HomeMy WebLinkAboutEngineer's OWTS Design PlanSETBACK DISTANCES FROM SOIL TREATMENT AREA, GARFIELD COUNTY (06/18/18): SPRING, WELLS, SUCTION LINES, CISTERNS - 100 FT POTABLE WATER SUPPLY LINE - 25 FT STRUCTURE W/ BASEMENT, CRAWL SP. OR FOOT. DRAINS- 20 FT STRUCTURE W/O BASEMENT, CRAWL SP. OR FOOT. DRAINS- 10 FT PROPERTY LINES/EASEMENTS, PIPED OR LINED IRRIGATION DITCH- 10 FT SUBSURF. DRAIN, INT. IRRIGATION LATERAL, DRY GULCH, CUT BANK, FILL AREA- 25 FT LAKE, WATER COURSE, IRRIGATION DITCH, STREAM, WETLAND- 50 FT SEPTIC TANK, DOSING TANK, VAULT OR PRIVY- 5 FT SETBACK DISTANCES FROM BUILDING SEWER OR EFFLUENT LINES APPROX. LOT LINES AP P R O X . L O T L I N E S 10 ' P R O P E R T Y L I N E S E T B A C K DRIVEWAY ENTIRETY OF LOT NOT SHOWN FOR CLARITY *IMPORTANT NOTE* BLACK CANYON ENGINEERS AND GARFIELD COUNTY TO BE PRESENT FOR INSPECTION BEFORE SYSTEM IS COVERED. NOTIFY MIN. 5 BUSINESS DAYS IN ADVANCE (2.42 ACRES) EXI S T I N G 5 B D R M . H O U S E PROPOSED S.T.A., (3) TRENCH, 3' X 80' 20 CHAMBERS PER TRENCH 60 CHAMBERS TOTAL PROTECT FROM DISTURBANCES, COMPACTION, OR DAMAGE BY MEANS OF STAKING, FENCING, POSTING, ETC. PROPOSED SEPTIC TANK, 1,500 GAL. MIN. EXISTING CLEANOUT WITHIN 5' OF BLDG. (APPROX. LOCATION) 4" DIA. SDR 35 PVC, MIN. 1% SLOPE, FROM TANK TO S.T.A. CO TEST PIT 2 TEST PIT 1 DISTANCES BETWEEN FEATURES ARE APPROX., PROVIDED FOR REF. & SHOULD BE VERIFIED BY SURVEY 256 OLD NATIVE LANE GLENWOOD SPRINGS, CO EXISTING 1,500 GAL. SEPTIC TANK (APPROX. LOCATION) SEE DETAILS ON SHEET SP2 EXISTING S.T.A. (APPROX. LOCATION) ABANDON IN PLACE PER AHJ & CO. REG. 43 4 HOLE D-BOX W/ RISER INSPECTION PORT (6 TOTAL) 4" DIA. PVC SOLID PIPE W/ CAP. INSTALLED AT FIRST & LAST CHAMBER IN EACH TRENCH APP R O X . L O T L I N E S 10' P R O P E R T Y L I N E S E T B A C K 100' 10' 10' 100' OVERHEAD POW E R E A S E M E N T ( A P P R O X . L O C A T I O N ) P R O V I D E D F O R R E F . VERIFY IN FIELD EXISTING INFLUENT LINE (APPROX. LOCATION) CO DOUBLE SWEEP CLEANOUT (SEE NOTE A ON SHEET SP2) NOTE: AHDERE TO ALL THE SETBACKS IN REGARDS TO THE POTABLE WATER SUPPLY LINE TO ALL THE PROPOSED OWTS COMPONENTS. APPROXIMATE LOCATION OF THE POTABLE WATER SUPPLY LINE UNKNOWN. SLEEVE & BED CONVEYANCE LINE WHERE PIPE IS SUBJECT TO VEHICLE TRAFFIC (MIN. SCH. 40 RATING)4" DIA. SCH. 40 PVC, MIN. 2% SLOPE, FROM TIE-IN LOCATION TO TANK SETBACK DISTANCES FROM SEPTIC TANK, H.L.T. UNIT, DOSING TANK, VAULT GARFIELD COUNTY (06/18/18): SPRING, WELLS, SUCTION LINES, CISTERNS - 50 FT POTABLE WATER SUPPLY LINE - 10 FT STRUCTURE W/ BASEMENT, CRAWL SP. OR FOOT. DRAINS- 5 FT STRUCTURE W/O BASEMENT, CRAWL SP. OR FOOT. DRAINS- 5 FT PROPERTY LINES/EASEMENTS, PIPED OR LINED IRRIGATION DITCH- 10 FT SUBSURF. DRAIN, INT. IRRIGATION LATERAL, DRY GULCH, CUT BANK, FILL AREA- 10 FT LAKE, WATER COURSE, IRRIGATION DITCH, STREAM, WETLAND - 50 FT SEPTIC TANK, DOSING TANK, VAULT OR PRIVY - N/A SETBACK DISTANCES FROM BUILDING SEWER OR EFFLUENT LINES GARFIELD COUNTY (06/18/18): SPRING, WELLS, SUCTION LINES, CISTERNS - 50 FT POTABLE WATER SUPPLY LINE - 5 FT STRUCTURE W/ BASEMENT, CRAWL SP. OR FOOT. DRAINS- 0 FT STRUCTURE W/O BASEMENT, CRAWL SP. OR FOOT. DRAINS- 0 FT PROPERTY LINES/EASEMENTS, PIPED OR LINED IRRIGATION DITCH- 10 FT SUBSURF. DRAIN, INT. IRRIGATION LATERAL, DRY GULCH, CUT BANK, FILL AREA- 10 FT LAKE, WATER COURSE, IRRIGATION DITCH, STREAM, WETLAND- 50 FT SEPTIC TANK, DOSING TANK, VAULT OR PRIVY- N/A Black Canyon Engineers 222 S Park Ave. Montrose, CO 81401 970-568-5391 Support@BlackCanyonEngineers.com www.BlackCanyonEngineers.com IF NO P. E . S T A M P I S P R E S E N T , THIS IS A D R A F T S E T A N D SHALL N O T B E U S E D F O R CONSTRU C T I O N O R MATERIA L S P U R C H A S E SP1 Coon OWTS 256 Old Native Lane Glenwood Springs, CO 81601 Garfield County, CO Single Family Residence BCE052517 07/03/25 As Noted 1)OWNER/BUILDER/CONTRACTOR TO VERIFY ACCURACY OF SEPTIC (O.W.T.S) PLANS WITH ARCHITECTURAL & OTHER PLANS AND NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO EXCAVATION, CONSTRUCTION OR MATERIALS PURCHASE. 2)THE ENGINEER SHALL BE NOTIFIED A MINIMUM OF 5 BUSINESS DAYS IN ADVANCE VIA EMAIL AT INSPECTIONS@BLACKCANYON ENGINEERS.COM FOR INSPECTION AS PER NOTES ON PAGE SP2. 3)THE ENGINEER SHALL BE NOTIFIED IF ADVERSE OR POOR SOIL CONDITIONS OR WATER ARE ENCOUNTERED UPON EXCAVATION. FURTHER ENGINEERING MAY BE REQUIRED 4) VALID, ORIGINAL DOCUMENT ONLY WITH EMBOSSED, SIGNED SEAL 5) ALL NOTES & REQUIREMENTS FROM PAGE SP2 APPLY TO PAGE SP1 6) ALL MEASUREMENTS TAKEN WITH BASIC COMPASS, RECREATIONAL LASER RANGE FINDER & GPS. ACCURACY IS LIMITED TO THAT OFFERED BY STATED INSTRUMENTS 7) STATED DIMENSIONS TAKE PRECEDENT OVER MEASURED/SCALED DIMENSIONS 8) TOTAL PAGES: 2 SIZE: ANSI D ("22 X 34") DESCRIPTIONREV.DATE 07/29/2025 SETBACK DISTANCES FROM SEPTIC TANK, H.L.T. UNIT, DOSING TANK, VAULT GARFIELD COUNTY (06/18/18): SPRING, WELLS, SUCTION LINES, CISTERNS - 50 FT POTABLE WATER SUPPLY LINE - 10 FT STRUCTURE W/ BASEMENT, CRAWL SP. OR FOOT. DRAINS- 5 FT STRUCTURE W/O BASEMENT, CRAWL SP. OR FOOT. DRAINS- 5 FT PROPERTY LINES/EASEMENTS, PIPED OR LINED IRRIGATION DITCH- 10 FT SUBSURF. DRAIN, INT. IRRIGATION LATERAL, DRY GULCH, CUT BANK, FILL AREA- 10 FT LAKE, WATER COURSE, IRRIGATION DITCH, STREAM, WETLAND - 50 FT SEPTIC TANK, DOSING TANK, VAULT OR PRIVY - N/A SETBACK DISTANCES FROM SOIL TREATMENT AREA, GARFIELD COUNTY (06/18/18): SPRING, WELLS, SUCTION LINES, CISTERNS - 100 FT POTABLE WATER SUPPLY LINE - 25 FT STRUCTURE W/ BASEMENT, CRAWL SP. OR FOOT. DRAINS- 20 FT STRUCTURE W/O BASEMENT, CRAWL SP. OR FOOT. DRAINS- 10 FT PROPERTY LINES/EASEMENTS, PIPED OR LINED IRRIGATION DITCH- 10 FT SUBSURF. DRAIN, INT. IRRIGATION LATERAL, DRY GULCH, CUT BANK, FILL AREA- 25 FT LAKE, WATER COURSE, IRRIGATION DITCH, STREAM, WETLAND- 50 FT SEPTIC TANK, DOSING TANK, VAULT OR PRIVY- 5 FT GENERAL NOTES: 1)DESIGN AND OVERALL CONSTRUCTION INCLUDING COMPONENTS SHALL CONFORM TO THE REQUIREMENTS OF GARFIELD COUNTY, CO. REG. 43, THE N.E.C. & THE COLORADO PLUMBING CODE. 2)LOCATE ALL EXISTING UTILITIES AND CONFIRM THAT ALL SETBACKS REQUIRED BY GARFIELD COUNTY & THIS DRAWING CAN BE SATISFIED PRIOR TO EXCAVATION, CONSTRUCTION OR MATERIALS PURCHASE. 3)PVC PIPE TO BE EQUIVALENT TO OR GREATER THAN STRENGTH AS PER ASTM D3034 FOR UN-PERFORATED & EQUIVALENT TO OR GREATER THAN STRENGTH AS PER ASTM D2729 FOR PERFORATED PIPE. ALL ANGLED PIPE CONNECTIONS ON SOLIDS LINES SHALL BE 45 OR 22.5 DEGREE ONLY. 4)SEPTIC TANK SHALL BE A TWO COMPARTMENT TANK WITH A SEALED TANK BAFFLE, MANUFACTURED BY A COLORADO DPHE APPROVED MANUFACTURER THAT MEETS REQ'S OF GARFIELD COUNTY & CO. REG. 43. FOLLOW ALL MFG. INSTRUCTIONS & MAINTENANCE REQS. LEVEL GRADE AND PROOF COMPACT OR BED BOTTOM OF EXCAVATION TO ENSURE LEVEL AND STABLE INSTALLATION OF TANK. 5)TANK SIZES SPECIFIED HEREIN ARE BOTH NOMINAL AND MINIMUM. FOR SYSTEMS WHERE A PUMP IS PLACED IN THE TANK, OWNER/INSTALLER TO VERIFY THAT SELECTED TANK HAS SUFFICIENT EXCESS VOLUME SO AS TO NOT GO BELOW THE MINIMUM SIZE WHEN THE PUMP VOLUME IS SUBTRACTED OUT. 6)IF A PLASTIC (POLY) TANK IS USED, THE BRAND OF TANK SHALL BE INFILTRATOR, ORENCO, OR NORWESCO. IF THE SYSTEM INCLUDES A PUMP, THE PUMP SHOULD BE PLACED IN A SEPARATE DOSING TANK FOLLOWING THE MAIN TANK AND NOT THE SEPTIC TANK. 7)IF A PLASTIC (POLY) TANK IS USED, OWNER/INSTALLER SHALL ANCHOR TANK DOWN DUE TO BUOYANCY CONCERNS. FOLLOW ALL MFG.'S INSTRUCTIONS. 8)FOLLOW ALL COMPONENT (D-BOXES, EFFLUENT FILTERS, PUMPS, FLOATS, CONTROL PANELS, ETC.) MFG.'S INSTRUCTIONS INCLUDING LEVEL PLACEMENT & CODE COMPLIANCE WHERE APPLICABLE. 9)FOR PRESSURE DIST. SYSTEMS: FLOW, MEASURED VIA WATER SQUIRT HEIGHT, MUST BE MADE EQUAL BETWEEN LATERALS BY FLOW EQUALIZING / THROTTLING VALVES IN MANIFOLD. A 30-72" OPERATING HEAD (OR EQUIV. SQUIRT HEIGHT) MUST BE AT DISTAL END OF LATERALS. INSTALLER MUST PROVIDE PHOTOS TO ENGINEER VERIFYING SUCH. ENSURE ALL LIQUID DRAINS TO FIELD OR BACK TO TANK SO AS TO PREVENT FREEZING OF LINE. FLOAT POSITIONS & SYS. CONFIG. BY OTHERS. EFFLUENT FILTER MUST BE INSTALLED BEFORE ANTI-SIPHON VALVE WHEN S.T.A. ELEVATION IS BELOW PUMP ELEVATION. 10)ALL CONVEYANCE LINES PRIOR TO THE SEPTIC TANK SHALL HAVE 1 DOUBLE SWEEP CLEANOUT W/RISER EVERY 100' IN ADDITION TO THE ONE REQUIRED WITHIN 5' OF THE BUILDING. 11)INFILTRATIVE SURFACE TO BE LEVEL, U.N.O. MAX DEPTH IS 4 FT. 12)SEED THE FINISHED SURFACE OF LEACH FIELD AND DISTURBED SOIL AREAS AFTER CONSTRUCTION. 13)GRADE GROUND AROUND SEPTIC SYSTEM SO AS TO DIVERT WATER AWAY FROM THE STA. ROLLING, HYDRAULIC COMPACTION & MACHINE TAMPING NOT PERMITTED. 14)PRIOR TO CONSTRUCTION, SUBMIT ALL APPLICATIONS, PAY ALL FEES, AND OBTAIN THE PROPER PERMITS FROM GARFIELD COUNTY. 15)SUBMIT A CLEAR AS-BUILT DRAWING OF THE ACTUAL CONSTRUCTION TO THE ENGINEER AT COMPLETION. THIS SHALL INCLUDE DIMENSIONAL TIES TO THE SEPTIC TANK CLEANOUTS AND TO AT LEAST TWO CORNERS OF THE S.T.A. THERE SHALL BE TWO TIES TO EACH POINT, REFERENCED TO PERMANENT FEATURES ON THE SURFACE SUCH AS CORNERS OF THE BUILDING. 16)THE ENGINEER, WITH 5 BUSINESS DAYS NOTICE VIA EMAIL AT INSPECTIONS@BLACKCANYONENGINEERS.COM, WILL MAKE FIELD OBSERVATIONS OF THIS WORK. THE FOLLOWING OBSERVATIONS WILL BE REQUIRED: A.AFTER INSTALLATION OF DISTRIBUTION SYSTEM, LEFT EXPOSED TO CONFIRM LEVEL CONSTRUCTION WITHIN 1" MAXIMUM TOLERANCE. 17)AT ANY POINT DURING INSTALLATION IF THE INSTALLER ENCOUNTERS A SOIL HORIZON, GROUNDWATER DEPTH, OR BEDROCK DEPTH THAT DIFFERS FROM THAT SHOWN ON THIS DRAWING, NOTIFY E.O.R. 18)ALL SYSTEM PIPING, EXCEPT FOR DISTRIBUTION LATERALS WITHIN THE S.T.A., MUST BE BEDDED WITH SELECT MATERIAL BEFORE FINAL INSPECTION BY LOCAL PUBLIC HEALTH AGENCY. SELECT MATERIAL MUST CONSIST OF LOOSE, GRANULAR MATERIAL, FREE FROM STONES, CLODS, FROZEN SOIL, OR OTHER DELETERIOUS MATERIAL. BEDDING MATERIAL MUST BE MECHANICALLY COMPACTED TO SUPPORT PIPING. SETBACK DISTANCES FROM BUILDING SEWER OR EFFLUENT LINES GARFIELD COUNTY (06/18/18): SPRING, WELLS, SUCTION LINES, CISTERNS - 50 FT POTABLE WATER SUPPLY LINE - 5 FT STRUCTURE W/ BASEMENT, CRAWL SP. OR FOOT. DRAINS- 0 FT STRUCTURE W/O BASEMENT, CRAWL SP. OR FOOT. DRAINS- 0 FT PROPERTY LINES/EASEMENTS, PIPED OR LINED IRRIGATION DITCH- 10 FT SUBSURF. DRAIN, INT. IRRIGATION LATERAL, DRY GULCH, CUT BANK, FILL AREA- 10 FT LAKE, WATER COURSE, IRRIGATION DITCH, STREAM, WETLAND- 50 FT SEPTIC TANK, DOSING TANK, VAULT OR PRIVY- N/A 0 1 2 3 4 5 6 7 8 9 10 FEET DESIGN FLOW CALCULATIONS: 5 BEDROOM HOUSE: OCCUPANCY = 8 PERSONS 8 PERSONS X 75 GAL./PERSON/DAY = 600 GAL./DAY (GARFIELD COUNTY REGS., TABLE 6-1) SEPTIC TANK SIZING: 5 BEDROOM HOUSE = 1,500 GALLON MINIMUM SIZE (GARFIELD COUNTY REGS., TABLE 9-1) SOIL TREATMENT AREA SIZING: LONG TERM ACCEPTANCE RATE IS BASED ON SOIL OBSERVATIONS IN THE VICINITY OF THE PROPOSED LOCATION OF THE SOIL TREATMENT AREA. SOIL IS CLASSIFIED AS SOIL TYPE 2, SANDY LOAM. A LONG TERM ACCEPTANCE RATE (LTAR) OF 0.60 GAL/DAY/FT2 IS APPROPRIATE FOR THIS TYPE OF SOIL (GARFIELD COUNTY REGS., TABLE 10-1). AREA REQUIRED = DESIGN FLOW/LTAR = 600 GPD/0.60 = 1,000 SQ. FT. SIZE ADJUSTMENT FACTOR FOR APPLICATION TO GRAVITY TRENCH: 1,000 SQ. FT. X 1.0 = 1,000 SQ. FT. (GARFIELD COUNTY REGS., TABLE 10-2) SIZE ADJUSTMENT FACTOR FOR APPLICATION VIA CHAMBERS: 1,000 SQ. FT. X 0.7 = 700 SQ. FT. (GARFIELD COUNTY REGS., TABLE 10-3) EACH STANDARD CHAMBER IS 12 SQ. FT.; 700 SQ. FT. / 12 SQ. FT. = 58.33 SO USE 60 CHAMBERS (3) TRENCH, 3 FT. X 80 FT., 20 CHAMBERS PER TRENCH PLUS INLET/OUTLET ENDS PROFILE TEST PIT LOG: NOT TO SCALE TESTING PERFORMED BY BCE ON 06/17/2025 (0'-10") LOAMY TOPSOIL W/ ROOTS & ORGANICS (10"-8') SANDY LOAM W/ MIXTURE OF SMALL TO MEDIUM SIZED COBBLES NO BEDROCK OR GROUNDWATER ENCOUNTERED TO 8' INFILTRATOR WATER TECHNOLOGIES QUICK4 STANDARD CHAMBER TRENCH CONFIGURATION 60 CHAMBERS TOTAL IN 3 TRENCHES, EACH 80' LONG (NOT TO SCALE) 4' MIN 3' STANDARD CAPACITY END PLATES (TYP.) STANDARD CAPACITY CHAMBERS INSPECTION PORT TO BE INSTALLED AT FIRST & LAST CHAMBER IN EACH TRENCH (TYP.) 3' 4' MIN 3' 4 HOLE D-BOX W/ RISER HOME EXISTING CLEANOUT WITHIN 5' OF THE BUILDING EXISTING INFLUENT LINE 4" DIA. SDR 35 SOLID PVC PIPE, MIN. 1% SLOPE, FROM TANK TO S.T.A. 1,500 GAL. MIN., TWO COMPARTMENT SEPTIC TANK. TOP VIEW - TANK & CONVEYANCE LINES NOT TO SCALE 80' (TYP.) 20 CHAMBERS PER TRENCH PLUS INLET/OUTLET ENDS (36" WIDE TRENCH) 34"4' MIN.34" 12" NATIVE BACKFILL INFILTRATOR WATER TECHNOLOGIES QUICK4 STANDARD CHAMBER TYPICAL TRENCH DETAIL SECTION VIEW (NOT TO SCALE) 8" INVERT 4' MIN.34" MIN. 12" COVER TOPSOIL (36" WIDE TRENCH)(36" WIDE TRENCH) MIN. 24" MAX. 48" SCARIFY SURFACE OF IN-SITU SOIL & AVOID COMPACTING WITH EQUIPMENT (TYP.) 1% MIN 2% MIN HOUSE/GARAGE OWTS PROFILE SCHEMATIC NOT TO SCALE SEPTIC TANK OF MIN. SIZE SPECIFIED HEREIN 4" DIA. SDR 35 PVC SOLID PIPE, FROM TANK TO S.T.A. 4" DIA. SCH. 40 PVC SOLID PIPE, FROM TIE-IN LOCATION TO TANK FINISHED FLOOREXISTING CLEANOUT FINISHED GRADE SOIL TREATMENT AREA (S.T.A.) SEE DETAIL & SECTION HEREIN 48" 53" (EFFECTIVE LENGTH)12" 11.5" OUTLET END* (EFFECTIVE LENGTH) TOP VIEW SIDE VIEW END VIEW 34" QUICK4 STANDARD MULTIPORT END CAP 34" 12" INSPECTION PORT 16" 15" INLET END* (EFFECTIVE LENGTH) 8" INVERT INFILTRATOR WATER TECHNOLOGIES QUICK4 STANDARD CHAMBER PRODUCT SPECIFICATIONS (NOT TO SCALE)SYSTEM MAINTENANCE: IT IS RECOMMENDED TO MINIMIZE KITCHEN DISPOSAL USAGE, INTRODUCE NO FOREIGN CHEMICAL COMPOUNDS, CONSERVE WATER USAGE AND TO HAVE THE SEPTIC TANK PUMPED, THE SYSTEM INSPECTED & MAINTAINED EVERY YEAR. ALL MAINTENANCE IS THE RESPONSIBILITY OF THE OWNER. WITH PROPER CARE AND MAINTENANCE THIS SYSTEM SHOULD LAST MANY YEARS. IF YOU HAVE ANY QUESTIONS OR CONCERNS ABOUT YOUR SYSTEM PERFORMANCE OR MAINTENANCE, CONTACT A LICENSED SEPTIC PROFESSIONAL. ALL SYSTEM PIPING, EXCEPT FOR DISTRIBUTION LATERALS WITHIN THE SOIL TREATMENT AREA, MUST BE BEDDED WITH SELECT MATERIAL BEFORE FINAL INSPECTION BY THE LOCAL PUBLIC HEALTH DEPARTMENT. SELECT BEDDING MATERIAL MUST CONSIST OF LOOSE, GRANULAR MATERIAL, FREE FROM STONES, CLODS, FROZEN SOIL, OR OTHER DELETERIOUS MATERIAL. SELECT MATERIAL MAY CONSIST OF ON-SITE JOB EXCAVATED OR IMPORTED MATERIAL. BEDDING MATERIAL MUST BE MECHANICALLY COMPACTED TO SUPPORT PIPING. ABANDONMENT OF EXISTING TANK: 1. A TANK MAY BE COMPLETELY REMOVED AND THE PARTS DISPOSED OF SAFELY. 2. IF THE TANK WILL REMAIN IN PLACE: - THE TANK MUST BE PUMPED TO REMOVE AS MUCH WASTE AS POSSIBLE. - THE BOTTOM OF THE TANK MUST BE BROKEN SO THE TANK NEITHER FLOATS NOR FILLS WITH WATER. - THE TOP MUST BE COLLAPSED AND THE SIDES MAY BE BROKEN INTO THE VOID. - THE REMAINING VOID MUST BE FILLED WITH GRAVEL, SAND OR COMPACTED SOIL. - THE FILLED EXCAVATION WILL BE GRADED TO SURROUNDINGS, ALLOWING FOR SETTLING. GARFIELD COUNTY REGS., 43.9.C. EXISTING INFLUENT LINE GARFIELD COUNTY REGS., 43.10.F.6.E THE TOP OF INSPECTION PORTS MAY BE TERMINATED BELOW THE FINAL GRADE IF EACH IS HOUSED IN A COMPONENT SUCH AS A VALVE BOX FOR A LAWN IRRIGATION SYSTEM AND HAS A REMOVABLE COVER AT THE GROUND SURFACE. AT ANY POINT DURING INSTALLATION IF THE INSTALLER ENCOUNTERS A SOIL HORIZON, GROUNDWATER DEPTH, OR BEDROCK DEPTH THAT DIFFERS FROM THAT SHOWN ON THIS DRAWING, NOTIFY E.O.R. TWO COMPARTMENT SEPTIC TANK OF SIZE SPECIFIED HEREIN. LEVEL GRADE AND PROOF COMPACT OR BED BOTTOM OF EXCAVATION TO ENSURE LEVEL AND STABLE INSTALLATION 24" MIN 4" MIN 20" MIN AS CONDITIONS REQUIRE VAULT INLET PORT EFFLUENT DISCHARGE TO S.T.A. - 1% MIN SLOPE INSTALL POLYLOK EFFLUENT SCREEN OR NSF CERTIFIED EQUIVALENT SET RISER ADAPTER IN RAM-NECK OR MASTIC ADHESIVE SEALANT PVC RISER OSI MOD. #RR24 x 30"± W/ GROMMET(S). (BOND TO TANK ADAPTER W/ RECOMMENDED ADHESIVE OR EQUIVALENT) MUST BE WATERTIGHT INSULATED FIBERGLASS GASKETED LID W/ STAINLESS STEEL BOLTS. OSI MOD. #FL24GV. USE FL30GV IN MANHOLES > 2' DEEP SLOPE GROUND AWAY FROM RISER (TYP.) TANK BAFFLE INLET TEE FROM HOUSE TYPICAL SEPTIC TANK NOT TO SCALE 1,500 GALLON MIN. 2 COMPARTMENT SEPTIC TANK 4" DIA. SCH. 40 SOLID PVC PIPE, MIN. 2% SLOPE, FROM TIE-IN LOCATION TO TANK GARFIELD COUNTY REGS., TABLE 7-1, SUBNOTE 2 CROSSINGS OR ENCROACHMENTS MAY BE PERMITTED PROVIDED THAT THE WATER OR WASTEWATER CONVEYANCE PIPE IS ENCASED FOR THE MINIMUM SETBACK DISTANCE ON EACH SIDE OF THE CROSSING. A LENGTH OF PIPE SHALL BE USED WITH A MINIMUM SCHEDULE 40 RATING OF SUFFICIENT DIAMETER TO EASILY SLIDE OVER AND COMPLETELY ENCASE THE CONVEYANCE. RIGID END CAPS OF AT LEAST SCHEDULE 40 RATING MUST BE GLUED OR SECURED IN A WATERTIGHT FASHION TO THE ENDS OF THE ENCASEMENT PIPE. A HOLE OF SUFFICIENT SIZE TO ACCOMMODATE THE PIPE SHALL BE DRILLED IN THE LOWEST SECTION OF THE RIGID CAP SO THAT THE CONVEYANCE PIPE RESTS ON THE BOTTOM OF THE ENCASEMENT PIPE. THE AREA IN WHICH THE PIPE PASSES THROUGH THE END CAPS SHALL BE SEALED WITH AN APPROVED UNDERGROUND SEALANT COMPATIBLE WITH THE PIPING USED. OTHER METHODS OF ENCASEMENT THAT PROVIDE EQUAL PROTECTION ARE ALLOWED. THESE METHODS MUST BE REVIEWED AND APPROVED BY THE LOCAL PUBLIC HEALTH AGENCY. GARFIELD COUNTY REGS., 43.9.E.4 CLEANOUTS MUST BE PROVIDED AT INTERVALS WITHIN THE BUILDING SEWER FROM THE STRUCTURE TO THE TANK OF NOT MORE THAN 100 FEET. THE EFFLUENT PIPE BETWEEN THE SEPTIC TANK AND SOIL TREATMENT AREA IS EXEMPT FROM THIS REQUIREMENT. NOTE A (IF THIS DISTANCE EXCEEDS 100', SEE NOTE A) Black Canyon Engineers 222 S Park Ave. Montrose, CO 81401 970-568-5391 Support@BlackCanyonEngineers.com www.BlackCanyonEngineers.com IF NO P. E . S T A M P I S P R E S E N T , THIS IS A D R A F T S E T A N D SHALL N O T B E U S E D F O R CONSTRU C T I O N O R MATERIA L S P U R C H A S E SP2 Coon OWTS 256 Old Native Lane Glenwood Springs, CO 81601 Garfield County, CO Single Family Residence BCE052517 07/03/25 As Noted 1)OWNER/BUILDER/CONTRACTOR TO VERIFY ACCURACY OF SEPTIC (O.W.T.S) PLANS WITH ARCHITECTURAL & OTHER PLANS AND NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO EXCAVATION, CONSTRUCTION OR MATERIALS PURCHASE. 2)THE ENGINEER SHALL BE NOTIFIED A MINIMUM OF 5 BUSINESS DAYS IN ADVANCE VIA EMAIL AT INSPECTIONS@BLACKCANYON ENGINEERS.COM FOR INSPECTION AS PER NOTES ON PAGE SP2. 3)THE ENGINEER SHALL BE NOTIFIED IF ADVERSE OR POOR SOIL CONDITIONS OR WATER ARE ENCOUNTERED UPON EXCAVATION. FURTHER ENGINEERING MAY BE REQUIRED 4) VALID, ORIGINAL DOCUMENT ONLY WITH EMBOSSED, SIGNED SEAL 5) ALL NOTES & REQUIREMENTS FROM PAGE SP2 APPLY TO PAGE SP1 6) ALL MEASUREMENTS TAKEN WITH BASIC COMPASS, RECREATIONAL LASER RANGE FINDER & GPS. ACCURACY IS LIMITED TO THAT OFFERED BY STATED INSTRUMENTS 7) STATED DIMENSIONS TAKE PRECEDENT OVER MEASURED/SCALED DIMENSIONS 8) TOTAL PAGES: 2 SIZE: ANSI D ("22 X 34") DESCRIPTIONREV.DATE 07/29/2025