Loading...
HomeMy WebLinkAboutRescheck Energy ReportGenerated by REScheck-Web Software Com pl ia nce Certificate Project 826 County Road 237 (Montanez Barndominium) Energy Code: Location: Construction Type: Project Type: Project SubType: Conditioned Floor Area Glazing Area Climate Zone; Permit Date: Permit Number: All Electric ls Renewable Has Charger Has Battery: Has Heat Pump: 2018 rECC Rifle, Colorado Single-family New Construction None L,2OO it2 8o/o s (6881 HDD) false false false false false Construction Site: 825 County Road 237 silt, co 81652 Ceiling: Raised or Energy Truss Wall - Main Floor: Wood Frame, 16" o.c. Entry Door: Solid Door (under 5Oo/o glazing) Window: Metal Frame w/Thermal Break Garage Common: Wood Frame, 16" o.c. Floor: Slab-On-Grade (Unheated) lnsulation depth: 4.0' lnsulation position: Vertical lnsulation Owner/Agent:Desig ner/Contractor: Jeff Johnson jeff@jja rchitectura l.com \ $ Nl\ l+.' s\ .\n \ \l N Compliance: 10,37o Better Than Code Maximum UA: 194 Your UA: 174 The%BetterorWorseThanCodelndexreflects howclosetocompliancethehouseisbasedoncodetrade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements. Envelope Assemblies 2,320 1,100 24 135 500 140 49.0 26.0 19.0 0.0 0,0 0.020 0.052 0.330 0.300 0.060 0.026 0.060 0.300 0.300 0.060 46 49 I 41 30 60 56 4t 7 0.0 10.0 0.480 0.s40 30 0 0 Compliance: Passes using UA trade-off Cavity R-Value Cont. R-Value Prop. Req. U-Factor U-Factor Req UA Gross Area Assembly Perimeter Prop.or UA Project Title: 826 County Road 237 (Montanez Barndominium) Data filename: Report date: Il-lOLlz4 Page 1 of10 ROOM DETAIL Room name: Living Space Heated square footage: Cooled square footage: ' Heated volume (above grade CF): Cooled volume (above grade CF): Exposod wall area (SF): I@I@l!t@ r4@I@ Total Cooling BTUH: Total Heating BTUH: CFM: 20,000 @ @ @ Coulrrrg Heatlng 4,000 Load Calculation 10.000 AED Graph (mid-summer) 0 30,000 BTUH I F-o 2,000 6,000 4,000 2,000 0 8 9 10 11 - BTUH 12 13 14 15 16 17 18 - Average - Average * 1.3 19 AED graph (fall) > Pa 0 I 9 10 11 - BTUH 12 13 14 15 16 17 18 - Average - Average * 1.3 19 REScheck Software Version : REScheck-Web lnspection Checklist Energy Code: 2018 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Additional Comments/Assum ptions: Section # & Req.lD Pre-l nspection/Plan Review Plans Verified Value Field Verified Value Complies?Comments/Assumptions 103.1, 103.2 lPR1l1 .V/ Construction drawings and documentation demonstrate energy code compliance for the building envelope. Thermal envelope represented on construction documents. lComplies EDoes Not nNot Observable nNot Applicable Construction drawings and documentation demonstrate energy code compliance for lighting and mechanical systems. Systems serving multiple dwelling units must demonstrate compliance with the IECC Commercial Provisions. nComplies nDoes Not nNot Observable nNot Applicable 103.1, r03.2, 403.7 lPR3l1 !-ti Heating and cooling equipment is sized per ACCA Manual S based on loads calculated per ACCA Manual J or other methods approved by the code official. Heating: Btu/hr_ Cooling: Btu/hr Heati ng: Btu/hr_ Cooling: Btu/hr nComplies EDoes Not nNot Observable nNot Applicable 302.r, 403.7 lPR2l2 .AJ 1 ht (Tier 1)H 2 Medium I (Tier 2)3 Low lmpact (Tier 3) Project Title: 826 County Road 237 (Montanez Barndominium) Data filename: Report date: LLl0Ll24 Page 3 of10 Compliance Statemenil The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application, The REScheck Version : REScheck-Web and to comply with Amanda Poindexter, Energy Consultant Name - Title ng has been designed to meet the 2018 IECC requirements in listed in the REScheck lnspection Checklist. 111112024 Date ProjectTitle: 826 County Road 237 (Montanez Barndominium) Data filcnamc: Report date: lIlOIl24 Page 2 of10 S€ctlon # & Red.lD Foundation lnspection Plans Vorifled Value Field verified Val'ue Complies?CommEnts/Arsumptions 402.L.2 ;Slab edge insulation R-value lFol-]l i 8; R-_ ! Unheated I Heated R-_ I Unheated i I Heated nComplies lDoes Not ENot Observable !Not Applicable See fhe Envelope Assemblies table for values. 402.L.2 lFo3l1 & Slab edge insulation depth/length. ft ft nComplies nDoes Not nNot observable [JNot Applicable See the Envelope Assemblies table for values. 3r03,.2;l [Fo:m;a , :A protective covering is installed to protect exposed exterior insulation and extends a , minimum of 6 in. below grade. IComplies nDoes Not nNot Observable !Not Applicable nComplies lDoes Not nNot Observable ENot Applicable Additiona I Com ments/Assumptions: 1 High lmpact (Tier 1)z Medium lmpact (Tier 2)Jr Low lmpact (Tier 3) ProjectTitle: 826 County Road 237 (Montanez Barndominium) Data filename: Report date: LLlOLl24 Page 4 of10 Section # & Req.lD Framing / Rough-ln lnspection Plans Verified Value Field Verified Value Complies?Comments/Assumptions 402.r.1, 402.3.4 lFR1l1 ''ldr EComplies nDoes Not nNot Observable !Not Applicable Door U-factor See the Envelope Assemblies table for values. U-U. 402.L.r, 402.3.r, 4 02.3.3, 402.5 lFR2l1 'SJ !Complies nDoes Not nNot Observable ENot Applicable See the Envelope Assemblies table for values. U-U-Glazing U-factor (area-weighted average), Complies303.1.3 lFR4l1 t, 402.4.r.r lFR23l1 .9,, U-factors of fenestration products are determined in accordance with the NFRC test procedure or taken trom the default table. Air barrier and thermal barrier insta lled per manufacturer's i nstructions. !Complies nDoes Not !Not Observable !Not Applicable lDoes Not nNot Observable nNot Applicable 402.4.3 lFR20l1 'Sr Fenestration that is not site built is listed and labeled as meeting AAMA /WDMA/CSA 101/I.S.2I A44O or has infiltration rates per NFRC 400 that do not exceed code limits. nComplies lDoes Not nNot Observable nNot Applicable lC-rated recessed lighting fixtures sealed at housing/interior tinish and labeled to indicate <2.0 cfm leakage at 75 Pa. IComplies nDoes Not nNot Observable nruot Applicable 402.4.5 lFRr.6l2 Supply and return ducts in attics insulated >= R-B where duct is >= 3 inches in diameter and >= l R-6 where < 3 inches. Supply and I return ducts in other portions of ihe bLrilding insulated >= R-6 for : diameter >= 3 inches and R-4.2 i for < 3 inches in diameter. nComplies nDoes Not nNot Observable nNot Applicable 403.3.1 lFR12l1 tr' 403.3.2 lFR13l1 Sj Ducts, air handlers and filter boxes are sealed with joints/seams complia nt with lnternational Mechanical Code or lnternational Residential Code, as applicable. nComplies nDoes Not nNot Observable nNot Applicable 403.3.s lFR15l3 LJr Building cavities are not used as ducts or plenums. nComplies nDoes Not nNot Observable nNot npplicable 1 High lnrpact (Tier 1)2 Mediurrt lrlpact (Tier 2)3 Low lmpact (Tier 3) Project Title: 826 County Road 237 (Montanez Barndominium) Dato filename: Report date: L1,l0Il24 Page 5 of10 Section # & Req.lD Framing / Rough-ln lnspection Plans Verified Value Field Verified Value Complies?Comments/Assumptions 403.3.7 lFR28l3 '9, Ducts declared to be within the conditioned space are either 1) completely within the continuous air barrier and within the building thermal envelope, 2) buried within ceiling insulation in accordance with Section R403.3.6 and the air handler is located completely within the continuous air barrier and within the building thermal envelope and the duct leakage is <= 1.5 cfm / 100 square feet of conditioned floor area served by the duct system, or 3) the ceiling insulation R-value installed against and above the insulated duct >= to the proposed ceiling insulation R-value, less the R- value of the insulation on the nComplies lDoes Not nNot Observable nNot Applicable 403.4 lFR1712 ,.9 HVAC piping conveying fluids above 105 sF or chilled fluids below 55 eF are insulated to >R- 3. R-R nComplies nDoes Not nNot Observable nruot Applicable !Complies nDoes Not ENot Observable nNot Applicable 403.4.7 lFR24l1 Sr Protection of insulation on HVAC piping. 403.5.3 lFR18l2 .g Hot water pipes are insulated to >R-3. R R-nComplies nDoes Not nNot Observable !Not applicable 403.6 lFR1912 Automatic or installed on a gravity dampers are ll outdoor air nComplies lDoes Not nNot Observable nruot Applicable intakes and exhausts Additional Comments/Assum ptions: 1 High lmpact (Tier 1)2 Medium lmpact (Tier 2)3 Low lmpact (Tier 3) Project Title: 826 County Road 237 (Montanez Barndominium) Data filename: Report date: ILlOIl24 Page 6 of10 lns.ulation lnspection Plans Vorified \fatso:#camplies?Field Verlfied IV?trr6 I Corn m€nti/Assu rnpta ons 'All installed insulation is labeled ' or the installed R-valuesrprovided.EDoes Not LlNot Observable flNot epplicable lies 402.1,.I, 402.2.5, 402.2,6 ltN311 # R- nnn llComplies 'Ennes Nnt L_.lNot Observable L-Jruot npplicable ,See the Envelope Assemblies :table for values. , i Wnnd Mass sreelrequirenrer tI applies (FR10) Wall insulation R-value. lf this is a R- E wooo ! Mass n steet imass wall with at least % of the ;wall insulation on the wall : exterior, the exterior insulation ,Wall insulation is installed per man ufacturer's instructions. 303.2 lrN4l1 Complies Does Not Not Observable lNot Applicable Additiona I Comments/Assum ptions: 1 High lrrrpact (Tier 1) l.dt{Uettium tmpact (Tler 2)3,Low lmpact (lier J) Project Tltle: 826 County Road 237 (Montanez Barndominium) Data filename: Report date: LllOLl24 Page 7 ofL0 Section # & Req.lD Final lnspection Provisions Plans Verified Value Field Verified Value Complies?Comments/Assumptions 402.7.1, Ceiling insulation R-value 402.2.r, 402.2.2, 402.2.6 lFr1l1 R-_ ! Wood I Steel R-nComplies nDoes Not nNot Observable !Not Applicable see the Envelope Assemblies table for values.! Wood ! Steel 303.1.1.1, Ceiling insulation installed per 303.2 manufacturer's instructions. IFl2]1 Blown insulation marked every 300 ft,. nComplies nDoes Not nNot Observable nruot npplicable 402.2.3 IFt22]2 Vented attics with air permeable insulation include baffle adjacent to soffit and eave vents that extends over insulation. EComplies nDoes Not nNot Observable DNot Applicable 402.2.4 IFt3]1 Attic access hatch and door insulation >R-value of the adjacent assembly. R-_R nComplies nDoes Not nNot Observable ENot Applicable 402.4.r.2 I Fr17 ]1 Blower door test @ 50 Pa. <:5 ach in Climate Zones 1-2, and <:3 ach in Climate Zones 3-8. ACH 50 =ACH 50 nComplies nDoes Not flNot Observable nNot Applicable 403.3.3 [Ft27]r Ducts are pressure tested to determine air leakage with either: Rough-in test: Total leakage measured with a pressure differential of 0.1 inch w.g. across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test: Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. iP-cfm/100 ft-cfm/100 nComplies lDoes Not nNot Observable nNot Applicable 403.3.4 lFt4l1 Duct tightness test result of <:4 cfm/l00 ft2 across the system or <:3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in tests, verification may need to occur during Framing lnspection. cfm/100 F-cfm/100 EComplies nDoes Not ENot Observable nNot Applicable ft2 403.3.2.r lFt241r Air handler leakage designated by manufacturer at <=2o/o of design air flow. !Complies nDoes Not nNot Observable nNot Applicable 403.1.1 lFt9l2 Progra mmable thermostats installed for control of primary heating and cooling systems and initially set by manufacturer to code specifications. nComplies nDoes Not nNot Observable nruot Applicable 403.1.2 lFr 1012 Heat pump thermostat installed on heat pumps. lComplies nDoes Not !Not Observable nruot Applicable 403.5.1 I Ft11]2 Circulating service hot water systems have automatic or accessible manual controls. nComplies nDoes Not nNot Observable nNot Applicable 1 High lmpact (Tier 1)2 Medium lmpact (Tier 2)3 Low lmpact (Tier 3) Project Title: 826 County Road 237 (Montanez Barndominium) Data filename: Report date: IIlOLl24 Page 8 of10 Section # & Req.lD Final Inspection Provisions Plans Verified v dturj Field Verified vdtue Complies?Comments/Assumptions All mechanical ventilation system fans not part of tested and listed HVAC equipment meet efficacy and air flow limits per Table R403 .6. 1 . !Complies nDoes Not nNot Observable nNot Applicable 403.6.1 lFt25l2 Hot water boilers supplying heat through one- or two-pipe heating systems have outdoor setback control to lower boiler water nComplies nDocs NoL nNot Observable nNot Applrcable 403.2 tFr26t' temperature based on outdoor temperature. Heated water circulaLion systems ' have a circulation pump. The system return pipe is a dedicated reLurrr pipe or a cold wdter supply pipe. Gravity and thermos- syphon circulation systems are not present. Controls for circulating hot water system pumps staft the pump with signal for hot water demand within the lies403.5.1.1 lFr28l2 403.5.7.2 I trr?o 12 Electric heat trace systems comply with IEEE 515.1 or UL 515. Controls automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping. nComplies T-l^tluoes t\ot nNot Observable nNot Applicable occupancy. Controls automatically turn off the pump when water is in circr.rlation loop is at set-point temperature and no demand for hot water exists. nDoes Not nNot Observable nNot Applicable Demand recirculation water systems have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to <: 104qF. nComplies EDoes Not nNot Observable ENot Applicable 403.s.2 lFt30l2 Drain water heat recovery units tested in accordance with CSA 855.1. Potable water-side pressure loss of drain water heat recovery units < 3 psi for individual units connected to one or two showers. Potable water- side pressure loss of drain water IreaL recovery units < 2 psi for individual units connected to three or more showers. 403.5.4 lFtlrlz nComplies nDoes Not nNot Observable !Not Applicable flComplies nDoes Not nNot Observable nNot Applicable 404.r lFt6l1 90o/o or more of permanent fixtures have high efflcacy lamps. 404.r.1, lFr2313 p., nComplies l--ln^^- rr^* llNot Observable flNot Appllcahle Fuel gas lighting systems have no continuous pilot light. IComplies nDoes Not !Not Observable lNot Applicable Complia nce certificate posted401.3 [Ft712 1 Higlr lrrrpacL (Tier L)2 Medlum lmpact (Tier 2)3 Low lmpact ( lier J) Project -title: 82b County Road 237 (Montanez Barndominium) ha+- f,il^.-^.-^^.uoLo I ilct tdt I tE. Report date: LI|)Il24 Page 9 ofi0 Sectlon # & Rco.ID Final lnspection Provisions Plans Verified Valus Field Verified Value-Complies?Commonts/Assumptions 3,03,3 [Ftrgl! Manufacturer manuals for mechanical and water heating systems have been provided. flComplies ,nDoes Not 'flNot Observable nNot Applicable Additiona I Comments/Assumptions : 3 Low lm (Tier 3)1 High lmpact (Tier 1)Medium lm r2) Project Title: 826 County Road 237 (Montanez Barndominium) Data filename: Report date: IIlOll24 Page 10 of10 2018 IECC Energy Efficiency Certificate Above-Grade Wall Below-Grade Wall Floor Ceiling / Roof Ductwork (unconditioned spaces): Window Door Heating System Cooling System:_ Water Name: Comments 26.OO o.oo 10.oo 49.OO o.30 o.33 Date: lnsulation Rating R-Value Glass & Door Rating U-Factor SHGC Heating & Cooling Equipment Efficiency