HomeMy WebLinkAboutManual J Report/huzaal f Design Report /WtaeeRadiantWorks Professional Project lnformation Project Number Project Name Weathers Residence 11"".,-Contact lnformation ' i- j$esigned By Brent Hettinger JllN t r, company Name George T. sanders company'' u ,l'6|.' r"Number g7o-468-82s4 ,, Designed For Project Assumptions Outdoor Temp -19 "F Elevation 6100 ft Wind Speed 10 mph Market Cat. Carbondale, CO Zone 1 Design Application: Product: # of Circuits: Circuit Length: Manifold Distance Heated Area: Radiant Heating 1/2" RadiantPEX+ 4 225 tt 20ft 713 ft2 Supply Fluid Temp Delta T: Flow: Head: Radiant Capacity: Required Heat: Panel Load: % Glycol: 110'F 20'F 2,47 GPM 4.3 ft 28600 BTUih 18647 BTUih 22463BTUth 30o/" Construction - Slab Slab Thickness: Slab Conductivity 4in o.B1 BTU(h'ft..F) Thickness Above Tube: 2 in Garage (Zone 1) Floor Coverings Quantity Area R-Value lnfiltration Total Heat Loss Nt\ $' N N Quantity Area R-Value lnfiftration Total Heat LossWalls No Floor Covering R-0 Wall 1 3973 BTU/h11020It2 R-21 Windows Quantity Area R-Value lnfiltration Total Heat Loss Window 1 1 24ft2 R-3.14 0.02 649 BTU/h Doors Quantity Area R-Value lnfiltration Total Heat Loss Door 1 1 238 tt2 R-2 0.095 11207 Bluth Ceilings Quantity Area R-Value lnfiltralion Total Heat Loss Ceiling 1 I 712.89 fi2 R-49 0 1259 BTU/h ** Heating load calculations used in Radiantwo*s are based on the ASHBAE 2009 Fundamentals Manual** ** Snow melting calculations used in Radiantwo*s are based on the ASHRAE 2007 HVAC Applications Manual ** Weathers Residence.rad Copyright(c) Watts Radiant 2018 Page 1 of 28 RadiantWorks Professional Design Report 612012025 Skylights Quantity Arca R-Valuc lnfiltration Total Heat Loss No Skylights 0 0ft2 R-0 0 in2 Garage Heat Loss Summary 65.60/o 7.4o/o O.Oo/o I No Floor Govering I Walll I Window 1 E Door 1 lE Ceiling 1 I No Skylights 23.2o/o 3.8o/o Zone Notes: ** Heating load calculations used in nadiantworks ate based on the ASHRAE 2009 Fundamentals Manual**** Snow meltlng cdlculations used in Radiantworks are based on the ASHRAE 2007 HVAC Appllcatlons Manual ** WeatherS Residence.rad Copyright(c) Watts Radiant 2018 Page 2 of 28 RadiantWorks Professional Design Report 6120t2025 Zone 2 Design Application: Product: # of Circuits: Circuit Length: Manifold Distance: Heated Area: Radiant Heating 1/2" RadiantPEX+ 2 190 ft 20ft 177 ft2 Supply Fluid Temp: Delta T: Flow: Head: Radiant Capacity: Required Heat: Panel Load: o/o Glycol: 110"F 20'F 0.4 GPM 0.4 ft 8689 BTU/h 3099 BTU/h 3631 BTUih 30o/o Construction - ThinSlab ThinSlab Thickness: ThinSlab Conductivity: 2in 2 BTU(h.ft."F) Subfloor Thickness: Subfloor Conductivity: 0.75 in 0.085 BTU(h'ft."F) Mud,Lndry (Zone 2) Floor Coverings Quantity Area R-Value lnfiltration Total Heat Loss Tile : R-0.11 R-0.11 Walls Quantity Area R-Value lnfiltration Total Heat Loss Wall 1 1 144 tr2 R-21 0 875 BTU/h Windows Quantity Area R-Value lnfiltration Total Heat Loss Window 1 1 10 ft2 Ft-3.14 0.O2 278 BrUh Doors Quantity Area R-Value lnfiltration Total Heal Loss No Doors U 0ft2 R-0 0 in2 Ceilings Quantity Area R-Value lnfiltration Total Heat Loss No Ceilings 0 0ft2 R-0 0 in2 Skylights Quantity Area R-Value lnfiltration Total Heat Loss No Skylights 0 0 ft2 R-0 0 in2 ** Heating load calculations used in Radiantworks are based on the ASHRAE 2009 Fundamentals Manual*t ** Snow melting calculations used in Radiantwo*s arc based on the ASHRAE 2007 HVAC Applications Manual ** Weathers Residence.rad Copyright(c) Watts Radiant 2018 Page 3 of 28 RadiantWorks Professional Design Report 612012025 Mud,Lndry Heat Loss Summary 24.1o/o 0.0olo E Tite:R-0.11 El Walll I Window'1 Ef No DoorslT] No Ceilings Etr No Skylights 75.9o/o Hall,Pwdr (Zone 2) Floor Coverings Quantity Area R-Value lnfiltration Total Heat Loss Hardwood- 3/4" : R-0.90 R-0.9 Walls Quantity Area R-Value lnfiltration Total Heat Loss Wall 1 1 81 ft2 R-21 0 556 BTU/h Windows Quantity Area R-Value lnfiltration Total Heat Loss Window 1 1 5ft2 R-3.'14 0.O2 144 BTUth Doors Quantity Area R-Value lnfiltration Total Heat Loss No Doors 0 0ft2 0 in2 Ceilings Quantity Area R-Value lnfiltration Total Heat Loss No Ceilings 0 0ft2 R-0 0 in2 ** Heating load calculations used in Radiantworks are based on the ASHRAE 2009 Fundamentals Manual**** Snow melting calculations used in Radiantworks are based on the ASHRAE 2007 HVAC Applications Manual ** Weathers Residence.rad Copyright(c) Watts Radiant 2018 Page 4 of 28 RadiantWorks Professional Design Report 6t20t2025 Skylights Quantity Area R-Value lnfiltration Total Heat Loss No Skylights 0 0ft2 R-0 0 in2 Hall,Pwdr Heat Loss Summary 2Q.5o/o O.0o/o I Hardwood- 3/4": R-0.90 J Walll I Window 1 f]]f No Doors t No Ceilings tr No Skylights 79.5o/o Zone Notes: u Heating load calculations used in HadiantWorks are based on the ASHBAE 2009 Fundamentals Manual** *r Snow meltlng calculations used ln Radiantworks are based on the ASHRAE 2007 HVAC Appllcations Manual ** Weathers ResidenCe.rad Copyright(c) Watts Radiant 2018 Page 5 of 28 RadiantWorks Professional Design Report 612012025 Zone 3 Design Application: Product: # of Circuits: Circuit Length: Manifold Distance Heated Area; Radiant Heating 1/2" RadiantPEX+ 2 175 ft 20 tt 182ft2 Supply Fluid Temp Delta T: Flow: Head: Radiant Capacity: Required Heat: Panel Load: % Glycol: 120'F 20 "F 0,4 GPM 0.4 ft 522s BTUih 3405 BTU/h 361B BTU/h 30V" Gonstruction - ThinSlab ThinSlab Thickness: ThinSlab Conductivity: 2in 2 BTrJ(h.ft..F) Subfloor Thickness: SLrbfloor Conductivity: 0.75 in 0.085 BTU(h.ft."F) Office (Zone 3) Floor Coverings Quantity Area R-Value lnfiltration Total Heat Loss Hardwood- 3/4" : R-0.90 R-0.9 Walls Quantity Area R-Value lnfiltration Total Heat Loss Wall 'l 1 216 tr2 R-21 1022BTUth Windows Quantity Area R-Value lnfiltration Total Heat Loss Window 1 1 64 tt2 R-3. 14 0.02 1697 BTU/h Doors Quantity Area R-Value lnfiltration Total Heat Loss No Doors n 0ft2 R-0 0 in2 Ceilings Quantity Area R-Value lnfiltration Total Heat Loss No Ceilings 0 0ft2 R-0 0 in2 Skylights Quantity Area R-Value lnfiltration Total Heat Loss No Skylights 0 0ft2 R-0 0 in2 *r Heating load calculations used in Radiantworks arc based on the ASHRAE 2009 Fundamentals Manual** ** Snow melting calculations used in Radiantworks arc based on the ASHBAE 2007 HVAC Applications Manual ** Weathers Residence.rad Copyright(c) Watts Radiant 20.18 Page 6 of 28 RadiantWorks Professional Design Report 6t20t2025 62.4o/o Office Heat Loss Summary O.Oo/o 37.60/o I Hardwood- 3/4": R-0.90 I Walll I Window 1l-l No Doors E No Ceilings tr No Skylights Zone Notes: Zone 4 Design Application: Product: # of Circuits: Circuit Length: Manifold Distance: Heated Area: Radiant Heating 1/2" RadiantPEX+ 2 250 ft 20ft 407 ft2 Supply Fluid Temp: Delta T: Flow: Head: Radiant Capacity: Required Heat: Panel Load: o/o Glycol: 1 '10 0F 20'F 0.67 GPM 1.1 ft 8883 BTU/h 5361 BTU/h 6095 BTU/tr 30% Construction - ThinSlab ThinSlab Thickness: ThinSlab Conductivity: 2in 2 BTU(h.ft."F) Subtloor Thickness: Subfloor Conductivity: 0.75 in 0.085 BTU(h.ft."F) Kit,Din,Pntry (Zone 4) Floor Coverings Quantity Area R-Value lnfiltration Total Heat Loss Hardwood- 3/4" : R-0.90 R-0.9 Walls Quantity Area R-Value lnfiltration Total Heat Loss Wall 1 1 360 ft,R-21 0 1737 BTUI\ Windows Quantity Area R-Value lnfiltration Total Heat Loss Window 1 1 62ft2 R-3.14 0.02 1645 BTU/h Doors Quanlity Area R-Value lnfiltration Total Heat Loss No Doors 0 0 ft2 R-0 0 in2 ** Heating load calculations used in RadiantWorks are based on the ASHRAE 2009 Fundamentals Manual** ** gnow melting calculations used in nadhntworks are based on the ASHRAE 2007 HVAC Applications Manual ** Weathers Residence.rad Copyright(c) Watts Radiant 2018 PageT oI28 RadiantWorks Professional Design Report 6120t2025 Ceilings Quantity Area R-Value Infiltration Total Heat Loss No Ceilings 0 0ft2 R-0 0 in2 Skylights Quantity Area R-Value lnfiltration Total Heat Loss No Skylights 0 0ft2 R-0 0 in2 Kit,Din,Pntry Heat Loss Summary I Hardwood- 3/4" : R-0.90 X Walll f Window 1l-l No Doors il No Ceilings I No Skylights Zone Notes: Zone 5 Design Application: Product: # of Circuits: Circuit Length: Manifold Distance Heated Area: Radiant Heating 1/2" RadiantPEX+ 5 230 ft 20 fr 514 ft2 Supply Fluid Temp Delta T: Flow: Head: Radiant Capacity: Required Heai: Panel Load: % Glycol: 132.F 20.F 1.5'1 GPM 1.3 ft 21562BIUth 12301 BTU/h 13764 BTU/h 3oo/o Gonstruction - ThinSlab ThinSlab Thickness: ThinSlab Conductivity: 2in 2 BTU(h.ft..F) Sulrfloor Thickr'ress. Subf loor Conduciivity: 0.75 in 0.085 BTU(h.ft..F) Grt Rm (Zone 5) Fioor eoverings Quantity Area R-Value lnfiltration Total Heal Loss Hardwood- 3/4" : R-0.90 R-0.9 Walls Quantity Area R-Value lnfiltration Total Heat Loss Wall 1 1 782fi2 R-21 0 3627 BTUth u Heating load calculations used in Radiantworks are based on the ASHRAE 2009 Fundamentals Manual**** Snow meltlng calculations used in Radiantworks arc based on the ASHHAE 2007 HVAC Applications Manual ** Weathers Residence.rad Copyright(c) Watts Radiant 2018 Page 8 of 28 RadiantWorks Professional Design Report 6120t2025 Windows Quantity Area R-Value lnfiltration Total Heat Loss Window'l 1 82ft2 R-3.14 0.02 2166 BTU/h Geilings Quantity Area R-Value lnliltration Total Heat Loss Ceiling 1 1 513.93 ft' R-49 0 908 BTU/h Doors Quantity Area R-Value lnfiltration Total Heat Loss No Doors 0 0 ft2 R-0 0 in2 Skylights Quantity Area R-Value lnfiltration Total Heat Loss No Skylights 0 0ft2 R-0 0 in2 Grt Rm Heat Loss Summary 32.3o/o 13.5o/o O.Oo/o I Hardwood- 3/4": R-0.90 X Walll tr Window 1 Ef Ceiling 1 E No Doors I No Skylights 54.1o/o Foyer (Zone 5) Floor Coverings Quantity Area R-Value lnfiltration Total Heat Loss Hardwood- 3i4" : R-0.90 R-0.9 Walls Quantity Area R-Value lnfiltration Total Heat Loss Wall 1 1 240'ltz R-21 U 1232 BTU/h Wall 2 1 120 tt2 R-21 775 BTU/h Windows Quantity Area R-Value lnfilration Total Heat Loss Window 1 1 42tP R-3.14 0.02 1122BTUth Ceilings Quantity Area R-Value Infiltration Total Heat Loss Ceiling 1 1 4'l .99 ft2 R-49 0 74 BTU/h ** Heating load calculations used in Hadlantworks arc based on the ASHFAE 2009 Fundamentals Manual** ** Snow melting calculations used ln Radiantworks are based on the ASHRAE 2007 HVAC Appltcations Manual ** Weathers Residence.rad Copyright(c) Watts Radiant 2018 Page I of 28 RadiantWorks Professional Design Report 612012025 Doors Total Heat LossQuantity Area R-Value lnfiltration No Doors 0 0ft2 R-0 0 ina Skylights Quantity Area R-Value lnfiltration Total Heat Loss No Skylights 0 0 ft2 R-0 0 in2 Foyer Heat Loss Summary 2.3o/o 35.0%I Hardwood- 3/4" : R-0.90 @ Walll tr Window 1l-l Ceilino 1 Eilf, Wall2 ElEl No Doors El No Skylights 38.5olo Zone Notes Zone 5 Design Application: Product: # of Circuits: Circuit Length: Manifold Distance: Heated Area: Radiant Heating 1/2" RadiantPEX+ 3 215 ft 20ft 252112 Supply Fluid Temp Delta T: Flow: Head: Radiant Capacity: Required Heat: Panel Load: % Glycol: 120 "F 20'F 0.75 GPM 0.5 ft 8640 BTUih 6772 BTUIh 7478 BTUh Oo/" Construction - ThinSlab ThinSlab Thickness: ThinSlab Conductivity: 2in 2 BTU(h.ft'"F) Subfloor Thickness: Su bf loor Conductivity: 0.75 in 0.085 BTU/(h.ft."F) M.Bed (Zone 6) Floor Goverings Quantity Area R-Value lnfiltration Tolal Heat Loss Carpet- Light w/ Pad : R-'1 .4 R-1 .4 Walls Quantity Area R-Value lnfiltration Total Heat Loss Wall 1 1 480 tt2 R-21 0 21BO BTU/h ** Heating load calculations used in Radiantworks are based on the ASHRAE 2009 Fundamentals Manual** ** Snow melting calculations used in Radiantworks arc based on the ASHRAE 2007 HVAC Applications Manual ** WeatherS ReSidenCe.rad Copyright(c) Watts Radiant 2018 Page 10 of 28 RadiantWorks Professional Design Report 6/20t2025 Windows Quantity Area R-Value lnfiltration Total Heat Loss Window 1 1 86 ft2 R-3.14 0.016 2270 gTulh Ceilings Quantity Area R-Value lnfillration Total Heat Loss Ceiling'l 1 251.86 tt' R-49 0 445 BTUth Doors Quantity Area R-Value lnfiltration Total Heat Loss No Doors 0 0 ft2 R-0 0 in2 Skylights Quantity Area R-Value lnfiltration Total Heat Loss No Skylights 0 0ft2 R-0 0 in2 M.Bed Heat Loss Summary 46.4o/o 1o/o 0-0o/o I Carpet- Lightw/ Pad : R-1.4 I Walll I Window 1l-1 Ceilino 1 EX No Doors I No Skylights M.Clts (Zone 6) Floor Goverings Quantity Area R-Value lnliltration Total Heat Loss Carpet- Light w/ Pad : R-1 .4 R-l .4 Walls Quantity Area R-Value lnfiltration Total Heat Loss Wall 1 1 60 ft2 R-21 0 446 BrUh Ceilings Quantity Area R-Value lnfiltration Total Heat Loss Ceiling 1 1 85.01 ft' R-49 0 150 BTU/h Windows Quantity Area R-Value lnfiltration Total Heat Loss No Windows 0 0ft2 R-0 0 in2 Doors Quantity Area R-Value lnfiltration Total Heat Loss No Doors 0 0ft2 R-0 0 in2 *r Heating load calculations used in Badiantwotks arc based on the ASHEAE 2009 Fundamentals Manual** ** Snow melting calculations used in Padlantworks are based on the ASHHAE 2007 HVAC Appllcations Manual ** WeatherS ResidenCe.rad Copyright(c) Watts Radiant 2018 Page 11 of28 RadiantWorks Professional Design Report 6t20t2025 Skylights Quantity Area R-Value lnfiltration Total Heat Loss No Skylights 0 0ft2 R.0 0 in2 M.Clts Heat Loss Summary 25.2o/o O.OVo I Carpet- Lightw/ Pad : R-1.4 D Walll I Ceiling 1 E NoWindows E No Doors X No Skylights 74.891, Zone Notes: ** Heating load calculations used in nadiantWorks are based on the ASHRAE 2009 Fundamentals Manual** ** Snow meltlng calculations used in RadiantWorks are based on the ASHRAE 2007 HVAC Applications Manual ** Weathers ResidenCe.rad Copyright(c) Watts Radiant 2018 Page 12 of 28 RadiantWorks Professional Design Report 6120t2025 Zone 7 Design Application: Product: # of Circuits: Circuit Length: Manifold Distance Heated Area: Radiant Heating 1/2" RadiantPEX+ 1 195 ft 20 lt 151 ft2 Supply Fluid Temp: Delta T: Flow: Head: Radiant Capacity: Required Heat: Panel Load: % Glycol: 110"F 20'F 0.33 GPM 0.7 ft 5502 BTU/h 2985 BTU/h 3266 BTU/h Oo/o Construction - ThinSlab ThinSlab Thickness: ThinSlab Conductivity: 2in 2 BTU(h.ft.'F) Subfloor Thickness: Subfloor Conductivity: 0.75 in 0.085 BTU(h.ft..F) M.Bath (Zone7) Floor Coverings Quantity Area R-Value lnfiltration Total Heat Loss Tile : R-0.11 R-0.11 Walls Quantity Area R-Value lnfiltration Total Heat Loss Wall 1 1 180 ft,R-2'1 0 906 BTUih Windows Quantity Area R-Value lnfiltration Total Heat Loss Window 1 1 48 ft2 R-3.14 0.016 1279 BrU/h Ceilings Quantity Area R-Value lnliltration Total Heat Loss Ceiling 1 1 151 .04 ft2 R-49 0 267 BTU/h Doors Quantity Area R-Value lnfiltration Total Heat Loss No Doors 0 0ft2 R-0 0 in2 Skylights Quantity Area R-Value lnfiltration Total Heat Loss No Skylights 0 0ft2 R-0 0 in2 ** Heating load calculations used in nadiantworks are based on the ASHBAE 20Ag Fundamentals Manual** ** Snow melting calculations used in nadiantworks are based on the ASHRAE 2007 HVAC Appllcations Manual *r Weathers ResidenCe. rad Copyright(c) Watts Radiant 201 B Page 13 oi 28 RadiantWorks Professional Design Report 6t20t2025 52.2o/o M.Bath Heat Loss Summary 10.90/o 0.0% I Tile : R-0.'11 f Walll I Window 1 El Ceiling 1 E No Doors il No Skylights Zone Notes Zone 8 Design Application: Product: # of Circuits: Circuit Length: Manifold Distance: Heated Area: Radiant Heating 1/2" RadiantPEX+ 2 250 ft 20ft 180 ft' Supply Fluid Temp: Delta T: FIow: Head: Radiant Capacity: Required Heat: Panel Load: 7o Glycol: 120 "F 20'F 0.58 GPM 0.7 ft 8397 BTU/h 4829 BTU/h 5791 BTU/h 0% Construction - ThinSlab ThinSlab Thickness: ThinSlab Conductivity 2in 2 BTU(h.ft..F) Subfloor Thickness: Subf loor Conductivity: 0.75 in 0.085 BTU(h'ft..F) Guest 1 (Zone 8) Floor Coverings Quantity Area R-Value lnfiltration Total Heat Loss Carpet- Light w/ Pad : R-1 .4 R-1 .4 Walls Quantity Area R-Value lnfiltration Total Heat Loss Wall 1 1 260 ftz R-21 0 1295 BTU/h Winciows Quantity Area R-Value lnfiltration Total Heat Loss Window 1 1 51 ft2 R-3.14 0.016 1357 BTU/h Ceilings Quantity Area R-Value lnfiltration Total Heat Loss Ceiling 1 1 180.1 ft, R-49 0 318 BTU/h "'Heating load calculations used in RadlantWorks are based on the ASTIRAE 2009 Fundamentals Manual**** Snow melting calculations used in nadiantwotks are based on the ASHRAE 2007 HVAC Applicalions Manual ** Weathers FleSidence.rad Copyright(c) Watts Radiant 2018 Page 14 of 28 RadiantWorks Professional Design Report 612012025 Doors Quantity Area R-Value lnfiltration Total Heat Loss No Doors 0 0 ft2 R-0 0 in2 Skylights Quantity Area R-Value lnfiltration Total Heat Loss No Skylights 0 0ft2 R-0 0 in2 Guest 1 Heat Loss Summary 45.7o/o 1O.7o/o I Carpet- Lightwl Pad : R-1.4 I Wall'l I Window 1 E3 Ceilins 1 il No Doors X No Skylights 0.oo/o 43.60/o Clst (Zone 8) Floor Goverings Quantity Area R-Value lnfiltration Total Heat Loss Carpet- Light wi Pad : R-1 .4 R-1 .4 Walls Quantity Area R-Value lnfiltration Total Heat Loss Wall 1 1 50 ft2 R-21 0 388 BTU/h Geilings Quantity Area R-Value lnfiltration Total Heat Loss Ceiling'1 1 33.99 ft2 R-49 0 60 BTU/h Windows Quantity Area R-Value lnfiltration Total Heat Loss No Windows 0 0ft2 R-0 0 in2 Doors Quantity Area R-Value lnfiltration Total Heat Loss No Doors 0 0 ft2 R-0 0 in2 ** Heating load calculations used in Radiantwo*s arc based on the ASHRAE 2009 Fundamentals Manual"* ** Snow melting calculations used in Badiantwotks are based on the ASHRAE 2007 HVAC Applications Manual ** Weathers Residence.rad Copyright(c) Watts Radiant 2018 Page 15 of 28 BadiantWorks Professional Design Report 6t20t2025 Skylights Quantity Area R-Value lnfiltration Total Heat Loss No Skylights 0 0ft2 R-0 0 in2 Clst Heat Loss Summary 13.4o/o 86.6% !!tr Carpet Light w/ Pad : R-1 .4 @ Walll X Ceiling'l l-1 No Windows H No Doors El No Skylights Bath (Zone 8) Floor Coverings Quantity Area R-Value lnfiltration Total Heat Loss Tile : R-0.11 R-0.11 Walls Quantity Area R-Value lnfiltration Total Heat Loss Wall 1 '1 50 ft,R-21 0 371 BTU/h Windows Quantity Area R-Value lnfiltration Total Heat Loss Window 1 1 4ftz R-3 14 0.016 116 BTU/h Ceilings Quantity Area R-Value lnfiltration Total Heat Loss Ceiling 1 1 55.95 ft2 R-49 0 99 BTU/h .* Heating load calculations used in Radiantworks are based on the ASHRAE 2009 Fundamentals Manual**** Snow melting calculations used in Radiantwotks are based on the ASHRAE 2007 HVAC Applications Manual ** Weathers ReSidenCe.rad Copyright(c) Watts Radiant 2018 Page 16 of 28 RadiantWorks Professional Design Report 612012025 Doors Quantity Area R-Value lnfiltration Total Heat Loss No Doors 0 0 ft2 R-0 0 in2 Skylights Quantily Area R-Value lnfiltration Total Heat Loss No Skylights 0 0ft2 R-0 0 in2 Bath Heat Loss Summary 19.8o/o 16.9o/o I Tile : R-0.11 tr Walll I Window 1 [3 Ceiling 1 E No Doors tr No Skylights 63.3o/o Zone Notes: Zone 9 Design Application: Product: # of Circuits: Circuit Length: Manifold Distance Heated Area: Radiant Heating 1i2" RadiantPEX+ 2 180 ft 20ft 149 ft' Supply Fluid Temp Delta T: Flow: Head: Radiant Capacity: Required Heat: Panel Load: % Glycol: 120 "F 20.F 0.35 GPM 0.3 ft 6008 BTU/h 2757 BTUh 3487 BTU/h o% Construction - ThinSlab ThinSlab Thickness: ThinSlab Conductivity: 2in 2 BTU(h.ft..F) Subfloor Thickness: Subfloor Conductivity 0.75 in 0.085 BTU(h.ft..F) Bedroom (Zone 9) Floor Coverings Quantity Area R-Value lnfiltration Total Heat Loss Carpet- Light wi Pad : R-1.4 R-1.4 Walls Quantity Area R-Value lnfiltration Total Heat Loss Wall 1 1 189 ft'R-21 U 1132 BTUIh ** Heatlng load calculations used in nadiantworks are based on the ASHRAE 2009 Fundamentals Manual** ** Snow melting calculations used in nadiantworks are based on the ASHRAE 2007 HVAC Applications Manual "* Weathers ReSidence.rad Copyright(c) Watts Radiant2018 Page 17 ol 28 RadiantWorks Professional Design Report 612012025 Windows Quantity Area R-Value lnfiltration Total Heat Loss Window 1 1 4 lt2 R-3.14 0.016 116 BTUih Ceilings Quantity Area R-Value lnfiltration Total Heat Loss Ceiling 1 1 149.08 ft' R-49 0 263 BTU/h Doors Quantity Area R-Value lnliltration Total Heat Loss No Doors 0 0ft2 R-0 0 in2 Skylights Quantity Area R-Value lnfiltration Total Heat Loss No Skylights 0 0 ft2 R-0 0 in2 Bedroom Heat Loss Summary 7.7s/o 17.4o/o I Carpet- Light M Pad : R-1.4 il Walll I Window 1l-1 Ceilino 1 I No Doors I No Skylights 74.9o/o Bath (Zone 9) Floor Coverings Quantity Area R-Value lnfiltration Total Heat Loss Tile : R-0.11 R-0,11 Walls Quantity Area R-Value lnfiltration Total Heat Loss Wall 1 1 5f) ft2 R-21 0 381 RTU/h Windows Quantity Area R-Value lnliltration Total Heat Loss Window 1 'l 4ft2 R-3,14 0.016 116 BTU/h Ceilings f)t tanlilrr Area Fl-\/alr re lnliltratinn Tnlal Heal I nce Ceiling 1 1 50.98 ft' R-49 0 90 BTU/h Doors Quantity Area R-Value lnfiltration Total Heat Loss No Doors 0 0ft2 R-0 0 in2 ** Heating load calculations used in Radlantworks are based on the ASHRAE 2009 Fundamantals Manual*"** Snow melting calculations used In Radiantworks are based on the ASHRAE 2007 HVAC Applicatlons Manual ** Weathers Residence.rad Copyright(c) Watts Radiant 2018 Page 18 of 28 RadiantWorks Professional Design Report 612012025 Skylights Quantity Area R-Value lnfiltration Total Heat Loss No Skylights 0 0 ft2 R-0 0 in2 Bath Heat Loss Summary 19.8o/o '.5.30/o 0.0% I Tile:R-0.11 tr Walll I Window 1l-1 Ceilino 1 I No Doors I No Skylights 64.9o/o Zone Notes: ** Heating load calculations used in BadiantWorks are based on the ASHRAE 2009 Fundamentals Manual** ** Snow melting calculations used h nadhntwotus are based on the ASHBAE 2007 HVAC Applications Manual ** Weathers Residence.rad Copyright(c) Watts Radiant 2018 Page 19 of 28 RadiantWorks Professional Design Report 612012025 Zone 1 0 Design Application; Product: # of Circuits: Circuit Length: Manifold Distance: Heated Area: Radiant Heating 1/2" RadiantPEX+ 2 195 ft 20ft 159 ft2 Supply Fluid Temp: Delta T: Flow: Head: Radiant Capacity: Required Heat: Panel Load: % Glycol: 120 "F 20 "F 0.43 GPM 0.4ft 7540 BTU/h 3989 BTU/h 4280 BTU/h 0V" Construction - ThinSlab ThinSlab Thickness: ThinSlab Conductiviiy 2in 2 BTU(h'ft'.F) Subfloor Thickness: Subfloor Conduoiivity: 0.75 in 0.085 BTLy(h'ft'aF) Bunk Rm (Zone 10) Floor Coverings Quantity Area Fl-Value lnfiltration Total Heat Loss Carpet- Light w/ Pad : R-1 .4 R-1 .4 Walls Quantity Area R-Value lnfiltration Total Heat Loss Wall '1 1 180 ft2 R-21 0 979 BTU/h Wlndows Quantity Area R-Value lntiltration Total Heat Loss Window 1 1 30 ft2 R-3.14 0.016 BO7 BTU/h Ceilings Quantity Area R-Value lnfiltration Total Heat Loss Ceiling 1 1 159.01 ft' R-49 0 281 BTU/h Doors Quantity Area R-Value lnfiltration Total Heat Loss No Doors 0 0ft2 R-0 0 in2 Skylights Quantity Area R-Value lnfiltration Total Heat Loss No Skylights n 0ft2 R-0 0 in2 ** Heating load calculations used in nadiantWorks are based on the ASHRAE 2009 Fundamentals Manual**** Snow meltlng cdlculations used in Radiantworks are based on the ASHRAE 2007 HVAC Applications Manuat ** WeatherS Residence.rad Copyright(c) Watts Radiant 2018 Page 20 of 28 RadiantWorks Professional Design Report 6t20t2025 39.0% Bunk Rm Heat Loss Summary 13.6% 0.0olo I Carpet- LightM Pad : R-1.4 il Walll I Window 1 Elf Ceiling 1 E No Doors X No Skylights Clst (Zone 10) Floor Coverings Quantity Area R-Value lnfiltration Total Heat Loss Carpet- Light w/ Pad : R-1 .4 R-1 .4 Walls Quantity Area R-Value lnfiltration Total Heat Loss Wall 1 1 40 ft2 R-21 0 336 BTU/h Ceilings Quantity Area R-Value ln{iltration Tolal Heat Loss Ceiling 1 1 43.03 ft2 R-49 0 76 BTU/h Windows Quantity Area R-Value lnfiltration Total Heat Loss No Windows 0 0ft2 R-0 0 in2 Doors Quantity Area R-Value lnfiltration Total Heat Loss No Doors 0 0fF R-0 0 in2 ** Heating load calculations used in Radiantwo*s arc ba6ed on the ASHPAE 2009 Fundamentals Manual** ** Snow melting calculations used in Radiantworks are based on the ASHRAE 2007 HVAC Applications Manual ** Weathers ResidenCe.rad Copyright(c) Watts Radiant 2018 Page 21 oI 28 RadiantWorks Professional Design Report 612012025 Skylights Quantity Area R-Value lnfiltration Total Heat Loss No Skylighis 0 0 ft2 R-0 0 in2 Clst Heat Loss Summary 18.50/o U Carpet- Light w/ Pad : R-1,4 @ Walll I Ceiling 1 Elf No Windows f-l No Doors Kl No Skylights 81.5olo Bath (Zone 10) Floor Coverings Quantity Area R-Value lnfiltration Total Heat Loss Tile : R-0.11 R-0.11 Walls Quantity Area R-Value lnfiltration Total Heat Loss Wall 1 1 100 ft2 R-21 0 668 BTU/h Ceilings Quantity Area R-Value lnfiltration Total Heat Loss Ceiling 1 1 50.98 ft' R-49 0 90 BTU/h Windows Quantity Area R-Value lnfiltration Total Heat Loss No Windows 0 0 ft2 R-0 0 in2 ** Heating load calculations used in Radiantwotks are based on the ASHRAE 2009 Fundamentals Manual"*** Snow melting calculations used in Radiantworks are based on the ASHRAE 2007 HVAC Applications Manual *" WeatherS ResidenCe.rad Copyright(c) Watts Radiant 2018 Page 22 ot 28 RadiantWorks Professional Design Report 6/20/2025 Doors Quantity Area R-Value ln{iltration Total Heat Loss No Doors 0 0ft2 R-0 0 in2 Skylights Quantity Area R-Value lnfiltration Total Heat Loss No Skylights 0 0 ft2 R-0 0 inz Bath Heat Loss Summary 11.9o/o E]]] Tile:R-0.11 [3 Walll @ Ceiling 1 l-] No Windows l-] No Doors E No Skylights Zone Notes: 88.1To Zone 1 1 Design Application: Product: # of Circuits: Circuit Length: Manifold Distance; Heated Area: Radiant Heating 1/2" RadiantPEX+ 2 225 ft 20 ft 281 ft2 Supply Fluid Temp: Delta T: Flow: Head: Radiant Capacity: Required Heat: Panel Load: % Glycol: 120 "F 20 "F 0.4 GPM 0.4 ft B92B BTU/h 3714 BTU/h 4040 BTU/h 0% Construction - ThinSlab ThinSlab Thickness: ThinSlab Conductivity: 2in 2 BTU(h.fr.'F) Subfloor Thickness: Subf loor Conductivity: 0,75 in 0.085 BTU(h.ft."F) Library (Zone 11) Floor Coverings Quantity Area R-Value lnfiltration Total Heat Loss Carpet- Light w/ Pad : R-1 .4 R-1 .4 Walls Quantity Area R-Value lnfiltration Total Heat Loss Wall 1 1 100 ft,R-21 0 61281U/h ** Heating load calculations used in Radiantworks are based on the ASHRAE 2009 Fundamentals Manual**.* Snow melting calculations used in RadiantWorks are based on the ASHBAE 2007 HVAC Applications Manual ** Weathers ReSidenCe.rad Copyright(c) Watts Radiant 2018 Page 23 of 28 RadiantWorks Professional Design Report 6t20t2025 Windows Quantity Area R-Value lnfiltration Total Heat Loss Window 1 1 17 112 R.3.14 0.01 6 464 BTU/h Ceilings Quantity Area R-Value lnfiltration Total Heat Loss Oeiling 1 1 280.9 ft' R-49 0 496 BTU/h Doors Quantity Area R-Value lnfiltration Total Heat Loss No Doors 0ft2 R-0 0 inz Skylights Quantity Area R-Value lnfiltration Total Heat Loss No Skylights 0 0ft2 R-0 0 in2 Library Heat Loss Summary 31.6% 29.5o/o J Carpet- Lightw/ Pad: R-1.4 il Walll I Window 1l-l Ceilino 1 E No Doors tr No Skylights Hall Bath (Zone 11) Floor Coverings Quantity Area R-Value lnliltration Total Heat Loss Tile : R-0.11 R-0..1 1 Walls Quantity Area R-Value lnfiltration Total Heat Loss Walll 1 40 ft2 B-?1 0 315 BTil/h Windows Quantity Area R-Value lnfiltration Total Heat Loss Window 1 1 5ft2 R-3.14 0.016 144 BTUth Ceilings Ouantitr-r Area R-Value lnfiltration Total Heat Loss Ceiling 1 1 50.98 ft' R-49 n 90 BTU/h Doors Quantity Area R-Value lnfiltration Total Heat Loss No Doors 0 0ft2 R-0 0 in2 it Heating load calculations used in RadiantWorks are based on the ASHRAE 2009 Fundamentals Manual** ** Snow meltlng calculations used in Radlantworks are based on the ASHRAE 2007 HVAC Applications Manual ** Weathers Residence.rad Copyright(c) Watts Radiant 2018 Page 24 ot 28 Radiantworks Professional Design Report 612012025 Skylights Quantity Area R-Value lnfiltration Total Heat Loss No Skylights 0 0ftz R-0 0 in2 Hall Bath Heat Loss Summary 26-1o/o 16.4o/o .Oo/o I Tile:R-0.11 @ Walll f Window 1l-1 Ceilino 1 flfl No Doors E No Skylights 57.SVo Zone Notes ** Heating load calculations used in Hadiantworks are based on the ASHRAE 2009 Fundamentals Manual** r* Snow melting calculations used in nadiantworks are based on the ASHRAE 2007 HVAC Applications Manual ** Weathers Residence.rad Copyright(c) Watts Radiant 2018 Page 25 ot 28 RadiantWorks Professional Design Report 612012025 Tone 12 Design Application: Product: # of Circuits: Circuit Length: Manifold Distance Heated Area: Radiant Heating 1/2" RadiantPEX+ 2 195 ft 20 ft 162 ft' Supply Fluid Temp: Delta T: Flow: Head: Radiant Capacity: Required Heat: Panel Load: % Glycol: 120'F 20'F 0.45 GPM 0.4 ft 5132 BTUih 4172BTU|h 4455 BTU/h 0% Construction - ThinSlab ThinSlab Thickness: ThinSlab Conductivity: 2in 2 BTU(h.ft'"F) Subfloor Thickness: Subf loor Conductivity: 0.75 in 0.085 BTU(h.ft.'F) Flex (Zone 12) Floor Coverings Quantity Area B-Value InJiltration Total Heat Loss Carpet- Light w/ Pad : R-1 .4 R-1 .4 Walls Quantity Area R-Value lnfiltration Total Heat Loss Wall 1 1 200 ft,R-21 0 930 BTU/h Windows Quantity Area R-Value lnfiltration Total Heat Loss Window 1 1 67 tI2 R-3.14 0.016 1775 BTUth Ceilings Quantity Area R-Value lnfiltration Total Heat Loss Ceiling 1 1 162.05 ft' R-49 0 286 BTU/h Doors Quanlity Area R-Value lnJiltration Total Heat Loss No Doors 0 0ft2 R-0 0 in2 Skylights Quantity Area R-Value lnfiltration Total Heat Loss No Skylights n 0ftz R-0 0 in2 ** Heating load calculations used in Radiantworks are based on the ASHRAE 2009 Fundamentals Manual** ** Snow melting cdlculations used in Radiantwotks are based on the ASHRAE 2007 HVAC Applications Manual ** Weathers Residence.rad Copyright(c) Watts Radiant 2018 Page 26 of 28 RadiantWorks Professional Design Report 6t20t2025 59.4o/o Flex Heat Loss Summary 9.60lo 31.1o/o I Carpet- Light M Pad ; R-1.4 f, Walll I Window 1l-1 Ceilino 1 il No Doors tr No Skylights Clst (Zone 12) Floor Goverings Quantity Area R-Value lnliltration Total Heat Loss Carpet- Light w/ Pad : R-1 .4 R-1 .4 Walls Quantity Area R-Value lntiltration Total Heat Loss Wall 1 1 64 tt2 R-21 0 480 BTU/h Ceilings Quantity Area R-Value lnfiltration Total Heat Loss Ceiling 1 1 43.03 ft2 R-49 0 76 BTU/h Windows Quantity Area R-Value lnfiltration Total Heat Loss No Windows 0 0ftz R-0 0 in2 Doors Quantity Area R-Value lnfiltration Total Heat Loss No Doors U 0ft2 R-0 0 in2 ** Heating load calculations used in nadiantwofus arc based on the ASHRAE 2009 Fundamentals Manual** ** Snow melting calculatlons used in Radiantworks arc based on the ASHRAE 2007 HVAC Applications Manual ** Weathers Residence.rad Copyright(c) Watts Radiant 20.18 Page 27 ol 28 RadiantWorks Professional Design Report 6t20t2025 Skylights Quantity Area R-Value lnfiltration Total Heat Loss No Skylights 0 0ft2 R-0 0 inz Clst Heat Loss Summary 13.7o1o I Carpet- Lightw/ Pad : R-l.4 I Walll I Ceiling'l E NoWindows il No Doors I No Skytights Zone Notes: Project Notes: 86.37o f Zone'l JZone2I Zone 3 El Zone 4 trI Zone 5 I Zone 6 ffi Zone 7 ffi Zone 8 @ Zone 9 f, Zone 10f*l Zone 11 @l Zone 12 Proiect Heat Load Summary 10o/o12o/o 1 1o/o 'l5o/o 5o/o 2o/o 60/o 7o/o 2Ae/o 6Vo 3o/o4o/a Pleasc vorify all project information for accuracy Signature:Date ** Heatlng load calculations used ln Radiantworks are based on the ASHBAE 2009 Fundamentats Manual**** Snovt melting calculatlons used in Radlantworks arc based on the ASHRAE 2007 HVAC,Appltcatlons Manual *" WeatherS ResidenCe.rad Copyright(c) Watts Radiant 2018 Page 28 of 28 RadiantWorks Professional Mechanical Summary Report 6t2012025 Project lnformation Project Number Project Quote Project Name Designed For : : i'i' ,l-:-i,, l ., : , ; :' | ] '' j I Contact lnformation Designed By Brent Hettinger Company Name George T. Sanders Company PhoneNumber 97O-468-8254 Project Assumptions Outdoor Temp -19 'F Elevation 6100 ft Wind Speed 10 mph Market Cat. Weathers Residence Carbondale, CO Pump Specs Zone Name Flow Head Manifold (*) Head Drop Supply Fluid TempDelta T Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone B Zone 9 Zone 10 Zone 11 Zone 12 2.5 GPM 0.4 GPM 0.4 GPM 0,7 GPM 1.5 GPM O.B GPM 0.4 GPM 0.6 GPM 0.4 GPM 0.5 GPM 0.4 GPM 0.5 GPM [0.254 ft] [0.01 ft] I0.01 ftl [0.023 ft] [0.097 ft] [0.03 ft] [0.01 ftl [0.017 ft] [0.01 ft] [0.012 ft] [0.01 ft] [0.012 ft] 4.3 ft 0.4 ft 0.4 ft 1.1 ft 1.3 ft 0.8 ft 1ft 1ft 0.4 ft 0.5 ft 0.5 ft 0.6 ft '1 10 'F 1 .10 "F 120'F 110'F 132'F 120'F 110 "F 120'F 120 "F 120 "F 120 "F 120 "F 20 20 20 20 20 20 20 20 20 20 20 20 $se \\c\ -\ \ \ Weathers Residence. rad Copyright(c) Watts Radiant 2008 Page 1 of 4 RadiantWorks Professional Mechanical Summary Report 6t20t2025 Heated Area Descriptions Application Construction Heated Area Product Totals Zone 1 o Room List (Garage) Radiant Heating Slab None 713 ft2 (4) 225' Lengths of 1 /2" RadiantPEX+ Zone 2 + Room List (Mud,Lndry, Hall,Pwdr) Radiant Heating ThinSlab None 296 ftz (2) 190'Lengths of 1/2" RadiantPEX+ Zone 3 €> Room List (Office) Radiant Heating ThinSlab None 182 tt2 (2) 175'Lengths of 1/2" RadiantPEX+ Zone 4 o Room List (Kit,Din,Pntry) Radiant Heating ThinSlahr None 407 ft2 (2) 250' I engths of 1 /2" RadiantPEX+ Zone 5 <> Radiant Heating ThinSlab None 604 ft2 (5) 230' Lengths of 1/2" RadiantPEX+ Zone 6 c Room List (M.Bed, M.Clts) Radiant Heating ThinSlab None 337 ft2 (3) 215'Lengths of li2" RadiantPEX+ ZoneT <> Room List (M.Bath) Radiant Heating ThinSlab None 151 ft2 (1) 195'Lengths of 1/2" RadiantPEX+ Zone B + Room List (Guest 1, Clst, Bath) Radiant Heating ThinSlab None 270 ft2 (2) 250'Lengths of 1/2" RadiantPEX+ Zone 9 G Room List (Bedroom, Bath) Radiant Heating ThinSlab None 200 ft,(2) 180' Lengths of 1/2" RadiantPEX+ Zone 10 o Room List (Bunl< Rm, Clst, Bath) Radiant Heating ThinSlab None 253w (2) 195'Lengths of 1i2" RadianiPEX+ Zone 11 + Room List (Library, Hall Bath) Radiant Heating ThinSlab None 332ft2 (2) 225'Lengths of 1/2" RadiantPEX+ Zone 12 <> Ruonr Lis[ (Flex, Clst) TlrinSlab None (2) 195'Lengthsof l/2" RadiantPEX+ Weathers Residence. rad Radiarrt Heating Copyright(c) Waits Radiant 2008 205 [t! Page 2 ot 4 RadiantWorks Professional Mechanical Summary Report 6/20t2025 Heating Load Summary Tube Spacing (in) lntensity (BTU/h.ft1 Back/Edge Losses (BTU/h'ft'z) Total Required (Bru/h) Total Provided (Bru/h) supp. Needed Zone 1 Garage 12 26.15 5.35 18647 18647 28600 28600 Zone2 Mud,Lndry Hall,Pwdr 12 12 10.81 9.96 1.79 1.81 3099 1914 1 185 8689 6443 2246 Zone 3 Office 18.71 1.17 3405 3405 5225 522s Zone 4 Kit,Din,Pntry 12 13.17 1.80 5361 5361 8883 8883 Zone 5 Grt Rm Foyer 8 8 17.7 35.59 2.30 3.1 0 12301 9098 3203 21562 1 8334 3228 Zone 6 M.Bed M.Clts B I 23.1 I 10.92 2.47 0.98 6772 5844 928 8640 6628 2012 ZoneT M.Bath 12 19.77 1.86 2985 2985 5502 5502 Zone 8 Guest 1 Clst Bath B 5 8 20.06 14.05 13.22 4.77 1.09 1.18 4829 361 0 478 741 8397 4709 880 2808 Zone 9 Bedroom Bath B 12 13.8 13.74 4.54 1.05 2757 2057 700 6008 3693 231 5 Zone 10 Bunk Rm Clst Bath '12 16.74 't 1.84 16.06 1.19 1.05 1.12 3989 2661 509 819 7540 3824 1 020 2696 I 8 Zone 11 Library Hall Bath 12 B 10.79 13.36 0.96 1.12 3713 3032 681 8927 6366 2561 Zone 12 Flex Clst 8 B 22.01 14.13 1.46 1.10 4172 3565 607 5132 4052 1 080 Project Summary Total Flow: Weathers Residence. rad 9.1 GPM Copyright(c) Watts Radiant 2008 Page 3 of 4 RadiantWorks Professional Mechanical Summary Report 612012025 Total System Head: Boiler Load: TotalSystem Volume Total Heated Area: 4.3 ft 82368 BTU/h 144 Gallons 3950 ft2 Please verify all project information for accuracy sig nature:Date Weathers Residence. rad Copyright(c) Watts Radiant 2008 Page 4 ol 4