HomeMy WebLinkAbout Blower Door Test ReportJ B V� 9, �1{if SrLil� • CO O L-V Date of Test: 3/27/2025 Customer: RAM Development, Inc. 12370 Highway 82 Carbondale, CO 81623 Phone: 970-987-1569 Email: bobby@ramdev.build Website: ramdev.build Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve 4. Test Settings: 5. Accuracy Level Infiltration Estimates BUILDING LEAKAGE TEST Frostbusters & Coolth Co. PO Box 94 Basalt, CO 81621 Email: fritzd@frostbusters.com Website: frostbusters.com Test File: 12730 Hwy 82 - Blower Door Test 3-27-2025 Technician: Fritz Diether Project Number: Final Blower Door Test Building Address: Almazan ADU/Garage 12370 Highway 82 Carbondale, CO 81623 1001 CFM50 (+/- 0.6 %) 3.44 ACH50 55.1 in2 LBL E12* @ 4 Pa Flow Coefficient ( ) = 96.3 ( +/- 3.4 %) Exponent (n) = 0.5 8 ( +/- 0.010 ) Correlation Coefficie t = 0.99981 Test Standard: RESN T Multi -Point Test Test Mode: Depressuri ti- Standard Level of Accurac Test 1. Estimated Average Annual Infiltration Rate: 56.7 CFM 0.19 ACH 18.9 CFM 2. Estimated Design Infiltration Rate: Winter: 105.6 CFM 0.36 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Mechanical Ventilation Guideline (based on ASHRAE 62.2-2010) Recommended Whole Bldg Rate: Base Rate: 37.4 CFM 37.4 CFM From the 2021 IECC: Exception: When testing individual dwelling units, an air leakage rate not exceeding 0.30 cubic feet per minute per square foot [0.008 m3/(s x m2)] of the dwelling unit enclosure area, tested in accordance with ANSI/RESNET/ICC 380, ASTM E779 or ASTM E1827 and reported at a pressure of 0.2 inch w.g. (50 Pa), shall be permitted in all climate zones for: 1. Attached single and multiple- family building dwelling units. 2. Buildings or dwelling units that are 1,500 square feet (139.4 m2) or smaller. Results: 1,001 CFM/ 5,394 Sq Ft Surface Area = .19 CFM/Sq Ft. I I Building Passes. From the 2018 IECC: R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding (3.00 ACH50) three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in accordance with RESNET/ICC 380, ASTM E779 or ASTM E1827 and reported at a pressure of 0.2 inch w.g. (50 Pascals). Where required by the code official, testing shall be conducted by an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Building is at 3.44 ACH50. BUILDING LEAKAGE TEST Page 2 of 4 COOLSH Date of Test: 3/27/2025 Test File: 12730 Hwy 82 - Blower Door Test 3-27-2025 Building Information Volume 17477 Surface Area 5394 Floor Area 1489 Height 24 # of Bedrooms 2 # of Occupants 3 Year of Construction 2025 Wind Shield E Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Location Climate Information Ventilation Weather Factor 0.80 Energy Climate Factor 19.00 Heating Degree Days 9000 Cooling Degree Days 28 Design Winter Wind Speed 1.6 mph Design Summer Wind Speed 10.9 mph Design Winter Temp Diff 77 deg F Design Summer Temp Diff 11 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 p9S S UST 44��v �V o. BUILDING LEAKAGE TEST Page 3 of 4 cool Date of Test: 3/27/2025 Test File: 12730 Hwy 82 - Blower Door Test 3-27-2025 Depressurization Test: Environmental Data Indoor Temperature (OF) Outdoor Temperature (OF) Altitude (ft) 74.0 51.0 6155.0 Data Points - Data Entered Manually Nominal Baseline Adjusted Fan Building Pressure Building Pressure Pressure (Pa) (Pa) (Pa) -0.5 n/a n/a -60.0 -59.3 38.0 -55.0 -54.3 34.0 -50.0 -49.3 30.0 -45.0 -44.3 26.0 -40.0 -39.3 219.0 -35.0 -34.3 185.0 -30.0 -29.3 155.0 -25.0 -24.3 124.0 -20.0 -19.3 91.0 -15.0 -14.3 64.0 -0.9 n/a n/a Time Averaging Period: 10 None Nominal Adjusted Flow Flow Fan (cfm) (cfm) % Error Configuration 1120 1111 0.2 Ring A 1061 1052 0.0 Ring A 998 990 -0.3 Ring A 931 923 -0.9 Ring A 876 869 0.3 Ring B 806 799 0.0 Ring B 738 732 0.7 Ring B 661 656 0.8 Ring B 567 562 -0.7 Ring B 476 472 -0.2 Ring B Deviations from Standard RESNET Multi -Point Test - Test Parameters BUILDING LEAKAGE TEST Page 4 of 4 COOL-O Date of Test: 3/27/2025 Test File: 12730 Hwy 82 - Blower Door Test 3-27-2025 Comments None