Project Address: 3257 CR 237, Silt, CO 81652 Parcel No.: _212724200392
Owner Name: James and Kelly Lord Owner Phone: (970) 948-2934
Designed By: Bell Consulting Designer Phone: (970) 948-3153
Number of Bedrooms: _2_ Minimum Tank Capacity: 1,000-gallon Minimum Absorption: 375 ft2
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number _SEPT-9099_______________________________
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date _08/06/2025____________________ Expiration Date_08/06/2026_________________
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the report and design as submitted by
Bell Consulting dated August 5, 2025. Changes to the design and permit must be approved by Garfield
County Public Health and the designer prior to construction.
The new OWTS will serve a two-bedroom residence. The system will consist of a new, two-compartment
1,060-gallon septic tank set level with access at grade and an effluent filter in the outlet tee of the tank
followed by a 500-gallon single-compartment pump chamber set level with access at grade with a
screened high-head pump in the pump chamber. Effluent will be pumped via 2” diameter Schedule 40
PVC pump line to an Automatic Distributing Valve (ADV), set level with access at grade, to distribute
effluent to 378 ft2 of STA. The new STA will consist of three gravelless chamber trenches, each trench
measuring three feet wide by 42 feet long and consisting of a minimum of 3 feet of secondary sand
material. Distribution laterals are to be 1 ½ inch Schedule 40 PVC, with 1/8-inch orifices 4-feet on center
and the laterals ending in 90-degree sweeping bends and flushing valves at the distal end of the laterals.
Laterals are to be placed in GeoMat placed directly on the sand in the trenches. The orifices are to be
facing downward. Inspection ports shall be installed at the distal end of each trench (minimum). The
residual head (squirt height) at the end of the system is to be 5-feet. Maintain all setbacks and elevations
as designed.
To assist in scheduling, please contact Garfield County Public Health (970-945-6614 ext. 8150) to notify
the start of OWTS construction. Contact the designer and Garfield County Public Health at least 48 hours
prior to requesting final inspection of the installed system prior to backfill. NO OWTS COMPONENT SHALL
BE BACKFILLED WITHOUT PRIOR APPROVAL FROM GARFIELD COUNTY PUBLIC HEALTH AND THE
DESIGNER.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction, and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection,
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as-built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
08/06/2025
Issued By: Garfield County Environmental Health
Department
Date