HomeMy WebLinkAboutCondition of Permit1)
2)
3)
CONDITIONS OF PE RMIT
B LRE-10-24-8930
BRUCE ARBANEY
New Single-family dwelling w/ attached garage
580 Mesa Dr, Rifle
Rifle Creek Est Amended, Lot 1 1
ALL WORK SHALL COMPLY WITH THE 2015 INTERNATIONAL RESIDENTIAL CODE (I.R.C.)AND 2018
I NTERNATIONAL EN ERGY CONSERVATION CODE ( I.E.C.C.)
PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE
ATTACHED "GARFIELD COUNTY BUILDING REOUIREMENTS". NUMBER REFERENCES NOTED ON
PLANS REFER TO SPECIFIC ITEMS ON THIS LIST.
ELECTRICAL PERMITTING AND INSPECTIONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL
ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS
REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY.
ALL EXTERIOR LIGHTING TO BE DOWNCAST AND SHIELDED.
WILDFIRE MITIGATION RECOMMENDATIONS: SHOULD COMPLY WITH WILDFIRE MITIGATION AND
DEFENSIBLE SPACE RECOMMENDATIONS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE
DISTRICT. PLEASE REFER TO THE GARFIELD COUNTY COMMUNITY DEVELOPMENT WEBSITE FOR
ADDITIONAL I N FORMATION.
SEPTIC SYSTEM REVIEW / APPROVALS: PRIOR TO BUILDING INSPECTION & CERTIFICATE OF
OCCUPANCY PROVIDE FINAL APPROVAL/SIGN-OFF FROM GARFIELD COUNTY'S PUBLIC HEALTH
DEPT.
OPEN HOLE SOILS REPORT IS REOUIRED AT FOOTING INSPECTION AND PRIOR TO ANY CONCRETE
POUR. PROVIDE COPY OF GEOTECHNICAL ENGINEERS REPORT TO THE BUILDING INSPECTOR.
1,500 PSF soil bearing.
PRE-ENGINEERED ROOF TRUSSES. HAVE ENGINEERING FOR BUILDING INSPECTOR AT TIME OF
FRAME INSPECTION.
BLOWER DOOR TEST IS REOUIRED. MUST SUBMIT BLOWER DOOR TEST REPORT TO GARFIELD
COUNTY COMMUNITY DEVELOPMENT DEPT. OFFICE PRIOR TO SCHEDULING FINAL BUILDING
INSPECTION / C.O. FINAL.
PRESCRIPTIVE PATH USING 2018 IECC Table R402.1.2 HAS BEEN CHOSEN FOR ENERGY COMPLIANCE
OF THIS HOME. MANUAL J REPORT ALSO ATTACHED FOR REFERENCE. ALL NEW HOMES TO HAVE
WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM INSTALLED (2015 IRC TABLE m1507.3.3(1)AND
4)
s)
6))at\
s
N7)
8)
e)
10)
11)
Road & Bridse Drivewav Review/Approvals: {permit @2/-7ilfi
PRIOR TO FINAL BUILDING TNSPECTION & CERTIFICATE OF OCCUPANCY
PROVIDE FINAL APPROVAL/SIGN-OFF FROM GARFIELO COUNTY,S ROAD &
BRTDGE DEPT. CALL (970)625-8601AND HAVE ROAD & BRIDGE SIGN THE
PERMIT INSPECTION CARD.
EET
1 2) MAtN LEVEL FLOOR PLAN A2.2 TNCLUDES 236 SO FT "FUN LOFT" ACCESSED VIA STEEL LADDER
ALONG LIVING ROOM FIREPLACE. LOFT FOR USE AS'NON-HABITABLE STORAGE ONLY'. LOFT MUST
NOT BE USED AS A FUTURE BEDROOM, BUNKROOM OR PLAY AREA (LOFT STORY DOES NOT MEET
2015 rRC SECTTONS R305 CEILING HEIGHT OR R311 MEANS OF EGRESS).