Loading...
HomeMy WebLinkAboutRes Check ReportGenerated by RES check'Web Software Compliance Certificate Project Coleman ADU Energy Code: Location: Construction Type: Project Type: Conditioned Floor Area Glazing Area Climate Zone: Permit Date: Permit Number: All Electric ls Renewable Has Charger Has Battery: Has Heat Pump: Construction Site; l0L Monument Ridge Road Parachute, co 81635 2018 lEcc Garfietd CountY, Colorado Single-family New Construction 494 tt2 L7o/o 5 (84e9 HDD) false false false false false Owner/Agent: Kevin and Rhonda Coleman 101 Monument Ridge road Parachute, co 81635 Desig ner/Contractor; Iocld StncKlan Stricklan Homes 3073991925 tstricklan@gmail,com N Compliance: Passes using UA trade-sff Compliance: 1.37o Better Than Code Maximum UA: 15O Your UA: 148 The % Better or worse Than code lndex reflects how close to compliance the house is based on code trade-off rules' It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Slab-on-gracle tradeoffs are no longer-considered in the UA or perfcrmance compliance path in REScheck. Each slab-on-grade asserrrbly: in tlie specifieci cliniate ione rnust meet the niinimum energy code irrsulatiotr R-r,'alue and deptir requirenrents Envelope Assemblies \N Ceiling: Steel Joist/Rafter, 24in. o'c' North: Wood Frame, l-6" o.c. Living Door: Glass Door (over 50% glazing) Bed Door: Glass Door (over 50% glazing) Bathroom Window: VinYl Frame 494 364 56 42 7 0.026 0.060 0.300 0.300 0.300 49.0 27.O 0.0 0.0 0.026 0.051 0.300 0.300 0.300 13 13 t7 13 1 13 16 \7 13 2 Gross Area or Perimeter Cavity R-Value Cont. R-Value Prop. Req. U-Factor U-Factor Prop. UAAssembly Req. UA Door: Glass Door (over 5ooh glazing) Living window: Vinyl Frame East: Wood Frame, l-6" o.c. 27 20 r32 0.300 0.300 0.051 0.300 0.300 0.060 6 6 7 6 6 627.O 0.0 Project Title: Coleman ADU Data filename: Report date: 04122124 Page 1 of 2 Gross Area or Perimeter Cavity R-Value Cont. R-Value Prop. Req. U-Factor U-Factor Prop UA Req UAAssembly bed window 1: Vinyl Frame bed window 2: Vinyl Frame East back: Wood Frame, 16" o.c. South West: Wood Frame, 16" o.c Living window 1: Vinyl Frame Living window 2: Vinyl Frame Living window 3: Vinyl Frame Sout east: Wood Frame, 16" o.c. Floor: Al l-Wood Joist/Truss Crawl Wall: Solid Concrete or Masonry Wall height: 3.5' Depth below grade: 3.0' lnsulation depth: 3.5' 7 7 45 1,42 7 7 r67 494 0.300 0.300 0.051 0.051 0.300 0.300 0.300 0.051 0.047 0.300 0.300 0.060 0.060 0.300 0.300 0.300 0.060 0.033 27.0 27.0 27.0 19.0 19.0 0.0 0.0 0.0 0.0 2 2 3 7 2 2 2 1,0 16 2 2 2 6 2 2 2 9 23 357 0.0 0.055 0.055 l4 l4 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meetthe 2018 IECC requirements in REScheckVersion : REScheck-Web and to comply with the mandatory requirements listed in the REScheck lnspection Checklist. Name - Title Signature Date Project Title: Coleman ADU Data filename: Report date: 04122124 Page 2 of 2