HomeMy WebLinkAboutRes Check Energy ReportGenerated by REScheck-Web Software
Compliance Certificate
Project JULIO MORENO
Energy Code:
Location:
Construction Type:
Project Type:
Project SubType:
Conditioned Floor Area
Glazing Area
Climate Zone:
Permit Date:
Permit Number:
All Electric
ls Renewable
Has Charger
Has Battery:
Has Heat Pump:
201-8 lEcc
Garfield County, Colorado
Single-family
New Construction
None
2,7L7 lt2
L2o/"
5 (8499 HDD)
false
false
false
false
false
Construction Site:
TBD
PARACHUTE, COLORADO 8 1602-
103 1
Ceiling: Cathedral Ceiling
Wall: Wood Frame, 16" o.c.
Door: Solid Door (under 50o/o glazing)
Window: Wood Frame
Wall 1: Wood Frame, 16" o.c.
Window 1: Wood Frame
Wall 2: Wood Frame, 16" o.c.
Owner/Agent:
JULrO MORENO
9703791482
J U LrO@STE EPLECHASECONSTRUCTT
oN.coM
49.0
2r.0
2t.o
Desig ner/Contractor:
brad jordan
jordan architecture inc.
po box 1031
Glenwood Springs, CO 81602-1031
9706186690
BRADJORDANARCH ITECT@GMAIL. C
OM
N
$\
a\\
\
$
Complian.e: 9.17o Better Than Code [laximum UA: 317 \'our UA: 288
The % Better or Worse Than Code lndex reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade
assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements.
Envelope Assem blies
2,717
868
48
80
430
46
960
0.022
0.057
0.166
0.280
0.057
0.280
0.057
0.026
0.060
0.300
0.300
0.060
0.300
0.060
60
42
8
22
22
13
48
7I
44
I4
24
23
I4
50
0.0
0.0
0.0
Compliance: Passes using UA trade-off
Gross Area
or
Perimeter
Cavity
R-Value
Cont,
R-Value
Prop, Req.
U-Factor U-Factor
Prop
UA
Req
UAAssembly
21,.0 0.0
Project Title: JULIO MORENO
Data filename:
Report date: IIl0Il24
Page 1 of10
Cavity
R-Value
Cont.
R-Value
Prop, Req,
U-Factor U-Factor
Gross Area
Perimeter
orAssembly UA UA
Prop. Req.
Door l,: Glass Door (over 50% glazing)
Window 2: Wood Frame
Wall 3: Wood Frame, 16" o.c.
Window 3: Wood Frame
24
98
41,2
68
7
29
2t
20
0.280
0.280
0.057
0.280
0.300
0.300
0.060
0.300
7
27
20
19
0
2t.0 0.0
Floor: Slab-On-Grade (Unheated)
lnsulation depth: 3.0'
lnsulation position: Vertical lnsulation
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application.The proposed building has been designed to meetthe 2018 IECC requirements in
REScheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REScheck lnspection Checklist.
Name - Title Signature Date
231 10.0 0.510 0.540 0
Project Title: JULIO MORENO
Data filename:
Report date: ILl0Il24
Page 2 of10
REScheck Software Version : REScheck-Web
lnspection Checklist
Energy Code: 2018 IECC
Requirements: 0.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
EComplies
EDoes Not
INot Observable
INot Applicable
Additional Comments/Assumptions:
(Tier 3)
Scction
#
& R€o.ilD
,Prc-ln,pectionlPlan Review F'lane Vcrifiied
Va|ue
,Field Verifi,ed
Value Complles?Comments/Aseumptlons
103.1,
103.2
lPR1lls
Construction drawings and
documentation demonstrate
energy code compliance for the
building envelope. Thermal
envelope represented on
construction documents.
mplies
[Does Not
ENot observable
ENot npplicable
103.1.,
L03.2,
403.7
lPR3l1
,s
Construction drawings and
documentation demonstrate
energy code compliance for
lighting and mechanical systems
Systems serving multiple
dwelling units must demonstrate
compliance with the IECC
Commercia I Provisions.,eiil
302.1,
403.7
1eRZl,s
Heating and cooling equipment is
sized per ACCA Manual S based
on loads calculated per ACCA
Manual J or other methods
approved by the code official.
Heating:
Btu/hr_
Cooling:
Btu/hr_
Heating:
Btu/hr_
Cooling:
Btu/hr_
EComplies
EDoes Not
ENot Observable
:ENot Applicable
L lm (Tier 1)2 Medium lmpact (Tier 2)3 Low lm
Project Title: JULIO MORENO
Data filename:
Report date: 1,Il0Ll24
Page 3 of10
S€ction#
& Req.lD
Foundation lnspection Plans Verified
Value
Field Verified
Value Complies?€omments/Assumptions
402.1,.2
lFoLl1
,s
Slab edge insulation R-value R-_
fl Unheated
fl Heated
R-_
n Unheated
n Heated
:EComplies
EDoes Not
,INot Observable
ENot npplicable
See the Envelope Assemblies
table for values.
402.r.2
lFo3l1
@
Slab edge insulation
depth/length.
ft ft IComplies
lDoes Not
flNot Observable
ENot Applicable
See the Envelope Assemblies
table for values.
303.2,1.
lFoLt"12
rs
A protective covering is installed
to protect exposed exterior
insulation and extends a
minimum of 6 in. below grade.
m plies
tr Does Not
ENot Observable
nNot applicable
403,9
IFOt21z
@
Snow- and ice-melting system
controls installed.
mplies
EDoes Not
ENot Observable
ENot Applicable
Additional Comments/Assumptions:
:High lmpact (Tier 1) , 2 lMedium lmpact (Tier 2) 3 ;Low lmpact (Tier 3)
Project Title: JULIO MORENO
Data filename:
Report date: IU0I|24
Page 4 of10
Plans Verified
Value
Field Verified
Value Complies?Comments/Assumptions
Section
#
& Req.lD
Framing / Rough-ln lnspection
402.r.r
402.3.4
lFR1ll
9;
nComplies
lDoes Not
!Not Observable
!Not npplicable
Door U-factor U U See the Envelope Assemblies
table for values.
402.r.r,
402.3.1,,
402.3.3,
402.5
lFR2l1
-tr]
Glazi ng U-factor (area-weighted
average).
U-factors of fenestration products
are determined in accordance
with the NFRC test procedure or
taken from the default table.
U U lies
nDoes Not
nNot Observable
lNot Applicable
Complies
[Does Not
INot observable
nNot Applicable
See the Envelope Assemblies
table for values.
303.1.3
lFR4lr
tl
402.4.t.1
lFR23l1
9.
Air barrier and thermal barrier
i nsta lled per manufacturer's
i nstructions.
Complies
!Does Not
DNot Observable
nNot Applicable
Complies
nDoes Not
nNot observable
lNot Applicable
402.4.3
lFR20l1
,'t)/
Fenestration that is not site built i
is listed and labeled as meeting
'AAMA /WDMA/CSA 101/I,S.2 /A440
or has infiltration rates per NFRC I
;402.4.5
ilFR16l2
403.3.1
lFR12l1
.Ur
400 that do not exceed code
limits.
lC-rated recessed lighting fixtures
sealed at housing/interior finish
and labeled to indicate <2.0 cfm
leakage at 75 Pa.
nComplies
nDoes Not
!Not Qbservable
!Not Applicable
Supply and return ducts in attics
insulated >: R-8 where duct is
>= 3 inches in diameter and >=
R-6 where < 3 inches. Supply and
return ducts in other portions of
the building insulated >= R-6 for
diameter >: 3 inches and R-4.2
for < 3 inches in diameter.
nComplies
nDoes Not
nNot Observable
!Not npplicable
403.3.2
lFR13l1
g.
Ducts, air handlers and filter
boxes are sealed with
plies
EDoes Not
nNot Observable
nNot npplicable
joints/seams com
lnternational Mec
pliant with
hanical Code or
lnternational Residential Code, as
icable.
403.3.5 Building cavities are not used as
lFR1513 ducts or plenums.
!Complies
nDoes Not
ENot Observable
Druot npplicable
.403.4
;IFR17]2
'.q/
403.4.1
I FR24]1
gr
403.5.3
lFR18l2
'*)'t
HVAC piping conveying fluids
above 105 oF or chilled fluids
below 55 oF are insulated to >R-
3.
Protection of insulation on HVAC
piping.
Hot water pipes are insulated to
>R-3.
R-
R-
R-
R-
nComplies
nDoes Not
INot Observable
!Not npplicable
Complies
DDoes Not
!Not Observable
nNot Applicable
nComplies
IDoes Not
!Not observable
!Not npplicable
1:l.lin Low lmpact (Tier 3)hlm (Tier 1)2 Medium lmpact (Tier 2) 3
Project Title: JULIO MORENO
Data filename:
Report date: I1,l0Ll24
Page 5 of10
Section*
& Req.lD
jrr".lng / Rough-ln lnspection Plans Verified
Value
Field Verified
Value Complies?Comments/Assumptlons
403.6
IFRL9l2
Automatic or gravity dampers are
installed on all outdoor air
intakes and exhausts.
lies
Not
nNot Observable
ENot Applicable
Additional Comments/Assumptions:
iLow lmpact (Tier 3)
Project Title: JULIO MORENO
Data filename:
Report date: I7l0Ll24
Page 6 of10
Section
#
& ReqJD
lnsulation lnepection Plans Verified
Value
Field Verified
Va|ue Corrplies?Com ments/Assu,m ptlons
303,1
ltN1312s
All installed insulation is labeled
or the installed R-values
provided.
mplies
lDoes Not
ENot Observable
ENot Applicable
402.r.r
402.2.5
402.2.6
lrN3lls
Wall insulation R-value. lf this is a
mass wall with at least % of the
wall insulation on the wall
exterior, the exterior insulation
requirement applies (FR10).
R-_
! Wood
! Mass
! Steel
R-_
! Wood
! Mass
! Steel
EComplies
[Does Not
ENot Observable
[JNot Applicable
See the Envelope Assemblies
table for values.
303.2
ltN4l1
Wall insulation is installed per
manufacturer's instructions.
plies
lDoes Not
nNot Observable
!Not Applicable
Additional Comments/Assumptions:
1 H Low lmpact (Tier 3)hlm (Tier 1)2 Medium lmpact (Tier 2) , 3
Project Title: JULIO MORENO
Data filename:
Report date: L7l0ll24
Page 7 of10
Field Verified
Value Complies?CommentslAssumptions
Section
#
& Req,lD
Final lnspection Provisions Plans Verified
Value
402.7.1,
402.2.r,
402.2.2,
402.2.6
lFl1l1
Ceiling insulation R-value.
303.1.1.1, Ceiling insulation installed per
303.2 manufacturer's instructions.
IFl2]1 Blown insulation marked every
300 ftr.
R-_
! Wood
! Steel
ACH 50 =
R-_
! Wood
! Steel
mplies
EDoes Not
!Not Observable
nNot npplicable
nComplies
nDoes Not
!Not Observable
!Not npplicable
mplies
lDoes Not
nNot observable
nNot Applicable
mplies
lDoes Not
nNot Observable
nNot Applicable
mplies
lDoes Not
nNot observable
nNot Rpplicable
see the Envelope Assemblies
table for values,
402.2.3
lFt22J2
402.2.4
lFt3ll
402.4.7.2
lFt17l1
Vented attics with air permeable
insulation include baffle adjacent
to soffit and eave vents that
extends over lnsulation.
Attic access hatch and door
insulation >R-value of the
adjacent assembly.
Blower door test @ 50 Pa. <=5
ach in Climate Zones 1-2, and
<=3 ach in Climate Zones 3-8.
R-R-
ACH 50 =
403.3.3
lFt2Tlr
Ducts are pressure tested to
determine air leakage with
either: Rough-in test: Total
leakage measured with a
pressure differential of 0.1 inch
w.g. across the system including
the manufacturer's air handler
enclosure if installed at time of
test. Postconstruction test: Total
leakage measured with a
pressure differential of 0.1 inch
w.g. across the entire system
including the manufacturer's air
handler enclosure.
cfm/100 cfm/100 Icomplies
nDoes Not
nNot observable
nNot {pplicable
fF-ft2
403.3.4
lFt4l1
Duct tightness test result of <=4
cfm/100 ft2 across the system or
<=3 cfm/100 ft2 without air
handler @ 25 Pa. For rough-in
tests, verification may need to
occur durinq Framing lnspection.
cfm/100 cfm/100 lies
EDoes Not
nNot Observable
DNot Applicable
ft2 ft2
.403.3.2.1.
:lFl241r
Air handler leakage designated
by manufacturer at <=2%:o of
design air flow.
flComplies
flDoes Not
DNot Observable
flNot Applicable
40 3.1.1
lFr9l2
Programmable thermostats
installed for control of primary
heating and cooling systems and
initially set by manufacturer to
code specifications.
nComplies
nDoes Not
!Not Observable
nttot applicable
',403.7.2
:IFl1O]:
Heat pump thermostat installed
on heat pumps.
!Complies
nDoes Not
nNot Observable
nNot Applicable
403.5.1
r IFt11]2
Circulating service hot water
systems have automatic or
accessible manual controls.
nComplies
!Does Not
nNot Observable
!Not Applicable
1 High lmpact (Tier 1) 2 , Medium lmpact 3 Low lmpact (Tier 3)(Tier 2)
Project Title: JULIO MORENO
Data filename:
Report date: ILl0Il24
Page 8 of10
Sectaon
#
& Req.lD
Final lnspection Provisions Plans Verified
Value
Field Verified
Value Complies?Comments/Assumptions
403.6.1
IF125]2
403.2
lFt26l2
403.5.1.1
IFt28]2
All mechanical ventilation system
fans not part oftested and listed
HVAC equipment meet efficacy
and air flow limits per Table
R403.6.1.
Hot water boilers supplying heat
through one- or two-pipe heating
systems have outdoor setback
control to lower boiler water
temperature based on outdoor
temperatu re.
Heated water circulation systems
have a circulation pump. The
system return pipe is a dedicated
return pipe or a cold water supply
pipe. Gravity and thermos-
syphon circulation systems are
not present. Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
occupancy. Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
Complies
lDoes Not
INot Observable
nNot Applicable
EComplies
EDoes Not
ENot Observable
nruot npplicable
Complies
IDoes Not
nNot observable
flNot Applicable
.5.I.2 Electric heat trace systems912 comply with IEEE 515.1 or UL
515. Controls automatically
adjust the energy input to the
heat tracing to maintain the
desired water temierature in the
piping.
nComplies
IDoes Not
!Not Observable
nNot Applicable
!Complies
lDoes Not
nNot Observable
!Not Applicable
nComplies
nDoes Not
DNot Observable
[ruot npplicable
403.5.2
lFr3ol2
403.5.4
lFt31l2
Demand recirculation water
systems have controls that
manage operation of the pump
and limit the temperature of the
water entering the cold water
piping to <= 104eF.
Drain water heat recovery units
tested in accordance with CSA
855.1. Potable water-side
pressure loss of drain water heat
recovery units < 3 psi for
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units < 2 psi for
individual units connected to
three or more showers,
404.7
lFt6l1
90Yo or more of permanent
fixtures have high efficacy lamps
flComplies
EDoes Not
!Not Observable
nNot Applicable
404.Lr
lFt23l3
r,,
Fuel gas lighting systems have
no continuous pilot light.
!Complies
nDoes Not
INot Observable
flNot Applicable
mplies401.3 Compliancecertificateposted
, lFlT J2 lDoes Not
!Not Observable
nNot Applicable
1 tHigh lmpact (Tier 1) 2 Medium lmpact (Tier 2) 3 Low lmpact (Tier 3)
Project Title: JULIO MORENO
Data filename:
Report date: 7Il0Il24
Page 9 of10
Section
#
& Req"lD
Final lnspection Provisions Plans Verlfied
Value
Field Verifled
Value Complies?Comments/Arsumptions
303.3
lFr18l3
Manufacturer manuals for
mechanical and water heating
systems have been provided.
Complies
EDoes Not
ENot Observable
ENot Applicable
Additional Comments/Assumptions:
1 iHigh lmpact (Tier 1) ' 2 rMedium lmpact (Tier 2) i 3 Low lmpact (Tier 3)
Project Title: JULIO MORENO
Data filename:
Report date: IIl01l24
Page 1-0 of 10
fr 2018 IECG Energy
Effi ciency Certificate
Above-Grade Wall
Below-Grade Wall
Floor
Ceiling / Roof
Ductwork (unconditioned spaces):
Window
Door
Heating System
Cooling System:_
Water Heater:
Name:
Comments
21.OO
o.oo
10.00
49.00
o.28
o.L7
Date:
lnsulation Rating R-Value
Glass & Door Rating U-Factor SHGC
Heating & Cooling Equipment Eff iciency