HomeMy WebLinkAboutConditions of PermitcoNDlflo NS OF PERMIT
BLCO-04-25-9210
COLORADO ROCKY MOUNTAIN SCHOOL
FACU LTY APARTM ENT ADDITION
1493 County Road 1 06
Carbondale, CO 81623
1) THE APPROVED PLANS ARE TO BE ON-SlrE FOR INSPECTIONS.
2) SANITARY FACILITIES ARE REOUIRED TO BE PROVIDED FOR WORKERS.
3) A LIST OF REOUIRED INSPECTIONS WILL BE ATTACHED TO THE PLANS. THE STATE
IS TO PERMIT AND APPROVE THE ELECTRICAL WORK.
RMITS
4) UNDERGROUND UTtLtry LOCATES rS THE RESPONSIBILIry OF THE OWNER OR
CONTRACTOR. 811 IS THE COLORADO UTILIry LOCATE HOT LINE.
5) PLEASE CONTACT THE TOWN OF CARBONDALE FOR THE WATER AND SEWER
CONNECTIONS AND TAP FEES.
6) ALL BACKFLOW PREVENTERS ARE REOUIRED TO BE TESTED AND CERTIFIED BY A
LICENSED BACKFLOW SPECIALIST AFTER INSTALLATION AND PRIOR TO ISSUANCE
OF THE CERTIFICATE OF OCCUPANCY.
7) ELECTRICAL CODE COMPLIANCE WILL BE DETERMINED BASED ON FIELD
INSPECTIONS PERFORMED BY THE STATE ELECTRICAL INSPECTOR, (303) 869-3458.
PLEASE HAVE THE INSPECTOR SIGN THE BUILDING CARD OR PROVIDE WRITTEN
DOCUMENTATION OF THE INSPECTIONS.
8) THE ELECTRICAL CODE REOUIRES A SEPARATE ELECTRICAL PERMIT FOR LOW
VOLTAGE FIRE ALARMS THAT HAS AN ALARM PANEL AND SEND A NOTIFICATION
TO THE FIRE DISTRICT WHEN UNDER ALARM. A ROUGH-IN INSPECTION WITH THE
STATE ELECTRICAL INSPECTOR IS REOUIRED (303) 869-3458. PLEASE HAVE THE
INSPECTOR SIGN THE BUILDING CARD OR PROVIDE WRITTEN DOCUMENTATION
OF THE INSPECTION.
9) THE FIRE SPRINKLER AND ALARM ARE REOUIRED TO BE INSPECTED AND
APPROVED BY THE LOCAL FIRE PROTECTION DISTRICT. PLEASE PROVIDE SHOP
DRAWINGS TO THE FIRE DISTRICT FOR REVIEW AND SCHEDULE THE INSPECTIONS
ACCORDINGLY. PLEASE HAVE THE FIRE MARSHAL SIGN THE INSPECTION CARD
WHEN THE ROUGH INSPECTION IS APPROVED AND WHEN THE FINAL INSPECTION
IS APPROVED.
More conditions - 2"d page
10)GEOTECHNTCAL OBSERVATTON tS REOUTRED WHEN THE EXCAVATTON tS
COMPLETE AND WRITTEN VERIFICATION BE SUPPLIED AT FOOTING INSPECTION,
1 500 PSF.
11)ALL EXTERIOR LIGHTING IS TO BE DOWNCAST AND SHIELDED.
12)SAFETY GLAZING IS NOT DESIGNATED ON THE PLANS. SAFEW GLAZING WILL BE
CHECKED DURING THE FRAMING AND FINAL INSPECTION. (IBC 2406.4)
13)ANY MEMBRANE AND THROUGH PENETRATIONS OF THE FIRE RESISTIVE
CONSTRUCTION WILL BE REQUIRED TO BE FIRE-STOPPED WITH LISTED FIRE
STOPPING ASSEMBLIES. THE CONTRACTOR IS TO PROVIDE A CUT SHEET FOR THE
ASSEMBLTES AT THE FRAMTNG tNSPECT|ON. (tBC 713)
14) IF THE FIRE SPRINKLER SYSTEM REQUIRES A FIRE PUMP. THEN THE UTILIry ROOM
TI IAT I IOUSTS TI IT PUMP WILL BE REOUIRED TO BE ONE-HOUR CONSTRUCTION.
(rBC TABLE s08.2.s)
15)A PASSING BLOWER DOOR TEST IS REQUIRED TO BE SUBMITTED PRIOR TO
ISSLIING THE CERTIFICATE OF OCCUPANCY.
16)ANY EXPOSED FOAM tS TO BE COVERED W|TH AN tGNtTtON BARRTER OR A
THERMAL BARRTER BASED ON LOCAT|ON. (tRC R316)
17)THE APARTMENT IS TO BE SUPPLIED WITH MECHANICAL VENTILATION OF
OUTDOOR AIR. THE MINIMUM VENTILATION RATE IS TO BE CFM = (O.O1X TOTAL
SOUARE FOOTAGE OF THE HOUSE) + 7.5 X (NUMBER OF BEDROOMS +1)
GENERAL NOTES ON THE PLANS INDICATE WHOLE HOUSE VENTILATION.
18)MINIMULLY THE ICE SHIELD IS TO BE INSTALLED AT THE EAVES TO A MINIMUM 24"
UP FROM THE INSULATED VI/ALLS.
19)ENGINEER STAMPED TRUSS DRAWINGS ARE REOUIRED TO BE PROVIDED TO THE
INSPECTOR AT FRAMING INSPECTION.
20)ALL SHOWER DOORS ARE REOUIRED TO MAINTAIN 22'' IN THE CLEAR AND ARE
REQUIRED TO SWING OUT.
21)IF PART OF THE THERMAL ENVELOPE, ATTIC ACCESSES ARE REOUIRED TO BE
WEATHER STRIPPED AND INSULATION IS TO BE PERMANENTLY ATTACHED TO THE
ACCESS. THE R.VALUE FOR THE ACCESS IS THE SAME AS THE ATTIC.
22)IF THE SLAB ON GRADE IS HEATED, A MINIMUM OF R-5 INSULATION IS REOUIRED
UNDER THE SLAB.
23)KITCHEN HOODS OVER 4OO CFM REQUIRE MAKE-UP AIR. THE STOVE/OVEN
MANUFACTURER SPECIFIES THE CFM REQUIRED.