Loading...
HomeMy WebLinkAboutConditions of PermitcoNDrilo NS OF PERMIT BLRE-07-25-9366 Kyle & Stefanie Eckes Residential Basement Remodel 31 Sunlight View Dr, GWS Sunlight View Sub, Blk 3, Lot 3 - 239503203003 1) ALL WORK SHALL COMpLY W|TH THE 2015 INTERNATTONAL RESTDENTTAL CODE (t.R.c.)AND 2018 TNTERNATIONAL ENERGY CONSERVATION CODE (l.E.C.C.) 2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE ATTACHED "GARFIELD COUNTY BUILDING REOUIREMENTS". NUMBER REFERENCES NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST. 3) ELECTRTCAL PERMrrrNG AND TNSPECTTONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL ROUGH-IN APPROVAL IS REQUIRED AT FRAME INSPECTION ELECTRICAL FINAL APPROVAL IS REOUIRED FOR FINAL INSPECTION & CERTI FICATE OF OCCU PANCY. 4) ALL EXTERTOR LTGHTTNG TO BE DOWNCAST AND SHIELDED 5) WILDFIRE MITIGATION RECOMMENDATIONS: SHOULD COMPLY WITH WILDFIRE MITIGATION AND DEFENSIBLE SPACE REOUIREMENTS OF THE COLORADO STATE FOREST SERVICE AND LOCAL FIRE DISTRICT. SEE GARFIELD COUNry COMMUNIry DEVELOPMENT DEPARTMENT WEBSITE FOR FURTHER INFORMATION. 6) PROPOSED HABITABLE LIVING SPACES IN REMODELED BASEMENT MUST MAINTAIN MINIMUM 7 FT CEILING HEIGHT PER 2015 IRC SECTIONS R305, R305.1 EXCEPTIONS 1,2,3. EXISTING NON-HABITABLE AREAS OF BASEMENT MAY OTHERWISE MEET R305.1.1. BASEMENTS. CONTRACTOR AND PLUMBING INSTALLER SHALL FIELD VERIFY 6 FT B INCH HEADROOM CLEARANCE AT ALL NEW BATHROOM FIXTURES. 7) NO BATHROOM FTXTURE LAYOUT pROVtDED ON PROPOSED BASEMENT FLOOR PLANS. BATHROOM FIXTURES SHALL MAINTAIN MINIMUM FIXTURE CLEARANCES pER 2015 rRC FTGURE R307.1 (ATTACHED). 8) FTELD VERTFY LIGHT AND VENTILATION PROVIDED lN BASEMENT',OFFICE', pURSUANT 2015 rRC SECTTON R303 (8 PERCENT NATURAL LTGHT, 4 PERCENT AGGREGATE FLOOR AREA FOR NATURAL VENTILATION VIA OPERATIVE WINDOW / DOOR OPENING(S). sEE OVER (#9 - 13 CONTTNUES) \ \N N .{ e s %!" /of z 9) pROpOSED BASEMENT UTTLTTY ROOM SHALL MATNTATN ADEOUATE OUTSIDE COMBUSTION AIR FOR EXISTING / PROPOSED FUEL-FIRED EQUIPMENT. BUILDING APPLICATION FORM INDICATES 'NATURAL GAS' FUEL TYPE IN BASEMENT. ACCORDING TO GENERAL CONTRACTOR, BASEMENT UTILIry ROOM INCLUDES A WASHER, DRYER, LAUNDRY SINK, TANKLESS ON DEMAND WATER HEATER, WATER SOFTENER AND A FURNACE. CONTRACTOR SHALL ENSURE EXISTING / NEW APPLIANCES AND EOUIPMENT ARE INSTALLED PURSUANT TO MANUFACTURER'S INSTALLATION INSTRUCTIONS AND MAINTAIN ADEQUATE SERVICE MAINTENANCE CLEARANCE PER 2015 IRC M1202.1 and M1305.1 10)sMoKE AND CARBON MONOXTDE DETECTORS rN THE EXISTING HOME ARE TO MEET CURRENT CODE. IF WIRES CAN BE RUN WITHOUT REMOVING FINISHES, THEN HARDWIRED DETECTORS ARE MANDATORY. (IRC R314, R315) 1 1)cENERAL CONTRACTOR SUBMTTS NO ALTERING / MOVTNG / REPLACING / OR INSTALLATION OF NEW WINDOWS IN THE EXISTING BASEMENT. FROM PLAN SUBMISSION IT IS UNKNOWN THE SIZE, DIMENSION, FINISHED SILL HEIGHT, OR oPERATTVE ACTION AVATLABLE FROM THE BASEMENT FIVE (5) EXISTING WINDOWS. PROPERTY OWNER, IS ENCOURAGED, IF AND WHERE POSSIBLE TO CONSIDER INSTALLING ONE CODE COMPLIANCE EMERGENCY ESCAPE AND RESCUE OPENING FOR FUTURE. INASMUCH AS NO NEW BEDROOM IS REPRESENTED FOR INSTALLATION IN THIS REMODELED "OFFICE, CLOSET, BATHROOM, UTILITY CLOSET BASEMENT SPACE", THEN FLOOR PLAN HAS BEEN ACCEPTED UNDER 2015 IRC SECTION R310.6 ALTERATIONS OR REPAIRS TO AN EXISTING BASEMENT. CONVERSION FROM BASEMENT STORAGE TO BASEMENT LIVING OFFICE SPACE, LIMITS THE BASEMENT TO NO FUTURE BEDROOM USE OR OCCUPANCY. CURRENT AND FUTURE OWNERS ARE ADVISED OF THIS LIMITATION TO THE EXISTING BASEMENT AND SHALL PLAN USE(S)ACCORDINGLY. 12)BASEMENT OFFTCE (NOR ANy OTHER ROOM rN THE BASEMENT) SHALL NOT BE USED AS A FUTURE BEDROOM - UNLESS SUBJECT ROOM INCLUDES A CODE COMPLIANT EMERGENCY ESCAPE AND RESCUE OPENING R31O; SMOKE DETECTOR INSIDE THE ROOM, AND SMOKE DETECTOR / CARBON MONOXIDE ALARMS IN HALL OUTSIDE THE ROOM. 13)CONVERTING STORAGE SPACE TO OCCUPIABLE ROOM: COMPLIANCE WITH CURRENT INSULATION REOUIREMENTS FOR GARFIELD COUNryAND 2018IECC CLIMATE ZONE 58. MINIMUM R-20 INSULATION IN EXTERIOR WALL (OR EOUAL) IS REOUIRED. 7"f"Zo Fz