HomeMy WebLinkAboutRescheck ReportGenerated by REScheck-Web Software
Com pl ia nce Certificate
Project Kyle & Jill Byman
Energy Code:
Location:
Construction Type:
Project Type:
Project SubType:
Orientation:
Conditioned Floor Area
Glazing Area
Climate Zone:
Permit Date:
Permit Number:
All Electric
ls Renewable
Has Charger
Has Battery:
Has Heat Pump:
2018 rECC
Silt, Colorado
Single-family
New Construction
None
Bldg, faces O deg. from North
3,546 ft2
9o/o
5 (6881HDD)
false
false
false
false
false
Owner/Agent:
N
.N
Construction Site:
213 county rd 228
silt, CO 81652
Up Stairs Ceiling: Flat Ceiling or Scissor Truss
2nd Level EAST Wall: Wood Frame, 16" o.c.
Orientation: Right side
2nd Level EAST Wall Windows: Vinyl Frame
Orientation: Right side
2nd Level North Wall: Wood Frame, L6" o.c.
Orientation: Right side
2nd Level North Wlndows: Vinyl Frame
Orientation: Right side
2nd Level WEST Wall: Wood Frame, l-6" o,c.
Orientation: Left side
Designer/Contractor:
Mic Baca
Studio M Engineers
970 366 8690 $
\
oN
Compliance: O.Oolo Better Than Code Maximum UA: 5Oo Your UA: 5OO
The % Better or Worse Than Code lndex reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home
Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade
assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements.
Envelooe Assemblies
2,927
514
12
434
34
434
0.026
0.059
0.300
0.059
0.300
0.059
49.0
20.0
0.0
0.0
0.026
0.060
0.300
0.060
0.300
0.060
20.0 0.0
76
30
4
24
1"0
25
76
30
4
24
10
25
Passes using UA trade-off
Cavity Cont, Prop, Req. Prop. Req,
R-Value R-Value U-Factor U-Factor UA UA
Gross Area
Assembly or
Perimeter
20.0 0.0
Report dateProject Title: Kyle & Jill Byman
Data filename:
: 06123125
Page L of 2
Gross Area
or
Perimeter
Cavity
R-Value
Cont,
R-Value
Prop, Req.
U-Factor U-Factor
Prop,
UA
Req
UAAssembly
2nd Level WEST Windows: Vinyl Frame
Orientation: Left side
2nd Level South Wall: Wood Frame, 16" o.c.
Orientation: Front
Window: Vinyl Frame
Orientation: Front
Ist Level EAST Wall: Wood Frame, 16" o.c.
Orientation: Right side
Lst Level EAST Wall Door: Solid Door (under 50%
glazing)
Orientation: Right side
1st Level EAST Wall Windows: Vinyl Frame
Orientation: Right side
1st Level North Wall: Wood Frame, 16" o.c.
Orientation: Back
Door: Solid Door (under 50% glazing)
Orientation: Back
1st Level North Wall Windows: Vinyl Frame
Orientation: Back
1st Level WEST Wall: Wood Frame, 16" o.c.
Orientation: Left side
Door 1: Solid Door (under 507o glazing)
Orientation: Left side
1st Level WEST Wall Windows: Vinyl Frame
Orientation: Left side
1st Level South Wall: Wood Frame, 16" o.c.
Orientation: Front
Window 1 Copy: Vinyl Frame
Orientation: Front
2X8 north Wall: Wood Frame, 16" o.c.
Orientation: Back
Window 1: Vinyl Frame
Orientation: Back
WEST Foundation Wall: Solid Concrete or Masonry
Wall height: 3.5'
Depth below grade: 3.0'
lnsulation depth: 3.5'
South Crawl Space Wall: Solid Concrete or Masonry
Wall height: 3.5'
Depth below grade: 3.0'
lnsulation depth: 3.5'
EAST Crawl Space Wall: Solid Concrete or Masonry
Wall height: 3.5'
Depth below grade: 3.0'
lnsulation depth: 3.5'
North Crawl Space Wall: Solid Concrete or Masonry
Wall height: 3.5'
Depth below grade: 3.0'
lnsulation depth: 3.5'
12
434
34
632
19
15
534
25
23
477
76
2L
79L
151
328
L23
r42
0.300
0.059
0.300
0.0s9
0.160
0.300
0.059
0.160
0.300
0.0s9
0.450
0.300
0.059
0.300
0.052
0.300
0.05s
0.300
0.060
0.300
0.060
0.300
0.300
0.060
0.300
0.300
0.060
0.300
0.300
0.060
0.300
0.060
0.300
0.055
20.0 0.0
20.0 0.0
20.0 0.0
20.0 0.0
20.0 0.0
26.O 0.0
0.0 t_5.0
L2T 0.0 15.0 0.055 0.055
r42
121 0.0 30.0 0.030 0.055
4
24
10
35
3
5
29
4
7
19
34
6
38
45
11
37
6
4
24
10
36
6
5
29
8
7
L9
23
6
38
45
T2
37
6
0.0 15.0 0.055 0.0ss 6
Compliance StatemenL The proposed building design described here is consistentwith the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2018 IECC requirements in
REscheckVersion : REScheck-Web and to comply with the mandatory requirements listed in the REscheck lnspection Checklist,
Name - Title Date
5 5
3 5
6
Signature
Project Title: Kyle & Jill Byman
Data filename:
Report date: 06123125
Page2of 2
2A18 IECC Energy
Efficiency Certificate
Above-Grade Wall
Below-Grade Wall
Floor
Ceiling / Roof
Ductwork (unconditioned spaces):
Window
Door
Heating System
20.oo
15.0O
o.oo
49.OO
o.30
o.45
Date
Sc+(z
,tCooling System
Err,cl t\nc-cl-
lLlAWater Heate
Name:
Comments
R-Valuelnsulation Rating
Glass & Door Rating U-Factor SHGC
EfficiencyHeating & Cooling Equipment