HomeMy WebLinkAboutEngineer's Framing LetterzlL RED HILL+-ENGINEERING + Red Hill Engineeringo LLC Glenwood Springs, CO 81601 Renovation Renai r Instruction RI#:24100401 October 4,2024 Proiect: Garage Attic Renovation 68 Midland Point Rd Carbondale,Co 81623 Attn: Garfield County Building Department 108 8th Street, Suite +01- Glenwood Springs, CO 81601 Client: Daniel Landeros Landeros High Altitude Renovations LLC 1164E 18th St Rifle Co,81650 landeto shighalitude@ gmail. com 970-930-0385 To whom it may concern, Please accept the following repair instruction letter, prepared for Landeros High Altitude Renovations, as certification that the non-compliant joist penetrations for plumbing lines (as shown in the appended photo) will be repaired according to the procedures outlined below. These repairs will restore or exceed the structural integrity of the floor joists compared to their pre- renovated condition. As-Renovated Conditions (see nhoto) During the garage-attic renovation, penetrations were made in the garage ceiling I attic 2x10 floor joists to accommodate plumbing lines. These penetrations were not performed in accordance with applicable code requirements. To remedy this situation, the following repair instructions have been developed to restore the joists to a structurally sufficient state. Renair Instructions (sister 2x6 to existing 2x10's) Sistering Joists o Material: New #2 grade or better 2x6 lumber O The 2x6 sister must extend at least 3 ft beyond either side of the centerline non compliant for a Alignment: The new 2x6 should be aligned flush with the bottom edge of the 2x10 joist. Provide 2x6 sister joist at each location where non-compliant penetrations exist. O o Fastener Installation o 3-inch structural screws or l6d nails shall be used in a staggered pattern, installed from both sides of the sistered joists (exiting 2xl0 & new 2x6) Fastener Spacing: o Fasteners shall be spaced at 12- on center (c-c) along both the top and bottom edges of the 2x6 entering from BOTH the 2x10 side and 2x6 side. o The fasteners on one side shall be staggered 6 inches off-center from the fasteners on the opposite side, ensuring the fasteners from both sides do not align directly through the joist. o Maintain -2" of clear space from the end of the sister joist to the first fastener. o Notching new 2x6 for PVC PiPe o NOTE: Where needed, a maximum 3/o" deep by 2" wide notch may be made on the top side of the 2x6 sister joist to accommodate PVC piping' o No other penetrations are allowed within the new 2x6 sister joists. Water Supply Line Relocation The water supply lines (currently in the area that will be covered with sistered 2x6 joists) must be relocatedAND ensure aminimum of 2" inches clear distance to any other 2x10 joist edge or other existing penetration, following building code specifi cations' Final Inspection All repairs and final conditions should be inspected and approved by the building department. please feel free to contact me for further clarification or if additional information is required. Sincerely, Red Red Hill Engineering Glenwood SPrings, CO 81601 97 0.456.5435 I mike@tedhilIenginee"i'g'com a Date: 1010412024 APPENDIX A: reference as-renovated photo I i ''.il- 4 3 Red Hill Engineenng Glenwood Springs, CO 81601 97 0.456.5435 I mike@redhillengineering.com