HomeMy WebLinkAboutConditions of PermitCONDITION OF PERMIT
BLRE-07 -25-937 0
Shining Light Services LLC
New Single-family dwelling w/ attached garage
21 4 Limberpine Circle, Battlement
Canyon View, Lot26
1) ALL WORK SHALL COMply W|TH THE 201s INTERNATIONAL RESIDENTIAL CODE (l.R.C.)AND 2018
I NTERNATIONAL ENERGY CONSERVATION CODE ( I.E.C.C.)
2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE
ATTACHED "GARFIELD COUNTY BUILDING REOUIREMENTS". NUMBER REFERENCES NOTED ON
PLANS REFER TO SPECIFIC ITEMS ON THIS LIST.
3) ELECTRICAL PERMITTING AND INSPECTIONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL
ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS
REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY.
4) ALL EXTERIOR LIGHTING TO BE DOWNCAST AND SHIELDED.
5) WILDFIRE MITIGATION RECOMMENDED: SHOULD COMPLY WITH WILDFIRE MITIGATION AND
DEFENSIBLE SPACE RECOMMENDATIONS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE
DISTRICT. PLEASE REFER TO THE GARFIELD COUNTY COMMUNIry DEVELOPMENT WEBSITE FOR
ADDITIONAL I N FORMATION.
6) OPEN HOLE SOTLS REPORT tS REOUTRED AT FOOTING INSPECTION AND PRIOR TO ANY CONCRETE
POUR. PROVIDE COPY OF GEOTECHNICAL ENGINEERS REPORT TO THE BUILDING INSPECTOR.
1,500 PSF soil bearing. lnclude compaction report if any structural fill pertains.
7) PRE-ENGTNEERED ROOF TRUSSES. HAVE ENGTNEERING FOR BUILDING INSPECTOR AT TIME OF
FRAME INSPECTION.
8) A LOT TMpROVEMENT CERTTFTCATE SEALED BY A COLORADO LICENSED SURVEYOR lS REOUIRED AT
FOUNDATION INSPECTION TO VERIFY STRUCTURE - INCLUDING PROPOSED ROOF OVERHANGS
DECKS AND OTHER PROJECTIONS - IS IN COMPLIANCE WITH MINIMUM SETBACKS AND /OR
BUILDING ENVELOPE REOUIREMENTS.
9) BLOWER DOOR TEST tS REOU|RED. MUST SUBMIT BLOWER DOOR TEST REPORT TO GARFIELD
COUNry COMMUNITY DEVELOPMENT DEPT. OFFICE PRIOR TO SCHEDULING FINAL BUILDING
INSPECTION / C.O. FINAL.
10) PRESCRIPTIVE PATH USING 2018 IECC Table R402.1.2 CHOSEN FOR ENERGY COMPLIANCE OF THIS
HOME. MANUAL J REPORT ALSO ATTACHED FOR REFERENCE. ALL NEW HOMES TO HAVE WHOLE-
HOUSE MECHANICALVENTILATION SYSTEM INSTALLED(2O15IRCTABLE M1507.3.3(1)AND(2)
SHOWN ON COVER SHEET.
$
"{rl
\e\t\
a\
\'s