HomeMy WebLinkAboutInstallation Observation Letter 12.25.2024CBO Inc.
129 Cains Lane
Carbondale, CO 81623
970.309.5259
carla.ostberg@gmail.com
December 25, 2024 Project No. C1848
Ashly Ditlow
ashlyditlow@gmail.com
Onsite Wastewater Treatment System (OWTS) Installation Observations
3683 CR 241
Garfield County, Colorado
OWTS Permit SEPT-8473
Ashly,
CBO Inc. observed the installation of the onsite wastewater treatment system (OWTS) on September 17,
2024 for the subject property. Alpine Excavation and Land Clearing installed the system.
The OWTS design is based on 5-bedrooms. An average daily wastewater flow of 600 GPD was used.
The 4-inch SDR-35 sewer line exiting the residence had a double-sweep clean out and a minimum 2%
grade to the septic tank.
The system installation included a 1500-gallon, two-compartment Infiltrator® poly septic tank with an
Orenco® Biotube effluent filter on the outlet tee. This filter must be cleaned annually, or as needed.
Effluent gravity flows to a distribution box, and then to four gravelless chamber trenches. The distribution
box was accessible from grade with flow equalizers installed on each outlet pipe in the distribution box to
assure equal flow to each trench.
Each trench consists of 15 ‘Quick 4’ Standard Plus Infiltrator® chambers for a total of 60 chambers and
720 square feet of infiltrative area. There was at least 4-feet of undisturbed soil between each trench.
Inspection ports were installed at the beginning and end of each trench. Ports may be cut to grade and
placed in sprinkler boxes for access.
The OWTS was generally installed according to specifications. This observation is not a guarantee of
workmanship and/or parts and materials. CBO Inc. should be notified if changes are made to the OWTS
in the future. Any additional OWTS construction must be according to the county regulations.
LIMITS: Observations are limited to components that are visible at the time of the inspection. The installer must
have documented and demonstrated knowledge of the requirements and regulations of the county in
which they are working. The quality of the installation is dependent on the expertise of the installer, soil
type, and weather conditions.
Please call with questions.
Sincerely,
CBO Inc.
Carla Ostberg, MPH, REHS
Distribution box View of septic tank
Encasement pipe to the north of the septic tank / clean out near house
1500 gal tank Encasement pipe (rigid endcaps to be installed)
Looking north toward soil treatment area (STA) / view of septic tank
Additional clean outs on sewer line / tracer wire used on all sewer lines
View of distribution box and STA
All pipes well bedded
Chamber trenches Distribution box
Inlet tee Effluent filter
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs,CO 81601
Phone:970)945 6614 ext.8150
For inspections,call:970 945 6614 ext.8150 and call the Design Engineer,if applicable
Project Address:3683 County Road 241,New Castle,CO 81647 Parcel No.:212306400006
Owner Name:David and Kammy Young Owner Phone:970)471 5672
Designed By:CBO,Inc.Designer Phone:970)309 5259
Number of Bedrooms:5 Minimum Tank Capacity:1,500 gallon Minimum Absorption:700 ft2
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number SEPT 8473_______________________________
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date 01/12/2024____________________Expiration Date_01/12/2025_________________
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the report and design as
submitted by CBO,Inc.dated November 21,2023.Changes to the design and permit must be
approved by Garfield County Public Health and the designer prior to construction.
The new OWTS will serve a new 5 bedroom residence.The new OWTS components will consist of a
new,two compartment 1,500 gallon septic tank set level with access to grade and an effluent filter
installed in the outlet tee of the tank.Effluent will gravity flow to a distribution box set level with
access to grade that will distribute effluent to 720 ft2 of STA.The new STA will consist of four
gravelless chamber trenches consisting of 15 Infiltrator Quick4 chambers per trench 60 chambers
total).Inspection ports will be installed at each end of each trench.Maintain all setbacks and
elevations as designed.
Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final
inspection of the installed system prior to backfill.NO OWTS COMPONENT SHALL BE BACKFILLED
WITHOUT PRIOR APPROVAL FROM GARFIELD COUNTY PUBLIC HEALTH AND THE DESIGNER.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit,the applicant hereby agrees to comply with all
laws and regulations related to the zoning,location,construction,and erection of the proposed
OWTS and associated structures for which this permit is granted.The applicant further agrees
that if the above said regulations are not fully complied with in the zoning,location,erection,
and construction of the above described OWTS and structure,the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability,nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system.Permit issuance will
not constitute a certification that the system,the equipment used in the system,or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act,the regulations adopted thereunder,or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory.Permission is hereby given to the property owner(s)to perform the work indicated
in accordance with the Garfield County OWTS Regulation.This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced.An as built"drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
01/12/2024
Issued By:Garfield County Environmental Health
Department
Date
832‐R‐13‐002