Loading...
HomeMy WebLinkAboutSubsoils Report for Foundation DesignHuddleston-Berry ti,ngtr ne e r ing &' L estilng,, 7.X.,{) Shining Light Services PO Box 759 Fruita, Colorado 81521 Attention: Mr. Tyler Didonato Subject: Geotechnical Investigation 2T4Limberpine Circle Parachute, Colorado Dear Mr. Didonato, 2789 Riverside Parkway Grand Junction, Colorado 81501 Phone: 970-255-8005 Info@huddlestonberry. com June27,2022 Project#02490-0001 kil.ril.,f\ii:i i J{ij fJ $ llti::r ,. t. :: , r j: ..'. .i, . .,tt|,.1,,,',l,t.,,.iii This letter presents the results of a geotechnical investigation conducted by Huddleston-Berry Engineering & Testing, LLC (HBET) for 214 Limberpine Circle in Parachute, Colorado. The site location is shown on Figure I - Site Location Map. The proposed construction is anticipated to consist of a single-family residence. The scope of our investigation included evaluating the subsurface conditions at the site to aid in developing foundation recommendations for the proposed construction. Site Conditions At the time of the investigation, the site was open and fairly flat. Vegetation consisted of grasses and weeds. The site was bordered to the northwest by a vacant lot, to the northeast by Limberpine Circle, to the southwest by open land, and to the southeast by a residential property. Subsurface Investigation The subsurface investigation included one test pit at the site as shown on Figure 2 - Site Plan. The test pit was excavated to a depth of 8.0 feet below the existing ground surface. A typed test pit log is included in Appendix A. The test pit encountered 1.0 foot of topsoil above tan, dry to moist, soft to medium stiff silty clay with sand soils to a depth of 6.0 feet. The clay soils were underlain by tan, dry to moist, medium stiff to stiff silty clay with sand, gravel, cobble, and boulder soils to the bottom of the excavation. Groundwater was not encountered in the subsurface at the time of the investigation. Laboratorv Testins Laboratory testing was conducted on samples of the native soils collected from the test pit. The testing included grain-size analysis, Atterberg limits determination, natural moisture content determination, and maximum dry density and optimum moisture content (Proctor) determination. The laboratory testing results are included in Appendix B. il rt S-t*\ "\ s 214 Limberpine Circle #02490-0001 0612U22 The laboratory testing results indicate that the native clay soils are slightly plastic. In general, based on the Atterberg limits and our experience with similar soils in the vicinity of the subject site, the shallow native clay soils are anticipated to be slightly collapsible. Foundation Recommendations Based upon the results of the subsurface investigation and nature of the proposed construction, shallow foundations are generally recommended. Spread footings and monolithic (turndown) structural slab foundations are both appropriate alternatives. However, in order to provide a uniform bearing stratum and reduce the risk of excessive differential movements, it is recommended that the foundations be constructed above a minimum of 24-inches of structural fill. In addition, based upon information provided to HBET, a foundation from a previous structure may be present at the site. If an existing foundation is encountered during the new foundation excavation, the existing foundation should be completely removed and replaced with structural fill. The native clay soils, exclusive of topsoil, are suitable for reuse as structural fill; provided particles in excess of 3-inches in diameter are removed. Imported structural fill should consist of agranu|ar,non-eXpanSiue,w@g,materialapprovedbyHBET. For spread footing foundations, the footing areas may be trenched. However, for monolithic slab foundations, the structural fill should extend across the entire building pad area to a depth of 24- inches below the turndown edges. Structural fill should extend laterally beyond the edges of the foundations a distance equal to the thickness of structural fill for both foundation types. Prior to placement of structural fill, it is recommended that the bottom of the foundation excavation be scarified to a depth of 6 to 8 inches, moisture conditioned, and compacted to a minimum of 95%o of the standard Proctor maximum dry density, within +2%o of the optimum moisture content as determined in accordance with ASTM D698. Structural filI should be moisture conditioned, placed in maximum 8-inch loose lifts, and compacted to a minimum of 95%o of the standard Proctor maximum dry density for fine grained soils and 90o/o of the modified Proctor maximum dry density for coarse grained soils, within t2o/o of the optimum moisture content as determined in accordance with ASTM D698 and D1557, respectively. Structural fill should be extended to within O.l-feet of the bottom of the foundation. No more than 0.l-feet of gravel should be placed below the footings or turndown edge as a leveling course. For structural fill consisting of the native soils or imported granular materials, and foundation building pad preparation as recommended, a maximum allowable bearing capacity of 1,500 psf may be used. In addition, a modulus of subgrade reaction of 150 pci may be used for structural fill consisting of the native soils and a modulus of 200 pci may be used for suitable imported structural fill. Foundations subject to frost should be at least 36 inches below the finished grade. Water soluble sulfates are common to the soils in Western Colorado. Therefore, at a minimum, Type I-II sulfate resistant cement is recommended for construction at this site. @tr*,**Y*n# 2Z:V008 AIL PROJECTS\02490 - Shining Light SeNices\02490-000 I 2 1 4 Limberpine Circle\200 - Geo\02490-000 I LR062 I 22 doc 214 Limberpine Circle #02490-0001 06t21/22 Any stemwalls or retaining walls should be designed to resist laterul earth pressures. For backfill consisting of the native soils or imported granular, non-free draining, non-expansive material, we recommend that the walls be designed for an equivalent active fluid unit weight of 45 pcf in areas where no surcharge loads are present. An at-rest equivalent fluid unit weight of 65 pcf is recommended for braced walls. Laterul earth pressures should be increased as necessary to reflect any surcharge loading behind the walls. Non-Structural Floor Slab and Exterior Flatwork Recommendations In order to limit the potential for excessive differential movements of slabs-on-grade it is recommended that non-structural floating floor slabs be constructed above a minimum of 18- inches of structural filI with subgrade preparation and fill placement in accordance with the Foundation Recommendations section of this report. It is recommended that exterior flatwork be constructed above a minimum of 12-inches of structural fiIl. Drainase endations Grading and drainase are critical to the lons-term performunce of the structure. Grading around the structure should be designed to carry precipitation and runoff away from the structure. It is recommended that the finished ground surface drop at least twelve inches within the first ten feet away from the structure. It is also recommended that landscaping within five feet of the structure include primarily desert plants with low water requirements. In addition, it is recommended that automatic irrigation, including drip lines, within ten feet of foundations be minimized. HBET recommends that surface downspout extensions be used which discharge a minimum of 15 feet from the structure or beyond the backfill zone, whichever is greater. However, if subsurface downspout drains are utilized. they should be carefully constructed of solid-wall PVC and should daylight a minimum of 15 feet from the structure. In addition, an impermeable membrane is recommended below subsurface downspout drains. Dry wells should not be used. General Notes The recommendations included above are based upon the results of the subsurface investigation and on our local experience. These conclusions and recommendations are valid only for the proposed construction. As discussed previously, only one test pit was conducted at the site. Therefore, the precise nature and extent of subsurface variability may not become evident until construction. As a result, it is recommended that HBET provide construction materials testing and engineering oversight during the entire construction process. In addition, the homeowner and any subcontractors working on the project should be provided a copy of this report and informed of the issues associated with the presence of moisture sensitive subgrade materials at this site. HuddlesistuBsft! 6^t1ne.d^t & 1.11ilte, t-LC JZ:\2008 ALL PROJECTS\02490 - Shining Light Services\02490-0001 214 Limberpine CircleU00 - G@\02490-0001 LR062122.doc 214 Limberpine Circle #02490-0001 0612U22 It is important to note thut the recommendations herein are intended to reduce the risk of structural movement and/or damagq to varving deqrees. associated with volume chanqe of the native soils. However. HBET cannot lons-term chunses in subsurface moisture AW Huddlestm-Bet"y E^Sl&tinq & 1.t1il$j ,L<: conditions and/or the nrecise or extent of volume chanse.Where sisnificant increuses in subsurfsce moisture occur due to Door grading, imDroper stormwater management, utilitv line fuilure, excess irrigation, or other cause. either during construction or the result of actions of the propertv owner, several inches of movement are oossible. I! addition. anv failure to complv with the recommendations in this report releases lluddleston- Berrv Ensineerins & Testins, LLC of anv liabilitv with resard to the structure performance. We are pleased to be of service to your project. Please contact us if you have any questions or comments regarding the contents of this report. Respectfully Submitted: Huddleston-Berry Engineering and Testingo LLC Michael A. Berry, P.E. Vice President of Engineering 4Z:D008 ALL PROJECTS\02490 - Shining Light Services\02490-0001 214 Limberpine CircleV00 - Geo\02490-0001 LR062122.doc *,t qVublic-n&"' G a rf ie I d Cou nty, CO Dale crealed:5/6/2Q22 Last Data Uploaded:5/6/2022 3:52:30 AM FIGURE 1 Site Location Map Deveroped buffi$gfupider # ryPlublic,,n&** G a rf i e I d Cou nty, Co Date crealed:5/6/2Q22 Last Data Uploaded:5/6/2022 3:52:30 AM FIGURE 2 Site Plan Deveroped**9WWri#x BH COLUMNS 02490-OOO1 214 LIMBERPINE CIRCLE.GPJ GINT US LAB.GDT 6/20/22 !7oc mo{zc =trmv otr mz-{ r)zl. :Jc-ot ,a o e.ooa oN5(oo ooo € A l..J Fl{:i{= .'-3s* ! e? 3oo5 o O 8 8.4. ioo aw5@o ^ ^Y!2oFs, -<04G-H 0q F-o E go |--o !voL mo{ t-oo + o-z T s) q) 5c JD oo !7oL mo-{z =m N) 5 tr 36o p. fo a 9-o -{m @{ 3{zc =-oE>m i-,4n-+qP -l zo{mv, t-ooomo Ip --{ c) mxo -.16z =m-{Ioo mxo -{6z ooz-{n o{on tr'{m U,{ n{ mg (t N)(o NN-t ql oF5 @DoxJoo € @o g) Joo+ moxmo ID u, oo =!t-m-{m tr, ()r N NN ono>>>9fllE #q#E6YqI Errne=Eh| 99 ono Lzg mt-m { 6z o ?o ? {mo-l!-{LNm P3 DEPTH (ft) GRAPHIC LOG --{ m7 r-o maon -o -loz SAMPLE ryPE NUMBER RECOVERY % (ROD) BLOW COUNTS (N VALUE) POCKET PEN. (tsf) DRY UNIT WT (pc0 MOISTURE coNTENT (%) --{ =d--l tE@mno FINES CONTENT ek) LIQUID LIMIT PLASTIC LIMIT PLASTICITY INDEX { ti - P- . l\-.' t,J y-. l; 1;=.'l*;i:-. tz-. Jr-. -ti- q a o) €. 5 o (Eof. oa -lo-uao r- o @-r- o)oa q)a 9.. oo 3q.o=9.< =olr-.24-1+=. f CN otfo- or- r-v 0)5 o d o ==; .e o f 6:+ ao = -e -o@ o) N@ N)I\) \t @(, a- 0t\<= o^ JO9.<92 fr$u)o0r ==J- aA4-+O e6.aP +s, o6oI g) :f CL Eocoo a 9- 3* o, = @o o 3 o o6 E. A' 90o oo a+ Nq o E @ Foq mI @f Fz(, qq UJOt d UzdxUo Huddleston-Berry Engineering & Testing, LLC 2789 Riverside Parkway Grand Junction, CO 81501 970-255-8005 GRAIN SIZE DISTRIBUTION CLIENT Shininq Liqht Services PROJECT NAME 214 Limberpine Circle PROJECT NUMBER 02490-OOO1 PROJECT LOCATION Parachute, CO U.S. SIEVE OPENING IN INCHES I U.S. SIEVE NUIVIBERS I 1t23t8 3 4 6 810 1416 20 30 40 50 60 100140200 HYDROMETER6 4 3 21.5 1 FI(t L,IJ =m t UIz tL Fz uJ Ot uJ o- 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5 0 100 10 1 GRAIN SIZE IN MILLIMETERS 0.1 I +I tl t t- I COBBLES GRAVEL SAND SILT OR CLAY coarse fine coarse medium fine Specimen ldentification Classification LL PL PI Cc Cu o TP-1, GB-l 5t29 SlLry CLAY with SAND(CL-ML)29 22 7 Specimen ldentification D100 D60 D30 D10 %Gravel %Sand %sitt o/rClay o TP-l, GB-l 5129 19 3.6 13.3 83.1 Huddleston-Berry Engineering & Testing, LLC ATTERBERG LIMITS' RESULTS Riverside Parkway Junction, CO 81501 970-255-8005 CLIENT Shinino Lioht Services PROJECT NAME 214 Limberpine Circle PROJECT NUMBER 02490-0001 PROJECT LOCATION Parachute. CO P L S T I c I T I N D E X 50 40 30 20 10 CL-ML @ @ 0 0 60 LIQUID LIMIT 80 100 Specimen ldentification LL PL PI #200 Classification o TP.l, GB.1 5t29 29 22 7 83 SlLry CLAY with SAND(CL-ML) NNoN @ tsoo at J @l tszo LodJ (-) E6uzdEUE = N oooo No NN oN @ Foq m J al Fz o &quJOE Ou2dtru m: N oooo No zo Fo 0 oo MOISTURE-DENSITY RELATIONSHIP PROJECT NAME 214 Limberpine Circle PROJECT LOCATION Parachute, COPROJECT NUMBER 02490-000'1 CLIENT Shinino Lioht Services Huddleston-Berry Engineering & Testing, LLC Riverside Parlavay Grand Junction, CO 81501 970-255-8005 ul \ \ \ \ \ \ \ \ \ \ \ / / I Sample Date: Sample No.: Source of Material: Description of Material: 5t29t2022 2 145 TP.1 GB.1 SlLry CLAY with SAND(CL-ML) Test Method (manual):ASTM D698A 140 135 TEST RESULTS Maximum Dry Density {08'0 PCF Optimum Water Content 15'O % 130 GRADATTON RESULTS (% PASSTNG) 125 #200 83 #4 96 314" 100 F(/)z IUo to ATTERBERG LIMITS 1 20 LL PL PI 29 22 7 115 Curves ol 100o/o Saturation for Specific Gravity Equal to: 110 2.80 2.70 2.60 105 '100 95 5 15 WATER CONTENT, % 90 0 10 20 25 30