HomeMy WebLinkAboutOWTS Permit
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945-6614 ext. 8150
For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: 322 Sun King Drive, Glenwood Springs, CO 81601 Parcel No.: 239521105006
Owner Name: David Hodgins Owner Phone: (970) 319-6611
Designed By: CBO, Inc. Designer Phone: (970) 309-5259
Contactor: Altitude Septic Contractor Phone: (970) 471-1330
Number of Bedrooms: _4_ Minimum Tank Capacity: 1,250-gallon Minimum Absorption: 612.5 ft2
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number _SEPT-9395_______________________________
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date _08/13/2025____________________ Expiration Date_08/13/2026_________________
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the report and design as
submitted by CBO, Inc. dated January 22, 2025. Changes to the design and permit must be approved
by Garfield County Public Health and the designer prior to construction.
The new OWTS will serve an existing three-bedroom residence and future 4th bedroom. An
additional soil profile pit shall be excavated and evaluated by the designer prior to installation of
the Soil Treatment Area (STA). A two-way cleanout shall be installed outside the building within 5-
feet of the building between the building and the septic tank. The new OWTS components will
consist of a new 1,500-gallon (1,250-gallon minimum) two compartment septic tank on the CDPHE
approved list, set level with access to grade and an effluent filter installed in the outlet tee of the
tank. Effluent will gravity flow to a new distribution box set level with access to grade which will
distribute effluent to 624 ft2 of STA. The new STA will consist of four gravelless chamber trenches,
each trench consisting of 13 ‘Quick 4’ chambers per trench (52 chambers total). Inspection ports will
be installed at each end of each trench. Maintain all setbacks and elevations as designed.
To assist in scheduling, please contact Garfield County Public Health (970-945-6614 ext. 8150) to
notify the start of OWTS construction. Contact the designer and Garfield County Public Health at
least 48 hours prior to requesting final inspection of the installed system prior to backfill. NO OWTS
COMPONENT SHALL BE BACKFILLED WITHOUT PRIOR APPROVAL FROM GARFIELD COUNTY PUBLIC
HEALTH AND THE DESIGNER.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction, and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection,
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as-built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
08/13/2025
Issued By: Garfield County Environmental Health
Department
Date