HomeMy WebLinkAboutConditions of PermitCONDITIO NS OF PERMIT
BLCO-08 -25-9454
GLENWOOD PARTNERSHIP LLLP
TENANT FINISH FOR A HEARING CLINIC
218 CENTER DRIVE, GLENWOOD SPRINGS
COOPER MINOR SUBDIVISION
1) THE APPROVED PLANS ARE TO BE ON-SlrE FOR INSPECTIONS.
2) SANTTARY FACILIT|ES ARE REOUIRED TO BE PROVIDED FOR WORKERS.
3) A L|ST OF REOUTRED |NSPECTTONS W|LL BE ATTACHED TO THE PLANS. THE STATE lS TO PERMIT
AND APPROVE THE ELECTRICAL WORK.
4) SEPARATE SIGN PERMITS ARE REOUIRED FOR ANY EXTERNAL SIGNS. PLEASE CONTACT THE
COUNTY PLANNER FOR THE APPLICATION.
5) ELECTRICAL CODE COMPLIANCE WILL BE DETERMINED BASED ON FIELD INSPECTIONS
PERFORMED BY THE STATE ELECTRICAL INSPECTOR, (303) 869-3458. PLEASE HAVE THE
INSPECTOR SIGN THE BUILDING CARD OR PROVIDE WRITTEN DOCUMENTATION OF THE
INSPECTIONS.
6) THE FIRE SPRINKLER AND ALARM ARE REQUIRED TO BE INSPECTED AND APPROVED BY THE
LOCAL FIRE PROTECTION DISTRICT. PLEASE PROVIDE SHOP DRAWINGS TO THE FIRE DISTRICT
FOR REVIEW AND SCHEDULE THE INSPECTIONS ACCORDINGLY. PLEASE HAVE THE FIRE
MARSHAL SIGN THE INSPECTION CARD WHEN THE ROUGH INSPECTION IS APPROVED AND
WHEN THE FINAL INSPECTION IS APPROVED.
7) COMBUSTTBLE MATERTAL rS LTM|TED rN ryPE r AND TYPE il CONSTRUCTION. SEE IBC 603 FOR
ALLOWED COM BUSTI BLE MATERIALS.
8) ALL EXTERTOR LIGHTING lS TO BE DOWNCAST AND SHIELDED.
9) SAFEry GLAZING IS NOT DESIGNATED ON THE PLANS. SAFETY GLAZING WILL BE CHECKED
DURING THE FRAMING AND FINAL INSPECTION. (IBC 2406.4)
1O)ANY MEMBRANE AND THROUGH PENETRATIONS OF THE FIRE RESISTIVE CONSTRUCTION WILL
BE REOUIRED TO BE FIRE-STOPPED WITH LISTED FIRE STOPPING ASSEMBLIES. THE
CONTRACTOR IS TO PROVIDE A CUT SHEET FOR THE ASSEMBLIES AT THE FRAMING
TNSPECTTON. (rBC 713)
1 1)ALL ACCESSIBLE DOOR HARDWARE SHALL HAVE A SHAPE THAT IS EASY TO GRIP, INCLUDING
pocKET AND SLIDING DOORS. (ANSI A117.1 - 404.2.6)
12)GARBAGE DISPOSALS ARE NOT ALLOWED ON COMBINATION WASTE AND VENT SYSTEMS.
13)DO NOT TNSTALL THE CEtLtNG PANELS UNT|L ABOVE THE CETLTNG HAS BEEN INSPECTED.