HomeMy WebLinkAboutEngineer's Certification of Design CriteriaAG'g SETTTITUEL
TALLY HO CONSTRUCTION
145 COUNTY RD 225
RtFLE, CO 81650-9400
@*ln t**,*A
David M. Woebbecke, P.E.
Certifying Engineer
237 South 4th Street, P0. Box 348, Albion. NE 68620
TF800,3270790 I P402.395.5076 I F402.395.6369 I sentinelbuildings.com
Jobsite Address: 375 COUNTY ROAD 352
RtFLE, CO 81650
Date:6/10/2025
AGI-Sentinel Job lD: 844716
To Whom it May Concern
This letter is to certify that a 170'wide, 62' long building with a 25.5' back and 25.5' front eave height as referenced above and
manufactured by AGI-sentinel of Albion, Nebraska is designed in accordance with the following loads:
Roof Dead Load: 2.5 psf Seismic lmportance Factor: 1.00
Collateral Load: 1.0 psf Seismic Design Category: C
Roof Live Load: 20.0 psf Assumed Site Class: d
Rigid Frame Live Load: 12.0 psf Seismic Coefficient: 0.502 (Ss*Fa)
Risk Category: ll - Normal
ROOF SNOW LOAD FACTORS ss=0.33 s1=0.08 sDS=0.33 Sd1=0.12
Ground Snow Load: 47.62 psl SEISMIC BRACING SYSTEM: Structural Steel System Not
Flat Roof Snow Load: 40.00 psf Specifically Detailed for Seismic Resistance
Sloped RoofSnow Load (Ps): 40.00 psf
l=1.00 Ce=1.00 Ct=1.20 Cs=1'00 SEISMIC DATA Cs R
Terrain Category: C Interior Frame 0.10 3.00
Wind Load: V: 115 mph Vasd:89.08 mph Roof 0.11 3.00
Exposure C - Enclosed Left Endwall 0.11 3.00
lnternal Pressure Coefficient: +0.18 / -0.18 Right Endwall 0.11 3.00
Wind lmportance Factor: 1.00 Front Sidewall 0.11 3.00
Back Sidewall 0.11 3.00
60-min/100-year rainfall intensity: 1.0800 inlhr Longitudinal Base Shear {V): 16'20 (k)
See erection drawing cover page for special loads. Transverse Base Shear (V): 15.66 (k)
Floor Loads: None
Loads are applied in accordance with the IBC 21 building code. The certifying engineer does not certify that the building code
or loads specified are adequate or appropriate for the intended use or location of this building. The buyer is responsible for
verifying specified loads are in compliance with the local regulatory authorities.
Design is in accordance with the applicable sections of the following specifications:
Hot-rolled: 2016 ANSI/AISC 350-16 Cold-formed: 2016 AlSl 5100-15
This certification is limited to the steel framework, the metal roof and the metal wall covering, and fasteners required for their
installation. This certification specifically excludes an analysis of the foundation and parts supplied by anyone other than AGI-
Sentinel.
Sincerely,
AGI-SENTINEL
11-
38702
orusu
€
!!EElItr @assrowthintl I AGGRowrH coM