HomeMy WebLinkAboutConditions of PermitCONDITION OF PERMIT
BLRE-0 6-25-9291
DEAN KARSTENSEN
New Single-family dwelling w/ attached garage
1 13 Shore Dr, Silt
Riverview Ranch Subdivision, Lot 1 - 217912301001
1) ALL WORK SHALL COMply W|TH THE 2015 TNTERNATTONAL RESTDENTTAL CODE (r.R.C.)AND 2018
I NTERNATIONAL EN ERGY CONSERVATION CODE ( I. E.C.C.)
2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE
ATTACHED "GARFIELD COUNTY BUILDING REOUIREMENTS". NUMBER REFERENCES NOTED ON
PLANS REFER TO SPECIFIC ITEMS ON THIS LIST.
3) ELECTRTCAL PERM|TTING AND TNSPECTTONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL
ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION, ELECTRICAL FINAL APPROVAL IS
REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY.
4) ALL EXTERTOR LIGHTING TO BE DOWNCASTAND SHIELDED.
5) WILDFIRE MITIGATION RECOMMENDATIONS: SHOULD COMPLY WITH WILDFIRE MITIGATION AND
DEFENSIBLE SPACE RECOMMENDATIONS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE
DISTRICT. PLEASE REFER TO THE GARFIELD COUNTY COMMUNITY DEVELOPMENT WEBSITE FOR
ADDITIONAL I NFORMATION.
6) OPEN HOLE SOTLS REPORT rS REOUTRED AT FOOTTNG TNSPECTTON AND PRIOR TO ANY CONCRETE
POUR. PROVIDE COPY OF GEOTECHNICAL ENGINEERS REPORT TO THE BUILDING INSPECTOR.
1,500 PSF soil bearing.
7) PRE-ENGTNEERED ROOF TRUSSES. HAVE ENGTNEERING FOR BUILDING INSPECTOR AT TIME OF
FRAME INSPECTION.
8) A LOT TMPROVEMENT CERT|F|CATE, SEALED BY A COLORADO LICENSED SURVEYOR, lS REOUIRED AT
FOUNDATION INSPECTION TO VERIFY STRUCTURE IS IN COMPLIANCE WITH MINIMUM SETBACK
REOUIREMENTS / BUILDING ENVELOPE.
9) SEPTIC SYSTEM REVIEW / APPROVALS: PRIOR TO BUILDING INSPECTION & CERTIFICATE OF
OCCUPANCY PROVIDE FINAL APPROVAYSIGN-OFF FROM GARFIELD COUNTY'S PUBLIC HEALTH
DEPT.
10) TWO "UNFtNtSHED MECHANTCAL" SPACES ON BASEMENT 41 ARE NOT APPROVED FOR USE AS
HABITABLE LIVING SPACE(S). SEPARATE BUILDING PERMIT IS REOUIRED FOR FUTURE CHANGE IN
USE OR OCCUPANCY OF SAID SPACES. FLOOR PLANS GRAPHICALLY SHOW THE SPACE FOR
MECHANICAL USE ONLY.
1 1 ) BLOWER DOOR TEST tS REOUTRED. MUST SUBMIT BLOWER DOOR TEST REPORT TO GARFIELD
COUNTY COMMUNIry DEVELOPMENT DEPT. OFFICE PRIOR TO SCHEDULING FINAL BUILDING
INSPECTION / C.O. FINAL.
12) PRESCRIPTiVE PATH USING ATTACHED RESCHECK REPORT HAS BEEN CHOSEN FOR ENERGY
COMPLIANCE OF THIS HOME DESIGN. MANUAL J REPORT ALSO ATTACHED FOR REFERENCE.
ALL NEW HOMES TO HAVE WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM INSTALLED (2015
IRC TABLE m1507.3.3(1) AND (2) SHOWN ON COVER SHEET.
\
$
\'\