Loading...
HomeMy WebLinkAboutComCheck ComplianceCOMcheck Software Version 4.L.5.5 Envelope Gompl iance Gertificate Project lnformation Energy Code: Project Title: Location: Climate Zone: Project Type: Construction Sile: 375 CR 352 R|FLE, CO 81650 Additional Efficiency Package(s) Credits: 1.0 Required 1.0 Proposed Reduced Lighting Power, 1.0 credit Building Area 2015|ECC Bravo Hanger Rifle, Colorado 5b New Construction Owner/Agent Designer/Contractor: Bighorn Consulting Engineers 386 lndian Road Grand Junction, CO 8L501 970-24r-8709 Floor Area 1 -Transportation : Nonresidential 1 0598 Envelope Assemblies Assembly Gross Area or Perimeter Cavity R-Value Gont. R-Value Proposed U-Factor Budget U- Factorr"r Roof 1: Metal Building, Standing Seam, Double lnsulation Layer with Thermal Blocks (c), [Bldg. Use 1 - Transportation] NORTH Exterior Wall 1: Metal Building Wall, Single Layer Mineral Fiber (compressed at girt), [Bldg. Use 1 - Transportation] Door 1: Uninsulated Single-Layer Metal, Swinging, [Bldg. Use 1 - Transportationj EAST Exterior Wall 4: Metal Building Wall, Single Layer Mineral Fiber (compressed at girt), [Bldg. Use 1 - Transportation] Door 5: Other Door, Garage door 14/o glazing, [Bldg. Use 1 - Transportationl SOUTH Exterior Wall 2: Metal Building Wall, Single Layer Mineral Fiber (compressed at girt), lBldg. Use 1 - Transportation] Door 2: Uninsulated Single-Layer Metal, Swinging, [Bldg. Use 1 - Transportationl WEST Exterior Wall 3: Metal Building Wall, Single Layer Mineral Fiber (compressed at girt), [Bldg. Use 1 - Transportation] Door 3: Uninsulated Single-Layer Metal, Swinging, [Bldg. Use 1 - Transportationl Door 4: Other Door, Garage door 14/" glazing, [Bldg. Use 1 - Transportationl 1 0598 1787 32 4342 3239 1787 32 4342 32 319 20.0 0.0 0.0 49.0 20.o 0.0 0.020 0.147 0.500 0.147 0.050 0.147 0.500 0.147 0.500 0.050 0.035 0.052 0.370 0.052 0.370 0.052 0.370 0.052 0.370 0.370 20.0 0.0 20.o 0.0 Project Title: Bravo Hanger Report date: 07 128125 Data filename: 7:\2025 Projects\25216 Garco Premier Hangars\Energy - Com Check\25216 - Bravo hanger.cck Page 1 of 19 Envelope PASSES: Deslgn 22% better than code (a) Budget U-factors are used for software baseline calculations ONLY, and are not code requirements. (b) 'Other' componenls require supporting documentation lor proposed UJactors. (c) Thermal spacer block with minimum R-3.5 must be installed above the purlin/batt, and the roof deck secured lo the purlins. Envelope Gompliance Statement Compliance Statementi The proposed envelope design represented in this document is consistent with the building plans, speclflcatlons, and other calculatlons submltted wlth thls permlt appllcatlon, The proposed envelope systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.5.5 and to comply with any applicable mandatory rcquircmcnts listcd in thc lnspcction Chccklist. Blaine Buck pE "6ro;nu"6o.E{,8 7l2gl202| Name - Title Signature Date Project Title: Bravo Hanger Report date: 07 128175 Data filename: Z:\2O25 Projects\25216 Garco Premier Hangars\Energy - Com Check\25216 - Bravo hanger.cck Page 2 of L9 COMcheck Software Version 4.L.5.5 lnterior Lighting Gompliance Certificate Project lnformation Energy Code: Project Title: Project Type: 2015|ECC Bravo Hanger New Construction Owner/Agent:Construction Site: 375 CR 352 RtFLE, CO 81650 Additional Eff iciency Package(s) Credits: 1.0 Required 1.0 ProPosed Reduced Lighting Power, 1.0 credit Allowed Interior Lighting Power A Area Gategory Designer/Contractor: Bighorn Consulting Engineers 386 lndian Road Grand Junction, CO 81501 970-241,-8709 B Floor Area (fr2) c Allowed Watts / ft2 D Allowed Watts (Bxc) 1 -Transportation 1 0598 0.63 6677 Total Allowed Watts = 6677 Proposed lnterior Lighting Power A Fixture lD : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture c #of Fixtures D Fixture Watt. E (cxD) 1-Transportation LED 1: A: LED High Bay: Other:18 2 284 24 5112 48LED 2: C: LED downlioht: LED A Lam p 25W: nterior Lighting PASSES: Design 23% better than code Total Proposed Watts = 5160 lnterior Lighting Gompliance Statement Compliance Statemenf; The proposed interior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meetthe 2015 IECC requirements in COMcheckVersion 4.1.5.5 and to complywith any applicable mandatory requirements listed in the lnspection Checklist. Blaine Buck PE .6Iao"fi*"{fE 712812025 Name - Title Signature Date Project Title: Bravo Hangel Report date: 07 128125 Data filename: 2:\2025 Projects\25216 Garco Premier Hangars\Energy - Com Check\25216 - Bravo hanger'cck Page 3 of 19 COMcheck Software Version 4.L.5.5 Exterior Lighting Compliance Certificate Project Information Energy Code: Project Title: Project Type: Exterior Lighting Zone Construction Site: 375 CR 352 R|FLE, CO 81650 Allowed Exterior Lighting Power A Area/Surface Category 2015 |ECC Bravo Hanger New Construction 3 (Other (LZ3)) Owner/Agent:Designer/Contractor: Bighorrr Consulting Engineers 386 lndian Road Grand Junction, CO 81501 970-24L-8709 Quantity c Allowed Watts / Unit D Tradable Wattage E Allowed Watts (BXC) B Main entrv 184 lt of 30 Yes 5520 Total Tradable Watts (a) = 5520 Total Allowed Watts = 5520 Total Allowed Supplemental Watts (b) = 750 (a) Wattage tradeoffs are only allowed between tradable areas/surfaces. (b) A supplemental allowance equal to 750 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power A Fixture lD : Description / Lamp / Wattage Per Lamp / Ballast E (cxD) B Lamps/ Fixture c #ol Fixtures D Fixture Watt. Pedestrian and vehicular entrances and exits (184 ft of door width): Tradable Wattage LED 1: LED PAR 12W:12 27 324 Exterior Lighting PASSES: Design 95% better than code Total Tradable Proposed Watts = 324 Exterior Lighting Compliance Statement ComplianceStatementj Theproposedexteriorlightingdesignrepresentedinthisdocumentisconsistentwiththebuildingplans, specifications, and other calculations submitted with thls permit application. The proposed exterior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.5.5 and to comply with any applicable mandatory requirements listed in the lnspection Checklist. Blaine Buck pE "6Ianu,fr*,F9* TlZglZOZs Name - Title Signature Date ProjectTitle: Bravo Hanger Report dale: e7 lZBl25 Data filename: 7:\2025 Projects\25216 Garco Premier Hangars\Energy - Com Check\25216 - Bravo hanger.cck Page 4 of t 9 COMcheck Software Version 4.L,5.5 Mechanical Compliance Gertificate Project lnformation Energy Code: Project Title: Location: Climate Zone: Project Type: Construction Site: 375 CR 352 RtFLE, CO 81650 Additional Eff iciency Package(s) 2015|ECC Bravo Hanger Rifle, Colorado 5b New Construction Owner/Agent:Designer/Contractor: Bighorn Consulting Engineers 386 lndian Road Grand Junction, CO 81501 970-24L-8709 Credits: 1.0 Required 1.0 Proposed Reduced Lighting Power, 1.0 credit Mechanical Systems List Quantity System Type & Description 1 HVAC System 1 (Single Zone wl PerimeterSystem): Heating: 4 each - Radiant Heater, Gas, Capacity = 200 kBtu/h No minimum efficiency requirement applies Fan System: None HVAC System 2 (Single Zone): Heating: 1 each - Unit Heater, Electric, Capacity = 10 kBtu/h No minimum efficiency requirement applies Fan System: FAN SYSTEM 1 | restroom -- Compliance (Motor nameplate HP method) : Passes Fans: FAN 1 Supply, Constant Volume, 245 CFM, 0.1 motor nameplate hp, 0.0 fan efficiency grade Mechanical Gompliance Statement Compliance StatemenL The proposed mechanical design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the 2015 IECC requirements in COMcheckVersion 4.1.5.5 and to comply with any applicable mandatory requirements listed in the lnspection Checklist. Blaine Buck PE .6ran"6..8{'E 712812025 Name - Title Signature Date Project Title: Data filename Bravo Hanger RePort date: 07 128125 2:\2025 Projects\25216 Garco Premier Hangars\Energy - Com Check\25216 - Bravo hanger.cck Page 5 of 19 COMcheck Software Version 4,L"5"5 lnspection Checklist Energy Code: 20L5 IECC Requirements: l-.0% were addressed directly in the COMcheck software Text in the "Comments/Assrrmptions" r:olr-rmn is provided by the lrser in the COMcheck Reqr,rirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is heing clainrerl. Wlrerp rnrrrpliarrre is iternizer:l irr a separate fable, a refererrr:e trr flrat tal-rlc is Frr-rvidFd. 1 High lmpact (Tier 1)2 Medium lmpact (Tier 2)Low lmpact (Tier 3) Project Title: Bravo Hanger Report date: 07 128125 Data filename: Z:\2O25 Projects\252L6 Garco Premier Hangars\Energy - Com Check\25216 - Bravo hanger.cck Page 6 of L9 Section # & Req.lD Plan Review Complies?Comments/Assumptions Plans and/or specifications provide all information with which compliance can be determined for the building envelope and document where exceptions to the standard are clalmed. :Ecomplies : ,EDoes Not ENot Observable nNot Applicable : c103.2 lPR1l1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the mechanical systems and equipment and document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and handbooks. c103.2 lPR2l1 :nComplies nDoes Not'nNot Observable , lnruot npplicable , Plans, specifications, and/or nComplies , calculations provide all information :EDoes Not with which compliance can be determined for the inteiioi fiotrtino ENot observable and electrical systems and e-quiprie6l LJNot Applicable and document where exceptions to . : lha clrnalrrel rr^ rlri*^n lnfarmrtinn provided should include interior lighting powcr calculations, wattage of bulbs and ballasts, transformers and , control devices. c103.2 lPR4l1 'calculations provide all information DDoes Not with which compliance can be determined for the exterioi tiqhtino LlNot observable and electrical systems and eqiuipm-e61 LJNot Applicable :and document where exceptions to the standard are claimed, lnformation provided should include exterior lighting power calculations, wattage of bulbs and ballasts, transformers and .control devices. area Plans, specifications, and/or Compliesc103.2 lPR8l1 c402.4.1 lPR10l1 The vertical fenestration area <= 30 ,nComplies percent of the gross above-grade wall inDoes Not ,nNst Observable , :nNot Applicable : The skyiight area <= 3 percent of ihe gross roof area.IDoes Not !Not Observable nNot Applicable CompiiesC4A2.t+.1 lPR1111