Loading...
HomeMy WebLinkAboutBlower Door TestRetrotec rCloud 1 Quality Assurance Report Single Direction Multi Point Blower Door Test PASS Your Result: 1.54 ACH50 (202.16 CFM50 * 60 / 7869 ft³) Target < 3 ACH50 Test Information Test Name 101 Monument Ridge Rd ADU Test Date 2025-08-18 10:24 AM (MDT) Export id 9R3ESZSY Company Name Dexter Diagnostics Technician Name Amanda Poindexter Technician Email dexterdiagnostics@gmail.com Building Information Address 101 Monument Ridge Rd, ADU City Parachute State CO Zip/postal Code 81635 Country United States Year Constructed 2025 Elevation 5520 ft Address Verified?No Building Latitude, Longitude Your location has not been validated. GPS validation Tester location not verified Estimated Distance From Address Not available Test Equipment Fan Model Retrotec 5000 Fan Serial Number 5FN105365 Pressure Gauge Model Retrotec DM32X Gauge Serial Number 502769 Environmental Conditions Pre-test Indoor Temperature 70 °F Pre-test Outdoor Temperature 75 °F Wind Speed 5 MPH Average Barometric Pressure 101.325 kPa Test Dimensions Conditioned Floor Area 497 ft² Volume 7869 ft³ Retrotec rCloud 2 Test Results Summary Test Type Single Direction Multi Point Blower Door Test Flow Reference Pressure 50 Pa Time Averaging 10 seconds Corrected Flow 202.16 CFM @ 50 Pa Air Changes Per Hour 1.541 Percent Uncertainty 17.8% Correlation, r 0.812 Intercept 24.491 Slope, n 0.540 Test Results Test Data Set 1 Flow Direction Depressurize Gauge Location Inside Baseline, initial (Pa) -0.95 -0.92 -0.88 -0.87 -0.85 -0.84 -0.82 -0.82 -0.81 -0.8 Baseline Duration 10 seconds Average baseline -0.86 Pa Measured Pressure (Pa)-14.99 -22.9 -30.11 -37.04 Fan Pressure [5000 - B1] (Pa)77.16 62.25 88.05 113.02 Fan Pressure [5000 - B2] (Pa) Flow (CFM)125.31 112.66 134.23 153.65 Measured Pressure (Pa)-44.2 -52.48 -59.21 Fan Pressure [5000 - B1] (Pa) Fan Pressure [5000 - B2] (Pa)54.23 66.69 77.66 Flow (CFM)196.78 218.49 236.96 Baseline, final (Pa) 0.71 0.79 0.87 0.94 0.99 1.01 1.01 1 0.97 0.94 Baseline Duration 10 seconds Average baseline 0.92 Pa Retrotec rCloud 3 Test Notes No notes entered. Flow Equation Parameters - Retrotec Calibrated Flow Parameters Fan Last Calibrated:2024-09-11 Fan Model Retrotec 5000 Fan Serial Number 5FN105365 Fan Last Calibrated:2024-09-11 Units Used For Flow Parameters in Equation CFM Fan pressure (FP) is the measured fan pressure when using a self-referenced fan or when the room pressure is negative. If using a fan which is not self-referenced, and the room pressure is positive, fan pressure is calculated by subtracting the measured room pressure from the absolute value of the fan pressure. If PrA is greater than 0 or fan is self-referencing: FP = |PrB| - PrA If PrA is less than 0 or fan is self-referencing: FP = PrB Flow calculations are not valid if fan pressure is less than either MF or (K2 x |RP|) FP = fan pressure, RP = room pressure Range N K K1 K2 K3 K4 MF Open 0.4990 555.2054 0.0000 0.3000 0.0000 1 10 A 0.5030 290.8751 0.0000 0.4000 0.0000 1 20 B8 0.5270 121.5413 0.0000 0.7000 0.0000 1 35 flow = (FP - RP x K1)n x (K + K3 x FP) x K4 Range A B C D F G K2 MF B4 0.0000176573 -0.01530302 6.2742 138.42 0.59 50 0.8000 40 B2 0.0000025309 -0.00466154 2.7545 25.71 0.92 50 1.0000 50 B1 0.0000027369 -0.00313712 1.4891 10.71 0.45 50 1.0000 60 B74 0.0000007960 -0.00095010 0.5900 18.00 0.15 25 0.8000 35 B47 0.0000002690 -0.00035905 0.2435 12.05 0.09 25 1.0000 50 B29 0.0000001110 -0.00014900 0.0920 4.40 -0.02 25 0.6000 50 flow = (A x FP3) + (B x FP2) + (C x FP) + D +((G - RP) x F)