HVAC Load Calculations
Tito Ruiz & Aide Mireya Residence HVAC Load Calculations for Tito Ruiz & Aide Mireya 353 West Orchard Avenue sitt, co 81652 J RH1TAC RX*TNNFTTTAh FwAfr Ls*nE \'= 5q Prepared By: Fritz Diether Frostbusters & Coolth Co. PO Box 94 Basalt CO 81621 274-1141 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D Wednesday, July 24, Rhvac - Frostbusters & Coolth Co. Comrnercial HVAC Loads s Elite Software Tito Rliz & Aide Mireya Residence ? cf Re General Project Title: Designed By: Project Date: Project Comment: Client Name: Client Address: CIient City: Client Phone: Client E-MailAddress: Company Name: Company Representative Company Address: Company City: Company Phone: Company E-MailAddress Company Website: Company Comment: Tito Ruiz & Aide Mireya ManualJ By Fritz Diether July 24,2024 833 County Rd 331, Silt, CO 81652 Tito Ruiz & Aide Mireya 353 West Orchard Avenue sitt, co 81652 970-61 8-9469 titosha ndymanservice@yahoo. com Frostbusters & Coolth Co, Fritz Diether PO Box 94 Basalt CO 81621 (970) 274-1141 fritzd@frostbusters. com frostbusters.com Lot 2, Ruiz South Minor Subdivision Reference City: Building Orientation: Daily Temperature Range: Latitude: Elevation: Altitude Factor: Elevation Heating Adj. Factor: Silt, Colorado Front door faces South High 39 Degrees 5520 ft 0.816 0.840 \*_ Outdoo Outdoor Drv Bulb Outdoor Rel=Flum nla 28o/o lndoor Rel.Hum nla 40% lndoor Drv Bulb 72 75 Grains Difference nla 0 Winter: Summer: -2.73 62 -2 Check Total Building Supply CFM Square ft. of Room Area: Volume (ft3): 480 1,197 12,159 CFM Per Square ft. Square ft. Per Ton: 0.401 1,402 Total Heating Requ Total Sensible Gain Total Latent Gain: lncluding Ventilation Air:Btuh 8,840 Btuh 1,407 Btuh 10,247 Btuh 16.438 MBH (Based On 0.840 Derating) 86 o/o 14 o/o 0.85 Tons (Based On Sensible + Latent)Total Cooling Required lncluding Ventilation Air: Rhvac is an ACCA ap Manual J, D and S computer program Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. \1 0.2.152.1 O\public ...\Tito 833 Cou ... -24-2024.rh9 Wednesday, July 24,2024,6:17 PM Miscellaneous Summer:86 62 28To nla 40o/o 72 75 0,21 Calculate: Use Schedule: Roughness Factor: Pressure Drop: Minimum Velocity: Maximum Velocity: Minimum Height: Maximum Height: Yes Yes 0.00500 0.1000 in.wg./100 ft. 650 ft./min 900 ft./min 0 in. 0 in. Runouts Yes Yes 0.00030 0.1000 in.wg./100 ft. 450 ft./min 750 ft./min0 in.0 in. I nfiltration Specified: Winter 0.331 AC/hr 67 CFM 10.50 30 AC/hr CFM lnfiltration Actual Building Volume: Total Building lnfiltration: Total Building Ventilation: 0.147x 12.159 1,788x 0.0167 30 60 0.000 AC/hrX 12.159 Cu.ft. 0 Cu.ft./hrx 0.0167 O CFM 60 CFM AC/hr Cu.ft. Cu.ft./hr CFM CFM --System 1-- lnfiltration&VentilationSensibleGainMultiplier: 9.87 = (1.10X0.816X11.00SummerTemp.Difference) lnfiltration & Ventilation Latent Gain Multiplier: 0.12 = (0.68 X 0.816 X0.21Grains Difference) lnfiltration&VentilationSensibleLossMultiplier: 66.42 = (1.10X0.816X74.00WinterTemp.Difference) Winter lnfiltration Specified: 0.331 AC/hr (67 CFM) Summer lnfiltration Specified: 0.150 AC/hr (30 CFM) Blower Door Data: Wind Shielding Class: 2 - Few Obstructions Building Stories: 2 Multi/Single Option: Single-Point Assumed n: 0.65 Pressure Diff.: 50 Test Flow: 608 Test AC/hr (Selected): 3 \1 0.2. 1 52. 1 O\public ...\Tito 833 Cou ... -24-2024.rh9 Wednesday , July 24,2024,6:17 PM Load Preview ort s)E Acl CFM Ducl Size Nel Tm tr /Ion Area Ser Gain Lal Gain Sen Loss"",1cainI slp Hb CFM qF clg CFMScope 8,w', 8,840 iiisi e,azl:, 91Sj 294 1,201 1,789i 1,297' 2:028. 320, 777: a 480. 51, 16 67' 100 72 113 16 224 '189, ,239 't01 73i 7-Master Bafl Building 2261 0. &Mud/l-aundry 1't3 1,400. fi,A21 1&,, 80:100 390 10,247: 1 spbm roomairforu uses tte 1.197 Sum of rcom airfrows may be greabr fian sysbm airf ou because or 196 480, 480i 1:t97i 1,197: 1107 '1,407 7: 13,808, r,ciit 12333i 1,U7 /p,8, 1,M7: 3,081 1,760 200 200 18 18. 1 43431 1,989, 1Ae7i 400 2,428 2,233 36 150 470 392, 6 150 927. 1,125: 18 \,bntilation Zonel 1-Bedroom 1 2-Bafr lBedrmm2 4-Dining/l-iving $MasterBedroom &Kbher/Dining 196: 480: 'l 196. 4S0 26 51 7 16, \\1 0.2. 1 52. 1 O\public ...\Tito 833 Cou ... -24-2024.rh9 Wednesday, July 24,2024,6:17 PM Duct Size Preview Lengfr Hg clg Act Duct Reg SizeLoss Room or DuctName Source Built-ln- Builtln Built-ln Builtln Built-ln Built-ln Built-ln Built-ln Built-ln BuiltJn 450 450 450 450 450 450 450 450 450 450 750 750 750' 750 750 750: 750 750, 750, 750 0.1 0.1 0.1 0.1 0.1, 0.'l 0.1 0.1 5_851 , 1852, 490.8: 5076 530: 575.4' 204.3 495.8 0 6' z0 11,,11fi$$i 7 llliliii:ililil6i 26 1,,.:,;,!.:ffi. +s=ii$ Ze -=,,:.!t SO,::t:.-:#3, 6 l;.:i::i'r:li$ 18 lii';':.llr:{g 0'iiii:ri:;.::,l S o l::;:::;:;,1,;t,$ 51 16 67 100 72 113 18 43 0 14 14 1-5, 1-6, 1-5 1-6 14, 14 0-0 0-0 TMDD 0 0.0003 0.08.1: 196 480 8x1 3Trunk $Bbm1 0.0003. 0.0003, 0.0003' 0.0003 0.0003. 0.0003 0.0003 0.0003 0.0003, 0.0003 Gl(bheilDining 7-MasbrBah &Mud/Laundry 9.Garage 1o-Garage other Ducts in SlEtem I Supply Runouts Zonel 1-Bedroom 1 2-Bafi $Bedroom 2 4Dining/Living $MasbrBedroom Heating Floiv: 196 $Pem 1 Flotar: 480 \1 0.2. 1 52. 1 0\public ...\Tito 833 Cou ... -24-2024.rh9 Wednesday, July 24,2024,6:17 PM S m 1 - Boiler/Eva Cooler - Ade uate re Iesf Test For Adequate Exposure Diversity 15, 10 ! f m i'6 (, ooI 55.2o/o Diff. from Avg. (541 Btuh Excursion) 0 8 am 9am 10am 11 am 12pm 1 pm 2pm 3pm 4pm 5pm 6pm 7pm ,',' Average Glass Sensible Gain Over 12 Hours ,,,' 1.3 x Average Glass Gain / Hourly Glass Gain / Hourly Total Net Gain SYSTEM DOES NOT HAVE ADEQUATE EXPOSURE DIVERSITY System is on N, E, S, W rosette. Peak load exceeds 12-hour average load by 55.2o/o. AED Excursion (amount by which peak exceeds 1.3 x average): 541 Btuh Definition: A system has adequate exposure diversity if the peak-hour glass load for the entire conditioned space does not exceed the averaoe qlass load for the entire conditioned space bv more than 30 percent. \1 0.2. 1 52. 1 0\public ...\Tito 833 Cou ... -24-2024.rh9 Wednesday, July 24,2024,6:17 PM , \\'10.2.152.10\public...\Tito833Cou ...-24-2024.rh9 Wednesday, July 24,2024,6:17 PM Rhvac - Residential & Light Frostbusters & Coolth Co. Elite Tito Ruiz & Aide Mireya Residence Basal co 81621 ?a 7 Total Buildi Summa Loads Sen Loss Sen Gain Total GainQuan Windsor Vin 25124 g-Windsor Windows & Doors 60 55.5 21 30 10 6.2 21 892.8 244.2 177 1 196.8 1 196.8 1,110 985 466 688 185 111 368 2,179 1,391 204 1,772 894 519 888 151 132 519 888 151 132 Vinyl Frame .251.24, U-value 0.25, SHGC 0.24 Windsor Vin 24118: Glazing-Windsor Windows & Doors Vinyl Frame .241.18, U-value 0.24, SHGC 0.18 Fibrglass Door 30/20: Glazing-Fiberglass Frame, LowE, Full Lite Entry Door, U .30 / SHGC .20, U-value 0.3, SHGC 0.2 Windsor Vin 31125: Glazing-Windsor Windows & Doors Vinyl Frame .31/.25, U-value 0.31, SHGC 0.25 Windsor Vin 25118: Glazing-Windsor Windows & Doors Vinyl Frame .251.18, U-value 0.25, SHGC 0.18 Windsor Vin 24124: Glazing-Windsor Windows & Doors Vinyl Frame .241.24, U-value 0.24, SHGC 0.24 Gar/Hs Fire Door: Door-Garage/House Fire Door R-2, U- value 0.5 R-30 Foam& BIB: Wall-Frame, Custom, R-30 - R-15 Spray Foam + R-15 BIB Fiberglass, U-value 0.033 Spray Foam 3.2" R-21: Wall-Frame, Custom, Spray Foam 3.2", R-21,2x4x24, U-value 0.077 R-30 Foam& BIB: Part-Frame, Custom, R-30 - R-15 Spray Foam + R-15 BIB Fiberglass, U-value 0.033 R49 Blown Attic: Roof/Ceiling-Under Attic with lnsulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Custom, R-49 Blown Cellulose or Fiberglass Attic, U-value 0.02 R19 Fiberglass Fdn: Floor-Over enclosed crawl space, Custom, R-19 Fiberglass on Foundation Wall - Sealed CrawlSpace, U-value 0.045 0 0 0 0 0 0 0 0 0 0 249 63 46 263 186 284 146 983 249 63 46 263 186 284 146 983 0 Subtotals for structu re: People: Equipment: Lighting: Ductwork: lnfiltration: Winter CFM: 30, Summer CFM: 0 Ventilation: Winter CFM: 60, Summer CFM: 60 AED Excursion: 10,353 0 800 600 3,910 920 3,250 0 0 0 219 541 3,910 1,720 3,850 0 0 0 226 541 4 0 0 1,980 1,475 0 0 0 7 0 Total Building Load Totals:13,808 1,407 8,840 10,247 Total Building Supply CFM Square ft. of Room Area: Volume (ft3): 480 1,197 12,159 CFM Per Square ft. Square ft. Per Ton: 0.401 1,402 Buildin Loads Total g uired lncluding Ventilation Air:16,438 Btu 16.438 MBH (Based On 0.840 Derating) 86% 14 o/o 0.85 Tons (Based On Sensible + Latent) TotalSensible Gain: Total Latent Gain: Total Cooling Required lncluding Ventilation Air: 8,840 Btuh 1,407 Btuh 10,247 Bluh Rhvac is an approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. Buildins Pie Chaft Floor 6 entilation 1 1% Roof 13 nfiltration 14% Building Loss 13,BOB Btuh Door 3% Wall 27% Glass 26% oor 1 ED ron 5o/o 2%Roof 10 e n o n Wall 6% Building Gain 10,247 Btuh Glass 19 quipment 38% People 17o/o \1 0.2.152.1O\public ...\Tito 833 Cou ... -24-2024.rh9 Wednesday, July 24,2024,6:17 PM s 1-Hou Room Net Gain System 1 Hourly Room Net Gain 2,800 2,600 2,400 2,200 2,000 1,800 1,600 1,400 1,200 1,OOO 800 600 400 2o0 8am 9am lOam 11 am 12Pm 1pm 2pm Tlme of Day 3pm 4pm spm 6pm 7pm fr I 2 o -*-61** Bedroom 1 (42o/o) Bath (23old Bedroom 2 (3oold Dining/ Living (25Yd Master Bedoom (28Vd Kitchen/Dining (3Yd Master Bath (O9lo) Mud/ Laundry (syd ***+<t* Garaqe O9r'o) Note: Glass gain as a percent of net gain is shown in parenthesis. Although floor, roof, wall and door gains also vary throughout the day, for this graph and in Manual J glass gains are the only ones that fluctuate. \\1 0.2. 1 52. 1 O\public ...\Tito 833 Cou .,. -24-2024.rh9 Wednesday, July 24,2024, 6:17 PM Detailed Room Loads - Room 1 - Bedroom 1 Load Procedure Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: 13.3 ft. 11.0 ft. 145.8 sq.ft. Occurrences: System Number: Zone Number: Supply Air: Supply Air Changes: Req. Vent. Clg: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent. Percent of Supply: ActualWinter lnfil.: ActualSummer lnfil.: 1 1 1 51 2.3 0 8 16 o 12 4 0 CFM AC/hr CFM CFM oa CFM o/o CFM CFM 9.0 1,312 1 51 4 ft. cu.ft. c FM tn. 586 ft./min. 586 ft./min. 0.155 in.wg./100 ft. W -Wall-R-30 Foam& BIB 11 X 9 N -Gls-\Mndsor Vin 25D4 shgc- 0.24100To5 W -Gls-Windsor Vin 24118 shgc- 0.18 0%s UP-Ceil-R49 Blown Attic 145.8 X 1 Floor-R19 Fiberqlass Fdn 1 X 145.8 99.2 87 20 0.033 0.033 0.250 2.4 2.4 18.5 242 212 370 0.2 7.5 0 0 0 0 0 18 149 12 0.240 17.8 213 19.7 236 145.8 145.8 0.020 0.045 1.5 0.7 216 't09 0.8 0.1 120 16 Subtotals for Structure: lnfil.: Win.: 4.3, Sum.: 0.0 AED Excursion: Equipment: 218 1.306 1,362 285 0.000 0 0 0 560 0 58 300 Room Totals 1,647 0 918 \\1 0.2. 1 52. 1 O\public ...\Tito 833 Cou ... -24-2024.rh9 Wednesday, July 24,2024,6:17 PM RuizTito Aide& 1 Detailed Room Loads - Room 2 - Bath (Average Load Procedure) , Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 13.3 ft. System Number: I Room Width: Area: Ceiling Height: Volume: Number of Registers Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: 6.0 79.5 9.0 716 1 16 4 ft. sq.ft. ft. cu.ft. Zone Number: Supply Air: Supply Air Changes: Req. Vent. Clg: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent. 1 16 CFM 1.4 AClhr O CFM 2 CFM 13% 2 CFM 12 o/o 1 CFM O CFM CFM in. 185 ft./min. Percent of Supply: 185 ft./min. ActualWinter lnfil.: 0.020 in.wg./100 ft. Actual Summer lnfil. W -Wall-R-30 Foam& BIB 6 X 9 W -Gls-Windsor Vin 24118 shgc- 0.18 0%s UP-Ceil-R49 Blown Attic 79.5 X 1 Floor-R19 Fiberqlass Fdn 1 X 79.5 49.5 4.5 0.033 0.240 2.4 17.8 121 80 0.2 19.6 0 0 0 0 10 88 79.5 79.5 0.020 0.045 1.5 0.7 118 59 0.8 0.1 65 I Subtotals for Structure: lnfil.:Win.: 1.1, Sum.: 0.0 AED Excursion: Equipment: 54 1.296 378 70 0.000 0 0 172 0 18 100100 Room Totals 448 100 290 \1 0.2.'152.10\public ...\Tito 833 Cou ... -24-2024.rh9 Wednesday, July 24,2024,6:17 PM 12 Mireya & Co.Frostbusters & co 81 Detailed Room Loads - Room 3 - Bedroom 2 (Average Load Procedure) Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 13.3 ft. System Number: 1 Room Width: 11.0 ft. Zone Number: 1 Area: 145.8 sq.ft. Supply Air: 67 CFM Ceiling Height: 9.0 ft. Supply Air Changes: 3.1 AC/hr Volume: 1,312 cuJt. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 8 CFM Runout Air: 67 CFM Percent of Supply.: 12 o/o Runout Duct Size: 5 in. Actual Summer Vent.: 8 CFM Runout Air Velocity: 491 ft./min. Percent of Supply: 12 o/o Runout Air Velocity: 491 ft./min. Actual Winter lnfil.: 4 CFM Actual Loss: 0.085 in.wg./100ft. ActualSummer lnfil.: 0 CFM S -Wall-R-30 Foam& BIB 13.2 X 9 W -Wall-R-30 Foam& BIB 11 X 9 S -Gls-Windsor Vin 25124 shgc- 0.24 620/o5 W -Gls-Windsor Vin 24118 shgc- 0.18 0%s UP-Ceil-R49 Blown Attic 145.8 X 1 Floor-R19 Fiberqlass Fdn 1 X 145.8 87 20 0.033 0.033 0.250 2.4 2.4 18.5 242 212 370 0.2 0.2 9.3 0 0 0 0 0 0 21 18 185 12 0.240 17.8 213 19.7 236 145.8 145.8 0.020 0.045 1.5 0.7 216 109 0.8 0.1 120 16 Subtotals for Structu re: lnfil.: Win.:4.3, Sum.: 0.0 AED Excursion: People: 200 laVper, 230 sen/per: Equipment: 218 1.306 1,362 285 0.000 0 0 596 0 75 230 300 I 200 0 Room Totals 1,647 200 1,201 \1 0.2.152.1O\public ...\Tito 833 Cou,.. -24-2024lh9 Wednesday, July 24,2024, 6'.17 PM Loads Developrnent lnc, Tito Ruiz & Aide Mireya Residence 13 & Light Gommercial Frostbusters & Coolth Co. co 81621 Detailed Room Loads - Room 4 - Dining/Living (Average Load Procedure) Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: Htg. & clg. 16.0 14.0 224.0 12.0 2,688 1 rrences 1 I 1 100 2.2 0 15 15 12 12 5 0 ft. ft. sq.ft. ft. cu.ft. System Number: Zone Number: Supply Air: Supply Air Changes: Req. Vent. Clg: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent. Percent of Supply: ActualWinter lnfil.: Actual Summer lnfil.: CFM AC/hr CFM CFM o/o CFM To CFM CFM 100 cFM 6 in. 508 ft./min. 508 ft./min. 0.072 in.wg./100 ft E -Wall-Spray Foam 3.2" R-21 14 X 4 S -Wall-R-30 Foam& BIB 16 X I W -Wall-Spray Foam 3.2" R-21 14 x4 S -Gls-Fibrglass Door 30/20 shgc- 0.2 100%s S -Gls-Windsor Vin 31/25 shgc- 0.25100%s S -Gls-Windsor Vin 24118 shgc- 0.18100%s UP-Ceil-R49 Blown Attic 224 X I Floor-R19 Fiberglass Fdn 1X224 56 78 56 21 30 15 77 5.7 2.4 5.7 22.2 22.9 17.8 319 190 319 466 688 266 332 167 1.2 0.2 1.2 7.2 8.3 6.1 0.8 0.1 0 0 0 0 0 0 0 0 65 16 65 151 249 92 184 25 224 224 0.033 0.077 0.300 0.310 0.240 0.020 0.045 1.5 0.7 Subtotals for Structure: lnfil.:Win.: 5,0, Sum.: 0.0 AED Excursion: People: 200 laVper, 230 sen/per: Equipment: 256 1.305 2,747 334 0.000 0 0 847 0 112 230 600 200 0 Room Totals:3,081 200 1,789 \'1 0.2.152.10\public ...\Tito 833 Cou ... -24-2024:h9 Wednesday, July 24,2024, 6:17 PM Elite Software Tito Ruiz &Aide co 81621 Detailed Room Loads - Room 5 - Master Bedroom vera Load Procedure Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: Htg &clg Occurrences: System Number: Zone Number: Supply Air: Supply Air Changes: Req. Vent. Clg: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent. Percent of Supply: ActualWinter lnfil.: Actual Summer lnfil.: 1 1 1 72 nla nla 88.8 sq.ft. ft. cu.ft. CFM AC/hr CFM CFM o/o CFM o/o CFM CFM 9.0 1,699 1 72 5 530 530 0.098 2.6 0 9 2 I 2 5 0 CFM in. ft./min. ft./min. in.wg./100 ft E -P art-25' 135'-R-30 Foa X9 BIB 72 0.033 1.2 0.8 0 0 0 0 0 0 0 E -Wall-R-30 Foam& BIB 6 X 9 S -Wall-R-30 Foam& BIB 13.5 X I E -Gls-Windsor Vin 24118 shgc- 0.18 0%s S -Gls-Wndsor Vin 25124 shgc- 0.24 62%3 UP-Ceil-R49 Blown Attic 188.8 X 1 Floor-R19 Fiberglass Fdn 1 X 188.8 42 101 .5 12 0.033 0.033 0.240 2.4 2.4 17.8 103 248 213 0.2 0.2 19.7 I 21 236 20 0.250 18.5 370 9.3 185 188.8 188.8 0.020 0.045 1.5 0.7 279 141 0.8 0.'1 155 21 Subtotals for Structure: lnfil.: Win.: 4.9, Sum.: 0.0 AED Excursion: People: 200 lat/per, 230 sen/per: Equipment: 248 1.305 1,437 323 0.000 0 0 686 0 81 230 300 1 200 0 Room Totals:1,760 200 1,297 \10.2.152.10\public ...\Tito 833 Cou ... -24-2024.rh9 Wednesday, July 24,2024,6:17 PM Detailed Room Loads - Room 6 - Kitchen/Din Load Procedure Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: nla nla 238.6 12.0 2,863 1 113 b 575 575 0.090 sq.ft. ft. cu.ft. Occurrences: System Number: Zone Number: Supply Air: Supply Air Changes: Req. Vent. Clg: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent. Percent of Supply: ActualWinter lnfil.: Actual Summer lnfil.: 1 1 113 CFM 2.4 AClhr O CFM 11 CFM 10 o/o 14 CFM 12 o/o 6 CFM O CFM CFM in. ft./min. ft./min. in.wg./100 ft. N -Wall-R-30 Foa 154.2 26 20.2 30 56 10 238.6 238.6 0.033 0.077 0.077 0.077 0.077 0.250 0.020 0.045 2.4 5.7 5.7 5.7 5.7 18.5 1.5 0.7 0 0 0 0 0 0 0 0 32 30 24 35 65 63 E -Wall-Spray Foam 3.2" R-21 6.5 x4 S -Wall-Spray Foam 3,2" R-212.2 X9 E -Wall-Spray Foam 3.2" R-21 7.5 x4 W -Wall-Spray Foam 3.2" R-21 14 x4 N -Gls-Windsor Vin 25118 shgc- 0.18100o/oS UP-Ceil-R49 Blown Attic 238.6 X 1 Floor-R19 Fiberqlass Fdn 1 X 238.6 148 115 171 319 185 353 178 1.2 1.2 1.2 1.2 6.3 0.8 0.1 196 26 Subtotals for Structure: lnfil.:Win.: 5.8, Sum.: 0.0 AED Excursion: People: 200laUper, 230 sen/per: Equioment: 297 1.305 1,846 387 0.000 0 0 471 0 127 230 1.200 1 200 200 Room Totals:2,233 400 2,028 \1 0.2. 1 52. 1 0\public ...\Tito 833 Cou ... -24-2024.rh9 Wednesday, July 24,2024, 6:17 PM ivac -te Ruiz & Aide Detailed Room Loads - Room 7 - Master Bath VE e Load Procedure Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: Htg. & clg. 13.5 ft. Occurrences: System Number: Zone Number: Supply Air: Supply Air Changes: Req. Vent. Clg: ActualWinter Vent.: Percent of Supply.: Actual Summer Vent Percent of Supply: ActualWinter lnfil.: Actual Summer lnfil.: I 1 1 8 2 0 2 1 2 2 I 0 7.5 ft. 101 .3 sq.ft. 9.0 ft. 911 cu.ft. 1 18 CFM 4 in. 204 fl.lmin. 204 fl.lmin. 0.024 in.wg./100 ft. 1 CFM AC/hr CFM CFM o/o CFM Yo CFM CFM 1 1 1 -R-30 Foam& BIB 67.5 0.033 0 0 0 7.5X9 UP-Ceil-R49 Blown Attic 101.2X 1 Floor-R19 Fiberqlass Fdn 1 X 101.2 101.2 101.2 0.020 0.045 1 5 7 150 76 0.8 0.1 83 110. Su btotals for Structure: lnfil.:Win.: 1.3, Sum.: 0.0 AED Excursion: Equipment: 304 0 0 150 0 2A 150 68 1.304 88 0.000 150 Room Totals:392 150 320 \1 0.2.1 52.1 0\public ...\Tito 833 Cou ... -24-2024.rh9 Wednesday, July 24,2024,6:17 PM Coolth 621co Mireya&Ruiz ResidenceAide Detailed Room Loads - Room I - Mud/Laundry (Average Load Procedure) . ot,,=ri', , Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 11.3 ft. System Number: I Room Width: 6.5 ft. Zone Number: 1 Area: 73.1 sq.ft. Supply Air: 43 CFM Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: 9. 65 4 0 ft. 8 cu.ft. 1 3 CFM 4 in. Supply Air Changes: Req. Vent. Clg: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent. Percent of Supply: ActualWinter lnfil.: ActualSummer lnfil.: 3.9 AC/hr O CFM 5 CFM 13 o/o 5 CFM 12 o/o 3 CFM O CFM 496 ft./min. 496 ft./min. 0.1 15 in.wg./'100 ft. N -Wall-R-3O Foam& BIB 11.2 X 9 E -Part-25"135'-R-30 Foam& BlB 6.5X9 E -Door-Gar/Hs Fire Door 3 X 7 N -Gls-Windsor Vin 24124 shgc- 0.24100%s UP-Ceil-R49 Blown Attic 73.1 X 1 Floor-R19 Fiberglass Fdn 1 X 73.1 95 37.5 0.033 2.4 1.2 232 43 0.2 0.8 0 0 0 0 0 0 20 31 21 6.2 0.500 0.240 17.5 17.8 368 111 12.5 7.4 263 46 73.1 73.1 0.020 0.045 1.5 0.7 108 55 0.8 0.'l 60 8 Subtotals for Structure: lnfil.: Win.: 3.1, Sum.: 0.0 AED Excursion: Equipment: 160 1.302 917 208 0.000 0 0 428 0 49 300150 Room Totals:1J25 150 777 \1 0.2.152.10\public ...\Tito 833 Cou ... -24-2024.rh9 Wednesday, July 24,2024, 6:17 PM S m 1 Room Load Summa --Zone 1-- 1 Bedroom 1 2 Bath 3 Bedroom 2 4 Dining/Living 5 Master Bedroom 6 Kitchen/Dining 7 Master Bath 8 Mud/Laundry 146 80 146 224 189 239 101 73 1,647 448 1,647 3,081 'l ,760 2,233 392 1,125 26 7 26 49 28 36 6 18 1-4 14 1-5 1-6 1-5 1-6 1-4 14 586 185 491 508 530 575 204 496 918 290 1,201 1,789 1,297 2,028 320 777 0 100 200 200 200 400 150 150 51 16 67 100 72 113 18 43 51 16 67 100 72 113 18 43 Ventilation 1,475 219 7 Svstem 1 total 1.197 13.808 196 8,840 1.407 480 480 System 1 Main Trunk Size: Velocity: Loss per 100 ft.: 8x13 in. 665 ft./min 0.095 in.wg ired:0.85 1.50 8,840 1,407 Actual 18,000 Type: Model: lndoor Model: Brand: Efficiency: Sound: Capacity: Sensible Capacity Latent Capacity: NaturalGas Boiler Water Cooled Chiller 95 AFUE 0 60,000 Btuh nla nla 12.2EER 0 18,000 Btuh 0 Btuh 0 Btuh This system's equipment was selected in accordance with ACCA Manual S. Manual S equipment sizing data: SODB: 86F, SOWB: 62F, WODB: -2F, SIDB: 75F, SIRH: 407o, WDB: 72F, Sen. gain: 8,840 Btuh, Lat. gain: 1,407 Btuh, Sen. loss: 13,808 Btuh, Entering clg. coilDB: 76.4F, Entering clg. coilWB:58.9F, Entering htg. coil DB:63.6F, Clg. coilTD: 20F, Htg. coilTD: 70F, Req. clg. airflow: 480 CFM, Req. htg. airflow: 196 CFM \10.2.152.10\public ...\Tito 833 Cou ... -24-2024.rh9 Wednesday, July 24,2024,6:17 PM Rhvac - Residential 6 Softlarare Frostbusters & Coolth Co Tito Ruiz & Aide Mireya Residence co 1 Radiant Floor Re ort 1-Bedroom I 2-Bath 3-Bedroom 2 4-Dining/Living 5-Master Bedroom 6-Kitchen/Dining 7-Master Bath 8-Mud/Laundry 112" PEX Therma-Floor 125,el 112" PEX Therma-Floor [25,e] 112" PEX Therma-Floor [25,e] 112" PEX Therma-Floor t25,91 112" PEX Therma-Floor [25,e] 112" PEX Therma-Floor [25,e] 112" PEX Therma-Floor [25,e] 112" PEX Therma-Floor 125,el 146 80 146 224 189 239 101 73 1,647 448 1,647 3,081 1,760 2,233 392 1,125 88 24 88 164 94 119 21 60 163 84 163 260 216 278 110 76 3,065 1,567 3,065 4,877 4,057 5,218 2,053 1,426 -1,418 -1,119 -1,418 -1,796 -2,297 -2,985 -1,661 -301 System 1 Total 1,197 12,333 658 1,351 25,328 -12,995 Area values shown include only those rooms for which radiant floor properties have been entered. Sensible heat loss values on this report do not include losses associated with duchryork, ventilation, winter humidification or hot water piping. Tubing lengths include only the tubing that is part of the radiant floor panel itself and not the supply and return piping to and from the manifold. Tubing lengths are calculated from the Tubing Spacing input and an assumed installed coverage area that is based on a 6-inch offset from each wall around the perimeter of a rectangular room. The Floor Heat Output Btuh values shown are calculated with the assumption that the tubing is installed to fill the room at the given spacing. lf the Supplemental Heat Required is negative, the radiant floor output exceeds the sensible loss of the room by the indicated amount, assuming that the tubing is installed to fill the room at the given spacing. \1 0.2.152.10\public ...\Tito 833 Cou ... -24-2024:h9 Wednesday, July 24,2024,6:17 PM