HomeMy WebLinkAboutConditions of Permitc ONDITIONS OF PERMIT
BLRE-02-25-9069
CASTLE CREEK VALLEY RANCH
New Single-family dwelling
117 49 CR 31 1 , Silt
Sec 36, Twns 07 , R92 - 2401 36200056
1) ALL WORK SHALL COMpLy W|TH THE 2015 INTERNATIONAL RESIDENTIAL CODE (l.R.C.)AND 2018
INTERNATIONAL ENERGY CONSERVATION CODE (I.E.C.C.)
2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE
ATTACHED "GARFIELD COUNTY BUILDING REOUIREMENTS". NUMBER REFERENCES NOTED ON
PLANS REFER TO SPECIFIC ITEMS ON THIS LIST.
3) ELECTRTCAL pERMtTTtNG AND TNSPECTTONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL
ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS
REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY.
4) ALL EXTERIOR LIGHTING TO BE DOWNCAST AND SHIELDED.
s) WILDFIRE MlTlcATloN RECOMMENDATIoNS: SHoULD CoMPLY WITH WILDFIRE MITIGAT,?) 1Y?_ ql
DEFENSIBLE SPACE RECOMMENDATIONS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE .{
DISTRICT. PLEASE REFER TO THE GARFIELD COUNTY COMMUNIry DEVELOPMENT WEBSITE FOR I i
6) 3?Sltt"JrttJil?Hill?]a *ror,*ED Ar FootNG rNSpECtoN AND pRroR ro ANy ..NCRETE l{
POUR. PROVIDE COPY OF GEOTECHNICAL ENGINEERS REPORT TO THE BUILDING INSPECTOR.
1,500 PSF soil bearing.
7) PRE-ENGINEERED ROOF TRUSSES. HAVE ENGINEERING FOR BUILDING INSPECTOR AT TIME OF
FRAME INSPECTION.
8) SEPTIC SYSTEM REVIEW / APPROVALS: PRIOR TO BUILDING INSPECTION & CERTIFICATE OF
OCCUPANCY PROVIDE FINAL APPROVAUSIGN-OFF FROM GARFIELD COUNTY'S PUBLIC HEALTH
DEPT.
9) PROPANE FUEL TYPE LISTED - SEE ATTACHED PROPANE GUIDE.
70) CAUTION: NO ARCHITECTURAL FLOOR PLANS NOR STRUCTURAL FRAMING DETAIL lS PROVIDED
FOR THE APPARENT ATTIC ACCESSED BY LADDER ON MAIN LEVEL FLOOR PLAN A1.02. ATTIC
SPACE IS NOTAPPROVED FOR FUTURE HABITABLE LIVING. /FATTIC IS INTENDED FOR USEAS NON-
HABITABLE STORAGE - OWNER BUILDER OR CONTRACTOR MUST PROVIDE DEFERRED FRAMING
DETAILS DEMONSTRATING ATTIC STRUCTURE COMPLIES WITH 2015 IRCTABLE R301.5 MINIMUM
DISTRIBUTED LIVE LOADS.
1 1) MA|N LEVEL PLAN A1.02 MECHANICAL CLOSET 108 OFF BEDROOM SHALL COMPLY W\TH 2015 tRC
sEcrio^/ G2406 (SEE STAMP). FTELD VERIFY AS-BUiLTCONDII/ONS.
1 2) BLOWER DOOR TEST lS REOU|RED. r\4UST SUBMTT BLOWER DOOR TEST REPORT TO GARFIELD
COUNTY COMMUNIry DEVELOPMENT DEPT. OFFICE PRIOR TO SCHEDULING FINAL BUILDING
INSPECTION / C.O. FINAL.
13) PRESCR|pTtVE PATH USING 2018 tECC TABLE R402.1.2 rS CHOSEN FOR ENERGY COMPLIANCE OF
THIS HOME. MANUAL S REPORT ATTACHED FOR REFERENCE. ALL NEW HOMES TO HAVE WHOLE-
HOUSE MECHANICAL VENTILATION SYSTEM INSTALLED (2015 IRC TABLE m1507.3.3(1)AND (2)
SHOWN ON COVER SHEET.
t
a\
.\
\
\