HomeMy WebLinkAboutConditions of PermitcoNDlflo NS OF PERMIT BLCO-04-25-9210 COLORADO ROCKY MOUNTAIN SCHOOL FACU LTY APARTM ENT ADDITION 1493 County Road 1 06 Carbondale, CO 81623 1) THE APPROVED PLANS ARE TO BE ON-SlrE FOR INSPECTIONS. 2) SANITARY FACILITIES ARE REOUIRED TO BE PROVIDED FOR WORKERS. 3) A LIST OF REOUIRED INSPECTIONS WILL BE ATTACHED TO THE PLANS. THE STATE IS TO PERMIT AND APPROVE THE ELECTRICAL WORK. RMITS 4) UNDERGROUND UTtLtry LOCATES rS THE RESPONSIBILIry OF THE OWNER OR CONTRACTOR. 811 IS THE COLORADO UTILIry LOCATE HOT LINE. 5) PLEASE CONTACT THE TOWN OF CARBONDALE FOR THE WATER AND SEWER CONNECTIONS AND TAP FEES. 6) ALL BACKFLOW PREVENTERS ARE REOUIRED TO BE TESTED AND CERTIFIED BY A LICENSED BACKFLOW SPECIALIST AFTER INSTALLATION AND PRIOR TO ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. 7) ELECTRICAL CODE COMPLIANCE WILL BE DETERMINED BASED ON FIELD INSPECTIONS PERFORMED BY THE STATE ELECTRICAL INSPECTOR, (303) 869-3458. PLEASE HAVE THE INSPECTOR SIGN THE BUILDING CARD OR PROVIDE WRITTEN DOCUMENTATION OF THE INSPECTIONS. 8) THE ELECTRICAL CODE REOUIRES A SEPARATE ELECTRICAL PERMIT FOR LOW VOLTAGE FIRE ALARMS THAT HAS AN ALARM PANEL AND SEND A NOTIFICATION TO THE FIRE DISTRICT WHEN UNDER ALARM. A ROUGH-IN INSPECTION WITH THE STATE ELECTRICAL INSPECTOR IS REOUIRED (303) 869-3458. PLEASE HAVE THE INSPECTOR SIGN THE BUILDING CARD OR PROVIDE WRITTEN DOCUMENTATION OF THE INSPECTION. 9) THE FIRE SPRINKLER AND ALARM ARE REOUIRED TO BE INSPECTED AND APPROVED BY THE LOCAL FIRE PROTECTION DISTRICT. PLEASE PROVIDE SHOP DRAWINGS TO THE FIRE DISTRICT FOR REVIEW AND SCHEDULE THE INSPECTIONS ACCORDINGLY. PLEASE HAVE THE FIRE MARSHAL SIGN THE INSPECTION CARD WHEN THE ROUGH INSPECTION IS APPROVED AND WHEN THE FINAL INSPECTION IS APPROVED. More conditions - 2"d page 10)GEOTECHNTCAL OBSERVATTON tS REOUTRED WHEN THE EXCAVATTON tS COMPLETE AND WRITTEN VERIFICATION BE SUPPLIED AT FOOTING INSPECTION, 1 500 PSF. 11)ALL EXTERIOR LIGHTING IS TO BE DOWNCAST AND SHIELDED. 12)SAFETY GLAZING IS NOT DESIGNATED ON THE PLANS. SAFEW GLAZING WILL BE CHECKED DURING THE FRAMING AND FINAL INSPECTION. (IBC 2406.4) 13)ANY MEMBRANE AND THROUGH PENETRATIONS OF THE FIRE RESISTIVE CONSTRUCTION WILL BE REQUIRED TO BE FIRE-STOPPED WITH LISTED FIRE STOPPING ASSEMBLIES. THE CONTRACTOR IS TO PROVIDE A CUT SHEET FOR THE ASSEMBLTES AT THE FRAMTNG tNSPECT|ON. (tBC 713) 14) IF THE FIRE SPRINKLER SYSTEM REQUIRES A FIRE PUMP. THEN THE UTILIry ROOM TI IAT I IOUSTS TI IT PUMP WILL BE REOUIRED TO BE ONE-HOUR CONSTRUCTION. (rBC TABLE s08.2.s) 15)A PASSING BLOWER DOOR TEST IS REQUIRED TO BE SUBMITTED PRIOR TO ISSLIING THE CERTIFICATE OF OCCUPANCY. 16)ANY EXPOSED FOAM tS TO BE COVERED W|TH AN tGNtTtON BARRTER OR A THERMAL BARRTER BASED ON LOCAT|ON. (tRC R316) 17)THE APARTMENT IS TO BE SUPPLIED WITH MECHANICAL VENTILATION OF OUTDOOR AIR. THE MINIMUM VENTILATION RATE IS TO BE CFM = (O.O1X TOTAL SOUARE FOOTAGE OF THE HOUSE) + 7.5 X (NUMBER OF BEDROOMS +1) GENERAL NOTES ON THE PLANS INDICATE WHOLE HOUSE VENTILATION. 18)MINIMULLY THE ICE SHIELD IS TO BE INSTALLED AT THE EAVES TO A MINIMUM 24" UP FROM THE INSULATED VI/ALLS. 19)ENGINEER STAMPED TRUSS DRAWINGS ARE REOUIRED TO BE PROVIDED TO THE INSPECTOR AT FRAMING INSPECTION. 20)ALL SHOWER DOORS ARE REOUIRED TO MAINTAIN 22'' IN THE CLEAR AND ARE REQUIRED TO SWING OUT. 21)IF PART OF THE THERMAL ENVELOPE, ATTIC ACCESSES ARE REOUIRED TO BE WEATHER STRIPPED AND INSULATION IS TO BE PERMANENTLY ATTACHED TO THE ACCESS. THE R.VALUE FOR THE ACCESS IS THE SAME AS THE ATTIC. 22)IF THE SLAB ON GRADE IS HEATED, A MINIMUM OF R-5 INSULATION IS REOUIRED UNDER THE SLAB. 23)KITCHEN HOODS OVER 4OO CFM REQUIRE MAKE-UP AIR. THE STOVE/OVEN MANUFACTURER SPECIFIES THE CFM REQUIRED.