HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT BLCO -07 -25-9396 GARCO PREMIER HANGERS NEW BRAVO HANGER 375 COUNTY ROAD 352, RIFLE LOT 43 THE APPROVED PLANS ARE TO BE ON-SITE FOR INSPECTIONS. SANITARY FACILITIES ARE REQUIRED TO BE PROVIDED FOR WORKERS A LIST OF REQUIRED INSPECTIONS WILL BE ATTACHED TO THE PLANS. THE STATE IS TO PERMIT AND APPROVE THE ELECTRICAL WORK. HTTPS:/AAAAM COLORADO.GOV/PACI FIC/DORA/DPO ELECTRICAL PLUM Bl NG PER MITS UNDERGROUND UTILITY LOCATES IS THE RESPONSIBILITY OF THE OWNER OR CONTRACTOR. 811 IS THE COLORADO UTILITY LOCATE HOT LINE. ALL BACKFLOW PREVENTERS ARE REQUIRED TO BE TESTED AND CERTIFIED BY A LICENSED BACKFLOW SPECIALIST AFTER INSTALLATION AND PRIOR TO ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. SEPARATE SIGN PERMITS ARE REQUIRED FOR ANY EXTERNAL SIGNS. PLEASE CONTACT THE COUNTY PLANNER FOR THE APPLICATION. ELECTRICAL CODE COMPLIANCE WILL BE DETERMINED BASED ON FIELD tNSPECT|ONS PERFORMED BY THE STATE ELECTRICAL INSPECTOR, (303) 869- 3458. PLEASE HAVE THE INSPECTOR SIGN THE BUILDING CARD OR PROVIDE WRITTEN DOCUMENTATION OF THE INSPECTIONS. THE ELECTRICAL CODE REQUIRES A SEPARATE ELECTRICAL PERMIT FOR LOW VOLTAGE FIRE ALARMS THAT HAS AN ALARM PANEL AND SEND A NOTIFICATION TO THE FIRE DISTRICT WHEN UNDER ALARM. A ROUGH-IN INSPECTION WITH THE STATE ELECTRTCAL |NSPECTOR tS REQUTRED (303) 869-3458. PLEASE HAVE THE INSPECTOR SIGN THE BUILDING CARD OR PROVIDE WRITTEN DOCUMENTATION OF THE INSPECTION. THE FIRE SPRINKLER AND ALARM ARE REQUIRED TO BE INSPECTED AND APPROVED BY THE LOCAL FIRE PROTECTION DISTRICT. PLEASE PROVIDE SHOP DRAWINGS TO THE FIRE DISTRICT FOR REVIEWAND SCHEDULE THE INSPECTIONS ACCORDINGLY. PLEASE HAVE THE FIRE MARSHAL SIGN THE INSPECTION CARD WHEN THE ROUGH INSPECTION IS APPROVED AND WHEN THE FINAL INSPECTION IS APPROVED. ANY WATER SUPPLY THAT FEEDS A FIRE SUPPRESSION SYSTEM IS TO BE INSPECTED BY THE FIRE MARSHAL FOR THAT FIRE DISTRICT PRIOR TO BACKFILLING. PLEASE PROVIDE SPECIAL INSPECTIONS REPORTS TO THE BUILDING DEPARTMENT FOR BOLTING AND WELDING. GEOTECHNICAL OBSERVATION IS REQUIRED WHEN THE EXCAVATION IS COMPLETE AND WRITTEN VERIFICATION BE SUPPLIED AT FOOTING INSPECTION, 1500PSF. COMBUSTIBLE MATERIAL IS LIMITED WITHIN TYPE IAND TYPE II CONSTRUCTION SEE IBC 603 FOR ALLOWED COMBUSTIBLE MATERIALS. ALL EXTERIOR LIGHTING IS TO BE DOWNCNST NND SHIELDED ANY MEMBRANE AND THROUGH PENETRATIONS OF THE FIRE RESISTIVE CONSTRUCTION WILL BE REQUIRED TO BE FIRE-STOPPED WITH LISTED FIRE STOPPING ASSEMBLIES. THE CONTRACTOR IS TO PROVIDE A CUT SHEET FOR THE ASSEMBLTES AT THE FRAMTNG TNSPECT|ON. (tBC 713) A KNOX BOX IS REQUIRED TO BE MOUNTED ADJACENT TO THE FRONT DOOR. PLEASE CONTACT THE LOCAL FIRE DISTRICT FOR EXACT LOCATION. IF THE FIRE SPRINKLER SYSTEM REQUIRES A FIRE PUMP. THEN THE UTILITY nnnll Tl IAT I l^l t6r6 Tl t- nt tltn lAfll I hF hFAt ttFFh ?A hr nlt- I tnl tnn\.r\.4vt r nA I nL,rrJoEo I FIE rutvtr vvtLL Dtr r\E\,lutr\EL, I \./ DE rJt\E-r'l\J\Jr\ CoNSTRUCTTON. (rBC TABLE 508.2.5) THE WALLS SURROUNDING THE TOILET ARE TO BE NON-ABSORBENT FOR A HEIGHT OF 48'AND 2'PAST ON EACH SIDE OF THE TOILET. ALL ACCESSIBLE DOOR HARDWARE SHALL HAVE A SHAPE THAT IS EASY TO GRIP, INCLUDING POCKET AND SL|D|NG DOORS. (ANSI A117.1 - 404.2.6) GRAB BAR BACKING IS TO BE IN PLACE FOR THE TOILET THE LAYOUT OF THE RESTROOM WILL REQUIRE A RIGHT-HAND FLUSH WATER CLOSET. A VERTICAL GRAB BAR IS REQUIRED ADJACENT TO THE WATER CLOSET