HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT
BLRE-07 -25-9343
KYLE & JILL BYMAN
New Single-family dwelling w/ attached garage & adjacent detached garage
213 CR 228, Silt - 239503106010
ALL WORK SHALL COMPLY WITH THE 201s TNTERNATTONAL RESTDENTTAL CODE (r.R.C.) AND 2018
TNTERNATTONAL EN ERGY CONSERVATTON CODE (r.E.C.C.)
PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE
ATTACHED "GARFIELD COUNTY BUILDING REOUIREMENTS". NUMBER REFERENCES NOTED ON
PLANS REFER TO SPECIFIC ITEMS ON THIS LIST.
ELECTRICAL PERMITTING AND INSPECTIONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL
ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINALAPPROVAL IS
REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY.
ALL EXTERIOR LIGHTING TO BE DOWNCAST AND SHIELDED.
WILDFIRE MITIGATION RECOMMENDATIONS: SHOULD COMPLY WITH WILDFIRE MITIGATION AND
DEFENSIBLE SPACE RECOMMENDATIONS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE
DISTRICT. PLEASE REFER TO THE GARFIELD COUNry COMMUNITY DEVELOPMENT WEBSITE FOR
ADDITIONAL INFORMATION.
OPEN HOLE SOILS REPORT IS REOUIRED AT FOOTING INSPECTION AND PRIOR TO ANY CONCRETE
POUR. PROVIDE COPY OF GEOTECHNICAL ENGINEERS REPORT TO THE BUILDING INSPECTOR.
1,500 PSF soil bearing.
PRE-ENGINEERED ROOF TRUSSES. HAVE ENGINEERING FOR BUILDING INSPECTOR AT TIME OF
FRAME INSPECTION.
SEPTIC SYSTEM REVIEW / APPROVALS: PRIOR TO BUILDING INSPECTION & CERTIFICATE OF
OCCUPANCY PROVIDE FINAL APPROVAUSIGN.OFF FROM GARFIELD COUNry'S PUBLIC HEALTH
DEPT.
ROAD & BRIDGE DRIVEWAY REVIEW / APPROVALS: PERMIT GRB25-D-12. PRIOR TO FINAL BUILDING
INSPECTION & CERTIFICATE OF OCCUPANCY PROVIDE FINAL APPROVAL / SIGN.OFF FROM
GARFTELD COUNryS ROAD & BRIDGE DEPT. CALL (970) 625-8601 AND HAVE ROAD & BRTDGE S|GN
THE PERMIT INSPECTION CARD.
PROPANE FUEL ryPE SPECIFIED - SEE ATTACHED GUIDE.
VERIFY SPACE ABOVE THE GARAGE FULLY COMPLIES WITH 2015 IRC TABLE R302.6 AND SECTIONS
R302.5.1 AND R31 ,I.1 MEANS OF EGRESS. LIVING SPACE MUST HAVE AN EXIT DOOR TO EXTERIOR
YARD WITHOUT TRAVEL THROUGH A GARAGE OCCUPANCY. OPENINGS FROM A PRIVATE GARAGE
DIRECTLY INTO A ROOM USED FOR SLEEPING PURPOSES SHALL NOT BE PERMITTED. VERIFY
RESIDENTIAL STAIR AND FIRE-RATED GARAGE DOOR(S)COMPLETED PER AMENDED
ARCHITECTURAL SHEETS DATED AUGUST 19,2025 (STUDIO M).
BLOWER DOOR TEST IS REOUIRED. MUST SUBMIT BLOWER DOOR TEST REPORT TO GARFIELD
COUNTY COMMUNIry DEVELOPMENT DEPT. OFFICE PRIOR TO SCHEDULING FINAL BUILDING
INSPECTION / C.O. FINAL.
PRESCRIPTIVE PATH USING RESCHECK SOFTWARE IS CHOSEN FOR ENERGY COMPLIANCE OF THIS
HOME. MANUAL J REPORT ALSO ATTACHED FOR REFERENCE. ALL NEW HOMES TO HAVE WHOLE-
HOUSE MECHANICAL VENTILATION SYSTEM INSTALLED (201s IRC TABLE m1507.3.3(1)AND (2)
SHOWN ON COVER SHEET.
BLRE-07-25-9343 REVIEWED AND PROCESSED AS THE PROPERTY'S PRIMARY RESIDENCE. THERE IS A
SEPARATE DEMOLIION PERMIT (DEMO-07-25-9346 ) FOR AN 1,700 SO FT OLDER HISTOR|C HOME.
TWO RESIDENCES CANNOT BE OCCUPIED CONCURRENTLY WITHOUT A LAND USE CHANGE PERMIT
(EXCEEDS 1,200 SO FT ADU USE BY RIGHT). PURSUANT TO THE DEMOLITION PERMIT AND Ai .1
REPRESENTATIONS. THE HISTORIC HOME SHALL NO LONGER BE AN OCCUPIABLE BUILDING
STRUCTURE WHEN A BUILDING FINAL / CERTIFICATE OF OCCUPANCY IS ISSUED FOR THE NEW
PRIMARY RESIDENCE. BUILDING PERMIT BLURE-07-25-9343 IS ISSUED IN GOOD FAITH THE
PROPERry OWNER'S COMPLETE THE DEMOLITION OF THE OLDER HOME AS DESCRIBED.
1)
2)
3)
4)
s)
6)
7)
8)
e)
10)
11)
12)
13)
14)
$
{t-'t
-\
-\\