5691.00 VOID-FILLED RIPRAP (D50 = 18"), 3' THICK 4.0' (MIN.) JBH/DTL JBH/DTL SDS 4/26/2024 SHOWN MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 3-BUSINESS DAYS IN ADVANCE CENTER OF COLORADO OR CALL UTILITY NOTIFICATION 1-800-922-1987 811 CALL COLORADO NO.BY DATE COMMENTS SCALE DETAIL CHECK DESIGN Pl o t D a t e / T i m e : 0 4 / 2 5 / 2 0 2 4 , 0 8 : 2 6 : 5 8 P M ; G : \ W W E \ 2 1 1 - 0 2 0 \ 0 2 0 \ C A D \ 0 2 _ D W G S \ P P X X - D I T C H A N D M I S C P & P . D W G - P P 0 4 - P R O J 4 SHEET NO. JOB NO. REVISION NO. DATE DESCRIPTIONWRIGHT WATER ENGINEERS, INC. GLENWOOD SPRINGS, CO 81602 (970)945-7755 FAX(970)945-9210 818 COLORADO AVE. P.O. BOX 219 DRAFT NOT FOR CONSTRUCTION BID SET 4/26/2024 4/26/2024 211-020.020 ---- PP04 ROSEMAN DIVERSION OVERFLOW CHANNEL PLAN & PROFILE 10 10 20 FT0 NORTH PLAN 0 1010 0 55 VERTICALHORIZONTAL 20 FT 10 FT PROFILE A TS02 NOTES: 1.INVERT OF OVERFLOW CHANNEL BASED ON MAXIMUM DITCH CAPACITY PROVIDED BY DITCH COMPANY OF 27.6 CFS. INVERT SET BASED ON CONVEYANCE OF 27.6 CFS AT FLUME. 2.CONTRACTOR TO VERIFY INVERT ELEVATION OF OVERFLOW CHANNEL WITH ENGINEER BASED ON WATER LINE ON FLUME PRIOR TO CONSTRUCTION. EL E V A T I O N , ( F T ) STA. (FT) ROSEMAN - DIVERSION CREST AND CONCRETE WALL SECTION 5680 5685 5690 5695 5700 5705 5710 5715 5680 5685 5690 5695 5700 5705 5710 5715 0+75 1+00 2+00 2+50 2:1 2:1 12.7% EXISTING GRADE 20' 5' REMOVE EXISTING CONCRETE WINGWALL 1.0' ST A : 1 + 2 0 . 0 0 AL I G N M E N T C H A N G E ST A : 1 + 4 5 . 7 1 AL I G N M E N T C H A N G E ST A : 1 + 7 4 . 5 0 AL I G N M E N T C H A N G E STA: 1+07.89 EL: 5698.46 STA: 1+15.89 EL: 5690.00 STA: 1+95.12 EL: 5685.00 STA: 2+05.59 EL: 5699.09 STA: 1+51.58 EL: 5695.15 STA: 1+51.58 EL: 5694.65 STA: 1+46.58 EL: 5698.90 STA: 1+32.75 EL: 5697.90 STA: 1+32.75 EL: 5692.90 STA: 1+46.58 EL: 5685.00 STA: 1+07.89 EL: 5698.90 STA: 1+07.89 EL: 5694.00 STA: 2+13.31 EL: 5694.09 STA: 2+13.31 EL: 5699.09 STA: 1+46.58 EL: 5690.00 STA: 1+46.58 EL: 5694.65 TRASH RACK AND FISH SCREEN STRUCTURE SHEET PILE WALL WITH CONCRETE CAP RAILING BOULDERS SHOWN SUPERIMPOSED FOR REFERENCE FOOTER, SEE STRUCTURAL x x xx x ^ ^ ^ ^ ^ w w w w w w w EL K C R E E K FL O W 57 0 5 57 0 5 57 1 0 5 7 1 0 57 1 5 57 1 5 5720 5 7 2 0 5725 5 7 2 5 5698 56975696 569 5 569 4 56 9 9 5 7 0 0 569 3 5693 5694 5695 5696 5 6 9 7 57 0 0 5 6 9 9 5 6 9 8 56 9 7 56 9 6 56 9 5 56 9 4 5 6 9 4 56 9 5 5 6 9 5 56 9 6 56 9 7 5 6 9 8 56 9 9 5 7 0 0 5 7 0 1 5 7 0 2 57 0 3 5 7 0 4 5 6 9 7 5 6 9 8 5 6 9 9 57 0 0 57 0 1 57 0 2 5 6 9 5 5 6 9 3 5 6 9 5 5 6 9 8 5694 5 6 9 3 5 6 9 2 5 6 9 1 5 6 9 4 5693 5 7 0 0 56 9 9 5 6 9 8 5 6 9 7 5 6 9 6 5 6 9 5 56 9 4 5 6 9 3 5 6 9 4 REMOVABLE TRASH RACK AND FISH SCREEN REVEGETATION: WILLOW STAKES STREAM SUBSTRATE (D50 = 18"), 3' THICK ROCK VANE, SEE SHEET DT01 ROSEMAN - DIVERSION CREST AND CONCRETE WALL SECTION RAILING, SEE PROFILE BELOW 1+00 2+0 0 2+1 6 1 + 0 0 JBH/DTL JBH/DTL SDS 4/26/2024 SHOWN MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 3-BUSINESS DAYS IN ADVANCE CENTER OF COLORADO OR CALL UTILITY NOTIFICATION 1-800-922-1987 811 CALL COLORADO NO.BY DATE COMMENTS SCALE DETAIL CHECK DESIGN Pl o t D a t e / T i m e : 0 4 / 2 5 / 2 0 2 4 , 0 8 : 2 9 : 0 3 P M ; G : \ W W E \ 2 1 1 - 0 2 0 \ 0 2 0 \ C A D \ 0 2 _ D W G S \ X S X X - S E C T I O N S . D W G - X S 0 1 - P R O J 4 SHEET NO. JOB NO. REVISION NO. DATE DESCRIPTIONWRIGHT WATER ENGINEERS, INC. GLENWOOD SPRINGS, CO 81602 (970)945-7755 FAX(970)945-9210 818 COLORADO AVE. P.O. BOX 219 DRAFT NOT FOR CONSTRUCTION BID SET 4/26/2024 4/26/2024 SECTIONS 211-020.020 ---- XS01 10 10 20 FT0 NORTH PLAN 0 1010 0 55 VERTICALHORIZONTAL 20 FT 10 FT PROFILE ROSEMAN DIVERSION NOTES: 1.DEMOLITION AND CUTTING OF EXISTING CONCRETE WALL TO BE COORDINATED WITH ENGINEER. 2.BOULDERS ALONG SHEETPILE CUTOFF WALL SHALL BE PLACED SUCH THAT INTERSTITIAL SPACE IS SET AT TOP OF WALL ELEVATION. 3.SHEETPILE SHALL BE PZ-22 OR APPROVED EQUIVALENT. SEE STRUCTURAL DETAILS. 4.REFER TO STRUCTURAL SHEETS FOR ALL STRUCTURE DETAILS.